www.fgks.org   »   [go: up one dir, main page]

SOUNDPROOFING SOLUTIONS - 2023

Page 1

SOUNDPROOFING SOLUTIONS TIMBER, STEEL AND MASONRY STRUCTURES


IMPACT NOISE

AIRBORNE NOISE

Noise generated by mechanical excitation of an intermediate slab (e.g. footsteps or moving furniture in a flat).

Noise that can be transmitted through the air (e.g. music or conversations).

SILENT FLOOR PUR.....................28

SILENT WALL BYTUM SA........... 60

SILENT FLOOR TEX......................32

SILENT WALL BYTUM..................62

SILENT FLOOR BYTUM...............34

SILENT GIPS..................................65

SILENT FLOOR PE........................36

GIPS BAND....................................66

SILENT FLOOR NET 3D..............38

CONSTRUCTION SEALING.......67

SILENT EDGE............................... 40

TRASPIR METAL............................70

SILENT STEP..................................45 SILENT STEP ALU.........................46 PIANO A......................................... 47 SILENT UNDERFLOOR............... 48 GRANULO......................................49

from page

21

CONTENTS

from page

55


STRUCTURAL NOISE

ACOUSTIC AND SEALING

Noise that propagates through the structure and carries vibrations even between non-contiguous rooms.

Air is one of the main medium through which sound waves propagate. Even the smallest gap allows noise to spread and affects the final performance of the building element.

XYLOFON...................................... 88

FIRE SEALING SILICONE..........140

XYLOFON WASHER ..................102

MS SEAL.......................................143

XYLOFON PLATE........................104

HERMETIC FOAM.......................144

PIANO...........................................106

EXPAND BAND............................146

CORK............................................ 116

WINDOW BAND.........................148

ALADIN......................................... 118

PLASTER BAND IN/OUT...........150

TRACK...........................................122

SMART BAND..............................158

GRANULO STRIPE.....................124 TIE-BEAM STRIPE......................126

from page

83

from page

135


A SOLUTION FOR EVERY TYPE OF NOISE Does the noise of the condominium lift keep you awake at night? You have a problem with SYSTEM VIBRATION NOISE The noise level produced by the systems is evaluated according to the type of operation. Lifts, plumbing drains and toilets are discontinuous systems; heating, ventilation and air conditioning are continuous systems.

Don't the trams passing under your house make you hear the TV? You have a problem with AIRBORNE FAÇADE NOISE Noise arriving from outside, such as passing vehicles, can cause the façade to vibrate through vertical and horizontal partitions due to the sound waves they emit. Therefore, good design and verification of the components is necessary in order to preserve the well-being within the building.

Can you hear the noise of the child jumping upstairs? You have a problem with IMPACT NOISE When a body impacts on the floor structure, the noise quickly spreads throughout the building either by air, affecting the nearest rooms, or by structure, propagating into the most distant rooms.

Is there an annoying background noise in your room? You have a problem with ACOUSTIC REVERBERATION

Can you hear your neighbour having a conversation? You have a problem with AIRBORNE NOISE Airborne noise is a set of sound waves that originates in the air and is then transmitted into adjacent rooms either by air or by structure.

6 | A SOLUTION FOR EVERYTYPE OF NOISE

Reverberation is the phenomenon that occurs due to the persistence of a sound wave in an enclosed environment, even after the sound source has ceased emitting the wave. This is because the sound wave "bounces" off surfaces and is reflected in the surroundings.


The acoustic design of a building must go through an analysis of the type of noise. Once the source of the problem has been identified, the most suitable solution can be found to improve the acoustic performance of the building component.

IMPACT NOISE Walking, moving a chair, moving any object resting on the floor leads to mechanical excitation of the floor and, consequently, to what is known as impact noise. Stop the broomstick, go to Chapter 1.

AIRBORNE NOISE It is transmitted in the air and is part of our everyday life: chatting, listening to music, playing with children.

You can always turn down the volume but also discover the alternatives in Chapter 2.

STRUCTURAL NOISE It occurs when noise propagation passes through the structure and spreads vibrations not only to adjacent rooms, but also to rooms not necessarily separated by walls or floors.

Solve the problem at the base, go to Chapter 3.

ACOUSTIC AND SEALING The sound wave propagates in the air, which makes it easy to spread and difficult to control. Precise design helps to avoid overlooking details that could compromise the building's acoustic performance.

The solution is not in the air, discover Chapter 4.

Since the decibel is a logarithmic quantity, it can be said that a 3 dB increase is equivalent to a doubling of sound energy (conversely, if we halve the sound energy, there will be a 3 dB reduction).

LOGARITHMIC SCALE

+ 3 dB = Each 10 dB increase corresponds to an increase in sound energy of 10 times.

+ 10 dB =

A SOLUTION FOR EVERYTYPE OF NOISE | 7



REFERENCES


MARIE CURIE SCHULE Frankfurt (DE) When building a school, creating a healthy climate inside the classroom is a fundamental prerequisite for good learning. The selection of top-quality materials, the use of highly specialised labour and design to high standards allow for excellent results in terms of emissions, thermal and acoustic insulation. Measurements carried out on the finished building showed a performance that far exceeded the high requirements of the German standard: the sound reduction index of the wall recorded R'w=67 dB, while for the floor, an impact sound pressure level L'nT,w=41 dB was achieved.

description

building for school use

type of structure

CLT panels

location

Frankfurt (Germany)

products

XYLOFON

STERNAECKERWEG Graz (AT) The construction of 400 timber housing units presents a challenge for acoustic comfort. Thanks to the use of XYLOFON and a detail-oriented construction, it was possible to achieve R'w=66 dB (Dnt,w=70 dB) for the partition wall and a high-performance ceiling, both in terms of airborne noise transmission R'w=62 dB (Dnt,w=62 dB), and the impact sound pressure level L'n,w=50 dB (L'nT,w=47).

description

400 housing units + childcare facility

type of structure

CLT panels

location

Graz (Austria)

products

XYLOFON

10 | REFERENCES


RESIDENTIAL BUILDING Tirol (AT) The contribution of lateral transmission can be quite significant. For this reason, the acoustic designer planned the use of XYLOFON to structurally interrupt the propagation of vibrations and consequently reduce noise transmission. This design approach resulted in a high-performance floor: Dnt,w=63 dB and L'nT,w=45 dB were measured on completion.

description

multi-storey building (3 floors) for residential use

type of structure

CLT panels

location

Tyrol (Austria)

products

XYLOFON

RESIDENTIAL BUILDING Trentino Alto Adige (IT) The project consisted in the assembly of a multi-storey prefabricated timber building, using an innovative point-to-point connection system. The correct design of the construction assembly and the use of XYLOFON to minimise lateral transmission allowed us to measure R'w=60 dB for the partition wall and R'w= 56 dB for the floor.

description

multi-storey building (3 floors) for residential use

type of structure

CLT panels

location

Trentino Alto Adige (Italy)

products

XYLOFON

REFERENCES | 11


MULTI-STOREY BUILDING Bavaria (DE) Timber structures must be designed with a different approach than traditional structures: the propagation of vibrations must be interrupted at the structural level in order to have a reduction in noise transmission. XYLOFON significantly reduces it and on this particular building site, the sound reduction index of the wall R'w=64 dB was measured.

description

multi-storey building (3 floors) for residential use

type of structure

CLT panels

location

Bavaria (Germany)

products

XYLOFON

MOHOLT STUDENT Trondheim (NO) Moholt is the largest student village in Trondheim, whose university is renowned for its international environment, with students from all over the world. The project aims to provide not only accommodation, but also to facilitate students' lives through support services and facilities. At Moholt, special attention was paid to environment and comfort: the structures were made of CLT and XYLOFON was used to create an elastic separation layer between rigid structural elements. This construction technique avoids the transmission of vibrations between components and solves the acoustic problem at its root.

description

university campus consisting of living spaces and services

type of structure

CLT panels

location

Trondheim (Norway)

products

XYLOFON

12 | REFERENCES

© Huber & Sohn GmbH & Co. KG


SOLHØY Østlandet (NO) The 11500 m2 timber building, intended for care and nursing, being a health centre, also presents a challenge in terms of acoustic comfort. In the design, particular attention was paid to the choice of materials and construction details, to create cosy spaces that can promote the recovery of in-patients. XYLOFON was chosen because it significantly reduces the transmission of vibrations, while at the same time ensuring stability and no failure over time.

description

health centre consisting of 67 health-care flats with attached user services

type of structure

CLT panels

location

Østlandet (Norway)

products

XYLOFON

LA BRIOSA HOTEL Trentino Alto Adige (IT) The project stems from the renovation of a historic masonry building, with the integration of a new timber structure, and skilfully combines respect for tradition with innovative design. A totally sustainable project, in which no glues, nails or paints are used, requires materials that are stable, will not fail over time and are waterproof, which is why XYLOFON proved to be the best choice for the project.

description

7-storey building for accommodation use

type of structure

CLT panels

location

Trentino Alto Adige (Italy)

products

XYLOFON, ALADIN, TITAN SILENT

REFERENCES | 13


RESIDENTIAL COMPLEX Île-de-France (FR) The project is located within an eco-neighbourhood full of new generation living spaces, shops and services, school environments, cycle paths and green spaces. Keeping an eye on acoustic comfort design, it was necessary to keep the structural elements separate with XYLOFON to prevent the propagation of vibrations, and thus noise, through the structure.

description type of structure

multi-storey residential building complex consisting of 78 residential units mixed concrete and CLT panel elevation

location

Île-de-France (France)

products

XYLOFON

KIHLSTRÖMSKAJ Götaland (SE) The project highlights the full potential of timber as a building material, also for the construction of apartment blocks and multi-storey buildings. In addition to the environmental benefits of renewable building materials, timber also offers a pleasant and cosy atmosphere. The complex has been divided into three buildings grouped around a common courtyard that opens onto the archipelago. The proximity to the sea requires the use of extremely chemically stable and impermeable materials. XYLOFON, with its monolithic structure, meets these requirements perfectly.

description

residential complex consisting of approximately 40 residential units

type of structure

CLT panels

location

Götaland (Sweden)

products

XYLOFON, ALADIN

14 | REFERENCES


UNIVERSITY CAMPUS Victoria (AU) In addition to being a modern student hall, this project had the ambitious goal of becoming the new benchmark for sustainable building design and construction in Australia. It is a timber student house that is completely powered by renewable energy sources that produce many environmental benefits. XYLOFON and many other Rothoblaas solutions have been used to ensure user comfort.

description

university student residence with 150 beds

type of structure

CLT panels

location

Victoria (Australia)

products

XYLOFON, ALADIN

MULTI-STOREY BUILDING Toronto (CA) The project was born out of the desire to optimise the construction process through the use of prefabricated CLT panels, maximise natural light and meet passive requirements. The high degree of airtightness of the envelope has made it possible to minimise heat loss in winter and increase indoor air quality, reducing operating costs and the building's ecological footprint. The challenge, from an acoustic point of view, was to create floors with an exposed timber structure that would guarantee high levels of comfort. Rothoblaas products were chosen for their ability to reduce the lateral transmission of noise propagation through the structure.

description

6-storey building for residential use

type of structure

CLT panels

location

Toronto (Canada)

products

XYLOFON, ALADIN

REFERENCES | 15


SMALL RESIDENTIAL BUILDING Walberswick (GB) What could be more magical than imagining the silence of a small CLT residential building set in the peace and quiet of a small village on the Suffolk coast of England? Thanks to our connectors, our resilient XYLOFON profile and the SILENT FLOOR BYTUM underscreed foil. This is a dream come true.

description

small residential building

type of structure

CLT

location

Walberswick (England)

products

XYLOFON, SILENT FLOOR BYTUM

STRUCTURAL RESTORATION El Pont de Suert (ES) In this project of structural rehabilitation of an old rural building, the product SILENT FLOOR PE was used to improve the acoustic performance of the floors against impact noise and as a waterproofing layer in order to realise the collaborating concrete layer.

description

rehabilitation of a farmhouse

type of structure

masonry structure with floor reconstruction with beams and boards

location

El Pont de Suert (Spain)

products

SILENT FLOOR PE, SILENT EDGE

16 | REFERENCES


COMMERCIAL BUILDING Atlanta (USA) The newly constructed building boasts office space, restaurants, shops, a hotel and art studios. It is a very innovative project that also uses TIMBER as a structural material. To improve the acoustic performance of the floors, SILENT FLOOR PUR was used and ALADIN was used to reduce lateral transmission.

description

commercial building covering more than 300000 sq ft

type of structure

mixed

location

Atlanta (Georgia, USA)

products

SILENT FLOOR PUR, ALADIN

COMMERCIAL BUILDING Toronto (CA) In the construction of this new commercial building, SILENT FLOOR BYTUM was used to create a floating screed system to ensure the best acoustic performance of the interior spaces.

description

commercial building

type of structure

mixed

location

Toronto (Ontario, Canada)

products

SILENT FLOOR BYTUM

REFERENCES | 17



IMPACT NOISE


IMPACT NOISE


2

IMPACT NOISE SILENT FLOOR PUR RESILIENT HIGH PERFORMANCE UNDERSCREED MEMBRANE MADE OF RECYCLED POLYMERS. . . . . . . . . . . . . . . . 28

SILENT FLOOR TEX UNDERSCREED MEMBRANE MADE OF RECYCLED TEXTILE FIBRE AND RECYCLED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

SILENT FLOOR BYTUM RESILIENT UNDERSCREED MEMBRANE MADE OF BITUMEN AND POLYESTER FELT. . . . . . . . . . . . . . . . . . . . . . . . . 34

SILENT FLOOR PE RESILIENT UNDERSCREED MEMBRANE MADE OF CLOSED CELL PE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

SILENT FLOOR NET 3D BREATHABLE MEMBRANE WITH THREE-DIMENSIONAL RESILIENT MAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

SILENT EDGE SELF-ADHESIVE STRIP FOR PERIMETER SEPARATION. . . . . . . . . 40

SILENT STEP HIGH DENSITY POLYETHYLENE SUBSTRATE WITH VAPOUR BARRIER FILM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

SILENT STEP ALU HIGH DENSITY POLYMER SUBSTRATE COVERED IN ALUMINIUM WITH AS A VAPOUR BARRIER FILM. . . . . . . . . . . . 46

PIANO A RESILIENT SOUNDPROOFING PROFILE . . . . . . . . . . . . . . . . . . . . . 47

SILENT UNDERFLOOR RESILIENT STRIP FOR FLOOR UNDERBATTENS AND SUPPORTING WALLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

GRANULO RESILIENT GRANULAR RUBBER SOUNDPROOFING PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

IMPACT NOISE | 21


ACOUSTIC PROBLEMS OF FLOORS WHAT IS IMPACT NOISE? When it comes to floors, impact noise is the main acoustic problem because it constantly affects them. When a body impacts on the floor structure, the noise quickly spreads throughout the building either by air, affecting the nearest rooms, or by structure, propagating into the most distant rooms.

WHAT IS AIRBORNE NOISE? Airborne noise is generated in the air and, after an initial airborne phase, is transported both by air and by structure. This is a problem that affects both walls and floors, but if we are talking about floors, the most important problem is certainly impact noise.

HERE IS THE SOLUTION In order to be able to minimise the discomfort caused by impact noise, a stratigraphic package should be designed consisting of layers of different materials that are disconnected from each other and are able to dissipate the energy transmitted by the impact.

MASS-SPRING-MASS SYSTEM A floating screed system such as the one shown in the images below can be schematised with a mass-spring-mass system, in which the structural floor represents the mass, the impact-absorbing product is equivalent to the spring, and the upper screed with the floor constitutes the second mass of the system. In this context, “resilient layer” is defined as the element with the spring function characterised by its own dynamic stiffness s'. screed: mass

mass

SILENT FLOOR: spring

spring

structure: mass

mass

HOW IS THE IMPACT NOISE LEVEL MEASURED? The impact noise level is a measure of the disturbance perceived in a room when an impact noise source is activated in the upper room. It can be measured both on site and in the laboratory. Clearly, ideal conditions exist in the laboratory for the effects of lateral transmission to be neglected, as the laboratory itself is constructed so that the walls are decoupled from the ceiling.

TAPPING MACHINE method The TAPPING MACHINE is used to simulate "light" and "hard" impacts, such as walking with heeled shoes or the impact caused by falling objects.

22 | ACOUSTIC PROBLEMS OF FLOORS | IMPACT NOISE

RUBBER BALL method

H = 1m +/- 0,01m

The RUBBER BALL is used to simulate "soft" and "heavy" impacts, such as a barefoot walk or a child jumping.


HOW TO CHOOSE THE BEST PRODUCT DYNAMIC STIFFNESS – s’ Expressed in MN/m3, it is measured according to EN 29052-1 and expresses the deformation capacity of a material that is subjected to a dynamic stress. Consequently, it indicates the ability to dampen the vibrations generated by an impact noise. The measurement method involves, first, measuring the apparent dynamic stiffness s't of the material and then correcting it, if necessary, to obtain the real dynamic stiffness s'. Dynamic stiffness depends in fact on the flow resistivity r, which is measured in the lateral direction of the sample. If the material has specific flow resistivity values, the apparent dynamic stiffness must be corrected by adding the contribution of the gas contained within the material: air.

VISCOUS SLIDING UNDER COMPRESSION – CREEP Expressed as a percentage, it is measured according to EN 1606 and represents the long-term deformation of a material under constant load to be simulated. The measurement in the laboratory must be carried out over a period of at least 90 days.

COMPRESSIBILITY - c The compressibility class expresses the behaviour of a material while subjected to screed loading. During measurement, the product is subjected to different loads and its thickness is measured. The compressibility measurement is carried out to understand what loads the underscreed product can withstand, in order to avoid cracking and splitting of screeds.

CORRECT INSTALLATION The technological solution of the floating screed is one of the most widely used and one of the most effective, but in order to achieve satisfactory results it is important that the system is designed and implemented correctly.

The resilient layer must be continuous because any gap would represent an acoustic bridge. When installing underscreed mats, care must be taken not to create discontinuities.

IIC vs Lw

It is important to use the SILENT EDGE perimeter strip to ensure that the resilient layer is continuous around the entire perimeter of the room. The SILENT EDGE should only be trimmed after the floor has been installed and grouted.

The skirting board must be installed after the SILENT EDGE has been cut, ensuring that it is always suitably raised from the floor.

IIC stands for Impact Insulation Class and is the value obtained by subtracting the noise level measured in the receiving room from the noise level measured in the source room. Impact Insulation Class, sometimes referred to as Impact Isolation Class, measures the resistance of the floor construction assembly against the propagation of impact-generated noise.

IMPACT NOISE | ACOUSTIC PROBLEMS OF FLOORS | 23


SILENT FLOOR

SOLUTIONS AGAINST IMPACT NOISE

TESTED, EFFECTIVE, VERSATILE With regard to the flooring, there is a need for underfloor insulation solutions. These are elements with the task of absorbing vibrations and this is made possible by their ability to absorb the energy released during impact on the floor. If this energy is left without barriers, it would otherwise be converted into sound waves, disturbing adjacent rooms. Our range of underscreeds offers different solutions depending on the weight of the top layers installed on the resilient products (screed thickness). Test results of all products in this family are also available in real applications with effectiveness between 30 and 40 dB. The range consists of different solutions in made of different materials depending on the intended use.

24 | SILENT FLOOR | IMPACT NOISE


EFFECTIVE The products in the range, installed with SILENT EDGE, provide a perfect, acoustically effective and watertight floating screed system.

DURABLE The materials used in the production of this product range, although so different from each other, ensure stability and durability and guarantee high resilience.

SIMPLE Thanks to the integrated adhesive strip, when present, or Rothoblaas adhesive tapes, the seamless installation of underscreed products is easy and straightforward.

SILENT FLOOR PUR

CODES AND DIMENSIONS SILENT FLOOR PUR CODE

H(1)

L

Af(2)

H(1)

L

s

Af(2)

[m]

[m] [mm] [m2]

[ft]

[ft]

[in]

[ft2]

s

SILFLOORPUR10

1,6

10

10

15

5' 3'' 32' 9 3/4'' 0.39

161

6

SILFLOORPUR15

1,6

8

15

12

5' 3''

0.59

129

6

SILFLOORPUR20

1,6

6

20

9

5' 3'' 19' 8 1/4'' 0.79

97

6

26' 3''

(1)1.5 m of agglomerate and vapour barrier + 0.1 m of vapour barrier for overlap with integrated

adhesive strip (4’ 11’’ + 3 7/8’’).

(2)Without considering the overlap area.

SILENT FLOOR TEX H(1)

L

Af(2)

H(1)

L

s

Af(2)

[m]

[m] [mm] [m2]

[ft]

[ft]

[in]

[ft2]

SILFLOORTEX6

1,10

10

6

10

3' 7 1/4'' 32' 9 3/4'' 0.24 108

SILFLOORTEX10

1,10

10

10

10

3' 7 1/4'' 32' 9 3/4'' 0.39 108

6

SILFLOORTEX15

1,10

5

15

5

3' 7 1/4'' 16' 4 7/8'' 0.59

12

CODE

s

54

12

(1)1 m of felt and vapour barrier + 0.10 m vapour barrier for overlap with integrated adhesive strip

(3’ 3 3/8’’ + 3 7/8’’).

(2)Without considering the overlap area.

SILENT FLOOR BYTUM CODE

SILFLOORBYT5

H(1)

L

Af(2)

H(1)

L

s

Af(2)

[m]

[m] [mm] [m2]

[ft]

[ft]

[in]

[ft2]

1,05

10

s

5

10 3’ 5 3/8’’ 32’ 9 3/4’’ 0.20 108

SILENT FLOOR TEX 20

(1)1 m of felt and bituminous membrane + 0.05 m of bituminous membrane for overlap (3’ 3 3/8’’ + 2’’). (2)Without considering the overlap area.

SILENT FLOOR PE CODE

H

L

s

A

H

L

s

A

[mm] [m2]

[ft]

[ft]

[in]

[ft2]

[m]

[m]

SILFLOORPE6

1,55

50

5

77,5

SILFLOORPE10

1,30

50

10

65

H

L

s

A

H

L

s

A

[m]

[m] [mm] [m2]

[ft]

[ft]

[in]

[ft2]

1,0

16

3' 3 3/8'' 52' 5 7/8'' 0.79

172

164' 1/2'' 0.20 834

4

4' 3 1/8'' 164' 1/2'' 0.39 700

2

5' 1''

SILENT FLOOR NET 3D CODE

SILTNET20

20

16

4

SILENT FLOOR PUR IMPACT NOISE | SILENT FLOOR | 25


PRODUCT COMPARISON products

integrated adhesive strip

material

SILENT FLOOR PUR

polyurethane agglomerate made from preconsumer industrial waste laminated with polyethylene vapour barrier

SILENT FLOOR BYTUM

polyester fibre felt made from postconsumer waste laminated to an elastoplastomeric bitumen waterproofing membrane

-

textile fibre felt laminated with a polyethylene vapour barrier, both made from pre-consumer industrial waste

SILENT FLOOR TEX

SILENT FLOOR PE

SILENT FLOOR NET 3D

26 | SILENT FLOOR | IMPACT NOISE

-

-

closed cell expanded polyethylene

three-dimensional mat laminated with a non-woven fabric and a three-layer breathable membrane, all made of polypropylene


thickness

dynamic stiffness

estimate ΔLw

load

according to formula C.4 of EN ISO 12354-2

10

15

20

25

30

35

32,5 dB

125 kg/m2

10 mm 0.39 in

12,5 MN/m3

35,1 dB

200 kg/m2

36,4 dB

250 kg/m2

34,6 dB

125 kg/m2

15 mm 0.59 in

40

3

8,8 MN/m

37,3 dB

200 kg/m2

38,6 dB

250 kg/m2

125 kg/m2

20 mm 0.79 in

3

7,4 MN/m

3

27 MN/m

3

33 MN/m

200 kg/m2

3

25 MN/m

20 mm 0.79 in

26,5 dB 29,2 dB 30,4 dB 28,2 dB 30,9 dB 32,1 dB

250 kg/m2

3

22 MN/m

29 dB

200 kg/m2

31,7 dB

250 kg/m2

3

43 MN/m

200 kg/m2 250 kg/m2

125 kg/m2

10 mm 0.39 in

31,6 dB

200 kg/m2

125 kg/m2

5 mm 0.20 in

30,4 dB

250 kg/m2

125 kg/m2

15 mm 0.59 in

27,7 dB

250 kg/m2

125 kg/m2

10 mm 0.39 in

39,6 dB

200 kg/m2

125 kg/m2

6 mm 0.24 in

38,4 dB

250 kg/m2

125 kg/m2

5 mm 0.20 in

35,7 dB

200 kg/m2

3

41 MN/m

21,1 MN/m3

200 kg/m2

32,9 dB 24,9 dB 27,5 dB 28,8 dB 25,2 dB 27,8 dB

250 kg/m2

29,1 dB

125 kg/m2

29,3 dB

200 kg/m2 250 kg/m2

31,9 dB 33,2 dB

IMPACT NOISE | SILENT FLOOR | 27


SILENT FLOOR PUR RESILIENT HIGH PERFORMANCE UNDERSCREED MEMBRANE MADE OF RECYCLED POLYMERS CERTIFIED The effectiveness of the underscreed membrane has been certified in the labs of the Centre for Industrial Research of the University of Bologna.

SUSTAINABILITY Recycled and recyclable. The product intelligently reuses polyurethane from production waste that would otherwise have to be disposed of.

HIGH PERFORMANCE The special composition offers excellent elasticity, reaching attenuation values over 30 dB.

COMPOSITION polyethylene vapour barrier polyurethane agglomerate made from pre-consumer industrial waste

CODES AND DIMENSIONS H(1)

L

thickness

Af(2)

H(1)

L

thickness

Af(2)

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

SILFLOORPUR10

1,6

10

10

15

5' 3''

32' 9 3/4''

0.39

161

6

SILFLOORPUR15

1,6

8

15

12

5' 3''

26' 3''

0.59

129

6

SILFLOORPUR20

1,6

6

20

9

5' 3''

19' 8 1/4''

0.79

97

6

CODE

(1)1.5 m of polyurethane agglomerate and vapour barrier + 0.1 m of vapour barrier for overlap with integrated adhesive strip (4’ 11’’ + 3 7/8’’). (2)Without considering the overlap area.

SAFE Polyurethane is a noble polymer that maintains elasticity over time, without subsidence or changes in performance.

VOC REQUIREMENTS The membrane composition safeguards health and meets the recommended VOC limits.

28 | SILENT FLOOR PUR | IMPACT NOISE


TECHNICAL DATA SILENT FLOOR PUR - 10-15-20 mm thick Properties

standard

value

USC conversion

Resistance to airflow r

ISO 9053

< 10,0 kPa·s·m-2

-

Compressibility class

EN 12431

CP2

-

CREEP Viscous sliding under compression Xct (1,5 kPa)

EN 1606

7,50 %

-

Compression deformation stress

ISO 3386-1

17 kPa

-

Thermal conductivity λ

-

0,035 W/m·K

0.020 BTU/(h·ft2 ·°F)

Specific heat c

-

1800 J/kg·K

0.43 BTU/(lb·°F)

Water vapour transmission Sd

-

> 100 m

< 0.035 US perm

Reaction to fire

EN 13501-1

class F

-

VOC emission classification

French decree no. 2011-321

A+

-

Properties

standard

value

USC conversion

Surface mass m

-

0,9 kg/m2

0.18 lb/sft

Density ρ

-

80 kg/m3

4.9 lb/ft3

Apparent dynamic stiffness s’t

EN 29052-1

12,5 MN/m3

-

EN 29052-1

12,5 MN/m3

-

ISO 12354-2

32,5 dB

-

ISO 12354-2

50,6 Hz

-

ISO 10140-3

21 dB

-

-

0,46 m2K/W

-

standard

value

USC conversion

Surface mass m

-

1,4 kg/m2

0.29 lb/sft

Density ρ

-

90 kg/m3

5.6 lb/ft3

Apparent dynamic stiffness s’t

EN 29052-1

8,8 MN/m3

-

Dynamic stiffness s’

EN 29052-1

8,8 MN/m3

-

SILENT FLOOR PUR - 10 mm thick

Dynamic stiffness s’ Theoretical estimate of impact sound pressure level attenuation ΔLw

(1)

System resonance frequency f0 (2) Impact sound pressure level attenuation ΔLw

(3)

Thermal resistance Rt

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft). 0 (3)Measured in the laboratory on 200 mm (7 7/8’’) CLT floor. See the manual for more information on configuration.

SILENT FLOOR PUR - 15 mm thick Properties

Theoretical estimate of impact sound pressure level attenuation ΔLw

(1)

ISO 12354-2

34,6 dB

-

System resonance frequency f0 (2)

ISO 12354-2

42,5 Hz

-

Impact sound pressure level attenuation ΔLw(3)

ISO 10140-3

23 dB

-

-

0,52 m2K/W

-

Thermal resistance Rt

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft). 0 (3)Measured in the laboratory on 200 mm (7 7/8’’) CLT floor. See the manual for more information on configuration.

SILENT FLOOR PUR - 20 mm thick Properties

standard

value

USC conversion

Surface mass m

-

1,8 kg/m2

0.37 lb/sft

Density ρ

-

90 kg/m3

5.6 lb/ft3

Apparent dynamic stiffness s’t

EN 29052-1

7,4 MN/m3

-

Dynamic stiffness s’

EN 29052-1

7,4 MN/m3

-

Theoretical estimate of impact sound pressure level attenuation ΔLw(1)

ISO 12354-2

35,7 dB

-

System resonance frequency f0 (2)

ISO 12354-2

38,9 Hz

-

ISO 10140-3

25 dB

-

-

0,92 m2K/W

-

Impact sound pressure level attenuation ΔLw Thermal resistance Rt

(3)

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft). 0 (3)Measured in the laboratory on 200 mm (7 7/8’’) CLT floor. See the manual for more information on configuration

IMPACT NOISE | SILENT FLOOR PUR | 29


SILENT FLOOR PUR | Tests performed SOUND REDUCTION INDEX LEVEL MEASUREMENTS Tests carried out in the Building Envelope Lab of the Free University of Bozen/Bolzano in accordance with EN ISO 10140-2 have made it possible measured the impact noise level of the construction assembly described below:

1 5

2 3

4

1

plasterboard panel

2

timber battens

3

strips of SILENT FLOOR PUR (s: 10 mm - 0.39 in)

4

OSB

5

insulation material such as rock wool

5

4

Add the supporting wall to the base frame and decouple it using strips of SILENT FLOOR PUR.

ΔRw = + 6 dB

graphs and frequency values available

ΔSTC = + 7

See the manual for more information on configuration

IMPACT NOISE LEVEL MEASUREMENTS Tests carried out in the Building Envelope Lab of the Free University of Bozen/Bolzano in accordance with EN ISO 10140-3 measured the impact noise level of the construction assembly described below:

1 2

3 1

concrete slab (s: 50 mm - 1.95 in)

2

SILENT FLOOR PUR (s: 20 mm - 0.79 in)

3

CLT panel (s: 200 mm - 7.8 in) Thanks to the addition of the floating screed system on the raw CLT.

graphs and frequency values available See the manual for more information on configuration

Use the QR-code to download the complete manual! www.rothoblaas.com 30 | SILENT FLOOR PUR | IMPACT NOISE

ΔLn,w = - 25 dB ΔIIC = + 25


MYPROJECT: FOR AN EASY ACOUSTIC COMFORT

For optimal acoustic comfort design choose MYPROJECT. In the software you will find a module dedicated to acoustic comfort and the automatic calculation of the Kij vibration reduction index. By entering load and design data, you can find the most suitable resilient profile and obtain a complete, customised calculation report. Installation on site will be easier, acoustic comfort will be above expectations.

Scan the QR code and download MYPROJECT www.rothoblaas.com


SILENT FLOOR TEX UNDERSCREED MEMBRANE MADE OF RECYCLED TEXTILE FIBRE AND RECYCLED

RECYCLED The bottom felt is composed of textile fibres derived from production waste, which are then carefully examined and selected.

ACOUSTIC PERFORMANCE Tested at the University of Bologna according to international standards for acoustic characterisation.

FAST INSTALLATION Thanks to the integrated adhesive band, installation is simplified by immediately attaching the selvedges to the overlaps.

COMPOSITION polyethylene vapour barrier made from pre-consumer industrial waste textile fibre felt made from pre-consumer industrial waste

CODES AND DIMENSIONS H(1)

L

thickness

Af(2)

H(1)

L

thickness

Af(2)

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

1,10

10

6

10

3' 7 1/4''

32' 9 3/4''

0.24

108

SILFLOORTEX10

1,10

10

10

10

3' 7 1/4''

32' 9 3/4''

0.39

108

6

SILFLOORTEX15

1,10

5

15

5

3' 7 1/4''

16' 4 7/8''

0.59

54

12

CODE

SILFLOORTEX6

12

(1)1 m felt and vapour barrier + 0.10 m vapour barrier for overlap with integrated adhesive strip (3’ 3 3/8’’ + 3 7/8’’) (2)Without considering the overlap area.

WATERPROOF Thanks to the polyethylene top layer, the product is perfectly impermeable to water and water vapour.

THE RANGE Different thicknesses and thus technical specifications allow it to be used in different areas and for different screed thickness.

32 | SILENT FLOOR TEX | IMPACT NOISE


TECHNICAL DATA SILENT FLOOR TEX - thickness 6 mm Properties

standard

value

Thickness

-

6 mm

USC conversion 0.24 inch

Density ρ

-

approx. 90 kg/m3

5.6 lb/ft3

Resistance to airflow r

ISO 9053

16,4 kPa·s·m-2

-

Apparent dynamic stiffness s’t

EN 29052-1

18,2 MN/m3

-

Dynamic stiffness s’

EN 29052-1

33 MN/m3

-

Compressibility class

EN 12431

CP2

-

Theoretical estimate of impact sound pressure level attenuation ΔLw(1)

ISO 12354-2

26,5 dB

-

System resonance frequency f0 (2)

ISO 12354-2

82,2 Hz

-

Water vapour transmission Sd

EN ISO 12572

approx. 20 m

approx. 0.17 US perm

Properties

standard

value

USC conversion

Thickness

-

10 mm

0.39 inch

Density ρ

-

approx. 80 kg/m3

4.9 lb/ft3

Resistance to airflow r

ISO 9053

31,5 kPa·s·m-2

-

Apparent dynamic stiffness s’t

EN 29052-1

12,8 MN/m3

-

Dynamic stiffness s’

EN 29052-1

25 MN/m3

-

Compressibility class

EN 12431

CP3

-

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft) 0

SILENT FLOOR TEX - 10 mm thick

Theoretical estimate of impact sound pressure level attenuation ΔLw

(1)

ISO 12354-2

28,2 dB

-

System resonance frequency f0 (2)

ISO 12354-2

71,6 Hz

-

Water vapour transmission Sd

EN ISO 12572

approx. 20 m

approx. 0.17 US perm

Properties

standard

value

USC conversion

Thickness

-

15 mm

0.59 inch

Density ρ

-

approx. 100 kg/m3

6 lb/ft3

Resistance to airflow r

ISO 9053

24,4 kPa·s·m-2

-

Apparent dynamic stiffness s’t

EN 29052-1

12,8 MN/m3

-

Dynamic stiffness s’

EN 29052-1

22 MN/m3

-

Compressibility class

EN 12431

CP3

-

Theoretical estimate of impact sound pressure level attenuation ΔLw(1)

ISO 12354-2

29 dB

-

System resonance frequency f0 (2)

ISO 12354-2

67,1 Hz

-

Water vapour transmission Sd

EN ISO 12572

approx. 20 m

approx. 0.17 US perm

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft) 0

SILENT FLOOR TEX - 15 mm thick

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft) 0

PERFORMANCE Theoretical estimate of impact sound pressure level reduction

ΔLw : 29 dB (for 15 mm thickness)

See the manual for more information.

IMPACT NOISE | SILENT FLOOR TEX | 33


SILENT FLOOR BYTUM RESILIENT UNDERSCREED MEMBRANE MADE OF BITUMEN AND POLYESTER FELT

TESTED EFFECTIVENESS The special structure absorbs vibrations from impact noise up to 20 dB.

STRUCTURAL RESTORATION The material and special structure of the product make it extremely safe even in applications in historic or valuable buildings, as it prevents the screed from percolating in applications with timber and concrete connectors.

HERMETIC Thanks to the bituminous mixture the membrane tends to close around the fastening system, ensuring watertightness.

COMPOSITION elastoplastomeric bitumen waterproofing membrane polyester fibre felt made from post-consumer waste

CODES AND DIMENSIONS CODE

SILFLOORBYT5

H(1)

L

thickness

Af(2)

H(1)

L

thickness

Af(2)

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

1,05

10

5

10

3’ 5 3/8''

32’ 9 3/4’’

0.20

108

20

(1)1 m bituminous membrane with felt + 0.05 m bitumen membrane for overlap (3’ 3 3/8’’ + 2’’). (2)Without considering the overlap area.

DURABLE Stable over time, thanks to the bituminous mixture. Also highly compatible with fresh concrete.

TIMBER-TO-CONCRETE Ideal in combination with CTC connectors. Stiffness values also calculated in the presence of vapour barrier sheet or soundproofing layer.

34 | SILENT FLOOR BYTUM | IMPACT NOISE


TECHNICAL DATA Properties

standard

value

USC conversion 0.20 inch

Thickness

-

approx. 5 mm(1)

Surface mass m

-

1,5 kg/m2

0.30 lb/sft

Density ρ

-

300 kg/m2

18.7 lb/ft3 -

Resistance to airflow r

ISO 9053

> 100,0 kPa·s·m-2

Apparent dynamic stiffness s’t

EN 29052-1

7 MN/m3

-

Double layer apparent dynamic stiffness(2) s't

EN 29052-1

4 MN/m3

-

Dynamic stiffness s’

EN 29052-1

27 MN/m3

-

Double layer dynamic stiffness(2) s'

EN 29052-1

14,5 MN/m3

-

Compressibility class

EN 12431

CP2 (≤ 2 mm)

approx. 0.17 US perm

Double layer compressibility class(2)

EN 12431

CP3 (≤ 3 mm)

-

CREEP Viscous sliding under compression Xct (2 kPa)

EN 1606

≤ 1 mm

-

CREEP Viscous sliding under compression double layer(2) Xct (2 kPa)

EN 1606

≤ 1 mm

-

Theoretical estimate of the impact sound pressure level attenuation ΔLw(3)

ISO 12354-2

27,7 dB

-

System resonance frequency f0 (4)

ISO 12354-2

74,4 Hz

-

Impact sound pressure level attenuation ΔLw(5)

ISO 10140-3

20 dB

-

Impact sound pressure level attenuation ΔLw(5) double layer(2)

ISO 10140-3

21 dB

-

Thermal resistance Rt

ISO 6946

Thermal conductivity λ

-

Specific heat c

-

0,13 m2K/W 0,045 W/m·K 0,17 W/m·K 1,3 kJ/kg·K

0.026 BTU/(h·ft2 ·°F) 0.098 BTU/(h·ft2 ·°F) 0.31 BTU/(lb·°F)

Water vapour resistance factor μ

EN 12086

100000

2500 MN·s/g

Water vapour transmission Sd

-

> 100 m

< 0.035 US perm

(1)2 mm bituminous membrane + 3 mm felt (0.08 in + 0.12 in). | (2)With opposing white felts. | (3)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] with m’= 125 kg/m2 (25.60 lb/sft). | w (4)f = 160 √(s’/m’) with m’= 125 kg/m2 (25.60 lb/sft). | (5)Measured in the laboratory on 200 mm (7 7/8’’) CLT floor. See the manual for more information on configuration. 0

SOUND REDUCTION INDEX LEVEL AND IMPACT NOISE LEVEL MEASUREMENTS Tests carried out in the Akustik Center Austria laboratories of the Holzforschung Austria association in accordance with EN ISO 10140-2 and EN ISO 10140-3 made it possible to measure the soundproofing and impact noise level of the construction assembly described below: 1

concrete screed (s: 60 mm - 2.4 in)

2

BARRIER 100

3

mineral wool insulation (s: 30 mm - 1.2 in)

4

compacted gravel fill with cement (s: 80 mm - 3.2 in)

1 2

4 5

5

SILENT FLOOR BYTUM (s: 5 mm - 0.2 in)

6

CLT (s: 160 mm - 6.4 in)

7

metal structure for plasterboard

8

air chamber (s: 10 mm - 0.39 in)

9

low density mineral wool insulation (s: 50 mm - 2.0 in)

10

2 plasterboard panels (s: 25 mm - 1.0 in)

graphs and frequency values available

3

6

7

8

9 10

Ln,w(Cl) = 42 (0) dB

Rw(C;Ctr) = 60 (-1;-4) dB

IICASTM = 42

STCASTM = 59

See the manual for more information on configuration.

Use the QR-code to download the complete manual! www.rothoblaas.com IMPACT NOISE | SILENT FLOOR BYTUM | 35


SILENT FLOOR PE RESILIENT UNDERSCREED MEMBRANE MADE OF CLOSED CELL PE

CLOSED CELL Thanks to the grid of closed cell polyethylene, the foil will not permanently deform and remains effective over time.

COST-PERFORMANCE Composition of the mixture optimised to provide both good performance and low cost.

VERSATILE This product is a versatile solution in any application where a light and flexible resilient product is required.

COMPOSITION closed cell expanded polyethylene

CODES AND DIMENSIONS CODE

H

L

thickness

A

H

L

thickness

A

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

SILFLOORPE6

1,55

50

5

77,5

5' 1''

164' 1/2''

0.20

834

4

SILFLOORPE10

1,30

50

10

65

4' 3 1/8''

164' 1/2''

0.39

700

2

SEVERAL USES The format and composition offer various uses in the construction field, also as under floor.

STABLE The grid of polyethylene foam is durable and does not suffer from issues associated with chemical actions or incompatibility of materials.

36 | SILENT FLOOR PE | IMPACT NOISE


TECHNICAL DATA SILENT FLOOR PE - 5-10 mm thick Properties

standard

value

USC conversion

Density ρ

-

30 kg/m3

1.9 lb/ft3

Resistance to airflow r Thermal conductivity λ VOC emission classification

ISO 9053 French decree no. 2011-321

> 100.0 kPa·s·m-2 0,038 W/m·K 0.022 BTU/(h·ft2 ·°F) A+ -

SILENT FLOOR PE - 5 mm thick Properties

standard

value

USC conversion

Thickness Surface mass m Apparent dynamic stiffness s’t Dynamic stiffness s’ Theoretical estimate of impact sound pressure level attenuation ΔLw(1) System resonance frequency f0 (2) Impact sound pressure level attenuation ΔLw(3) Thermal resistance Rt Water vapour transmission Sd Water vapour resistance factor μ

EN 29052-1 EN 29052-1 ISO 12354-2 ISO 12354-2 ISO 10140-3 EN 12086

5 mm 0,15 kg/m2 43 MN/m3 43 MN/m3 24,9 dB 93,8 Hz 19 dB 0,13 m2K/W 24,1 m 5000

ca. 0.20 in 0.03 lb/sft 125 MN·s/g

Properties

standard

value

USC conversion

Thickness Surface mass m Apparent dynamic stiffness s’t Dynamic stiffness s’ Theoretical estimate of impact sound pressure level attenuation ΔLw(1) System resonance frequency f0 (2) Impact sound pressure level attenuation ΔLw(3) Thermal resistance Rt Water vapour transmission Sd Water vapour resistance factor μ

EN 29052-1 EN 29052-1 ISO 12354-2 ISO 12354-2 ISO 10140-3 EN 12086

10 mm 0,30 kg/m2 41 MN/m3 41 MN/m3 25,2 dB 91,6 Hz 0,26 m2K/W 48,2 m 5000

ca. 0.39 in 0.06 lb/sft 250 MN·s/g

SILENT FLOOR PE - 10 mm thick

(1) ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] with m’= 125 kg/m2 (25.60 lb/sft). w (2) f = 160 √(s’/m’) with m’= 125 kg/m2 (25.60 lb/sft). 0 (3) Measured in the laboratory on 200 mm (7 7/8’’) CLT floor. See the manual for more information on configuration.

IMPACT NOISE LEVEL MEASUREMENTS Tests carried out in the Building Envelope Lab of the Free University of Bozen/Bolzano in accordance with EN ISO 10140-3 measured the impact noise level of the construction assembly described below:

1

1

concrete slab (s: 50 mm - 2.0 in)

2

SILENT FLOOR PE (s: 5 mm - 0.2 in)

3

CLT panel (s: 200 mm - 8.0 in)

2

- 19 dB

3

compared to the basic configuration Thanks to the addition of the floating screed system on the raw CLT.

graphs and frequency values available

Ln,w = - 19 dB

See the manual for more information on configuration

IICASTM = + 19 dB

Use the QR-code to download the complete manual! www.rothoblaas.com IMPACT NOISE | SILENT FLOOR PE | 37


SILENT FLOOR NET 3D BREATHABLE MEMBRANE WITH THREEDIMENSIONAL RESILIENT MAT

SOUNDPROOFING The special structure of the three-dimensional mat ensures a reduction in impact noise by acting as a resilient layer.

PROTECTIVE FELT The fabric protects the three-dimensional mesh from impurities or processing residues that would compromise its functionality.

HIGH DENSITY 3D GRID The three-dimensional mat has a high mechanical resistance while maintaining the functionality of the product even after the installation and construction phase.

COMPOSITION breathable three-layer polypropylene membrane 3-dimensional polypropylene mat non-woven polypropylene fabric

CODES AND DIMENSIONS CODE

SILTNET20

H

L

thickness

A

H

L

thickness

A

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

1,0

16

20

16

3’ 3 3/8’’

52’ 5 7/8’’

0.79

172

3

BREATHABLE The product consists of a three-layer membrane that ensures breathability, air and water impermeability even during installation.

VERSATILE It can also be used as a micro-ventilation layer in both wall and roof, keeping adjacent layers dry and improving thermo-acoustic performance.

38 | SILENT FLOOR NET 3D | IMPACT NOISE


TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

20 mm

0.79 in

Surface mass m

-

1 kg/m2

0.21 lb/sft

Density ρ

-

50 kg/m3

30 lb/ft3

Resistance to airflow r

ISO 9053

< 10,0 kPa s m-2

-

Apparent dynamic stiffness s’t (3)

EN 29052-1

21,1 MN/m3

-

Dynamic stiffness s’ (3)

EN 29052-1

21,1 MN/m3

-

Apparent dynamic stiffness s’t (4)

EN 29052-1

29,9 MN/m3

-

Dynamic stiffness s’ (4)

EN 29052-1

29,9 MN/m3

-

Compressibility class

EN 12431

CP2

-

Theoretical estimate of impact sound pressure level attenuation ΔLw(1)

ISO 12354-2

29,3 dB

-

System resonance frequency f0 (2)

ISO 12354-2

65,6 Hz

-

Thermal conductivity λ

-

0,3 W/(m·K)

0.020 BTU/(h·ft2 ·°F)

Specific heat c

-

1800 J/(kg·K)

0.43 BTU/(lb·°F)

Watertightness

EN 1928

class W1

-

Water vapour transmission Sd

EN ISO 12572

0,03 m

116 US perm

Reaction to fire

EN 13501-1

E

-

(1)ΔL = (13 lg(m’))-(14,2 lg(s’))+20,8 [dB] con m’= 125 kg/m2 (25.60 lb/sft). w (2)f = 160 √(s’/m’) con m’= 125 kg/m2 (25.60 lb/sft). 0 (3)Dynamic stiffness value that can be used for creating dry floating screeds (e.g. fiber plaster slabs). (4)Dynamic stiffness value for creating sand and cement-based floating screeds.

WHAT ABOUT ROOFS? TRASPIR METAL IS FOR THREE Tested, certified and unique, TRASPIR METAL is the 3D mesh insulation solution for reducing airborne noise and heavy rain. The product line consists of three-dimensional metal roofing mats with high mechanical strength and excellent protective capacity. TRASPIR 3D COAT TT and 3D NET are composed of materials that promote micro-ventilation and block the entry of impurities into the cover. Both available with a waterproof lower membrane and with draining TNT upper membrane. Read more on page 70.

PERFORMANCE Theoretical estimate of impact sound pressure level reduction

ΔLw : 29,3 dB

See the manual for more information.

IMPACT NOISE | SILENT FLOOR NET 3D | 39


SILENT EDGE SELF-ADHESIVE STRIP FOR PERIMETER SEPARATION

PRACTICAL Thanks to the self-adhesive backing, the pre-cut in the liner and the milling, application is fast and precise. Available in different versions.

EXCELLENT PERFORMANCE Together with SILENT FLOOR range, it creates a highly soundproof floating screed.

SPECIAL ADHESIVE The special adhesive compound with hotmelt technology is particularly resistant even in high humidity or stagnant water.

CODES AND DIMENSIONS VERSION WITH POLYETHYLENE STRAP CODE

SILEDGEH150

s [mm] [in] 6 0.24

B1 [mm] [in] 50 2''

B2 [mm] [in] 175 6 7/8''

H1 [mm] [in] 100 3 7/8''

H2 [mm] [in] 25 1''

L pcs [m] [ft] 50 1 164' 1/2''

B2 H1 H2 B1

UNIVERSAL VERSION CODE

s

B

[mm] [mm]

H

L

s

B

H

L

[mm] [m]

[in]

[in]

[in]

[ft]

pcs H

SILEDGE150

6

50

100

50 0.24

2''

3 7/8''

164' 1/2''

1

SILEDGE240

6

50

190

50 0.24

2''

7 1/2''

164' 1/2''

1 B

WATERPROOF Thanks to the closed cell structure, it is airtight and waterproof even if cut or trimmed after application.

VERSATILE Ideal as a perimeter band in floors undergoing structural renovation and in new buildings.

40 | SILENT EDGE | IMPACT NOISE


CERTAIN COLLABORATIONS ARE BORN TO LAST

CTC is the connector for timber-to-concrete floors. CE certified, it allows to connect a 5 or 6 cm reinforced concrete slab to the timber beams of the underneath floor, obtaining a new timber-concrete structure with extraordinary strength and excellent static and acoustic performance. It is an approved self-drilling, reversible, fast and minimally invasive system.

Scan the QR code and discover the technical features of CTC connector www.rothoblaas.com


SILENT FLOOR | Recommendations for installation PERIMETER STRIP INSTALLATION

1

2

3

4

5

6

7

8

42 | SILENT FLOOR | Recommendations for installation | IMPACT NOISE


SINGLE-LAYER UNDERSCREED MEMBRANE INSTALLATION

1

2

3

4

6

7

5

DOUBLE-LAYER UNDERSCREED MEMBRANE INSTALLATION

1

2 IMPACT NOISE | SILENT FLOOR | Recommendations for installation | 43


UNDERFLOOR IMPACT-ABSORBING MATS WHAT ARE THEY FOR? Underfloor impact-absorbing mats are the connection between the finish and the respective substrate. In addition to their soundproofing function, they must ensure that the floor can be installed easily and effectively. EN 16354 specifies test methods to determine the technical properties of the underfloor mat for use under laminate floors and contains minimum performance requirements for the underfloor system to work effectively.

MECHANICAL REQUIREMENTS COMPENSATION CAPACITY - PC It is the product's ability to compensate for any unevenness in the substrate on which it is installed and thus eliminate unevenness. In general, the softer the mat, the greater its compensating capacity. This capacity is evaluated by measuring SHORE A according to EN ISO 868 and is expressed in mm. This is a very important property, especially when working on existing sites or working on sites that are not very clean.

COMPRESSION STRENGTH - CS In order to ensure the integrity of the flooring, the compressive force, expressed in kPa, which causes a deformation of 0,5 mm, according to EN 826, must be determined. The greater the pressure necessary to obtain deformation, the better the product’s resistance to compression.

DYNAMIC LOAD RESISTANCE - DL25 In order to ensure the integrity of the flooring even under long-term dynamic loads, the Dynamic Load Resistance must be determined according to EN 13793. The DL 25 value indicates the number of cycles the material can withstand before reaching a thickness loss ≤ 0.5 mm. Clearly, the higher the number of cycles, the better the strength of the material.

ACOUSTIC REQUIREMENTS IMPACT SOUND NOISE INSULATION - IS The measurement of the reduction of the impact sound pressure level must be carried out in the laboratory according to EN ISO 10140-3. The index expresses the difference in decibels between the measurement of the impact sound pressure level of the construction assembly with the impact-absorbing mat and the measurement without the insertion of the product.

AIRBORNE NOISE INSULATION- AS The measurement of the apparent soundproofing index Rw' must be carried out in the laboratory according to EN ISO 10140-2. It characterises the ability of the partition to limit the passage of airborne noise between two rooms.

INSULATION AGAINST REFLECTED NOISE - RWS The "drum sound" indicates the noise level that is perceived in the room when an impact-type source, such as footsteps, acts on the floor surface of the same room. It is measured in "sone", the higher the RWS value, the less reverberation is perceived within the room.

PROTECTION AGAINST FALLING OBJECTS - RLB The floor has the capacity to absorb high forces of short duration, such as shocks from falling objects. Measured in cm, the higher the RLB value, the higher the level of floor protection.

44 | UNDERFLOOR IMPACT-ABSORBING MATS | IMPACT NOISE


SILENT STEP HIGH DENSITY POLYETHYLENE SUBSTRATE WITH VAPOUR BARRIER FILM

PRACTICAL Thanks to the integrated adhesive tape, sealing is immediate and doesn't require any additional sealing tape.

DAMP BARRIER The polyethylene film coating prevents the passage of humidity Sd > 75 m, protecting the floor.

CODES AND DIMENSIONS CODE

SILENTSTEP

H(1)

L

thickness

Af(2)

H(1)

L

thickness

Af(2)

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

1,10

15

2

15

3' 7 1/4''

49' 2 1/2''

0.08

161

20

(1)1 m roll + 0.10 m overlap with integrated adhesive strip (3’ 7 1/4 + 3 7/8’’). (2)Without considering the overlap area.

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

2 mm

0.08 in

Surface mass m

-

0,001 kg/m2

0.0002 lb/sft

Density ρ

-

0,5 kg/m3

0.03 lb/ft3

Water vapour transmission Sd

EN 12086

≥ 75 m

≤ 0.047 US perm

Soundproofing of reflected RWS noise

EN 16205

25 sones

-

Compression strength CS

EN 826

30 kPa

-

CREEP viscous sliding under compression CC (10 kPa)

EN 1606

< 0,5 mm

-

Dynamic load resistance DL 25

EN 13793

10000 cycles -

Thermal resistance Rt

-

0,06 m2K/W

-

Impact resistance (Large ball test) RLB(1)

EN 13329

1200 mm

-

Reaction to fire

EN 13501-1

class F

-

VOC emission classification

French decree no. 2011-321

A+

-

(1)Under 7 mm (0.28 inch) laminate.

FIELDS OF APPLICATION FLOOR INSTALLATION floating (not glued) FLOOR TYPE parquet LVT (medium high quality) laminate IN-FLOOR HEATING suitable

IMPACT NOISE | SILENT STEP | 45


SILENT STEP ALU

Bfl-s1

HIGH DENSITY POLYMER SUBSTRATE COVERED IN ALUMINIUM WITH AS A VAPOUR BARRIER FILM HIGH PERFORMANCE Coated with an aluminised vapour barrier to protect against rising damp.

REFLECTIVE Thanks to its extremely heat-conducting material, it is specifically designed for the floating installation of parquet and laminates, even on radiant floors.

CODES AND DIMENSIONS CODE

SILENTSTEPA

H

L

thickness

A

H

L

thickness

A

[m]

[m]

[mm]

[m2]

[ft]

[ft]

[in]

[ft2]

1,0

8,5

1,8

8,5

3' 3 3/8''

27' 10 5/8''

0.07

91

40

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

1,8 mm

0.07 in

Surface mass m

-

1 kg/m2

0.20 lb/sft

Density ρ

-

approx. 555 kg/m3

34.6 lb/ft3

Water vapour transmission Sd

EN 12086

≥ 150 m

≤ 0.023 US perm

Soundproofing of reflected RWS noise

EN 16205

23 sones

-

Compression strength CS

EN 826

300 kPa

-

CREEP viscous sliding under compression CC (10 kPa)

EN 1606

< 0,5 mm

-

Dynamic load resistance DL 25

EN 13793

100000 cycles

-

-

0,01 m2K/W

-

Thermal resistance Rt Impact resistance (Large ball test) RLB(1)

EN 13329

< 600 mm

-

Reaction to fire

EN 13501-1

Bfl-s1 class

-

VOC emission classification

French decree no. 2011-321

A+

-

(1)Under 7 mm (0.28 inch) laminate.

FIELDS OF APPLICATION FLOOR INSTALLATION floating (not glued) FLOOR TYPE parquet LVT (medium high quality) laminate IN-FLOOR HEATING suitable

46 | SILENT STEP ALU | IMPACT NOISE


PIANO A RESILIENT SOUNDPROOFING PROFILE

LIGHTWEIGHT FLOORS The profile, thanks to its low dynamic stiffness and the fact that it can be divided into two thinner sizes, proves effective in reducing vibrations even in floors with little mass.

ACOUSTIC PERFORMANCE TESTED The profile was tested in combination with the ribbing strips of the lightweight floors, resulting in an improvement of up to 7dB.

CODES AND DIMENSIONS CODE

B [mm]

L [m]

s [mm]

B [in]

L [ft]

s [in]

pcs

PIANOA4040

80

10

6

3’ 1/8’’

33

1/4

1

PIANOA5050

100

10

6

4

33

1/4

1

PIANOA6060

120

10

6

4’ 3/4’’

33

1/4

1

PIANOA140

140

10

6

5 ‘1/2’’

33

1/4

1

For more information about the product see page 109.

IMPACT NOISE LEVEL MEASUREMENTS PIANO A is a resilient profile that works with low loads, which is why its effectiveness was also tested as a separating profile for dry floor ribs at the University of Innsbruck. addition of the dry system with PIANO

- 31 dB Ln,w = 84 dB IICASTM = 26

addition of dry system without PIANO

- 7 dB Ln,w = 53 dB

Ln,w = 60 dB

IICASTM = 57

IICASTM = 50

Graphs and frequency values available. See the manual for more information on configuration.

COMPLETE RANGE Different versions are available to cover a wide load range: from floating floors to multi-storey buildings.

ANTI-VIBRATION SUPPORT Easily cut for use as a PAD under raised floors and point elements.

IMPACT NOISE | PIANO A | 47


SILENT UNDERFLOOR RESILIENT STRIP FOR FLOOR UNDERBATTENS AND SUPPORTING WALLS

PRACTICAL Easy to apply adhesive Strip, also with the aid of LIZARD unwinder.

SMART While acoustically decoupling the ribs of the substructure of a counter-wall, it also acts as a nail sealing tape at the perforations.

CODES AND DIMENSIONS CODE

SILENTUNDER50

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

50

30

4

2''

98' 5 1/8''

0.16

5

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

4 mm

0.16 in

Surface mass m

-

0,56 kg/m2

0.12 lb/sft

Density ρ

ISO 845-95

140 kg/m3 ±15%

8.7 lb/ft3

Water absorption

ASTM D1056-00

< 10%

-

Tear strength

ISO 1798-7

> 400 kN/m2

-

Elongation at failure

ISO 1798-7

> 180%

-

Compression strength

ASTM D1056

25% compression: 40 kPa 50% compression: 105 kPa

-

Increase of sound reduction index ΔRw(1)

ISO 10140-2

4 dB

-

UV-resistant

-

excellent

-

Resistance to temperature

-

-40 / +90 °C

-40 / +194 °F

(1)Measured in the laboratory on 100 mm (3 7/8’’) CLT wall. See the manual for more information on configuration.

PERFORMANCE Increase of sound insulation

ΔRw = 4 dB See the manual for more information on configuration.

MATERIAL Expanded EPDM with acrylic glue and silicone paper liner. Does not contain harmful substances.

48 | SILENT UNDERFLOOR | IMPACT NOISE


GRANULO RESILIENT GRANULAR RUBBER SOUNDPROOFING PRODUCT

THREE FORMATS Available in sheet (GRANULOMAT 1,25 x 10 m), roll (GRANULOROLL and GRANULO100) or pad (GRANULOPAD 8 x 8 cm). Extremely versatile thanks to the variety of formats.

TESTED GRANULO has been tested as a separating product under raised floors, even in working environments where high acoustic performance is required.

CODES AND DIMENSIONS CODE

B

L

s

B

L

s

pcs

[mm]

[m]

[mm]

[in]

[ft]

[in]

GRANULO100

100

15

4

4

9/16

3/16

1

GRANULOPAD

80

0,08

10

3 1/8

3 1/8

3/8

20

GRANULOROLL

80

5

8

3 1/8

19.7

5/16

1

GRANULOMAT

1250

10

6

49 3/16

33

1/4

1

s B

LABORATORY TESTING GRANULO was tested within the experimental campaign of the BIGWOOD research project in combination with solutions for inspectable floors.

8 configurations tested with GRANULO proven effectiveness The data are published at www.bigwood.projects.unibz.it.

ANTI-VIBRATION The thermal-bonded rubber granules dampen vibrations, thus insulating the noise produced by footsteps. Also ideal as a wall barrier and resilient strip for acoustic separation.

VERSATILE Ideal as a substrate for timber, aluminium, WPC and PVC structures. It can also be used outdoors.

IMPACT NOISE | GRANULO | 49


STRIPS | Recommendations for installation APPLICATION WITH PRIMER SPRAY

1a

1b

2

3

APPLICATION WITH DOUBLE BAND

1

2

3

4

50 | STRIPS | Recommendations for installation | IMPACT NOISE


PAD | Recommendations for installation APPLICATION UNDER BATTENS

1

2

3

4

APPLICATION UNDER RAISED FLOOR

1

2

3

4 IMPACT NOISE | PAD | Recommendations for installation | 51



AIRBORNE NOISE


AIRBORNE NOISE


3

AIRBORNE NOISE SILENT WALL BYTUM SA SOUNDPROOFING AND WATERPROOFING SELF-ADHESIVE BITUMINOUS MEMBRANE . . . . . . . . . . . . . . . . . . 60

SILENT WALL BYTUM SOUNDPROOFING AND WATERPROOFING BITUMINOUS MEMBRANE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

SILENT GIPS THERMAL-ACOUSTIC DECOUPLING TAPE FOR PLASTERBOARD STRUCTURES. . . . . . . . . . . . . . . . . . . . . . . . . 65

GIPS BAND SINGLE-SIDED NAIL POINT SEALANT TAPE . . . . . . . . . . . . . . . . . . 66

CONSTRUCTION SEALING COMPRESSIBLE SEALING GASKET FOR REGULAR JOINTS. . . . . 67

TRASPIR METAL 3D MATS FOR METAL ROOFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

AIRBORNE NOISE | 55


WALL ACOUSTIC PROBLEMS

WHAT IS AIRBORNE NOISE? Airborne noise is a set of sound waves that originates in the air and is then transmitted into adjacent rooms either by air or by structure. This is the main problem to be solved when designing vertical partitions in buildings.

AIRBORNE NOISE TRANSMISSION AND POSSIBLE SOLUTIONS The purpose of soundproofing measures is to minimise the transmission of sound from one room to another.

Airborne noise is transmitted to adjacent rooms either by air or by structure, following the paths represented by the arrows (lateral transmission see page 84).

The floor assembly reduces noise propagation through the ceiling (see page 22). The use of resilient decoupling profiles reduces the propagation of airborne and structural noise (see page 86).

The correct design of partition walls and of any false ceilings makes it possible to attenuate all types of noise propagation by preventing the transmission of airborne noise generated in the environment.

HOW DO YOU MEASURE SOUND REDUCTION INDEX?

microphone

The measurement is performed by activating a specific noise source in the emitting environment and measuring the sound pressure levels in both environments (emitter and receiver). The sound reduction index is given by the difference of the two measured levels. Therefore, the higher the Rw value, the better the acoustic performance of the construction assembly.

microphone

source sound EMITTER

RECEIVER

56 | WALL ACOUSTIC PROBLEMS | AIRBORNE NOISE

SOUND SOURCE


SOUND REDUCTION INDEX... WHAT DOES IT MEAN “IN PRACTICE”? ?

Sound reduction index is the ability to reduce noise transmission between one room and another. Sound insulation allows noise thresholds to be controlled and makes the building pleasant and comfortable.

a normal conversation can be easily heard and understood

25 dB

great attention is required to listen and understand a loud conversation a loud conversation can be heard but not understood

45 dB a loud conversation cannot be heard or understood

35 dB 20

30

40

a loud conversation can be easily heard and understood

a loud conversation is perceived as a murmur

30 dB

42 dB

50

53 dB

60 [dB]

only some loud conversations are audible

48 dB

SOUND REDUCTION INDEX R VS APPARENT SOUND REDUCTION INDEX R'

Dd

STC

ASTC

R

R’

Sound reduction index (R) is the performance of a partition

The apparent sound r eduction index (R'), on the other hand, indicates the performance

measured in a test laboratory

Dd Ff

Fd Df

measured on site

The acoustic laboratories are constructed in such a way that the chambers are completely decoupled from each other, so that lateral transmissions are completely eliminated. For the same construction assembly and installation, the performance measured in the laboratory will therefore be better than the performance measured on site.

IMPORTANCE OF DETAILS In acoustic design, as in other fields, the design and correct implementation of details is very important. It is counter productive to design a high-performing construction assembly if discontinuities are neglected (holes, structure-to-doors/windows connection, wall intersections, etc.). Best practice that: to increase the sound reduction index of a wall constructed of several elements, the sound reduction index of the weakest element should be increased.

Rw vs STC

STC stands for Sound Transmission Classification. It indicates the sound reduction index of a construction assembly by evaluating sound sources with frequencies between 125 and 4000 Hz. The higher the number, the better the performance.

AIRBORNE NOISE | WALL ACOUSTIC PROBLEMS | 57


SILENT WALL

SOLUTIONS FOR AIRBORNE NOISE

TESTED RESULTS AND FAST DRY INSTALLATION The entire range of soundproofing membranes ensures good acoustic performance even when installed dry and without invasive intervention. Developed in different versions and with different materials from bitumen to polyethylene, the membranes offer high soundproofing properties and are lead free. Some of these are equipped with an adhesive surface to facilitate installation even on floors or suspended ceilings. The products have been tested and provide soundproofing increase of up to 5 dB.

58 | SILENT WALL | AIRBORNE NOISE


CODES AND DIMENSIONS SILENT WALL BYTUM SA CODE

SILWALLSA

H

L

[m]

[m]

1

8,5

s

A

H

L

s

A

[mm] [m2]

[ft]

[ft]

[in]

[ft2]

4

8,5 3' 3 3/8'' 27' 10 5/8'' 0.16

91

s

A

H

L

s

A

[ft]

[ft]

[in]

[ft2]

3' 3 3/8'' 16’ 4 7/8’’ 0.17

65

24

SILENT WALL BYTUM CODE

SILWALL

H

L

[m]

[m]

[mm] [m2]

1,2

5

4,2

6

s

30

SILENT WALL SURFACE CODE

SILWALLSUR

H

L

A

H

L

s

A

[m]

[m] [mm] [m2]

[ft]

[ft]

[in]

[ft2]

-

-

-

-

-

-

-

-

-

See website www.rothoblaas.com.

PRODUCT COMPARISON

SILENT WALL BYTUM integrated adhesive strip

SILENT WALL BYTUM SA

SILENT WALL SURFACE

-

thickness

4,2 mm 0.17 in

4,0 mm 0.16 in

3,0 - 30,0 mm 0.12 in - 1.18 in

mass

6 kg/m2 1.2 lbf/ft2

5 kg/m2 1.0 lbf/ft2

20-50 kg/m2 1.2 lbf/ft2 - 3.1 lbf/ft2

ΔR = + 8 dB w

ΔR = + 8 dB w

-

soundproofing by mass addition

soundproofing by mass addition

see website www.rothoblaas.com

bitumen

bitumen

polyester felt

acoustic values

material indoor use

-

outdoor use airborne noise reverberation

-

-

AIRBORNE NOISE | SILENT WALL | 59


SILENT WALL BYTUM SA SOUNDPROOFING AND WATERPROOFING SELF-ADHESIVE BITUMINOUS MEMBRANE

NOISE REDUCTION Due to its high surface mass (5 kg/m2), the membrane absorbs up to 27 dB. Also tested in different configurations at the University of Bolzano.

SELF-ADHESIVE Thanks to its self-adhesive side, installation of the membrane is fast and precise in both horizontal and vertical applications and without mechanical fastening.

PRACTICAL The pre-cut removable film makes the sound-insulating membrane easier to install.

COMPOSITION non-woven polypropylene fabric waterproofing membrane made of elastoplastomeric bitumen adhesive removable silicone film

CODES AND DIMENSIONS CODE

SILWALLSA

H

L

thickness

surface mass

A

H

L

thickness

surface mass

A

[m]

[m]

[mm]

[kg/m2]

[m2]

[ft]

[ft]

[in]

[lb/sft]

[ft2]

1

8,5

4

5

8,5

3' 3 3/8''

27' 10 5/8''

0.16

1.02

91

24

HERMETIC Watertight and airtight, sealing of penetrations for mechanical fasteners is not required.

WITHOUT LEAD Made of self-adhesive elastoplastomeric bitumen, it does not contain lead or harmful substances.

60 | SILENT WALL BYTUM SA | AIRBORNE NOISE


TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

4 mm

0.16 in

Surface mass m

-

5 kg/m2

1.02 lb/ft2

Density ρ

-

1250 kg/m3

78.03 lb/ft3

Resistance to airflow r

ISO 9053

> 100 kPa·s·m-2

-

-

> 85000 Hz

-

Critical frequency Increase of sound reduction index ΔRw

(1)

ISO 10140-2

4 dB

-

Vibration damping - loss factor η (200 Hz)

ASTM E756

0,26

-

Thermal resistance Rt

-

0,023 m2K/W

-

Thermal conductivity λ

-

0,17 W/m·K

0.098 BTU/(h·ft2 ·°F)

Specific heat c

-

1200 J/kg·K

0.29 BTU/(lb·°F)

Water vapour resistance factor μ

EN 12086

100000

2000 MN·s/g

Water vapour transmission Sd

-

approx. 400 m

ca. 0.009 US perm

Reaction to fire

EN 13501-1

class E

-

(1)Measured in the laboratory on a 170 mm (6 3/4’’) timber-framed wall. See the manual for more information on configuration.

SOUND REDUCTION INDEX LEVEL MEASUREMENTS Tests carried out in the laboratory of the University of Padua in accordance with EN ISO 10140-2 have made it possible to measure the sound reduction index of the construction assembly described below: 1

plasterboard panel (s: 12,5 mm - 0.5 in)

2

SILENT WALL BYTUM SA (s: 4 mm - 0.16 in)

3

plasterboard panel (s: 12,5 mm - 0.5 in)

4

solid wood batten (s: 60 mm - 2.4 in)

5

low density mineral wool insulation (s: 60 mm - 2.4 in)

6

CLT panel (s: 100 mm - 3.9 in)

7

low density mineral wool insulation (s: 60 mm - 2.4 in)

8

solid wood batten (s: 60 mm - 2.4 in)

9

plasterboard panel (s: 12,5 mm - 0.5 in)

1

2

3

4

5

6

8

7 10

9 11

10 SILENT WALL BYTUM SA (s: 4 mm - 0.16 in) 11

plasterboard panel (s: 12,5 mm - 0.5 in)

graphs and frequency values available See the manual for more information on configuration

Rw (C;Ctr) = 59 (-2;-7) dB

Use the QR-code to download the complete manual! www.rothoblaas.com AIRBORNE NOISE | SILENT WALL BYTUM SA | 61


SILENT WALL BYTUM SOUNDPROOFING AND WATERPROOFING BITUMINOUS MEMBRANE

TESTED Thanks to its high surface mass (6 kg/m2), excellent reduction of airborne noise transmission can be achieved with minimal thicknesses. Also tested at the University of Bolzano.

PRACTICAL Mechanical fastening allows the membrane to be applied to any surface, compensating for irregularities.

COST-PERFORMANCE Composition of the mixture optimised to provide both good performance and low cost.

COMPOSITION non-woven polypropylene fabric waterproofing membrane made of elastoplastomeric bitumen non-woven polypropylene fabric

CODES AND DIMENSIONS CODE

SILWALL

H

L

thickness

surface mass

A

H

L

thickness

surface mass

A

[m]

[m]

[mm]

[kg/m2]

[m2]

[ft]

[ft]

[in]

[lb/sft]

[ft2]

1,2

5

4,2

6

6

3’ 3 3/8’’

16’ 4 7/8’’

0.17

1.23

65

30

VERSATILE For any application where an increase in mass is required.

SAFE Made of elastoplastomeric bitumen, covered on both sides with a polypropylene non-woven fabric. Does not contain harmful substances.

62 | SILENT WALL BYTUM | AIRBORNE NOISE


TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

4,2 mm

0.17 in

Surface mass m

-

6 kg/m2

1.23 lb/ft2

Density ρ

-

1500 kg/m3

93.64 lb/ft3

Resistance to airflow r

ISO 9053

> 100 kPa·s·m-2

-

Compressibility class

EN 12431

class CP2

-

CREEP viscous sliding under compression (1.6 kPa - 33.4 psf)

EN 1606

0,5 %

-

Increase of sound reduction index ΔRw(1)

ISO 10140-2

4 dB

-

Vibration damping - loss factor η (200 Hz)

ASTM E756

0,25

-

Thermal resistance Rt

-

0,1 m2K/W

-

Thermal conductivity λ

-

0,7 W/m·K

0.404 BTU/(h·ft2 ·°F)

Specific heat c

-

900 J/kg·K

0.22 BTU/(lb·°F)

Water vapour resistance factor μ

EN 12086

20000

420 MN·s/g

Water vapour transmission Sd

-

80 m

0.043 US perm

Reaction to fire

EN 13501-1

class E

-

(1)Measured in the laboratory on a 170 mm (6 3/4’’) timber-framed wall. See the manual for more information on configuration.

SOUND REDUCTION INDEX LEVEL MEASUREMENTS Tests carried out in the Building Envelope Lab of the Free University of Bozen/Bolzano in accordance with EN ISO 10140-2 have made it possible measured the impact noise level of the construction assembly described below: BASIC CONFIGURATION: timber frame structure (s: 170 mm - 6.7 in)

2

plasterboard panel (s: 12,5 mm - 0.5 in)

stot = 19,5 cm

1

2

Rw = 48 dB STCASTM = 48

1

2

+2,5 cm

1

timber frame structure (s: 170 mm - 6.7 in)

2

2x plasterboard panel (s: 12,5 mm - 0.5 in)

Rw = 52 dB STCASTM = 53

ΔRw= +4 dB

2

stot = 22 cm

CONFIGURATION 1:

1

2

CONFIGURATION 2: timber frame structure (s: 170 mm - 0.5 in) SILENT WALL BYTUM (s: 4,2 mm - 0.17 in)

3

plasterboard panel (s: 12,5 mm - 0.5 in)

Rw = 53 dB STCASTM = 50

ΔRw= +5 dB

stot = 20,3 cm

1 2

+0,8 cm

2

3

1

3

By using SILENT WALL BYTUM you can save space and achieve better results.

graphs and frequency values available See the manual for more information on configuration

Use the QR-code to download the complete manual! www.rothoblaas.com AIRBORNE NOISE | SILENT WALL BYTUM | 63


SILENT WALL | Recommendations for installation SILENT WALL BYTUM SA

1

2

3

4

SILENT WALL BYTUM

1

2

3

4

64 | SILENT WALL | Recommendations for installation | AIRBORNE NOISE


SILENT GIPS THERMAL-ACOUSTIC DECOUPLING TAPE FOR PLASTERBOARD STRUCTURES

DECOUPLING It allows complete acoustic decoupling of the plasterboard wall, preventing the transmission of vibrations to structural elements. Also tested at the University of Bolzano.

DOUBLE-SIDED ADHESIVE Installation with the metal frame is fast and easy, without the need for additional adhesives.

CODES AND DIMENSIONS CODE

SILENTGIPS

B

liner

L

s

B

liner

L

s

[mm]

[mm]

[m]

[mm]

[in]

[in]

[ft]

[in]

100

12-76-12

30

3,3

3 7/8’’

1/2’’-3’’-1/2’’

98’ 5 1/8’’

0.13

1

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

3,3 mm

0.13 in

Density ρ

-

150 kg/m3

9.36 lb/ft³

Dynamic stiffness s’

EN 29052

60 MN/m3

-

Crushing (load 6,5 kPa - 135 psf)

ISO 7214

0,3 mm

0.01 in

Thermal conductivity λ

EN 12667

0,04 W/m·K

0.023 BTU/(h·ft2 ·°F)

Thermal resistance Rt

ISO 6946

0,08 m2K/W

-

Resistance to temperature

-

-20 / +80 °C

-4 / +176 °F

CLOSED CELL Thanks to the grid of closed cell polyethylene, the product will not permanently deform and remains effective over time.

VERSATILE The pre-cut removable film allows the tape to be adapted to different plasterboard wall configurations.

AIRBORNE NOISE | SILENT GIPS | 65


GIPS BAND SINGLE-SIDED NAIL POINT SEALANT TAPE

TESTED It can be used simultaneously as an acoustic decoupling and as self-sealing tape around the nails for the ribs of the counter-wall structure. Also tested in different configurations at the Universities of Bolzano and Padua.

HERMETIC Specifically for rain and airtight sealing of penetration points of nails and screws. Thanks to its closed-cell structure, it is waterproof even when trimmed or perforated.

CODES AND DIMENSIONS CODE

GIPSBAND50

B

s

L

B

s

L

[mm]

[mm]

[m]

[in]

[in]

[ft]

50

3

30

2’’

0.12

98’ 5 1/8’’

10

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

3 mm

0.12 in

Density ρ

-

approx. 25 kg/m3

1.56 lb/ft3

Tear strength MD/CD

ISO 1926

325/220 kPa

-

Elongation MD/CD

ISO 1926

125/115 %

-

Compression strength

ISO 3386/1

10%: 2 kPa 25%: 3 kPa 50%: 5 kPa

-

EN 13501-1

class E

-

DIN 4102-1

class B2

-

Water absorption

ISO 2896

< 2% vol.

-

Thermal conductivity λ

-

0,04 W/(m·K)

0.023 BTU/(h·ft2 ·°F)

Solvents

-

no

-

Storage temperature

-

+5 / +25 °C

+41 / +77 °F

Resistance to temperature

-

-30 / +80 °C

-22 / +176 °F

Reaction to fire

PERFORMANCE Increase of sound insulation

ΔRw = + 4 dB

See the manual for more information on configuration.

66 | GIPS BAND | AIRBORNE NOISE


FLANKSOUND

CONSTRUCTION SEALING

EN ISO 10848

COMPRESSIBLE SEALING GASKET FOR REGULAR JOINTS

NOISE REDUCTION The acoustic performance has been tested in the Flanksound Project by Rothoblaas: using it as a wall isolation gasket provides up to 3 dB of noise reduction.

PRACTICAL Sealing of timber to timber joints can be carried out on site or during prefabrication.

CODES AND DIMENSIONS CODE

CONSTRU4625

B

s

L

B

s

L

[mm]

[mm]

[m]

[in]

[in]

[ft]

46

3

25

1 3/4''

0.12

82’ 1/4

3

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

3 mm

0.12 in

Density ρ

-

approx. 0,48 g/cm3

29.97 lb/ft3

Compression deformation 22h +23 °C (73°F)

EN ISO 815

< 25%

-

Compression deformation 22h +40 °C (104°F)

EN ISO 815

< 35%

-

Correction of Kij in the presence of elastic profile in the joint Δl,ij(1)

ISO 10848-1

4 dB

-

Solvents

-

no

-

Storage temperature

-

+5 / +25 °C

+41 / +77 °F

Resistance to temperature

-

-35 / +100 °C

-31 / +212 °F

(1)Measurement performed during the Flanksound Project. See the manual for more information on configuration.

PERFORMANCE Increase of sound insulation

Δl,ij = 4 dB Δl,ij = Kij,with - Kij,without

See the manual for more i nformation on configuration.

AIRBORNE NOISE | CONSTRUCTION SEALING | 67


SOUND ABSORPTION

WHAT IS REVERBERATION? Reverberation is a phenomenon that occurs inside a closed room when sound waves, generated by a source, are reflected in a disordered manner and for a long period by the walls, even when the sound source has stopped producing them.

HOW DO I SOLVE IT Designing spaces correctly by means of sound absorption means being able to minimise sound wave reflections within rooms, using specific solutions or products capable of absorbing a large amount of them.

very reverberant environment

acoustically corrected environment

microphone

microphone

sound source

sound source

In this image, we note that sound bounces off surfaces and therefore reverberation will be easily perceived.

SOUND ABSORPTION Sound-absorbing materials are those that can dissipate the energy of incident sound waves on the surface, due to their porous nature. Sound-absorbing materials of a fibrous nature, such as SILENT WALL SURFACE, are able to prevent the reflection of sound waves in favour of an effective absorption of the waves, thanks to the convective motions generated in the cavities between the fibres.

68 | SOUND ABSORPTION | AIRBORNE NOISE

soundproofing material

In this image, however, we see that, thanks to a sound-absorbing intervention, the sound impacting the wall decreases drastically.

sound source

soundproofing material

REFLECTION

15%

ABSORPTION

85%


WE WILL TELL YOU ABOUT OUR SILENCE

Acoustic well-being within a building comes from careful design and the choice of efficient materials. Sound-absorbing products reduce background noise in living spaces and have thermal-acoustic functions. When coupled with interior ceiling or wall coverings, they significantly reduce reverberation noise. SILENT WALL SURFACE by Rothoblaas is the sound-absorbing solution with a fibrous polyester felt structure that can speak silently.

Scan the QR code or visit our website to see what's new! www.rothoblaas.com


TRASPIR METAL

EN 13859-1

3D MATS FOR METAL ROOFS

A

CH

Önorm B4119 UD Typ I

SIA 232 UD (g)

AUS

USA

AS/NZS 4200.1 Class 4

D

F

ZVDH USB-A UDB-A

DTU 31.2 E1 Sd1 TR2 E600 Jf C1

I

UNI 11470 A/R2

IRC vp

CERTIFIED NOISE REDUCTION The 3D mats guarantee reduction of airborne and heavy rain noises. Values tested and certified.

PROTECTIVE FELT The breathable membrane with 3D grid includes a fifth layer that blocks impurities and improves ventilation.

HIGH DENSITY 3D GRID The 3D mat has high mechanical strength and is also appropriate for aluminium sheet metal.

2

1

CODES AND DIMENSIONS CODE

1

TTTMET610

2 NET350

description

tape

H

L

A

H

L

A

[m]

[m]

[m2]

[ft]

[ft]

[ft2]

TRASPIR 3D COAT TT

TT

1,35

33

44,55

4.43

108.27

479.54

4

NET 350

-

1,25

50

62,5

4.11

164

672.75

4

SAFE VENTILATION The breathable membrane TRASPIR 3D COAT comes with a 3D grid and a protective felt on the surface, that prevents the entry of impurities and improves ventilation.

VERSATILE Also ideal in combination with BYTUM or TRASPIR to create a micro-ventilation layer in both wall and roof installations.

70 | TRASPIR METAL | AIRBORNE NOISE


LABORATORY MEASUREMENTS The effectiveness of TRASPIR METAL was demonstrated through an airborne soundproofing test and noise generated by heavy rain. The chosen construction assembly was tested with and without TRASPIR METAL (sheet metal directly on the board).

emitting room

reduction of noise from heavy rain up to 4 dB

receiving room

RESULTS

AIRBORNE NOISE

HEAVY RAIN

WITHOUT TRASPIR METAL Increase of sound insulation by 1 dB

Rw = 43 dB

LIA = 36,9 dB

WITH TRASPIR METAL

Rw = 44 dB

Reduction of noise from rain up to 4.2 dB

LIA = 32,7 dB

RECOMMENDATIONS FOR INSTALLATION TRASPIR 3D COAT

1

2

3D NET

1

2 AIRBORNE NOISE | TRASPIR METAL | 71


TRASPIR 3D COAT TT

COMPOSITION protection layer non-woven PP fabric middle layer 3-dimensional PP mat protection layer non-woven PP fabric middle layer PP breathable film bottom layer non-woven PP fabric

TECHNICAL DATA Properties

standard

value

USC conversion

Mass per unit area

EN 1849-2

600 g/m2

1.97 oz/ft2

Thickness

EN 1849-2

8 mm

0.315 in

Water vapour transmission (Sd)

EN 1931

0,025 m

139.86 US perm

Tensile strength MD/CD

EN 12311-1

300 / 220 N/50mm

34 / 25 lb/in

Elongation MD/CD

EN 12311-1

> 35 / 50 %

-

Resistance to nail tearing MD/CD

EN 12310-1

150 / 175 N

33.7 / 39.3 lbf

Watertightness

EN 1928

class W1

-

Temperature resistance

-

-40 / 80 °C

-40 / 176 °F -

Reaction to fire

EN 13501-1

class E

Resistance to penetration of air

EN 12114

< 0,02 m3/(m2h50Pa) < 0.001 cfm/ft2 at 50Pa

Thermal conductivity (λ)

-

0,3 W/(m∙K)

0.17 BTU/h∙ft∙°F

Specific heat

-

1800 J/(kg∙K)

-

Density

-

approx. 75 kg/m3

approx. 0.04 oz/in3

Water vapour resistance factor (μ)

-

approx. 33

approx. 0.1 MNs/g

VOC content

-

< 0,02 %

-

UV stability(1)

EN 13859-1/2

3 months

-

Exposure to weather(1)

-

2 weeks

-

Water column

ISO 811

> 250 cm

> 98.4252 in

- watertightness

EN 1297 / EN 1928

class W1

-

- maximum tensile force MD/CD

EN 1297 / EN 12311-1

> 240 / 155 N/50mm

27 / 22 lb/in

After ageing:

EN 1297 / EN 12311-1

> 30 / 40%

-

Flexibility at low temperatures

- elongation

EN 1109

-40 °C

-22 °F

Void ratio

-

95 %

-

Variation of the sound reduction index ΔRw

ISO 10140-2 / ISO 717-1

1 dB

-

Variation in overall A-weighted sound intensity level from heavy rain noiseΔLiA

ISO 140-18

approx. 4 dB

-

(1) For the correlation between laboratory tests and actual conditions, see the catalogue "TAPES, SEALANTS AND MEMBRANES" at www.rothoblaas.com.

72 | TRASPIR METAL | AIRBORNE NOISE


3D NET

COMPOSITION 3D grid 3-dimensional PP mat

TECHNICAL DATA Properties

standard

value

USC conversion

Mass per unit area

EN 1849-2

350 g/m2

1.15 oz/ft2

Thickness

EN 1849-2

7.5 mm

0.295 in

Maximum tensile force MD/CD NET

EN 12311-1

1,3 / 0,5 N/50mm

0.15 / 0.06 lb/in

Elongation MD/CD NET

EN 12311-1

95 / 65 %

-

Temperature resistance

-

-40 / 80 °C

-40 / 176 °F

Reaction to fire

EN 13501-1

class F

-

Density

-

approx. 35 kg/m3

approx. 0.02 oz/in3

VOC emissions

-

< 0,02 %

-

UV stability(1)

EN 13859-1/2

3 months

-

Exposure to weather(1)

-

4 weeks

-

Void ratio

-

95 %

-

Variation of the sound reduction index ΔRw

ISO 10140-2 / ISO 717-1

1 dB

-

Variation in overall A-weighted sound intensity level from heavy rain noiseΔLiA

ISO 140-18

4 dB

-

Impact sound attenuation index ΔLw

ISO 140-8

28 dB

-

(1) For the correlation between laboratory tests and actual conditions, see the catalogue "TAPES, SEALANTS AND MEMBRANES" at www.rothoblaas.com.

DURABILITY When installed on a continuous support, it promotes micro-ventilation of metal roofs, preventing corrosion.

AIRBORNE NOISE | TRASPIR METAL | 73


ACOUSTIC UPGRADING AND RETROFIT The objective of a redevelopment is to improve the performance of the building and achieve a better level of comfort. Successful acoustic upgrading requires the services of a competent technician, who generally follows the project procedure indicated below:

Measurement of sound levels in situ. This step is fundamental in order to be able to identify the building's critical issues and weak points.

Acoustic design. In consideration of the results obtained in the first phase, the designer identifies the necessary retrofits to improve acoustic performance.

Implementation of the interventions foreseen in the project. Installation and attention to detail is critical.

Measurement of sound levels after the retrofit to verify its effectiveness.

Some examples of solutions designed by Rothoblaas to improve the acoustic performance of certain building elements are shown below. The recommended retrofits should not be considered exhaustive of all cases and may not be sufficient to achieve performance goals. The indicated acoustic improvement refers to the tested configuration, which is why Rothoblaas recommends that solutions should always be checked with the acoustic designer.

AIR-TIGHTNESS AND CRITICAL POINTS Air is an element of noise passage and heat loss. Even the smallest crack allows noise propagation and influences the final performance of the building element. Restoring the airtightness of the building with the solutions proposed in the chapter "ACOUSTIC and SEALING" is essential to ensure an effective acoustic solution.

Sealing a through gap can produce an improvement of up to + 24 dB. 74 | ACOUSTIC UPGRADING AND RETROFIT


WALL ASSEMBLIES THIN ACOUSTIC UPGRADES Bonded coating is a commonly used method for acoustic upgrades because it allows, in just a few centimetres of thickness, a significant improvement in the sound rating of the partition.

Add mass by coupling SILENT WALL BYTUM or SILENT WALL BYTUM SA to the plasterboard sheet ΔRw= + 7 dB

ΔRw= + 8 dB

ΔRw= + 8 dB ΔSTCASTM = + 6

ΔRw= + 10 dB ΔSTCASTM = + 10

ΔRw= + 8 dB ΔSTCASTM = + 9

ΔRw= + 13 dB ΔSTCASTM = + 13

Add a resilient layer SILENT FLOOR PUR or SILENT FLOOR TEX between the base structure and the plasterboard sheet

Add strips of resilient layer PIANO A, SILENT FLOOR PUR in strips and SILENT FLOOR TEX in strips and mass by coupling SILENT WALL BYTUM or SILENT WALL BYTUM SA to the plasterboard sheet

RENOVATION WITH SUPPORTING WALLS The addition of a supporting wall allows higher performance to be achieved, but requires greater thickness.

Separate the uprights of the supporting wall from the structure with PIANO A, SILENT UNDERFLOOR, GEMINI, GIPS BAND, CONSTRUCTION SEALING and add mass to the plasterboard sheet with SILENT WALL BYTUM or SILENT WALL BYTUM SA

ΔRw= + 11 dB ΔSTCASTM = + 10

ΔRw= + 16 dB ΔSTCASTM = + 14

ΔRw= + 18 dB ΔSTCASTM = + 13

ΔRw= + 29 dB ΔSTCASTM = + 24

Create a self-supporting structure separated from the structure by at least 1 cm and add mass with SILENT WALL BYTUM or SILENT WALL BYTUM SA to the plasterboard sheet

Construction assemblies measured in the laboratory. Frequency data available.

DID YOU KNOW THAT... The soundproofing of a partition is strongly influenced by the performance of the weakest elements. In façades, it is often the windows and doors that determine the acoustic performance and the renovation work must include replacement of the window and door frames and installation according to the three-stage method (see "Window Acoustics" page 136).

ACOUSTIC UPGRADING AND RETROFIT | 75


FLOORS ASSEMBLIES ACOUSTIC UPGRADES FROM ABOVE

Cover the underside of the floor by applying a resilient layer PIANO A, SILENT UNDERFLOOR, GEMINI, GIPS BAND, CONSTRUCTION SEALING to the joists and by adding mass to the plasterboard sheet with SILENT WALL BYTUM or SILENT WALL BYTUM SA

SILENT WALL BYTUM SA ΔRw= + 15 dB ΔSTCASTM = + 8

ΔLn,w= - 17 dB ΔIICASTM = + 17

The addition of the resilient layer PIANO A or SILENT FLOOR EVO in strips produces a further improvement (approx. 4dB)

Values obtained through calculations from experimental data.

POSSIBILITY OF INTERVENTION ONLY FROM ABOVE

Add a resilient layer with SILENT FLOOR PUR, SILENT FLOOR TEX, SILENT FLOOR BYTUM, SILENT FLOOR PE and a an acoustic topping or double solid layer (44 + 34,6 kg/m2)

SILENT FLOOR PUR ΔRw= + 12 dB ΔSTCASTM = + 10

ΔLn,w= - 22 dB ΔIICASTM = + 22

SILENT FLOOR PUR ΔLn,w= - 21 dB ΔIICASTM = + 21

Make a raised floor system with battens and resilient layer PIANO A, SILENT FLOOR PUR in strips, SILENT TEX in strips, SILENT UNDERFLOOR, NAIL PLASTER, GEMINI, GIPS BAND, CONSTRUCTION SEALING and a double solid layer (44 + 34.6 kg/m2)

PIANO A

PIANO A

ΔRw= + 12 dB ΔSTCASTM = + 13 Values obtained from laboratory tests on CLT floor.

FULL RETROFIT

Acoustic upgrades from both sides of a floor or wall assembly achieves higher performance, but requires greater thickness and the access for installation

DID YOU KNOW THAT... When building a new floor assembly, it is a good idea to provide a resilient SILENT STEP or SILENT STEP ALU layer underneath the floating floor for maximum acoustic performance.

76 | ACOUSTIC UPGRADING AND RETROFIT

ΔLn,w= - 31 dB ΔIICASTM = + 31


INSTALLATIONS Solutions vary depending on the type of construction and acoustic requirements.

Create a mechanical, electrical, plumbing (MEP) enclosure and use SILENT WALL BYTUM or SILENT WALL BYTUM SA to improve its sound reduction index

Seal any gaps created by the MEP penetrations with HERMETIC FOAM or FIRE SEALING SILICONE

Place a resilient layer PIANO A, SILENT FLOOR PUR in strips, SILENT FLOOR TEX in strips, SILENT UNDERFLOOR, GIPS BAND, CONSTRUCTION SEALING between the MEP components and the fixing system to avoid rigid contact with other elements.

ACOUSTIC UPGRADING AND RETROFIT | 77


ACOUSTIC DESIGN OF BUILDINGS For the project to be successful and achieve high levels of comfort, it is necessary to adopt a multi-disciplinary approach and to involve the acoustic designer at an early stage in order to make design choices that take into account solutions aimed at noise reduction. Good acoustic design in fact starts with the correct design of the structure, where action can be taken to minimise flanking sound transmission. Rothoblaas recommends a competent technician who will take the various aspects of acoustic design into account:

DIRECT SOUND TRANSMISSION AND CHOICE OF MATERIALS If project requirements allow it, it is preferable to choose a construction assembly that has already been tested in the laboratory. It must be taken into account that, in general, elastic materials, added mass and raised floors help to improve performance.

REDUCTION OF FLANKING SOUND TRANSMISSION Structural elements must be separated with appropriately calculated resilient profiles to prevent the propagation of vibrations and thus noise through the structure.

ATTENTION TO DETAILS Ensure airtight construction to limit airborne sound transmission through cracks. Air is one of the main mediums through which sound waves travel.

REDUCTION OF FLANKING SOUND TRANSMISSION In buildings, sound transmission between rooms is characterised not only by direct transmission but also by sound propagation through the structure. The effect of sound spreading through the connections and intersections in the structure is called flanking sound transmission and can drastically reduce the acoustic performance of walls and floors. To minimise this phenomenon, it is necessary to decouple the structural elements. XYLOFON, PIANO and ALADIN placed between rigid elements prevent the propagation of vibrations in the structure and reduce sound transmission in the between adjacent areas in the structure. The contribution of resilient profiles can be assessed in terms of Kij

The reduction in lateral transmission can also be assessed in terms of Rij,situ and Ln,ij,situ

with XYLOFON: Δl,ij > 6 dB

with XYLOFON:

Kij measured for different configurations and with different hardnesses of XYLOFON

78 | ACOUSTIC DESIGN OF BUILDINGS

ΔRij,situ = 10 dB ΔLn,ij,situ = 8 dB


DIRECT SOUND TRANSMISSION AND CHOICE OF MATERIALS Rothoblaas provides a database full of solutions measured in the laboratory and on site that are useful for defining the project construction assembly. Here are some examples: see the manual to learn about all the solutions tested by Rothoblaas.

FLOOR SLAB CLT with double screed with false ceiling

Rw= from 59 dB to 62 dB STCASTM = from 57 to 64

Various solutions were tested in the laboratory and on site with XYLOFON and ALADIN and various products from the SILENT FLOOR and SILENT STEP ranges

Rw= from 50 dB to 34 dB IICASTM = from 62 to 75

Rw= from 53 dB to 57 dB STCASTM = from 53 to 57

CLT with double screed without false ceiling Various solutions were tested in the laboratory and on site with XYLOFON and different products from the SILENT FLOOR range

Ln,w= from 60 dB to 48 dB IICASTM = from 50 to 62

CLT and raised floor Different types of raised floor were tested in the laboratory and on site with XYLOFON using PIANO A and GRANULO

Ln,w= from 57 dB to 47 dB IICASTM = from 43 to 50

CLT with single screed without false ceiling Different configurations were tested in the laboratory and on site with XYLOFON using products from the SILENT FLOOR range in single and double layers

Ln,w= from 67 dB to 61 dB IICASTM = from 53 to 63

WALL CLT Rw= from 46 dB to 59 dB STCASTM = from 46 to 59

Different wall types with one or two supporting walls and the use of SILENT WALL and SILENT UNDERFLOOR were tested in the laboratory IN

CLT façade

Rw= 58 dB STCASTM = 56

The façade was tested in the laboratory with GIPS BAND OUT

Frame without supporting wall Various wall types were tested in the laboratory using products from the SILENT WALL and SILENT FLOOR PUR range

Rw= from 48 dB to 55 dB STCASTM = from 49 to 55

Frame with supporting wall Various wall types were tested in the laboratory using products from the SILENT WALL, GIPS BAND and SILENT FLOOR PUR ranges

Rw= from 50 dB to 70 dB STCASTM = from 49 to 65

ACOUSTIC DESIGN OF BUILDINGS | 79



STRUCTURAL NOISE


acoustic load [N/mm2] 0

XYLOFON 20

0,016

XYLOFON 35

0,038

XYLOFON 50

0,22

XYLOFON 70

1

2

0,68

0,49

1,5

1,3

2,4

STRUCTURAL NOISE

2,2

PIANO A

0,008

PIANO B

0,04

5

0,32

XYLOFON 90

4,5

0,052

0,286

0,26

1,4

PIANO D

1,2

PIANO E

2,28

1,8

ALADIN EXTRA SOFT

0,035

0,157

ALADIN SOFT

0,189

0,316

CORK SOFT

0,2

CORK HARD

4

0,14

XYLOFON 80

PIANO C

3

3,2

0,75

0,75

3


1

STRUCTURAL NOISE XYLOFON HIGH PERFORMANCE RESILIENT SOUNDPROOFING PROFILE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

XYLOFON WASHER SEPARATING WASHER FOR TIMBER SCREW AND WHT. . . . . . . 102

XYLOFON PLATE SEPARATING PROFILE FOR TIMBER SHEAR BRACKET ANGLES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

PIANO RESILIENT SOUNDPROOFING PROFILE . . . . . . . . . . . . . . . . . . . . 106

CORK ECOLOGICAL PANEL FOR ACOUSTIC INSULATION. . . . . . . . . . . 116

ALADIN RESILIENT SOUNDPROOFING PROFILE . . . . . . . . . . . . . . . . . . . . . 118

TRACK RESILIENT SOUNDPROOFING PROFILE . . . . . . . . . . . . . . . . . . . . 122

GRANULO STRIPE RESILIENT GRANULAR RUBBER SOUNDPROOFING PROFILE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

TIE-BEAM STRIPE TIE BEAM SEALING PROFILE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126

STRUCTURAL NOISE | 83


REDUCTION OF FLANKING SOUND TRANSMISSION In the laboratory or on site, is the result identical? The answer, of course, is no, and in fact measurements of sound reduction index and impact level, with the same construction assembly, produce very different results.

LABORATORY MEASUREMENTS

ON SITE MEASUREMENTS

Dd

Dd Ff

In a laboratory, the component to be tested is installed in rooms decoupled from each other that are designed specifically for that purpose. Measurements in the laboratory are characterised by direct transmission, i.e. only through the separating construction element.

Fd Df

When the sound reduction index is measured on site, the value is lower than that measured in the laboratory for the same construction assembly. This is because transmission between rooms is also characterised by flanking sound transmission, i.e. the contributions to propagation made by structural or rigid building elements.

The designer must be able to correctly estimate the size and contribution of flanking sound transmission, which can be quite significant, to ensure compliance with the passive acoustic requirements measured on site.

4 SIDES BETWEEN WHICH FLANKING SOUND TRANSMISSION TAKES PLACE side A

3 TRANSMISSION PATHS

side B

Fd

Df

Ff

4 sides x 3 paths =

12 transmission paths side C

side D

84 | REDUCTION OF FLANKING SOUND TRANSMISSION | STRUCTURAL NOISE


Timber structures, like all lightweight types of construction, do not have high acoustic performance due to transmission of vibration through the elements that make up the structure: for this reason, timber structures must be designed with a different mentality than traditional structures. Vibration propagation must also be stopped at the structural level in order to have a reduction in noise transmission.

Fd

WHAT DOES DECOUPLING CONSIST OF?

Df

Decoupling is the action or construction technique in which elements are kept separate or isolated, as contact between them would allow the transmission of vibrations and thus noise.

Fd

Df

Fd

Df

Df RESILIENT PRODUCTS Fd These are elastic separating layers between rigid elements whose main purpose is to prevent the transmission of vibrations in the building structure, for example impacts or noise from footsteps, to its structural elements. Working at this level of the structure means being able to solve the problem at the source, allowing greater flexibility during design and modification of the other layers and materials within the assembly, such as thermal and acoustic insulation or coverings and various architectural finishes. ESTIMATION OF FLANKING SOUND TRANSMISSION (ISO 12354) Lateral transmission can be estimated as: Rij,w=

Ri,w +Rj,w 2

+ ΔRij,w + Kij + 10log

Dd Ff

S (dB) I0 Iij

Fd Df

The parameter that takes into account structural decoupling and represents the energy dissipated by the joint is the VIBRATION REDUCTION INDEX Kij.

ASTM & Kij

The ASTM standards currently do not provide a predictive model for the evaluation of lateral transmission, so the ISO 12354 and ISO 10848 standards are used and "translated" into the ASTM metric. STCij =

STCi 2

+

STCj 2

+ Kij + max(ΔSTCi ,ΔSTCi )+

min(ΔSTCi ,ΔSTCi ) 2

+ 10log

SS I0Iij

STRUCTURAL NOISE | REDUCTION OF FLANKING SOUND TRANSMISSION | 85


CORRECT DESIGN OF RESILIENT PROFILES

CORRECT DESIGN OF STRUCTURAL JOINTS

If resilient profiles are not included in the design, the propagation of vibrations at the structural level is not interrupted and the contribution of flanking sound transmission can be significant, both for airborne sound and the impact sound.

The profile, placed only above the floor, interrupts part of the propagation of vibrations generated by airborne noise. The absence of the lower profile causes part of the airborne noise and all impact noise to propagate indirectly.

The profile placed only below the ceiling interrupts the propagation of vibrations generated by impact noise. As we can see, this configuration lacks the profile that interrupts the propagation of vibrations generated by airborne noise.

Due to the presence of the resilient profile both above and below the floor, all lateral transmission paths were interrupted and the propagation of vibrations through the structure was minimised.

DESIGNING THE CORRECT PROFILE ACCORDING TO THE LOAD Resilient profiles must be correctly loaded in order to isolate the low to medium frequencies of structurally transmitted vibrations: guidance on how to proceed with the evaluation of the product are given below. It is advisable to add the permanent load value at 50% of the characteristic value of the accidental load.

Qlinear = qgk + 0,5 qvk Q

linear

= DL + 0,5 LL

It is necessary to focus on the operating conditions and not the ultimate limit state conditions. This is because the goal is to insulate the building from noise during normal operating conditions and not during design level events.

86 | CORRECT DESIGN OF RESILIENT PROFILES | STRUCTURAL NOISE


PRODUCT SELECTION To properly evaluate the product using MyProject, simply follow the step-by-step instructions provided by the software.

1 The product can also be selected using the application tables (see below for the XYLOFON 35 table), which help to choose the correct product.

2 Note: The static behaviour of the material in compression is evaluated, considering that the deformations due to the loads are static. This is because a building does not present significant movement phenomena, nor dynamic deformation. Rothoblaas has chosen to define a load range that allows good acoustic performance and avoids excessive deformation and differential movements in the materials, including the building's final architectural finishes. However, it is possible to use profiles with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed.

DETERMINATION OF PERFORMANCE Once the loads have been identified, it is necessary to figure out what the design frequency is, namely the exciting frequency of the element of which the structure and transmissibility of the product has to be insulated, depending on the design frequency under the chosen load conditions. The MyProject software automatically calculates natural frequency, transmissibility and attenuation, and by downloading the full manual from www.rothoblaas.com, it is possible to see all the graphs relating to product performance. NOTE:The transmissibility graphs do not consider the influence of the fastening systems that may affect the final performance of the resilient profile: the greater the thickness of the acoustic profile, the lower the stiffness of the building. Consequently, it is necessary to increase the number of connectors to compensate for the loss of rigidity/strength. This leads to an increase in vibration "transmission points", which reduces the benefit of resilient profiles.

For this reason, it is advised to choose a laboratory-tested product, whose Kij values measured with appropriate fastening systems and whose measuring conditions are declared.

Rothoblaas has invested in the development of solutions that follow a multidisciplinary approach and take into account the real conditions of the construction site. Laboratory measurements, static tests, durability tests, moisture control and fire performance studies allow the designer to benefit from real performance data and not just theoretical values that have limited practical applications.

F

STRUCTURAL NOISE | CORRECT DESIGN OF RESILIENT PROFILES | 87


XYLOFON

HIGH PERFORMANCE RESILIENT SOUNDPROOFING PROFILE

CERTIFIED, TESTED, DURABLE XYLOFON is the resilient profile that provides acoustic comfort in timber structures and residential houses, but is also suitable for other building systems. Made of a polyurethane compound, it is available in 6 versions from 20 to 90 Shore, on the basis of the load it has to support. The product is tested and certified for use as a decoupling and mechanical isolation layer between building materials. Due to its elasticity and damping capacity, the product has been tested according to international standards ISO 10848 and ISO 16283 and significantly reduces airborne and structure-borne noise transmission (from 5 to over 15 dB). The low thickness of the six versions can support a wide range of loads without affecting the design choices. Also suitable for LVL, steel and concrete.

88 | XYLOFON | STRUCTURAL NOISE

FLANKSOUND LCA

LCA

EPD

EPD

EN ISO 10848

ETA-23/0061


MONOLITHIC AND WATERPROOF The monolithic structure of polyurethane guarantees impermeability, stability, long-term elastic properties and no structural failure in the long-term. XYLOFON is free of VOCs or harmful substances and is extremely chemically stable.

SMART The profiles are easily processed and installed with the most common construction tools. Moreover, the wide range makes it ideal for every size and load of building element.

FIRE Tested performance for characterisation and fire behaviour, both in exposed structural joints and for use in multi-storey buildings.

INTEGRATED DESIGN Rothoblaas has studied and tested the product over the years in the most relevant project areas: acoustics, structural capacity, moisture and fire. This allows a single solution for different needs.

CODES AND DIMENSIONS CODE

Shore

B

L

s

B

L

s

pcs

[mm]

[m]

[mm]

[in]

[ft]

[in]

XYL20050

50

3,66

6,0

2

12

1/4

1

XYL20080

80

3,66

6,0

3 1/8

12

1/4

1

XYL20090

90

3,66

6,0

3 1/2

12

1/4

1

XYL20100

100

3,66

6,0

4

12

1/4

1

XYL20120

120

3,66

6,0

4 3/4

12

1/4

1

XYL20140

140

3,66

6,0

5 1/2

12

1/4

1

XYL20160

160

3,66

6,0

6 1/4

12

1/4

1

XYL35080

80

3,66

6,0

3 1/8

12

1/4

1

XYL35090

90

3,66

6,0

3 1/2

12

1/4

1

XYL35100

100

3,66

6,0

4

12

1/4

1

120

3,66

6,0

4 3/4

12

1/4

1

XYL35140

140

3,66

6,0

5 1/2

12

1/4

1

XYL35160

160

3,66

6,0

6 1/4

12

1/4

1

XYL50080

80

3,66

6,0

3 1/8

12

1/4

1

XYL50090

90

3,66

6,0

3 1/2

12

1/4

1

XYL50100

100

3,66

6,0

4

12

1/4

1

120

3,66

6,0

4 3/4

12

1/4

1

XYL50140

140

3,66

6,0

5 1/2

12

1/4

1

XYL50160

160

3,66

6,0

6 1/4

12

1/4

1

XYL35120

XYL50120

20

35

50

XYL70080

80

3,66

6,0

3 1/8

12

1/4

1

XYL70090

90

3,66

6,0

3 1/2

12

1/4

1

XYL70100

100

3,66

6,0

4

12

1/4

1

120

3,66

6,0

4 3/4

12

1/4

1

XYL70140

140

3,66

6,0

5 1/2

12

1/4

1

XYL70160

160

3,66

6,0

6 1/4

12

1/4

1

XYL80080

80

3,66

6,0

3 1/8

12

1/4

1

XYL80090

90

3,66

6,0

3 1/2

12

1/4

1

XYL80100

100

3,66

6,0

4

12

1/4

1

XYL70120

XYL80120

70

80

120

3,66

6,0

4 3/4

12

1/4

1

XYL80140

140

3,66

6,0

5 1/2

12

1/4

1

XYL80160

160

3,66

6,0

6 1/4

12

1/4

1

XYL90080

80

3,66

6,0

3 1/8

12

1/4

1

XYL90090

90

3,66

6,0

3 1/2

12

1/4

1

XYL90100

100

3,66

6,0

4

12

1/4

1

120

3,66

6,0

4 3/4

12

1/4

1

XYL90140

140

3,66

6,0

5 1/2

12

1/4

1

XYL90160

160

3,66

6,0

6 1/4

12

1/4

1

XYL90120

90

STRUCTURAL NOISE | XYLOFON | 89


PRODUCT COMPARISON thickness

acoustic improvement Δl,ij(1)

compressive modulus Ec

XYLOFON 20

6 mm 1/4 in

> 7 dB

1,45 N/mm2 210 psi

XYLOFON 35

6 mm 1/4 in

7,4 dB

3,22 N/mm2 467 psi

XYLOFON 50

6 mm 1/4 in

10,6 dB

7,11 N/mm2 1031 psi

XYLOFON 70

6 mm 1/4 in

7,8 dB

14,18 N/mm2 2057 psi

XYLOFON 80

6 mm 1/4 in

> 7 dB

25,39 N/mm2 3683 psi

XYLOFON 90

6 mm 1/4 in

> 7 dB

36,56 N/mm2 5303 psi

products

LEGEND: load for acoustic optimisation compressive stress at 3 mm (ultimate limit state)

90 | XYLOFON | STRUCTURAL NOISE


dynamic elastic modulus E’5Hz -E’50Hz

damping factor tanδ5Hz - tanδ50Hz

acoustic load / maximum applicable load 0

5

10

15

20

25

30

35

acoustic load [N/mm 2]

0,016 -

0,14

-

maximum applicable load [N/mm 2]

0,016

1,25

acoustic load [N/mm 2]

0,038 3,10 N/mm2 - 3,60 N/mm2 1305 psi - 1552 psi

0,32

0,321 - 0,382 maximum applicable load [N/mm 2]

0,038

3,61

acoustic load [N/mm 2]

0,22 3,93 N/mm2 - 4,36 N/mm2 1610 psi - 1958 psi

0,68

0,173 - 0,225

maximum applicable load [N/mm 2]

0,22

8,59

acoustic load [N/mm 2]

0,49 6,44 N/mm2 - 7,87 N/mm2 2393 psi - 3104 psi

1,5

0,118 - 0,282 maximum applicable load [N/mm 2]

0,49

11,1

acoustic load [N/mm 2]

1,3 16,90 N/mm2 - 21,81 N/mm2 3568 psi - 4487 psi

2,4

0,150 - 0,185 maximum applicable load [N/mm 2]

1,3

19,51

acoustic load [N/mm 2]

2,2 39,89 N/mm2 - 65,72 N/mm2 6150 psi - 8093 psi

(1) Δ

0,307 - 0,453

4,5

maximum applicable load [N/mm 2]

2,2

28,97

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

STRUCTURAL NOISE | XYLOFON | 91

40


XYLOFON 20 CODES AND DIMENSIONS CODE

Shore

XYL20050 XYL20080 XYL20090 XYL20100 XYL20120 XYL20140 XYL20160

20

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

50 80 90 100 120 140 160

3,66 3,66 3,66 3,66 3,66 3,66 3,66

6,0 6,0 6,0 6,0 6,0 6,0 6,0

2 3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4

12 12 12 12 12 12 12

1/4 1/4 1/4 1/4 1/4 1/4 1/4

pcs 1 1 1 1 1 1 1

NEW PRODUCT

TABLE OF USE(1) CODE XYL20050 XYL20080 XYL20090 XYL20100 XYL20120 XYL20140 XYL20160

load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 0,7 590 8 5163 1,12 944 12,8 8261 1,26 1062 14,4 9293 1,4 1180 16 10326 1,68 1416 19,2 12391 1,96 1652 22,4 14456 2,24 1888 25,6 16521

compression for acoustic optimisation(2) [N/mm2] [psi] min max

0,016 2.32

0,14 20.3

reduction [mm] [mil] min

max

0,06 2

0,6 24

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

1,25 181

(1) The load ranges reported are optimised with respect to the static behaviour of the material assessed under compression, considering the effect of friction and the

system resonance frequency, which falls between 20 and 30 Hz, with a maximum deformation of 12%. See the manual or use MyProject to view transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA: available upon request.

LIGHTNESS AND HEIGHT XYLOFON 20 is the range innovation for light structures and low loads. The acoustic insulation performance is the same as for Mass Timber structures, but the 20 shore polyurethane compound allows for use on light-frame structures, roofs and floors. In the construction of multi-storey buildings, the use of XYLOFON 20 ensures soundproofing of the highest floors.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 7 dB Maximum applicable load (deformation 3 mm):

1,25 N/mm2 Acoustic load:

from 0,016 to 0,14 N/mm2 92 | XYLOFON | STRUCTURAL NOISE


XYLOFON 35 CODES AND DIMENSIONS CODE

Shore

XYL35080 XYL35090 XYL35100 XYL35120 XYL35140 XYL35160

35

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

80 90 100 120 140 160

3,66 3,66 3,66 3,66 3,66 3,66

6,0 6,0 6,0 6,0 6,0 6,0

3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4

12 12 12 12 12 12

1/4 1/4 1/4 1/4 1/4 1/4

pcs 1 1 1 1 1 1

TABLE OF USE(1) CODE XYL35080 XYL35090 XYL35100 XYL35120 XYL35140 XYL35160

load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 3,04 2242 25,6 18882 3,42 2522 28,8 21242 3,8 2803 32 23602 4,56 3363 38,4 28322 5,32 3924 44,8 33043 6,08 4484 51,2 37763

compression for acoustic optimisation(2) [N/mm2] [psi] min max

0,038 5.5

0,32 46.4

reduction [mm] [mil] min

max

0,05 2

0,5 20

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

3,61 524

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3) Compressive modulus Ec Dynamic elastic modulus E’5Hz -E’50Hz Damping factor tanδ5Hz - tanδ50Hz Compression set c.s. Compressive stress at 1 mm (1/32 in)strain σ 1mm Compressive stress at 2 mm (1/16 in) strain σ 2mm Compressive stress at 3 mm (1/8 in) strain σ3mm Dynamic stiffness s’(4) Max processing temperature (TGA) Reaction to fire Water absorption after 48h

ISO 10848 ISO 844 ISO 4664-1 ISO 4664-1 ISO 1856 ISO 844 ISO 844 ISO 844 ISO 9052 EN 13501-1 ISO 62

7,4 dB 3,22 MPa 3,10 MPa - 3,60 MPa 0,321 - 0,382 0,72% 0,5 N/mm2 1,54 N/mm2 3,61 N/mm2 1262 MN/m3 200 °C class E < 1%

467 psi 1305 psi - 1552 psi 73 psi 223 psi 524 psi 392 °F -

(3)Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : 7,4 dB Maximum applicable load (deformation 3 mm):

3,61 N/mm2 Acoustic load:

from 0,038 to 0,32 N/mm2 STRUCTURAL NOISE | XYLOFON | 93


XYLOFON 50 CODES AND DIMENSIONS CODE

Shore

XYL50080 XYL50090 XYL50100 XYL50120 XYL50140 XYL50160

50

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

80 90 100 120 140 160

3,66 3,66 3,66 3,66 3,66 3,66

6,0 6,0 6,0 6,0 6,0 6,0

3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4

12 12 12 12 12 12

1/4 1/4 1/4 1/4 1/4 1/4

pcs 1 1 1 1 1 1

TABLE OF USE(1) CODE XYL50080 XYL50090 XYL50100 XYL50120 XYL50140 XYL50160

load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 17,6 12981 54,4 40123 19,8 14604 61,2 45139 22 16226 68 50154 26,4 19472 81.6 60185 30,8 22717 95,2 70216 35,2 25962 108,8 80247

compression for acoustic optimisation(2) [N/mm2] [psi] min max

0,22 31.9

0,68 98.6

reduction [mm] [mil] min

max

0,07 3

0,6 24

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

8,59 1246

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3) Compressive modulus Ec Dynamic elastic modulus E’5Hz -E’50Hz Damping factor tanδ5Hz - tanδ50Hz Compression set c.s. Compressive stress at 1 mm (1/32 in)strain σ 1mm Compressive stress at 2 mm (1/16 in) strain σ 2mm Compressive stress at 3 mm (1/8 in) strain σ3mm Dynamic stiffness s’(4) Max processing temperature (TGA) Reaction to fire Water absorption after 48h

ISO 10848 ISO 844 ISO 4664-1 ISO 4664-1 ISO 1856 ISO 844 ISO 844 ISO 844 ISO 9052 EN 13501-1 ISO 62

10,6 dB 7,11 MPa 3,93 MPa - 4,36 MPa 0,173 - 0,225 1,25% 1,11 N/mm2 3,5 N/mm2 8,59 N/mm2 1455 MN/m3 200 °C class E < 1%

1031 psi 1610 psi - 1958 psi 161 psi 508 psi 1246 psi 392 °F -

(3)Δ = K l,ij ij,with - Kij,without. See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : 10,6 dB Maximum applicable load (deformation 3 mm):

8,59 N/mm2 Acoustic load:

from 0,22 to 0,68 N/mm2 94 | XYLOFON | STRUCTURAL NOISE


XYLOFON 70 CODES AND DIMENSIONS CODE

Shore

XYL70080 XYL70090 XYL70100 XYL70120 XYL70140 XYL70160

70

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

80 90 100 120 140 160

3,66 3,66 3,66 3,66 3,66 3,66

6,0 6,0 6,0 6,0 6,0 6,0

3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4

12 12 12 12 12 12

1/4 1/4 1/4 1/4 1/4 1/4

pcs 1 1 1 1 1 1

TABLE OF USE(1) CODE XYL70080 XYL70090 XYL70100 XYL70120 XYL70140 XYL70160

load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 39,2 28912 120 88507 44,1 32526 135 99571 49 36141 150 110634 58,8 43369 180 132761 68.6 50597 210 154888 78,4 57825 240 177015

compression for acoustic optimisation(2) [N/mm2] [psi] min max

0,49 71.1

1,5 218

reduction [mm] [mil] min

max

0,2 8

0,65 26

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

11,1 1610

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3) Compressive modulus Ec Dynamic elastic modulus E’5Hz -E’50Hz Damping factor tanδ5Hz - tanδ50Hz Compression set c.s. Compressive stress at 1 mm (1/32 in)strain σ 1mm Compressive stress at 2 mm (1/16 in) strain σ 2mm Compressive stress at 3 mm (1/8 in) strain σ3mm Dynamic stiffness s’(4) Max processing temperature (TGA) Reaction to fire Water absorption after 48h

ISO 10848 ISO 844 ISO 4664-1 ISO 4664-1 ISO 1856 ISO 844 ISO 844 ISO 844 ISO 9052 EN 13501-1 ISO 62

7,8 dB 14,18 MPa 6,44 MPa - 7,87 MPa 0,118 - 0,282 0,71% 2,44 N/mm2 5,43 N/mm2 11,1 N/mm2 1822 MN/m3 200 °C class E < 1%

2057 psi 2393 psi - 3104 psi 354 psi 788 psi 1610 psi 392 °F -

(3)Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load.

PERFORMANCE Acoustic improvement tested

Δl,ij(3) : 7,8 dB Maximum applicable load (deformation 3 mm):

11,1 N/mm2 Acoustic load:

from 0,49 to 1,5 N/mm2 STRUCTURAL NOISE | XYLOFON | 95


XYLOFON 80 CODES AND DIMENSIONS CODE

Shore

XYL80080 XYL80090 XYL80100 XYL80120 XYL80140 XYL80160

80

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

80 90 100 120 140 160

3,66 3,66 3,66 3,66 3,66 3,66

6,0 6,0 6,0 6,0 6,0 6,0

3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4

12 12 12 12 12 12

1/4 1/4 1/4 1/4 1/4 1/4

pcs 1 1 1 1 1 1

TABLE OF USE(1) CODE XYL80080 XYL80090 XYL80100 XYL80120 XYL80140 XYL80160

load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 104 76706 192 141612 117 86295 216 159313 130 95883 240 177015 156 115060 288 212418 182 134236 336 247821 208 153413 384 283224

compression for acoustic optimisation(2) [N/mm2] [psi] min max

1,3 189

2,4 348

reduction [mm] [mil] min

max

0,3 12

0,57 22

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

19,51 2830

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3) Compressive modulus Ec Dynamic elastic modulus E’5Hz -E’50Hz Damping factor tanδ5Hz - tanδ50Hz Compression set c.s. Compressive stress at 1 mm (1/32 in)strain σ 1mm Compressive stress at 2 mm (1/16 in) strain σ 2mm Compressive stress at 3 mm (1/8 in) strain σ3mm Dynamic stiffness s’(4) Max processing temperature (TGA) Reaction to fire Water absorption after 48h

ISO 10848 ISO 844 ISO 4664-1 ISO 4664-1 ISO 1856 ISO 844 ISO 844 ISO 844 ISO 9052 EN 13501-1 ISO 62

> 7 dB 25,39 MPa 16,90 MPa - 21,81 MPa 0,150 - 0,185 1,31% 3,85 N/mm2 9,52 N/mm2 19,51 N/mm2 2157 MN/m3 200 °C class E < 1%

3683 psi 3568 psi - 4482 psi 558 psi 1381 psi 2830 psi 392 °F -

(3)Δ = K l,ij ij,with - Kij,without. See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 7 dB Maximum applicable load (deformation 3 mm):

19,51 N/mm2 Acoustic load:

from 1,3 to 2,4 N/mm2 96 | XYLOFON | STRUCTURAL NOISE


XYLOFON 90 CODES AND DIMENSIONS CODE

Shore

XYL90080 XYL90090 XYL90100 XYL90120 XYL90140 XYL90160

90

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

80 90 100 120 140 160

3,66 3,66 3,66 3,66 3,66 3,66

6,0 6,0 6,0 6,0 6,0 6,0

3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4

12 12 12 12 12 12

1/4 1/4 1/4 1/4 1/4 1/4

pcs 1 1 1 1 1 1

TABLE OF USE(1) CODE XYL90080 XYL90090 XYL90100 XYL90120 XYL90140 XYL90160

load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 176 129811 360 265522 198 146037 405 298713 220 162264 450 331903 264 194716 540 398283 308 227169 630 464664 352 259622 720 531045

compression for acoustic optimisation(2) [N/mm2] [psi] min max

2,2 319

4,5 653

reduction [mm] [mil] min

max

0,3 12

0,74 29

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

28,97 4202

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3) Compressive modulus Ec Dynamic elastic modulus E’5Hz -E’50Hz Damping factor tanδ5Hz - tanδ50Hz Compression set c.s. Compressive stress at 1 mm (1/32 in)strain σ 1mm Compressive stress at 2 mm (1/16 in) strain σ 2mm Compressive stress at 3 mm (1/8 in) strain σ3mm Dynamic stiffness s’(4) Max processing temperature (TGA) Reaction to fire Water absorption after 48h

ISO 10848 ISO 844 ISO 4664-1 ISO 4664-1 ISO 1856 ISO 844 ISO 844 ISO 844 ISO 9052 EN 13501-1 ISO 62

> 7 dB 36,56 MPa 39,89 MPa - 65,72 MPa 0,307 - 0,453 2,02% 5,83 N/mm2 14,41 N/mm2 28,97 N/mm2 > 2200 MN/m3 200 °C class E < 1%

5303 psi 6150 psi - 8093 psi 846 psi 2090 psi 4202 psi 392 °F -

(3)Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 7 dB Maximum applicable load (deformation 3 mm):

29,87 N/mm2 Acoustic load:

from 2,2 to 4,5 N/mm2 STRUCTURAL NOISE | XYLOFON | 97


XYLOFON | Recommendations for installation APPLICATION WITH STAPLES

1a

2a

1b

2b

3

4

5

6

98 | XYLOFON | STRUCTURAL NOISE


APPLICATION WITH PRIMER SPRAY

1

2

3

4

APPLICATION WITH DOUBLE BAND

1

2

3

4 STRUCTURAL NOISE | XYLOFON | 99


FLANKSOUND

XYLOFON | Tests performed

LCA

EPD

LCA

EPD

EN ISO 10848

ETA-23/0061

EUROPEAN TECHNICAL ASSESSMENT The European Technical Assessment (ETA) provides an independent Europe-wide procedure for assessing the essential performance characteristics of non-standard construction products.

Δl,ij > 6 dB

• Certificate of suitability for reducing flanking sound transmission and vibration within structures • Kij measured for different hardnesses and with appropriate fastening system

Theoretical reduction of up to more than 15 dB when used as a vibration damper

SOUND REDUCTION INDEX MEASUREMENTS At the University of Innsbruck, a new laboratory was set up to measure the sound reduction index of CLT buildings with the aim of determining the effectiveness of the resilient profiles to be installed between the walls and floor.

ΔRDf+Ff,situ = 5 dB ΔSTC

Df+Ff,situ

= 4 dB

ΔRDf+Ff,situ = 10 dB ΔSTC

Df+Ff,situ

= 10 dB

IMPACT NOISE LEVEL MEASUREMENTS In this laboratory, it is also possible to measure the impact noise level in CLT buildings and to measure the effectiveness of resilient profiles placed between the walls and the floor.

ΔLn,Df+Ff,situ = 7 dB ΔIIC

Df+Ff,situ

100 | XYLOFON | STRUCTURAL NOISE

= 7 dB

ΔLn,Df+Ff,situ = 8 dB ΔIIC

Df+Ff,situ

= 8 dB


INTEGRATED DESIGN - FLANKSOUND PROJECT Rothoblaas has financed research projects aimed at measuring the Kij vibration reduction index for a variety of CLT panel joints, with the dual objective of providing specific experimental data for acoustic design and contributing to the development of analytical calculation methods.

• Influence of CLT type and thickness • Influence of type and number of screws • Influence of type and number of angle brackets and connectors • Influence of XYLOFON

Kij for 15 different types of joint

FIRE Awareness of fire design is increasingly growing. Over the years, Rothoblaas has carried out numerous tests to increase its know-how on this subject and will continue to do so in the future. Characterisation tests for EI behaviour were carried out at the ETH Zürich and the Institute of Structural Engineering (IBK) & Swiss Timber Solutions AG. After 60 minutes of exposure to fire, the temperature of the unexposed surface remained about room temperature, showing no colour changes. Rothoblaas was also a partner in the research project "Fire Safe implementation of visible mass timber in tall buildings", sponsored by RISE - Research Institutes of Sweden. This project made it possible to study the compartmentalisation of timber buildings and to analyse the limits of structures with exposed CLT.

experimental test EI 60

More information on RISE Report 2021:40.

STATICS AND ACOUSTICS Rothoblaas also subsidised research campaigns aimed at characterising the mechanical behaviour of connections incorporating the resilient XYLOFON profile. This was in cooperation with the Universities of Bologna, Innsbruck and Graz. Thanks to these studies, it was possible to optimise the thickness and material of XYLOFON to ensure a balance between static and acoustic performance.

• Influence of XYLOFON with different screw diameters • Influence of XYLOFON in nail connections • Testing of timber-to-timber joints • Tests on timber-to-steel joints • Influence of friction in shear connections

over 100 specimens tested

Use the QR-code to download the complete manual! www.rothoblaas.com STRUCTURAL NOISE | XYLOFON | 101


XYLOFON WASHER SEPARATING WASHER FOR TIMBER SCREW AND WHT

ACOUSTIC PERFORMANCE It improves soundproofing by decoupling of timber-to-timber joints made with screws and WHT.

STATICS The washer increases the rope effect in the connection, thus improving the static performance of the detail.

CODES AND DIMENSIONS dint

SEPARATING WASHER FOR SCREWS CODE

dSCREW

XYLW803811

Ø8 - Ø10 5/16 - 3/8

dext

dint

s

dext

dint

s

[mm]

[mm]

[mm]

[in]

[in]

[in]

pcs

38

11

6,0

1 1/2

7/16

1/4

50

pcs

s

dext

SEPARATING WASHER FOR WHT CODE

WHT

Ø

P

B

s

[mm] [mm] [mm] [mm]

Ø

P

B

s

[in]

[in]

[in]

[in]

23

7/8

2 3/8

2 3/8

1/4

Ø s

WHT340 XYLW806060

WHT440

60

60

6,0

10

WHT540 XYLW808080

WHT620

27

80

80

6,0

1 1/16

3 1/8

3 1/8

1/4

10

XYLW8080140

WHT740

30

80

140

6,0

1 3/16

3 1/8

5 1/2

1/4

1

P

B

RELATED PRODUCTS

HBS

ULS 440

WHT

COUNTERSUNK SCREW FOR WOOD

WASHER

ANGLE BRACKET FOR TENSILE LOADS

For more information on the products, go to www.rothoblaas.com.

TESTED The static performance was tested at the University of Innsbruck for use in safe static calculations.

SAFE Thanks to its polyurethane blend (80 shore), it is extremely chemically stable and resistant to creep deformation.

102 | XYLOFON WASHER | STRUCTURAL NOISE


7 x HBS 8x280/8

/3s

1000 135

CLT 90

0

XYLOFON WASHER | Tests performed plain bearing

plain bearing

90 300 EXPERIMENTAL INVESTIGATION

TEST [ T-X-W ]

HBS Ø8

plain bearing

(CLT - XYLOFON35 + XYLOFON WASHER - CLT)

F =

+ =

+

+

F force application XYLOFON35

XYLOFON35

pre-tensioning

F

+ =

ER

XYLOFON35

N WASH

XYLOFON35

+

XYLOFO

ER ER N WASHN WASH XYLOFOXYLOFO

F

plain bearing

(CLT - XYLOFON35 - CLT)

XYLOFON HBS Ø8 WASHER

METAL WASHER

TEST [ T-X ]

METAL XYLOFON WASHER WASHER

Through experimental testing and analytical approaches, the mechanical and deformation performance of connections made with HBS 8x280 screws between CLT panels installed with or without XYLOFON WASHER separating washers was analysed.

METAL WASHER XYLOFON WASHER HBS Ø8

plain bearing

SERIES

T-X

Fmean(1)

FR,k

pre-tens.(2)

Kser

Ku

[kN]

[kN]

[kN]

[N/mm]

[N/mm]

54,4

40,1

0

7114

3629

70,9

60,5

30

9540

4726

SERIES

T-X-W

Fmean(1)

FR,k

pre-tens.(2)

Kser

Ku

[kN]

[kN]

[kN]

[N/mm]

[N/mm]

65,0

48,3

0

6286

4330

76,2

63,4

30

7997

5080

(1) Average value for 3 tests. (2) Preload forces of 30 kN were applied to simulate the operating load.

F

N WASH

XYLOFO

By adding XYLOFON WASHER separating washers, there is an increase FR,k related to the increase of the axial resistance of METAL the connection XYLOFON35 (rope effect). WASHER + +

XYLOFON WASHER HBS Ø8

ER

Use the QR-code to download = the complete manual! www.rothoblaas.com

PERFORMANCE Acoustic performance

Kij = 18 dB Kij: vibration reduction index (data estimated from experimental measurements)

See the manual for more information on configuration.

STRUCTURAL NOISE | XYLOFON WASHER | 103


FLANKSOUND

XYLOFON PLATE

EN ISO 10848

ETA-11/0496 ETA-22/0089

SEPARATING PROFILE FOR TIMBER SHEAR BRACKET ANGLES

ACOUSTIC BRIDGES The excellent shear strength of the angle bracket and the sound-absorbing power of the profile allow acoustic bridges to be limited.

CE MARKING FROM ETA The profile is covered by the CE marking from ETA-11/0496 and ETA-22/0089 of the angle brackets, ensuring reliability and quality.

CODES AND DIMENSIONS SEPARATING PROFILE FOR TITAN CODE XYL3570200

TITAN TTF200

P

B

s

P

B

s

[mm]

[mm]

[mm]

[in]

[in]

[in]

70

200

6,0

2 3/4

8

1/4

pcs s 10

XYL35120240

TTN240 - TTS240

120

240

6,0

4 3/4

9 1/2

1/4

10

XYL35100200

TCF200 - TCN200

100

200

6,0

4

8

1/4

10

B P

SEPARATING PROFILE FOR NINO CODE

NINO

P

B

s

P

B

s

[mm]

[mm]

[mm]

[in]

[in]

[in]

pcs

XYL3580105

NINO100100

80

105

6,0

3 1/8

4 1/8

1/4

10

XYL3555150

NINO15080

55

150

6,0

2 3/16

6

1/4

10

XYL35120105

NINO100200

120

105

6,0

4 3/4

4 1/8

1/4

10

s P

B

For more information on TITAN and NINO see the data sheets at www.rothoblaas.com.

RANGE EXPANDED The range has expanded with new versions for NINO, the new angle bracket unit in the Rothoblaas family.

UNIFORM DEFORMATION Thanks to the monolithic polyurethane compound, the product ensures uniform deformation in the vicinity of the connection, minimally affecting the structural performance of the connections.

104 | XYLOFON PLATE | STRUCTURAL NOISE


XYLOFON PLATE | Tests performed MECHANICAL ACOUSTIC BEHAVIOUR

TITAN and NINO angle brackets, with a resilient XYLOFON PLATE profile, were subjected to a series of tests to understand their acoustic and mechanical behaviour. The experimental campaigns carried out within the SEISMIC-Rev project and in collaboration with multiple research institutes, have shown how the characteristics of the resilient profile influence the mechanical performance of the connection. From an acoustic point of view, with the Flanksound project, it has been demonstrated that the ability to dampen vibrations through the joint is strongly influenced by the type and number of connections.

Experimental investigations and tests on different configurations

FLANKSOUND PROJECT Rothoblaas invested in research projects aimed at measuring the Kij vibration reduction index for a variety of CLT panel joints, with the dual objective of providing specific experimental data for the acoustic design of CLT buildings and contributing to the development of calculation methods.

Values of Kij tested for 8 configurations with TITAN SILENT (TITAN angle bracket + XYLOFON PLATE)

800 300

MECHANICAL BEHAVIOUR Shear strength values tested and certified according to ETA. The specimens were brought to failure to investigate their maximum load and displacements.

Up to 34,6 kN shear strength with NINO and XYLOFON PLATE

Use the QR-code to download the complete manual! www.rothoblaas.com STRUCTURAL NOISE | XYLOFON PLATE | 105


PIANO

RESILIENT SOUNDPROOFING PROFILE

CERTIFIED, PRACTICAL AND CONVENIENT PIANO is the new resilient profile that reduces vibrations and provides good acoustic comfort, both in lightweight floors and in more complex, high-load buildings. Made of expanded and extruded EPDM blend, it is available in five versions. The elastic mix is able to compensate for expansion of the timber and structure, ensuring high durability and stability against chemical attack and UV radiation. In addition, the compact cross-section makes it more stable when crushed. PIANO is tested and certified for use as a desolidarisation and mechanical interruption layer between building materials. The acoustic performance tested in various applications ensures a noise reduction of 4-5 dB with a good cost-performance balance.

106 | PIANO | STRUCTURAL NOISE

ETA


COMPLETE RANGE Different versions are available to cover a wide load range, from floating floors to multi-storey buildings.

SMART Pre-cut in some versions to obtain more widths with fewer product codes. Although it comes in various colours, it can be installed between visible elements as it masks itself in the shadow of the gap.

DURABLE Extruded and expanded EPDM blend to optimise sound absorption. It offers high chemical stability and is VOC-free.

EASY INSTALLATION The different colours and moulds on the profiles make it easier to choose and identify the profile, both during installation and on site. Dry installation with mechanical fastening.

CODES AND DIMENSIONS CODE

B

L

s

B

L

s

pcs

[mm]

[m]

[mm]

[in]

[ft]

[in]

PIANOA4040

80

10

6

3 1/8

33

1/4

1

PIANOA5050

100

10

6

4

33

1/4

1

PIANOA6060

120

10

6

4 3/4

33

1/4

1

PIANOA140

140

10

6

5 1/2

33

1/4

1

PIANOB4040

80

10

6

3 1/8

33

1/4

1

PIANOB5050

100

10

6

4

33

1/4

1

PIANOB6060

120

10

6

4 3/4

33

1/4

1

PIANOB140

140

10

6

5 1/2

33

1/4

1

PIANOC080

80

10

6

3 1/8

33

1/4

1

PIANOC100

100

10

6

4

33

1/4

1

PIANOC120

120

10

6

4 3/4

33

1/4

1

PIANOC140

140

10

6

5 1/2

33

1/4

1

PIANOD080

80

10

6

3 1/8

33

1/4

1

PIANOD100

100

10

6

4

33

1/4

1

PIANOD120

120

10

6

4 3/4

33

1/4

1

PIANOD140

140

10

6

5 1/2

33

1/4

1

PIANOE080

80

10

6

3 1/8

33

1/4

1

PIANOE100

100

10

6

4

33

1/4

1

PIANOE120

120

10

6

4 3/4

33

1/4

1

PIANOE140

140

10

6

5 1/2

33

1/4

1

STRUCTURAL NOISE | PIANO | 107


PRODUCT COMPARISON products

thickness

acoustic improvement Δl,ij(1)

compressive modulus Ec

acoustic load / maximum applicable load 0

5

10

15

20

acoustic load [N/mm 2]

0,008 PIANO A

6 mm 1/4 in

> 4 dB

0,052

0,23 N/mm2 33 psi

maximum applicable load [N/mm 2]

0,008

0,15

acoustic load [N/mm 2]

0,04 PIANO B

6 mm 1/4 in

> 4 dB

0,286

1,08 N/mm2 157 psi

maximum applicable load [N/mm 2]

0,04

0,85

acoustic load [N/mm 2]

0,26 PIANO C

6 mm 1/4 in

> 4 dB

1,4

7,92 N/mm2 1449 psi

maximum applicable load [N/mm 2]

0,26

12,07

acoustic load [N/mm 2]

1,2 PIANO D

6 mm 1/4 in

> 4 dB

2,28

22,1 N/mm2 3205 psi

maximum applicable load [N/mm 2]

16,9

1,2

acoustic load [N/mm 2]

1,8 PIANO E

6 mm 1/4 in

> 4 dB

24,76 N/mm2 3591 psi

maximum applicable load [N/mm 2]

1,8

(1) Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

LEGEND: load for acoustic optimisation (resonance frequency 20-30 Hz) compressive stress at 3 mm (ultimate limit state)

108 | PIANO | STRUCTURAL NOISE

3,2

17,07

25


PIANO A CODES AND DIMENSIONS CODE

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

pcs

PIANOA4040

80

10

6

3 1/8

33

1/4

1

PIANOA5050

100

10

6

4

33

1/4

1

PIANOA6060

120

10

6

4 3/4

33

1/4

1

PIANOA140

140

10

6

5 1/2

33

1/4

1

TABLE OF USE(1) load for acoustic optimisation(2) [kN/m] [lbf/ft]

B

CODE

[mm] PIANOA4040 PIANOA5050 PIANOA6060

80

min 0,64

40 (divided) 0,32

max

472

4,16

236

2,08

1534

0,8

590

5,2

3835

50 (divided)

0,4

295

2,6

1918

120

0,96

708

6,24

4602

60 (divided) 0,48

354

3,12

2301

826

7,28

5369

140

1,12

reduction [mm] [mil]

min

max

min

max

0,008 1.2

0,052 7.5

0,2 8

1,35 53

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

3068

100

PIANOA140

compression for acoustic optimisation(2) [N/mm2] [psi]

0,15 22

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3)

ISO 10848

> 4 dB

-

Compressive modulus Ec

ISO 844

0,23 MPa

33 psi

Dynamic elastic modulus E’10Hz -E’50Hz

ISO 4664-1

0,5 MPa- 0,5 MPa

73 psi - 73 psi

Damping factor tanδ10Hz - tanδ50Hz

ISO 4664-1

0,19 - 0,24

-

Compressive stress at 1 mm (1/32 in)strain σ 1mm

ISO 844

0,04 N/mm2

6 psi

Compressive stress at 2 mm (1/16 in) strain σ 2mm

ISO 844

0,08 N/mm2

12 psi

Compressive stress at 3 mm (1/8 in) strain σ3mm

ISO 844

0,15 N/mm2

22 psi

Reaction to fire

EN 13501-1

class E

-

Water absorption after 48h

ISO 62

4,25%

-

(3) Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 4 dB Maximum applicable load (deformation 3 mm):

0,15 N/mm2 Acoustic load:

from 0,008 to 0,052 N/mm2 STRUCTURAL NOISE | PIANO | 109


PIANO B CODES AND DIMENSIONS CODE

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

pcs

PIANOB4040

80

10

6

3 1/8

33

1/4

1

PIANOB5050

100

10

6

4

33

1/4

1

PIANOB6060

120

10

6

4 3/4

33

1/4

1

PIANOB140

140

10

6

5 1/2

33

1/4

1

TABLE OF USE(1) load for acoustic optimisation(2) [kN/m] [lbf/ft]

B

CODE

[mm] PIANOB4040 PIANOB5050 PIANOB6060

min

80

3,2

40 (divided) 100

max

2360

21,6

1,6

1180

10,8

7966

4

2950

27

19914

50 (divided)

2

1475

13,5

9957

reduction [mm] [mil]

min

max

min

max

0,04 5.8

0,27 39.2

0,2 8

1,49 59

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

15931

120

4,8

3540

32,4 23897

60 (divided)

2,4

1770

16,2

140

5,6

4130

37,8 27880

PIANOA140

compression for acoustic optimisation(2) [N/mm2] [psi]

0,85 123

11949

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3)

ISO 10848

> 4 dB

-

Compressive modulus Ec

ISO 844

1,08

157 psi

Dynamic elastic modulus E’10Hz -E’50Hz

ISO 4664-1

1,9 MPa - 2,1 MPa

276 psi - 305 psi

Damping factor tanδ10Hz - tanδ50Hz

ISO 4664-1

0,3 - 0,4

-

Compressive stress at 1 mm (1/32 in)strain σ 1mm

ISO 844

0,14 N/mm2

20 psi

Compressive stress at 2 mm (1/16 in) strain σ 2mm

ISO 844

0,31 N/mm2

45 psi

Compressive stress at 3 mm (1/8 in) strain σ3mm

ISO 844

0,85 N/mm2

123 psi

Reaction to fire

EN 13501-1

class E

-

Water absorption after 48h

ISO 62

1,40%

-

(3) Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 4 dB Maximum applicable load (deformation 3 mm):

0,85 N/mm2 Acoustic load:

from 0,04 to 0,27 N/mm2 110 | PIANO | STRUCTURAL NOISE


PIANO C CODES AND DIMENSIONS CODE

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

pcs

PIANOC080

80

10

6

3 1/8

33

1/4

1

PIANOC100

100

10

6

4

33

1/4

1

PIANOC120

120

10

6

4 3/4

33

1/4

1

PIANOC140

140

10

6

5 1/2

33

1/4

1

TABLE OF USE(1) CODE

load for acoustic optimisation(2) [kN/m] [lbf/ft]

B [mm]

min

max

PIANOC080

80

9,6

7081

112

82607

PIANOC100

100

12

8851

140

103259

PIANOC120

120

14,4

10621

168

123910

PIANOC140

140

16,8

12391

196

144562

compression for acoustic optimisation(2) [N/mm2] [psi]

reduction [mm] [mil]

min

max

min

max

0,12 17.4

1,4 203.1

0,12 5

0,63 25

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

12,07 1751

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3)

ISO 10848

> 4 dB

-

Compressive modulus Ec

ISO 844

7,90 MPa

1449 psi

Dynamic elastic modulus E’10Hz -E’50Hz

ISO 4664-1

9,91 MPa - 11,61 MPa 1437 psi - 1684 psi

Damping factor tanδ10Hz - tanδ50Hz

ISO 4664-1

0,3 - 0,3

-

Compressive stress at 1 mm (1/32 in)strain σ 1mm

ISO 844

1,50 N/mm2

218 psi

Compressive stress at 2 mm (1/16 in) strain σ 2mm

ISO 844

3,55 N/mm2

514 psi

Compressive stress at 3 mm (1/8 in) strain σ3mm

ISO 844

9,23 N/mm2

1339 psi

Reaction to fire

EN 13501-1

class E

-

Water absorption after 48h

ISO 62

< 1%

-

(3) Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 4 dB Maximum applicable load (deformation 3 mm):

12,07 N/mm2 Acoustic load:

from 0,12 to 1,4 N/mm2 STRUCTURAL NOISE | PIANO | 111


PIANO D CODES AND DIMENSIONS CODE

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

pcs

PIANOD080

80

10

6

3 1/8

33

1/4

1

PIANOD100

100

10

6

4

33

1/4

1

PIANOD120

120

10

6

4 3/4

33

1/4

1

PIANOD140

140

10

6

5 1/2

33

1/4

1

TABLE OF USE(1) CODE

compression for acoustic optimisation(2) [N/mm2] [psi]

load for acoustic optimisation(2) [kN/m] [lbf/ft]

B [mm]

min

max

PIANOD080

80

96

70806

182,4

134531

PIANOD100

100

120

88507

228

168164

PIANOD120

120

144

106209 273,6 201797

PIANOD140

140

168

123910

reduction [mm] [mil]

min

max

min

max

1,2 174

2,28 330.7

0,33 13

0,62 24

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

16,9 2451

319,2 235430

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3)

ISO 10848

> 4 dB

-

Compressive modulus Ec

ISO 844

22,1 MPa

3205 psi

Dynamic elastic modulus E’10Hz -E’50Hz

ISO 4664-1

21,6 MPa - 26 MPa

3133 psi - 3771 psi

Damping factor tanδ10Hz - tanδ50Hz

ISO 4664-1

0,3 - 0,31

-

Compressive stress at 1 mm (1/32 in)strain σ 1mm

ISO 844

4,4 N/mm2

638 psi

Compressive stress at 2 mm (1/16 in) strain σ 2mm

ISO 844

10,49 N/mm2

1521 psi

Compressive stress at 3 mm (1/8 in) strain σ3mm

ISO 844

16,9 N/mm2

2451 psi

Reaction to fire

EN 13501-1

class E

-

Water absorption after 48h

ISO 62

< 1%

-

(3) Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 4 dB Maximum applicable load (deformation 3 mm):

16,9 N/mm2 Acoustic load:

from 1,2 to 2,28 N/mm2 112 | PIANO | STRUCTURAL NOISE


PIANO E CODES AND DIMENSIONS CODE

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

pcs

PIANOE080

80

10

6

3 1/8

33

1/4

1

PIANOE100

100

10

6

4

33

1/4

1

PIANOE120

120

10

6

4 3/4

33

1/4

1

PIANOE140

140

10

6

5 1/2

33

1/4

1

TABLE OF USE(1) CODE

compression for acoustic optimisation(2) [N/mm2] [psi]

load for acoustic optimisation(2) [kN/m] [lbf/ft]

B [mm]

min

max

PIANOE080

80

144

106209

256

188816

PIANOE100

100

180

132761

320

236020

PIANOE120

120

216

159313

384

283224

PIANOE140

140

252

185866

448

330428

reduction [mm] [mil]

min

max

min

max

1,8 261.1

3,2 464.1

0,44 17

0,77 30

compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi]

17,07 2476

(1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles

with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

USC conversion

Acoustic improvement Δl,ij(3)

ISO 10848

> 4 dB

-

Compressive modulus Ec

ISO 844

24,76 MPa

3591 psi

Dynamic elastic modulus E’10Hz -E’50Hz

ISO 4664-1

58,3 - 67 MPa

8456 psi - 9718 psi

Damping factor tanδ10Hz - tanδ50Hz

ISO 4664-1

0,24 - 0,25

-

Compressive stress at 1 mm (1/32 in)strain σ 1mm

ISO 844

3,81 N/mm2

553 psi

Compressive stress at 2 mm (1/16 in) strain σ 2mm

ISO 844

8,36 N/mm2

1213 psi

Compressive stress at 3 mm (1/8 in) strain σ3mm

ISO 844

17,07 N/mm2

2476 psi

Reaction to fire

EN 13501-1

class E

-

Water absorption after 48h

ISO 62

< 1%

-

(3) Δ

l,ij = Kij,with - Kij,without. See the manual for more information on configuration.

PERFORMANCE Acoustic improvement tested:

Δl,ij(3) : > 4 dB Maximum applicable load (deformation 3 mm):

17,07 N/mm2 Acoustic load:

from 1,8 to 3,2 N/mm2 STRUCTURAL NOISE | PIANO | 113


PIANO | Recommendations for installation APPLICATION WITH STAPLES

1

2

3

2

3

2

3

2

3

APPLICATION WITH PRIMER SPRAY

1 APPLICATION WITH DOUBLE BAND

1 APPLICATION ON BATTENS

1 114 | PIANO | STRUCTURAL NOISE


PIANO | Tests carried out EUROPEAN TECHNICAL ASSESSMENT he European Technical Assessment (ETA) provides an independent Europe-wide procedure for assessing the essential performance characteristics of non-standard construction products.

• Certified values for application as a resilient profile within structures • Kij measured for all hardnesses

Δl,ij > 4 dB

ANTI-VIBRATION PIANO dampens vibrations in both static and dynamic conditions due to its ability to absorb and dissipate the energy of the system.

Theoretical reduction of up to 10 dB when used as a vibration damper

• Application with static loads (e.g. buildings) • Application with dynamic loads (e.g. machines, bridges)

STATICS AND ACOUSTICS Rothoblaas promoted a research campaign aimed at characterising the mechanical behaviour of connections in the presence of the resilient profile. Thanks to this project, it was also possible to learn about the influence of PIANO in shear connections and to optimise thickness and material type in order to ensure a perfect cost/performance ratio.

• Influence of PIANO in the presence of screws and nails • Testing of timber-to-timber joints

possibility of knowing the influence of PIANO in shear connections

Use the QR-code to download the complete manual! www.rothoblaas.com STRUCTURAL NOISE | PIANO | 115


CORK ECOLOGICAL PANEL FOR ACOUSTIC INSULATION

SUSTAINABLE BUILDING It significantly reduces the transmission of airborne and structural noise. Natural VOC-free cork is ideal for structures where the goal is to minimise environmental impacts during construction.

PACKAGING Marketed both in 10 x 100 cm strips and in 50 x 100 cm panels that can be easily shaped. It can be used as a wall profile or floor layer.

TESTED Natural cork agglomerate mechanically tested by Industrial Research Centre of the University of Bologna.

116 | CORK | STRUCTURAL NOISE


CODES AND DIMENSIONS CODE

version

CORK410

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[in]

[in]

SOFT CORK410100 (410 kg/m3)

500

1

5

100

1

5

CORK850

500

1

5

100

1

5

HARD CORK850100 (850 kg/m3)

19 3/4 39 3/8

pcs

3/16

1

39 3/8

3/16

1

19 3/4 39 3/8

3/16

1

3/16

1

4 4

39 3/8

L

B

L

B

TABLE OF USE(1) B

CODE

compression for acoustic optimisation(2) [N/mm2] [psi]

load for acoustic optimisation(2) [kN/m] [lbf/ft]

[mm]

min

max

min

reduction [mm] [mil]

max

min

max

CORK410

100

20

14751

75

55317

0,2

29

0,75

109

0,25

10

1,5

59

CORK850

100

75

55317

300

221269

0,75

109

3

435

0,25

10

1

39

(1) The load ranges reported here are optimised with respect to the static behaviour of the material assessed under compression, considering the effect of friction and

the system resonance frequency, which falls between 20 and 30 Hz, with a maximum deformation of 12%. See the manual or use MyProject to view transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA CORK SOFT (410 kg/m3) (0.24 oz/in3) Properties

standard

value

USC conversion

Dynamic stiffness s’

UNI 29052

246 MN/m3

-

Density

-

410 kg/m3

0.24 oz/in3 109 psi

Maximum permissible load

-

0,75 N/mm2

Tensile strength

-

1,25 N/mm2

181 psi

Water absorption 48h

-

15%

-

Reaction to fire

EN 13501-1

class E

-

Max processing temperature

-

≥ 100°C

-

standard

value

USC conversion

CORK HARD (850 kg/m3) (0.49 oz/in3) Properties Dynamic stiffness s’

UNI 29052

1211 MN/m3

-

Density

-

850 kg/m3

0.49 oz/in3

Maximum permissible load

-

6,5 N/mm2

943 psi

Tensile strength

-

1,5 N/mm2

218 psi

Water absorption 48h

-

15%

-

Reaction to fire

EN 13501-1

class E

-

Max processing temperature

-

≥ 100°C

-

LIVING COMFORT The compactness of the cork agglomerate makes it waterproof, so it can be used both on concrete and masonry for protection against rising damp and as a wall barrier.

STRUCTURAL NOISE | CORK | 117


ALADIN

RESILIENT SOUNDPROOFING PROFILE

TESTED, SMART AND ECONOMICAL Despite a reduced thickness of use, the soundproofing profile ALADIN STRIPE offers an effective reduction of noise from footsteps, verified and approved in accordance with the standard EN ISO 10848 both by the certification body Holzforschung Austria, and by the Industrial Research Centre of the University of Bologna. It is precut to obtain four different widths with only two versions: ALADIN STRIPE SOFT in compact extruded EPDM and ALADIN STRIPE EXTRA SOFT in expanded EPDM. The product has been also tested for fire performance, achieving class E.

118 | ALADIN | STRUCTURAL NOISE

FLANKSOUND

EN ISO 10848


HIGH PERFORMANCE Soundproofing up to 4 dB in accordance with EN ISO 140-7, thanks to the innovative composition of the mixture; reduced application thickness.

PRACTICAL Pre-cut to obtain 4 different widths with only two versions. Dry installation with mechanical fastening.

RELIABLE Extruded and expanded EPDM blend to optimise sound absorption. It also offers high chemical stability and is VOC-frees.

CODES AND DIMENSIONS CODE

version

B

L

s

B

L

s

pcs

[mm]

[m]

[mm]

[in]

[ft]

[in]

ALADIN115

EXTRA SOFT

115

50

7

4 1/2

164

9/32

1

ALADIN95

SOFT

95

50

5

3 3/4

164

3/16

1

ALADIN EXTRA SOFT

s

B

ALADIN SOFT

s B

STRUCTURAL NOISE | ALADIN | 119


ALADIN EXTRA SOFT TABLE OF USE(1) CODE

ALADIN115

load for acoustic optimisation(2) [kN/m] [lbf/ft]

B [mm]

[in]

115

4 1/2

4

from 2969

18

a 13317

57,5 (divided)

2 1/4

2

1484

9

6658

compression for acoustic optimisation(2) [N/mm2] [psi] from a

from

a

0,035 5.1

0,7 28

2 79

reduction [mm] [mil]

0,157 22.8

(1) See the manual or use MyProject to view transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties Acoustic improvement ΔL'nT,w

(3)

standard

value

ISO 10848

4 dB

Dynamic stiffness s' (airtight condition)(4)

UNI 29052

76 MN/m3

Dynamic stiffness s' (non-airtight condition) (4)

UNI 29052

23 MN/m3

Density

ASTM D 297

0,50 g/cm3

Compression set 50% (22h, 23°C)

EN ISO 815

≤ 25%

Compression set 50% (22h, 40°C)

EN ISO 815

≤35%

Water absorption 48h

-

3%

Reaction to fire

EN 13501-1

class E

Max processing temperature

-

100°C

(3)See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load. The contribution of air is not calculated because

the product is extremely impermeable to air (extremely high flow resistance figures).

ALADIN SOFT TABLE OF USE(1)

ALADIN95

load for acoustic optimisation(2) [kN/m] [lbf/ft]

B

CODE [mm]

[in]

95

3 3/4

47,5 (divided)

from

a

18

13243

30

22142

9

6621

15

11071

compression for acoustic optimisation(2) [N/mm2] [psi] from a

from

a

0,189 27.4

0,5 20

1,5 59

0,316 45.8

reduction [mm] [mil]

(1) See the manual or use MyProject to view transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according

to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk).

TECHNICAL DATA Properties

standard

value

Acoustic improvement ΔL'nT,w(3)

ISO 10848

3 dB

Dynamic stiffness s' (airtight condition)(4)

UNI 29052

221 MN/m3

Dynamic stiffness s' (non-airtight condition) (4)

UNI 29052

115 MN/m3

Density

ASTM D 297

1,1 g/cm3

Compression set 50% (22h, 70°C)

EN ISO 815

50%

Tensile strength

EN ISO 37

≥ 9 N/mm2

Elongation at failure

EN ISO 37

≥ 500%

Water absorption 48h

-

< 1%

Reaction to fire

EN 13501-1

class E

Max processing temperature

-

100°C

(3)See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load. The contribution of air is not calculated because

the product is extremely impermeable to air (extremely high flow resistance figures).

120 | ALADIN | STRUCTURAL NOISE


ALADIN | Tests performed INTEGRATED DESIGN - FLANKSOUND PROJECT Rothoblaas has promoted research projects aimed at measuring the Kij vibration reduction index for a variety of CLT panel joints, with the dual objective of providing specific experimental data for the acoustic design and contributing to the development of calculation methods.

• influence of CLT type and thickness • influence of type and number of screws • influence of type and number of angle brackets and connectors • effectiveness of ALADIN

Kij measured according to ISO EN 10848

MEASUREMENTS ON SITE In order to know the behaviour of its products inside buildings, Rothoblaas also invests in on-site measurement campaigns. The effectiveness of ALADIN has resulted in highly satisfactory impact noise levels.

L’nT,w = 34 dB NIRSASTM = 75

STATICS AND ACOUSTICS As part of the Seismic Rev project, in cooperation with the University of Trento and CNR IVALSA, preliminary assessment was done of the mechanical behaviour of the TITAN when paired with ALADIN.

Experimental data on the static performance of a timber-to-steel connection with ALADIN interposed

Use the QR-code to download the complete manual! www.rothoblaas.com STRUCTURAL NOISE | ALADIN | 121


TRACK RESILIENT SOUNDPROOFING PROFILE

COST-PERFORMANCE Composition of the mixture optimised to provide both good performance and low cost.

FUNCTIONAL Reduces flanking transmission of vibrations and improves airtightness.

CODES AND DIMENSIONS CODE TRACK85

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

85

50

4,5

3 3/8

164

3/16

pcs s B

1

TECHNICAL DATA Properties

standard

value

Hardness

EN ISO 868

65 ± 5 Shore A

Density

ASTM D 297

1,2 g/cm3

Tensile strength

EN ISO 37

≥ 7,5 N/mm2

Elongation at break point

EN ISO 37

≥ 250%

Compression set 50% (70h, 70°C)

EN ISO 815

35%

Max processing temperature

-

90 °C

MATERIAL Synthetic rubber in compact extruded EPDM. High chemical stability, it does not contain harmful substances.

STABLE Thanks to the solid EPDM mix, it endures over time. It is not affected by chemical attacks.

122 | TRACK | STRUCTURAL NOISE


ALADIN & TRACK | Recommendations for installation APPLICATION WITH STAPLES

1

2

3

APPLICATION WITH PRIMER SPRAY

1

2

3

4

APPLICATION WITH DOUBLE BAND

1

2

3

STRUCTURAL NOISE | ALADIN & TRACK | Recommendations for installation | 123


GRANULO STRIPE RESILIENT GRANULAR RUBBER SOUNDPROOFING PROFILE

ANTI-VIBRATION The thermal-bonded rubber granules dampen vibrations, thus insulating the noise produced by footsteps.

WALL BARRIER Resilient strip for decoupling vertical partitions from ceilings.

CODES AND DIMENSIONS CODE GRANULO100

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

100

15

4

4

9/16

3/16

pcs

s B

1

TECHNICAL DATA Properties

standard

value

Hardness

-

50 shore A

Density

-

750 kg/m3

ISO 29052-1

66 MN/m3

ISO 12354-2

22,6 dB

ISO 12354-2

116.3 Hz

10% deformation

-

21 kPa

Apparent dynamic stiffness s’t Theoretical estimate of the degree of footstep attenuation ΔLw System resonance frequency f0 (1)

(1)

Compression deformation stress 25% deformation

-

145 kPa

Elongation at failure

-

27 %

Thermal conductivity λ

UNI EN 12667

0,033 W/mK

(1)Value calculated according to EN ISO 12354-2 for impact sound insulation underscreed products considering a load condition m’=125 kg/m2.

MATERIAL Mix of natural and synthetic elastomers bound by polymerised polyurethane.

MULTIFUNCTIONAL Also available in other formats, ideal for outdoor applications as structural substrates (PAD, ROLL and MAT).

124 | GRANULO STRIPE | STRUCTURAL NOISE


GRANULO PAD

RESILIENT SUPPORT FOR BATTENS AND RIBS OF FLOORS OR TERRACES CODES AND DIMENSIONS CODE GRANULOPAD

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[in]

[in]

80

0,08

10

3 1/8

3 1/8

3/8

pcs 20

TECHNICAL DATA Properties

standard

value

Dynamic stiffness s’

UNI 29052

48 MN/m3

Theoretical estimate of the degree of footstep attenuation ΔLw(1)

ISO 12354-2

24,2 dB

(1)

ISO 12354-2

99,1 Hz

System resonance frequency f0

(1)Value calculated according to EN ISO 12354-2 for impact sound insulation underscreed products considering a load condition m’=125 kg/m2.

GRANULO ROLL

RESILIENT PROFILE FOR BATTENS AND RIBS OF FLOORS OR TERRACES CODES AND DIMENSIONS CODE GRANULOROLL

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

80

6

8,0

3 1/8

19.7

5/16

pcs 1

TECHNICAL DATA Properties

standard

value

Dynamic stiffness s’

UNI 29052

50 MN/m3

Theoretical estimate of the degree of footstep attenuation ΔLw(1)

ISO 12354-2

23,9 dB

(1)

ISO 12354-2

101,2 Hz

System resonance frequency f0

(1)Value calculated according to EN ISO 12354-2 for impact sound insulation underscreed products considering a load condition m’=125 kg/m2.

GRANULO MAT RESILIENT SUBSTRATE FOR SCREEDS AND TERRACES CODES AND DIMENSIONS CODE GRANULOMAT

B

L

s

B

L

[mm]

[m]

1250

10

s

[mm]

[in]

[ft]

[in]

6,0

49 3/16

33

1/4

pcs 1

TECHNICAL DATA Properties

standard

value

Dynamic stiffness s’

UNI 29052

118 MN/m3

Theoretical estimate of the degree of footstep attenuation ΔLw(1)

ISO 12354-2

18,6 dB

(1)

ISO 12354-2

155,5 Hz

System resonance frequency f0

(1)Value calculated according to EN ISO 12354-2 for impact sound insulation underscreed products considering a load condition m’=125 kg/m2.

STRUCTURAL NOISE | GRANULO STRIPE | 125


TIE-BEAM STRIPE TIE BEAM SEALING PROFILE

ADJUSTABLE Flexible profile is easy to work, thanks to the soft and shapeable mixture.

WATERPROOFING Resilient profile to connect tie beam and brickwork/concrete.

CODES AND DIMENSIONS CODE TIEBEAM71

B

L

s

B

L

s

[mm]

[m]

[mm]

[in]

[ft]

[in]

71

50

9

2 3/4

164

3/8

pcs s B

1

TECHNICAL DATA Properties

standard

value

Hardness

EN ISO 868

50 shore A

Density

ASTM D 297

1,1 g/cm3

Breaking load

EN ISO 37

≥ 9 MPa

Elongation at break point

EN ISO 37

≥ 500%

Compression set 50% (22h, 100°C)

EN ISO 815

< 50%

Max processing temperature

-

90 °C

Storage temperature

-

+5 / +25 °C

SMART The pre-formed profile adapts well to surfaces, ensuring air and water tightness at all times. It can also be used vertically as a seal between walls.

STRENGTH Its profile ensures great elasticity and resistance even in the event of perforations and mechanical fastening , thanks to the special modified EPDM compound.

126 | TIE-BEAM STRIPE | STRUCTURAL NOISE


THE BEST ATTACK IS DEFENCE

A well-designed ground connection ensures the durability of your timber building and plays mainly in defence: it protects against capillary rising damp and interstitial condensation. It integrates the ALU START aluminium ground connection system with waterproofing profiles, bituminous membranes and butyl bands. It increases the durability of the building by playing defence.

Scan the QR code and discover the technical features of waterproofing products. www.rothoblaas.com


NOISE REDUCTION: STAIRS AND STAIRWELL Stairs are often one of the critical points for noise transmission in buildings. The propagation and amplification of impact noise is often difficult to control and is linked to the particular conformation of stairs and stairwells: extremely rigid and capable of generating noise by structural means. In fact, the wall dividing the stairs from the adjacent room is often the main cause of sound diffusion between rooms. Effective soundproofing requires a great deal of design effort, which involves analysing the different types of materials and construction techniques used. To remedy the problem, structural elements must be separated by interposing resilient profiles and the floors must be insulated with impact-absorbing membranes.

01 Stair-landing arrival connection

01

02

03

02 Step-stair structure connection

04

03 Stair-landing departure connection

Explanatory section of timber staircase.

04 Landing-passing wall connection

Explanatory plan of timber staircase.

128 | NOISE REDUCTION: STAIRS AND STAIRWELL | STRUCTURAL NOISE


SOLID TIMBER STAIRCASE It is common practice to make staircases of solid wood with two stringers on which the steps rest. In order to improve acoustic performance, the steps must be decoupled from the stringers and the stringers from the side walls with which they come into contact. To do this, Rothoblaas recommends XYLOFON 20, PIANO A or ALADIN EXTRA SOFT. In the case of prefabricated staircases, it may be useful to use a Rothoblaas PE tape to help the staircase slide into the compartment.

glulam step

resilient profile

XYLOFON 20

PIANO A

ALADIN EXTRA SOFT

tape to facilitate sliding in the structure

glulam stringer

FLEXIBAND

CONCRETE STAIRCASE The problem of impact noise affects all types of stairs, including concrete ones. It is therefore important to separate the flights of stairs from landings with XYLOFON 20, XYLOFON 35, PIANO B or PIANO C and SILENT EDGE to reduce noise transmission to adjacent walls and floors.

XYLOFON 20

resilient profile

XYLOFON 35

PIANO B

PIANO C

SILENT EDGE

concrete staircase

STRUCTURAL NOISE | NOISE REDUCTION: STAIRS AND STAIRWELL | 129


TIMBER FRAME STAIRCASE XYLOFON

finish

timber riser and tread

resilient profile

In frame buildings, stairs are made with two moulded stringers to which risers and treads are attached. In order to improve the acoustic performance of stairs, Rothoblaas recommends using XYLOFON, PIANO or ALADIN to separate the structural elements (stringers, floor and walls) and XYLOFON 20, PIANO A, ALADIN EXTRA SOFT, CONSTRUCTION SEALING or SILENT UNDERFLOOR to separate the treads from the stringer.

PIANO

ALADIN

SILENT STEP ALU

shaped beam made of glulam

SILENT STEP

XYLOFON 20

PIANO A

ALADIN EXTRA SOFT SILENT UNFERFLOOR

STEEL STAIRCASE In steel staircases, as in all lightweight structures, it is essential to interrupt the propagation of vibrations. In order to have a reduction in noise transmission, it is advisable to use resilient products. XYLOFON 20, XYLOFON 35, PIANO A or PIANO B are ideal for isolating steel elements from the structure.

resilient profile

XYLOFON 20

step

shaped beam made of steel

130 | NOISE REDUCTION: STAIRS AND STAIRWELL | STRUCTURAL NOISE

PIANO A

PIANO B


CLT STAIRCASE It is also common for flights of stairs in CLT buildings to be constructed with a panel of CLT onto which the steps are fixed. In order to prevent the transmission of vibrations caused by walking, we recommend separating the CLT elements with XYLOFON, PIANO or ALADIN and separating the steps from the flight with XYLOFON 20; PIANO A, ALADIN EXTRA SOFT or SILENT UNDERFLOOR.

SILENT STEP ALU SILENT STEP finish

glulam step

CLT floor

XYLOFON 20

PIANO A

resilient profile

XYLOFON

PIANO

ALADIN

ALADIN EXTRA SOFT SILENT UNFERFLOOR

STRUCTURAL NOISE | NOISE REDUCTION: STAIRS AND STAIRWELL | 131



ACOUSTIC AND SEALING


ACOUSTIC AND SEALING


4

ACOUSTIC AND SEALING FIRE SEALING SILICONE HIGH FIRE-RESISTANT SILICONE SEALANT WITH ACOUSTIC PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . 140

MS SEAL MS POLYMER HIGH ELASTICITY SEALANT. . . . . . . . . . . . . . . . . . 143

HERMETIC FOAM HIGH PERFORMING SOUNDPROOFING SEALING FOAM . . . . . 144

EXPAND BAND SELF-EXPANDING SEALING TAPE. . . . . . . . . . . . . . . . . . . . . . . . . . 146

WINDOW BAND SELF-EXPANDING SEALING TAPE FOR WINDOWS/DOORS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

PLASTER BAND IN/OUT SPECIAL HIGH-ADHESION TAPE, CAN BE ALSO PLASTERED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150

SMART BAND UNIVERSAL SINGLE-SIDED TAPE WITH SEPARABLE LINER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158

ACOUSTIC AND SEALING | 135


WINDOW/DOOR FRAMES ACOUSTICS To ensure its effectiveness, a window/door must always be installed taking into account the principle of continuity of the wind and air tightness levels (see the ''TAPES, SEALANTS AND MEMBRANES'' catalogue available at www.rothoblaas.com). An improperly installed high-performance window or door frame will compromise the overall performance of the system and will not meet the needs of the end user.

WHAT IT MUST GUARANTEE

WHAT IT MUST RESIST UV RAYS

SOUNDPROOFING

HEAVY RAIN

ENERGY SAVING

TEMPERATURE CHANGES

ADJUSTMENT THERMO-HYGROMETRIC

WIND

HOUSING COMFORT

NOISE POLLUTION

NATURAL AERATION

FIRE

NATURAL LIGHTING ELASTIC RESPONSE

THREE LEVELS OF PROTECTION The three level method, which is used often in most European countries, identifies the airtightness, windtightness and thermal-acoustic insulation levels for proper placement of doors and windows. To obtain maximum performance, it is important to take care in all design stages: Rothoblaas offers specific solutions for each of the three levels.

WIND TIGHTNESS LEVEL

THERMAL AND ACOUSTIC INSULATION LEVEL

IN

OUT

IN

OUT

AIRTIGHTNESS LEVEL OUT

IN

The most external level must guarantees protection against weather. If not properly treated, it can lead to problems of infiltration and accumulation of stagnant water at the bottom of the window hole.

The intermediate level must guarantee thermal-acoustic performance and mechanical fixing. When choosing products, bear in mind that a good anti-noise solution is not always thermally effective.

The most internal level must be airtight. Its function is to prevent the passage of vapour laden air, which could create condensation in the joints and mould on the surface.

Rothoblaas offers: START BAND, PROTECT, BYTUM BAND, FLEXI BAND, FLEXI BAND UV, FACADE BAND UV, SOLID BAND, SMART BAND, PLASTER BAND, PLASTER BAND LITE, MANICA PLASTER, TERRA BAND, ALU BUTYL BAND, BLACK BAND, MS SEAL

Rothoblaas offers: EXPAND BAND, WINDOW BAND, FRAME BAND, EASY FOAM, HERMETIC FOAM, FIRE FOAM

Rothoblaas offers: SEAL BAND, FLEXI BAND, SOLID BAND, SMART BAND, PLASTER BAND, PLASTER BAND LITE, MANICA PLASTER, BLACK BAND, MS SEAL

136 | WINDOW/DOOR FRAMES ACOUSTICS | ACOUSTIC AND SEALING


PRIMARY JOINT AND SECONDARY JOINT INSTALLATION WITHOUT COUNTERFRAME

INSTALLATION WITH COUNTERFRAME

primary joint

primary joint fixed frame

leaf

leaf secondary joint counterframe

fixed frame

The PRIMARY JOINT is the first installation node between the structure and the counterframe. The SECONDARY JOINT is the junction between the counterframe and the frame. CORRECT DESIGN OF THE INSTALLATION JOINT

If the design or installation does not adequately take care of any of the three levels, there is a high probability of condensation and water infiltration into the structure.

The inner protection level is not sealed, but the outer level is sealed: there is a high risk of humidity-laden internal air penetrating the joints and forming condensation in the intermediate level.

The inner protection level is sealed, the outer level is not: the joint is not effectively protected against wind and rain from outside.

In this way, the three levels of protection are correctly designed and executed: the joint performs perfectly from an acoustic and thermo-hygrometric point of view.

70

70

60

60

50

50

40

R [dB]

These sound reduction index tests were carried out to study, from an acoustic point of view, the primary joint of a window/door frame-to-structure connection. In the first graph, the curves represent the sound reduction index of the joint where a crack has been created (orange line) and the sound reduction index of the same joint after the crack has been grouted (grey line). The increase ΔRw due to the restoration of the airtight layer is + 2 dB. The curves in the second graph represent the sound reduction index of the same primary joint that has been sealed once with self-expanding tape type EXPAND BAND or WINDOW BAND (orange line) obtaining an Rw of 41 (-2,-4) dB and once with polyurethane foam type HERMETIC FOAM or EASY FOAM (grey line) obtaining an Rw of 40 (-1,-3) dB.

R [dB]

AIR: MAIN MEDIUM OF PROPAGATION OF SOUND WAVES

40

30

30

20

20

125

250

500 1K f [Hz]

2K

4K

125

250

500 1K f [Hz]

2K

4K

R w = 39 (-1;-4) before intervention

R w = 41 (-2;-4) with KOMPRI BAND or FRAME BAND

R w = 41 (-2;-6) after intervention

R w = 40 (-1;-3) with SEALING FOAM

ACOUSTIC AND SEALING | WINDOW/DOOR FRAMES ACOUSTICS | 137


THE WINDOW AND DOOR INSTALLATION PLAN AND ITS EFFECTS Several factors determine this aspect: ranging from the building tradition of the place where the structure is built, the client’s habits, the type of construction chosen. However, it is important to consider that the choice of window/door frame installation plan has an impact on the temperature trend in the construction node, and therefore on the general effectiveness of the installation. Continuity with the insulating layer that may be present in the layers of the wall should be searched for.

INTERNAL FLUSH INSTALLATION Some traditional local systems prefer it because it allows the full opening of the window/door. However, this is not an optimal solution from a thermal point of view, as the window/door is moved inwards and the risk of low internal surface temperatures is greater. In order to avoid thermal bridges in buildings with external insulation, it is recommended that the side walls of the window hole are also insulated to join them to the external insulation.

thermal dispersion

CENTRAL FLUSH INSTALLATION It is the most common in traditional building systems. It is advisable to also insulate the side walls of the window hole in order to join them to the external insulation and avoid thermal bridges. For frame structures with an insulated gap, this solution is also suitable. The mechanical connection of the window/door is made directly to the load-bearing structure of the building.

thermal dispersion

EXTERNAL FLUSH INSTALLATION The external insulation must cover the fixed frame of the window/door and the subframe, if present, ensuring excellent internal surface temperatures. The mechanical connection of the window/door is made directly to the load-bearing structure of the building.

INSTALLATION IN THE INSULATION LAYER This solution is adopted in the most high-performance constructions. It allows the reduction of the linear thermal bridge value. It requires more care when installing the window/door and greater insulation thickness. The mechanical connection of the window/door frame to the structure can be made by means of an appropriately L or Z-shaped timber counterframe or by means of metal brackets. It is the configuration that allows for the best design of isothermal lines so as to avoid any thermal bridges.

138 | WINDOW/DOOR FRAMES ACOUSTICS | ACOUSTIC AND SEALING

thermal dispersion


MASONRY STRUCTURE

TIMBER FRAME STRUCTURE

INSTALLATION WITH FLUSH COUNTERFRAME

INSTALLATION WITHOUT CENTRAL COUNTERFRAME

FLEXI BAND FLEXI BAND UV SOLID BAND SMART BAND PLASTER BAND PLASTER BAND LITE

MS SEAL

PLASTER BAND PLASTER BAND LITE FLEXI BAND FLEXI BAND UV SOLID BAND SMART BAND FACADE BAND UV

TRASPIR UV

SEAL BAND EASY BAND FLEXI BAND PLASTER BAND PLASTER BAND LITE MANICA PLASTER

PLASTER BAND PLASTER BAND LITE EASY BAND SEAL BAND FLEXI BAND MANICA PLASTER

EXPAND BAND WINDOW BAND FRAME BAND EASY FOAM HERMETIC FOAM FIRE FOAM

EXPAND BAND WINDOW BAND FRAME BAND EASY FOAM HERMETIC FOAM FIRE FOAM

MS SEAL

SMART BAND START BAND PROTECT BYTUM BAND SOLID BAND MANICA PLASTER TERRA BAND ALU BUTYLBAND

SMART BAND SOLID BAND PROTECT BYTUM BAND FLEXI BAND PLASTER BAND

CLT STRUCTURE

CLT STRUCTURE INSTALLATION WITHOUT COUNTERFRAME FLUSH WITH THE OUTSIDE FRONT BAND UV

MS SEAL

MS SEAL

INSTALLATION WITH COUNTERFRAME

PLASTER BAND PLASTER BAND LITE FLEXI BAND FLEXI BAND UV SOLID BAND SMART BAND

PLASTER BAND PLASTER BAND LITE FLEXI BAND FLEXI BAND UV SOLID BAND SMART BAND FACADE BAND

SEAL BAND EASY BAND FLEXI BAND PLASTER BAND PLASTER BAND LITE MANICA PLASTER

SEAL BAND EASY BAND FLEXI BAND PLASTER BAND PLASTER BAND LITE MANICA PLASTER

EXPAND BAND WINDOW BAND FRAME BAND EASY FOAM HERMETIC FOAM FIRE FOAM

EXPAND BAND WINDOW BAND FRAME BAND EASY FOAM HERMETIC FOAM FIRE FOAM

SMART BAND SOLID BAND FLEXI BAND PLASTER BAND

MS SEAL

MS SEAL

SMART BAND START BAND PROTECT MANICA PLASTER BYTUM BAND SOLID BAND TERRA BAND ALU BUTYL BAND

ACOUSTIC AND SEALING | WINDOW/DOOR FRAMES ACOUSTICS | 139


FIRE SEALING SILICONE HIGH FIRE-RESISTANT SILICONE SEALANT WITH ACOUSTIC PERFORMANCE

NOISE REDUCTION The product was tested in different configurations at the University of Bologna according to C919-19 and ISO 10140-2:2021 achieving acoustic performance of up to 50 dB.

SAFETY For sealing linear joints in fire rated walls and doors, in situations subject to fire regulations.

FIRE PROTECTION AND SOUNDPROOFING FIRE SEALING SILICONE is a unique product as it provides maximum fire protection by achieving an EI240 with a B-s1,d0 fire rating.

140 | FIRE SEALING SILICONE | ACOUSTIC AND SEALING

EN 15651-1

EI 240

B-s1,d0


CODES AND DIMENSIONS content

content

[ml]

[US fl oz]

FIRESILGRE310

310

FIRESILIVO310

310

CODE

colour

version

10.48

grey

rigid cartridge

24

10.48

ivory

rigid cartridge

24

TECHNICAL DATA Properties

standard

value

USC conversion

Composition

-

silicone

-

Classification

EN 15651-1

F-EXT/INT-CC(1)

-

Density

ISO 1183-1

1,482 g/mL

237.65 oz/gal

Yield for 10x10 mm joint

-

3,1 m

10.7 ft

Surface cross-linking time 23 °C

-

approx. 80 min

-

Hardening speed 23 °C

-

approx. 2 mm in 24 h -

Shore A hardness

DIN 53505

approx. 30

-

Elongation at failure

DIN 53504

460%

-

Tensile strength

DIN 53504

0,72 N/mm2

104.43 lbf/in2

Compressive modulus 100%

DIN 53504

0,38 N/mm2

55.11 lbf/in2

Reaction to fire

EN 13501-1

class B-s1,d0

-

Fire resistance rating

EN 13501-2

EI 240 (2)

Acid resistance

-

excellent

-

Bases resistance

-

excellent

-

Emicode

GEV test procedure

EC1

-

French VOC classification

ISO 16000

A+

-

VOC content

-

4,3% / 64 g/L

-

Expiry(3)

-

up to 12 months

-

(1) Non-structural sealant for façade elements, for external and internal use, also in areas with cold climates. (2)Valid for tested configurations. (3)Store the product in a dry place and check the expiry date on the cartridge.

Waste classification (2014/955/EU): 08 04 09. Eye Dam. 1 . Skin Sens. 1B.

FIRE RESISTANCE EI 240 AND CLASS B-s1, d0 Tested protection, designed to offer maximum protection against the passage of flames, smoke or gases.

COLOURS Thanks to its two colours, it can also be installed unobtrusively in sealing linear joints of walls and fire doors, in situations subject to fire regulations.

ACOUSTIC AND SEALING | FIRE SEALING SILICONE | 141


FIRE SEALING SILICONE | Tests performed SOUND REDUCTION INDEX LEVEL MEASUREMENTS At the laboratories of the Building and Construction Research Centre - CIRI of the University of Bologna, tests were carried out according to ASTM C919 to characterise the sealant from an acoustic point of view. The application of silicone made it possible to restore the sound reduction index that the wall had lost when a crack was created in it.

plasterboard panels reaching down to the floor

plasterboard panels that do not touch the floor

plasterboard panels with FIRE SEALING SILICONE to restore sound reduction index

Rw (C;Ctr) = 50 (-2;-7) dB

Rw (C;Ctr) = 25 (0;-2) dB

Rw (C;Ctr) = 49 (-2;-8) dB

Use the QR-code to download the complete manual! www.rothoblaas.com

FIRE STRIPE GRAPHITE A 10 CONNECTION!

In contact with fire, FIRE STRIPE GRAPHITE increases its volume 10 times and provides maximum protection in the event of fire. Thanks to its composition and the addition of graphite, it increases fire resistance on timber-to-steel connections and fire doors.

Scan the QR code and discover the technical features of waterproofing products www.rothoblaas.com


MS SEAL

EN 15651-1

MS POLYMER HIGH ELASTICITY SEALANT

IT CAN BE PAINTED It can be overpainted with water-based paints commonly used in construction.

SAFE MS SEAL is pure, single-component, with practically no shrinkage, and offers an alternative for air-tightness in the case of visible sealing.

CODES AND DIMENSIONS content

content

[ml]

[US fl oz]

MSSEALWHI300

300

10.15

rigid cartridge

24

MSSEALGRE300

300

10.15

rigid cartridge

24

MSSEALWHI600

600

20.29

soft cartridge

12

MSSEALGRE600

600

20.29

soft cartridge

12

CODE

version

TECHNICAL DATA Properties

standard

value

USC conversion -

Classification

EN 15651-1

F-EXT/INT-CC(1)

Specific weight

-

1,5 kg/dm3

0.87 oz/in3

Surface cross-linking time 20 °C / 50% RH

-

approx. 20 min

-

Hardening speed 20 °C / 50 %RH

-

2,5 mm/24 h

0.1 in/24 h

Shore A hardness

DIN 53505

25

-

Elongation at failure

ISO 8339

400%

-

Elastic return

ISO 7389

> 70%

-

Application temperature

-

+5 / +35 °C

+41 / +95 °F

French VOC classification

ISO 16000

A+

-

VOC content

ISO 11890-2

9,2 g/L

-

Storage temperature(2)

-

+5 / +25 °C

+41 / +77 °F

(1) Non-structural sealant for façade elements, for external and internal use, also in areas with cold climates. (2)Store the product in a dry and covered place (12 months rigid cartridge/18 months soft cartridge). Check the expiry date on the packaging.

PERFORMANCE Excellent resistance to ageing and UV rays. Classified as a non-structural sealant for façade elements, for outdoor and indoor use, also in areas with cold climates (type F-EXTINT-CC) according to EN 15651-1.

UNIVERSAL Universal one-component sealant ideal for gluing and sealing the most common building materials.

ACOUSTIC AND SEALING | MS SEAL | 143


HERMETIC FOAM

GLOVES INCLUDED

HIGH PERFORMING SOUNDPROOFING SEALING FOAM

CERTIFIED NOISE REDUCTION Up to 63 dB noise reduction, certified by the IFT Rosenheim institution (ISO 10140-1).

AIRTIGHT EVEN AFTER TRIMMING Waterproof and airtight, even if trimmed after hardening, thanks to the closed-cell structure.

CODES AND DIMENSIONS CODE

content

yield

content

yield

cartridge

[ml]

[L]

[US fl oz]

[US gal]

HERFOAM

750

40

25.36

10.57

aluminium

12

HERFOAMB2

750

32

25.36

8.45

aluminium

12

TECHNICAL DATA HERFOAM Properties

standard

value

USC conversion

Composition

-

Single component PU

-

Colour

-

white

-

Film formation time 23 °C / 50% RH

-

6 - 10 min

-

Cutting time 23 °C / 50% RH

-

20 - 40 min

-

Time required for complete hardening 23 °C / 50% RH

-

60 min

-

FEICA TM1020/ EN 12667 EN ISO 10140-1 EN ISO 10140-2 EN ISO 717-1

0,030 - 0,035 W/(m∙K)

0.017 - 0.02 BTU/h∙ft∙°F

10 mm: ≥ 63 (-1;-5) dB

-

20 mm: ≥ 62 (-1;-5) dB

-

Water vapour resistance factor (μ)

EN 12086

36

-

Reaction to fire

DIN 4102-1 EN 13501-1

class B3 class F

-

Temperature resistance once hardened

-

-40 / +90 °C

-40 / +194 °F

Application temperature (cartridge, environment and support)

-

+5 / +35 °C

+41 / +95 °F

Emicode

GEV test procedure

EC1 plus

-

French VOC classification

ISO 16000

A+

-

VOC content

-

17,0 % - 173,3 g/L

-

Transport temperature

-

0 / +35 °C

+32 / +95 °F

Storage temperature(1)

-

+15 / +25 °C

+59 / +77 °F

Storage time(2)

-

12 months

-

Thermal conductivity (λ) Acoustic insulation of joints RS,w (ift)

(1)Store the product in a vertical position in a dry, covered location. (2) Check the expiry date on the cartridge.

Waste classification (2014/955/EU): 16 05 04. Aerosol 1. Acute Tox. 4.Acute Tox. 4.Skin Irrit. 2. Eye Irrit. 2.Resp. Sens. 1. Skin Sens. 1. Carc. 2. STOT SE 3. STOT RE 2

144 | HERMETIC FOAM | ACOUSTIC AND SEALING


TECHNICAL DATA HERFOAMB2 Properties

standard

value

USC conversion

Composition Colour Density Film formation time 20°C / 65% RH Cutting time 23 °C / 50% RH

-

Single component PU white 15-20 kg/m3 6-8 min 15-20 min class E class B2 -40 / +80 °C +5 / +35 °C +5 / +35 °C +5 / +35 °C +15 / +25 °C 12 months

-40 / +176 °F +41 / +95 °F +41 / +95 °F +41 / +95 °F +59 / +77 °F -

EN 13501-1 DIN 4102-1 -

Reaction to fire Temperature resistance once hardened Application temperature (cartridge) Application temperature (ambient) Application temperature (support) Storage temperature(1) Storage time(2) (1)Store the product in a vertical position in a dry, covered location. (2) Check the expiry date on the cartridge.

FIELDS OF APPLICATION

RELATED PRODUCTS

FLY FOAM

FOAM CLEANER

MARLIN

EMICODE EC1 PLUS Its low VOC content and very low emissions also make this foam perfect for indoor use.

HIGH ELASTICITY Thanks to its composition, it remains elastic and deformable over time, compensating for the movements of the wood and differential deformation of the building materials.

ACOUSTIC AND SEALING | HERMETIC FOAM | 145


EXPAND BAND

D DIN 18542 BG 1

SELF-EXPANDING SEALING TAPE

PERMANENT ELASTIC EXPANSION The tape self-expansion remains elastic and unchanged over time, providing protection from water, dust and wind.

SAFETY The modified polyurethane foam has passed the most stringent tests on harmful emissions, ensuring safe installation even indoors.

COMPOSITION EXPAND BAND elastic polyurethane foam with additives release liner silicone coated paper

EXPAND BAND EVO elastic polyurethane foam with special film additives

CODES AND DIMENSIONS EXPAND BAND CODE

B

s

[mm]

L

s

L

[m]

[in]

1

4

13

0.4

15

1

4

13

0.6

39

15

4

9

8

0.6

157

EXPAND15615

15

6

15

6

0.6

236

591

20

32

EXPAND20920

20

9

20

4

0.8

354

787

13

24

EXPAND40615

40

6

15

8

1.6

236

591

26

12

EXPAND60615

60

6

15

8

2.4

236

591

26

8

L

B

EXPAND1014

10

EXPAND1514 EXPAND1549

[mm]

B

[mil] 39

[ft] 157

43

48

157

43

32

354

26

32

EXPAND BAND EVO CODE

B

s

[mm] EXPANDEVO1514

15

[mm] 1

146 | EXPAND BAND | ACOUSTIC AND SEALING

4

[m]

[in]

13

0.6

s

L

[mil] 39

[ft] 157

43

32


TECHNICAL DATA Properties

standard

value

USC conversion

Classification

DIN 18542

BG 1

-

Airtightness

EN 12114

α ≤ 1,0 m3/(h·m·(daPa)n

Tightness in heavy rain

EN 1027

≥ 750 Pa

-

Resistance to UV and weathering

DIN 18542

compliant with class BG 1

-

Compatibility with other building materials

DIN 18542

compliant with class BG 1

-

Water vapour transmission (Sd)

EN ISO 12572

< 0,5 m

-

Reaction to fire

DIN 4102-1

class B1

Thermal conductivity (λ)

EN 12667

≤ 0,043 W/(m·K)

≤ 0.025 BTU/h∙ft∙°F

Temperature resistance

-

-30 / +90 °C

-22 / +194 °F

Application temperature

-

≥ +5 °C

≥ +41 °F

Storage temperature(1)

-

+1 / +20 °C

+33.8 / +68 °F

(1)Store the product in a dry, covered location for no more than 24 months. Waste classification (2014/955/EU): 17 02 03.

FIELDS OF APPLICATION

RELATED PRODUCTS

MARLIN

WINBAG

KOMPRI CLAMP

EVO VERSION The EVO version not only reduces waste and installation time because it has no separating layer, but also has a special film that keeps its shape without self-expanding as long as it is rolled up.

SAFE PACKAGING Supplied with a plastic core to prevent water and moisture absorption during construction, which could cause unwanted swelling.

ACOUSTIC AND SEALING | EXPAND BAND | 147


WINDOW BAND SELF-EXPANDING SEALING TAPE FOR WINDOWS/DOORS

D DIN 18542 BG 1

TRIPLE PROTECTION It seals the joints of doors and windows from air and heavy rain while maintaining the thermal-acoustic properties over the entire depth.

SELF-EXPANDING Seals cracks between 6 and 15 mm, adjusting to the surface, and also ensures air and water tightness, serving as a vapour control layer.

COMPOSITION elastic polyurethane foam with additives

CODES AND DIMENSIONS CODE

B

s

L

B

s

L

[mm]

[mm]

[m]

[in]

[mil]

[ft]

WINDOW54615

54

6

15

15

2.1

236

591

49

7

WINDOW74615

74

6

15

15

2.9

236

591

49

5

TECHNICAL DATA Properties

standard

value

USC conversion -

Classification

DIN 18542

BG 1(1)

Airtightness

EN 12114

α ≤ 1.0 m3/(h·m·(daPa)n

-

Tightness in heavy rain

EN 1027

≥ 600 Pa

-

Resistance to UV and weathering

DIN 18542

compliant with class BG 1

-

Compatibility with other building materials

DIN 18542

compliant with class BG 1

-

Water vapour resistance factor (μ)

EN ISO 12572

< 100

-

Vapour pressure gradient

-

externally permeable

-

Reaction to fire

DIN 4102-1

class B1

-

59 dB

-

Acoustic insulation of the joint Thermal conductivity (λ)

EN 12667

≤ 0,043 W/(m·K)

≤ 0.025 BTU/h∙ft∙°F

Temperature resistance

-

-30 / +90 °C

-22 / +194 °F

Application temperature

-

≥ +5 °C

≥ +41 °F

Storage temperature(2)

-

+1 / +20 °C

+33.8 / +68 °F

(1)BG 1: in accordance with DIN 18542, BG 1 tapes are suitable for outdoor use even when exposed to UV light and are watertight under a pressure of at least 600 Pa. (2)Store the product in a dry, covered location for no more than 24 months.

148 | WINDOW BAND | ACOUSTIC AND SEALING


FIELDS OF APPLICATION

RELATED PRODUCTS

MARLIN

WINBAG

KOMPRI CLAMP

FAST INSTALLATION The advantage of WINDOW BAND is that it saves a considerable amount of time during assembly. With just one product it is possible to seal the three layers without the need for other.

PERFORMING BG1 Compliant with EnEV and RAL requirements, also guarantees a high level of thermal and acoustic insulation.

ACOUSTIC AND SEALING | WINDOW BAND | 149


PLASTER BAND IN/OUT SPECIAL HIGH-ADHESION TAPE, CAN BE ALSO PLASTERED

EXCELLENT ADHESION Its excellent adhesion makes it ideal for application on most surfaces, even at low temperatures.

RESISTANT SEPARATION FILM Even when applied in tight spaces and corners, the PP liner can be removed without risk of failure.

CODES AND DIMENSIONS PLASTER BAND IN CODE PLASTIN1560 PLASTIN1585 PLASTIN15135 PLASTIN7520 2 PLASTIN10020 PLASTIN15020 1

liner

B

t

T

L

liner

B

L

[mm]

[mm]

[mm]

[mm]

[m]

[in]

[in]

[ft]

15 / 60 15 / 85 15 / 135 75 100 150

75 100 150 75 100 150

20 20 20

75 100 150 75 100 150

25 25 25 25 25 25

0.6 / 2.4 0.6 / 3.4 0.6 / 5.3 3.0 3.9 5.9

3.0 4.0 5.9 3.0 3.9 5.9

82 82 82 82 82 82

liner

B

t

T

L

liner

B

L

[mm]

[mm]

[mm]

[mm]

[m]

[in]

[in]

[ft]

15 / 60 15 / 88 15 / 135 15 / 185 75 100 150 200

75 100 150 200 75 100 150 200

20 20 20 20

75 100 150 200 75 100 150 200

25 25 25 25 25 25 25 25

0.6 / 2.4 0.6 / 3.4 0.6 / 5.3 0.6 / 7.3 3.0 3.9 5.9 7.9

3.0 4.0 5.9 7.9 3.0 3.9 5.9 7.9

82 82 82 82 82 82 82 82

5 4 2 5 4 2

PLASTER BAND OUT CODE PLASTOUT1560 PLASTOUT1585 1 PLASTOUT15135 PLASTOUT15185 PLASTOUT7520 T PLASTOUT10020 2 PLASTOUT15020 t PLASTOUT20020

T

T

t

tape glue

1

T

2

150 | PLASTER BAND IN/OUT | ACOUSTIC AND SEALING

T T

liner

5 4 2 2 5 4 2 2


FIELDS OF APPLICATION

RELATED PRODUCTS

WINDOW BAND

EXPAND BAND

HERMETIC FOAM

MANICA PLASTER

CAN BE PLASTERED Technical fabric ideal to be plastered after its application. The pre-cut liner allows for quick and easy installation and an high level of aesthetics due to the possibility of concealing the tape behind claddings or plaster.

EASY-RELEASE FILM The easy-release PP liner provides a quick and easy installation.

ACOUSTIC AND SEALING | PLASTER BAND IN/OUT | 151


PLASTER BAND IN

COMPOSITION support 2-layer PP vapour control membrane adhesive acrylic dispersion without solvents release liner easy-release PP film

COMPOSITION support 2-layer PP vapour control membrane adhesive acrylic dispersion without solvents release liner easy-release PP film

TECHNICAL DATA Properties

standard

value

USC conversion

Total thickness

DIN 53855

0,5 mm

20 mil

Mass per unit area

EN 1848-2

300 g/m2

113.9 oz/ft2

Water vapour transmission (Sd)

EN 1931

> 10 m

< 0.35 US perm

Tensile strength MD/CD

EN 12311-1

115 / 75 N/50 mm

13.13/8.57 lbf/in

Elongation MD/CD

EN 12311-1

75 / 80%

-

Watertightness

EN 13984

W1

-

Tightness in heavy rain

EN 1027

≥ 1050 Pa

-

Air permeability

EN 1026

≤ 0,1 m3/(h·m·(daPa)2/3

UV-resistant

-

3 months

-

Reaction to fire

EN 13501-1

class E

-

Application temperature

-

> +5 °C

> +41 °F

Temperature resistance

-

-40 / +80 °C

-40 / +176 °F

Storage temperature(1)

-

+5 / +25 °C

+41 / +77 °F

Solvents

-

no

-

Emicode

GEV test method

EC1 plus

-

(1)Store the product in a dry, covered location for no more than 24 months.

152 | PLASTER BAND IN/OUT | ACOUSTIC AND SEALING


PLASTER BAND OUT

COMPOSITION support breathable 2-layer PP membrane adhesive acrylic dispersion without solvents release liner easy-release PP film

COMPOSITION support breathable 2-layer PP membrane adhesive acrylic dispersion without solvents release liner easy-release PP film

TECHNICAL DATA Properties

standard

value

USC conversion

Total thickness

DIN 53855

0,7 mm

28 mil

Mass per unit area

EN 1848-2

360 g/m2

-

Water vapour transmission (Sd)

EN 1931

<1m

> 3.5 US perm

Tensile strength MD/CD

EN 12311-1

290 / 190 N/50 mm

-

Elongation MD/CD

EN 12311-1

75 / 135%

-

Watertightness

EN 13984

W1

-

Tightness in heavy rain

EN 1027

≥ 1050 Pa

-

Air permeability

EN 1026

≤ 0,1 m3/(h·m·(daPa)2/3

-

UV-resistant

-

12 months

-

Reaction to fire

EN 13501-1

class E

-

Application temperature

-

> -10 °C

> +14 °F

Temperature resistance

-

-40 / +80 °C

-40 / +176 °F

Storage temperature(1)

-

+5 / +25 °C

+41 / +77 °F

Solvents

-

no

-

Emicode

GEV test method

EC1 plus

-

(1)Store the product in a dry, covered location for no more than 24 months.

ACOUSTIC AND SEALING | PLASTER BAND IN/OUT | 153


PLASTER BAND IN | Recommendations for installation APPLICATION OF THE TAPE BEFORE INSTALLATION OF THE WINDOW/DOOR FRAME

1

2

3

4

5

6

7

154 | PLASTER BAND IN/OUT | ACOUSTIC AND SEALING


SEALING WITH WINDOW/DOOR ALREADY INSTALLED

1

2

3

4

5

6

7 ACOUSTIC AND SEALING | PLASTER BAND IN/OUT | 155


PLASTER BAND OUT | Recommendations for installation APPLICATION OF THE TAPE BEFORE INSTALLATION OF THE WINDOW/DOOR FRAME

1

2

3

4

5

6

7

156 | PLASTER BAND IN/OUT | ACOUSTIC AND SEALING


SEALING WITH WINDOW/DOOR ALREADY INSTALLED

1

2

3

4

5

6

7 ACOUSTIC AND SEALING | PLASTER BAND IN/OUT | 157


ASTM

SMART BAND

TESTED

UNIVERSAL SINGLE-SIDED TAPE WITH SEPARABLE LINER

SPECIAL LINER The product has a unique separating film which, thanks to a special treatment, can be divided at any point without pre-cutting, thus adapting to any installation requirement.

FLASHING TAPE It meets all the requirements to be classified as a tape for sealing external doors or windows, ensuring maximum safety even in case of stagnating water.

COMPOSITION support PE special film support UV-stabilised PE film glue acrylic dispersion without solvents release liner PP film with easy splitting

CODES AND DIMENSIONS CODE

SMART60 SMART75 SMART100 SMART150 SMART225 SMART300

B

L

B

L

[mm]

[m]

[in]

[ft]

60 75 100 150 225 300

25 25 25 25 25 25

2.4 3.0 3.9 5.9 8.9 11.8

82 82 82 82 82 82

TECHNICAL DATA Properties

standard

value

USC conversion

Thickness

-

0,24 mm

9.5 mil

Adhesion to OSB

ASTM D3330

≥ 5 N/10mm

≥ 2.86 lbf/in

Adhesion to steel

ASTM D3330

≥ 12 N/10mm

≥ 6.85 lbf/in

Adhesion to vinyl

ASTM D3330

≥ 5 N/10mm

≥ 2.86 lbf/in

Adhesion to plywood

ASTM D3330

≥ 5 N/10mm

≥ 2.86 lbf/in

Adhesion to its cladding material

ASTM D3330

≥ 10 N/10mm

≥ 5.71.86 lbf/in

Tensile strength

ASTM D 1000

3000 N/mm

17.13 lbf/mil

Elongation at failure

ASTM D 1000

≥ 400 %

-

Water vapour transmission (Sd)

-

> 18 m

< 0.19 US perm

UV-resistant

-

12 months

-

Tightness in heavy rain

-

conforming

-

Application temperature

-

-10 / +40°C

+14 / +104 °F

Temperature resistance

-

-30 / +80 °C

-22 / +176 °F

Storage temperature

-

+5 / +30 °C

+41 / +86 °F

In order to measure adhesion, it was necessary to avoid stretching by applying another tape to the support.

158 | SMART BAND | ACOUSTIC AND SEALING

10 8 6 4 2 2


FIELDS OF APPLICATION

PRODUCT RANGE

SMART60

SMART75

SMART100

SMART150

SMART225

SMART300

PUNCTURE RESISTANT The special composition of the support makes it particularly resistant to tearing and mechanical stress, thanks to its high deformability.

SMART The tape is unique and extremely versatile. Thanks to the easy-splitting liner, only a few sizes can be stored to meet any construction requirement.

ACOUSTIC AND SEALING | SMART BAND | 159


SMART BAND | Recommendations for installation WINDOW HOLE SEALING

1

2

3

4

5

6

7

8

160 | SMART BAND | ACOUSTIC AND SEALING

EASY SPLIT


9

10

11

12

13

14

15

16 ACOUSTIC AND SEALING | SMART BAND | 161


Rotho Blaas Srl does not guarantee the legal and/or design conformity of data and calculations, as Rotho Blass provides indicative tools such as technical-commercial service within the sales activity. Rotho Blaas Srl follows a policy of continuous development of its products, thereby reserving the right to modify their characteristics, technical specifications and other documentation without notice. The user or the designer are responsible to verify, at each use, the conformity of the data to the regulations in force and to the project. The ultimate responsibility for choosing the appropriate product for a specific application lies with the user/designer. The values resulting from "experimental investigations" are based on the actual test results and valid only for the test conditions specified. Rotho Blaas Srl does not guarantee and in no case can be held responsible for damages, losses and costs or other consequences, for any reason (warranty for defects, warranty for malfunction, product or legal responsibility, etc.) deriving from the use or inability to use the products for any purpose; from non-conforming use of the product; Rotho Blaas Srl is not liable in any way for any errors in printing and/or typing. In the event of differences between the contents of the catalogue versions in the various languages, the Italian text is binding and takes precedence with respect to the translations. Pictures are partially completed with accessories not included. Images are for illustration purposes only. Packaged quantities may vary. This catalogue is private property of Rotho Blaas Srl and may not be copied, reproduced or published, totally or in part, without prior written consent. All violations will be prosecuted according to law. The general purchase conditions of Rotho Blaas Srl are available on the website www.rothoblaas.com. All rights reserved. Copyright © 2022 by Rotho Blaas Srl All renderings © Rotho Blaas Srl


LEGEND A

[m2]

area

B

[mm]

base

H

L

[mm] [m] [mm] [m]

height

length

P

[mm]

depth

s

[mm]

thickness

Ø

[mm]

diameter

VOC

Volatile Organic Compounds

pieces / package

rolls for pallet

rolls for pallet

EPD

Environmental Product Declaration EPD LCA

Life Cycle Assessment LCA

reaction to fire B-s1,d0

gloves included in the box GLOVES INCLUDED

ASTM tested according to ASTM standards TESTED

classification GEV - EMICODE

classification according to French decree no. 2011-321


FASTENING AIRTIGHTNESS AND WATERPROOFING SOUNDPROOFING FALL PROTECTION TOOLS AND MACHINES

Via dell‘Adige N.2/1 | 39040, Cortaccia (BZ) | Italia Tel: +39 0471 81 84 00 | Fax: +39 0471 81 84 84 info@rothoblaas.com | www.rothoblaas.com

COD

Rotho Blaas Srl

01SOUND3EN

12|22

Rothoblaas is the multinational Italian company that has made innovative technology its mission, making its way to the forefront for timber buildings and construction safety in just a few years. Thanks to its comprehensive product range and the technically-prepared and widespread sales network, the company promotes the transfer of its knowhow to the customers and aims to be a prominent and reliable partner for developing and innovating products and building methods. All of this contributes to a new culture of sustainable construction, focused on increasing comfortable living and reducing CO2 emissions.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.