BEACON™ WIRE MESH RAILING SYSTEM PRODUCT DATA Perforated Metal Glass BEACON - AVAILABLE INFILLS Wire Mesh CableNet Laser Cut Panel Cable info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
2 BEACON™ WIRE MESH RAILING SYSTEM BEACON WIRE -11/11/22 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com Perforated Metal Glass BEACON - AVAILABLE INFILLS Wire Mesh CableNet Laser Cut Panel Cable Other mounting options available. Our BEACON Stainless Steel Railing System has a modern design with clean lines. This sleek system consists of single flat bar posts that are available in a range of striking metallic colors to accent your interior layout.
BEACON™
GLASS & METAL SYSTEM - TECHNICAL DATA
MATERIAL
Stainless Steel (304 or 316)
POST
Stainless Steel (201)
FINISH SIZE/SPACING
#6 Satin, #8 Mirror
ECM
Powder Coat
Glass with D-Clamps Clear, Tinted or Frit
2” Flat bar @ 5’-0” max. O.C. for glass infill, 4’-6” max. for perforated and wire mesh infill.
2”x2” End post, 2” flat bar intermediate post @ 4’-0” max. for cable infill.
Fascia, Top or Core mount.
Min. 3/8” laminated glass with PVB or SGP interlayer ¹ Glass standard thickness: 3/8”, 1/2”
Interlayer standard thickness, SGP: 0.035” , 0.06”
PVB: 0.035”
INFILL OPTIONS
Perforated Metal
Wire Mesh
Cable
CableNet
#6 Satin
1” wide frame
Ø3/16” cable
Ø1” frame, Ø1/16” (1.5mm) cable mesh
Powder Coat - Super Polyester (AAMA 2604) - $ 4
Laser Cut
Stainless Steel U-Cap
Stainless Steel U-Cap with LED 4
Stainless Steel Tube
TOP RAIL/HAND RAIL
Stainless Steel Tube with LED
Wood (Red Oak, Cherry or Maple) 3
ECM
not
Wood (Red Oak, Cherry or Maple) with LED
Powder Coat - PVDF (AAMA 2605) - $$ 4
1/4” thick aluminum panel.
#6 Satin, Powder Coat
#6 Satin
#6 Satin, Powder Coat Unstained #6 Satin
1. IBC 2015 & newer requires railing glass to be laminated. VIVA recommends SGP for exterior applications.
2. All LED LINEAR products are ETL certified; ETL mark is proof of product compliance to North American safety standard.
3. Other species available upon request.
4. $ to $$$: Indicates finish type comparative cost.
3
Ø1-1/2” with LED LINEAR, Ø1-1/2” or Ø2” with LED POD Ø2” with LED LINEAR 1” Height U-Cap with LED LINEAR for Glass Top Rail Ø1-1/2” or Ø2” for Hand Rail Ø2” or 2”x1” Rectangular tube for Top Rail 1” Height U-Cap for Glass Top Rail Ø2”
finish is
available for U-cap, top rail or hand rail.
info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
Wire Mesh Infill
TOP RAIL
HAND RAIL
TOP RAIL
WIRE MESH
HAND RAIL
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. R4"
FINISH FLOOR
STRINGER
WIRE MESH
4
PA03
PA02
PA01
1'-0"
4'-6" MAX 4'-6" MAX
1'-0"
VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I
2" NOM. 3" NOM.
2" NOM. GAP
LEVEL 1 0'-0"
3'-0" 3'-6" TOP RAIL OPTIONS Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE Ø1-1/2" iRAIL BEACON POST BEACON RAILING SYSTEM WM-10 1 5 16 " 7 16 " WM-15 WM-13 WM-17 WM-19 WM-20 WM-21 9 16 " TYP. 1" TYP. WM-11 WM-12 WM-14 7 16 11 16 1 2 13116 33 4 " 7 16 21 8 " 7 8 1 7 8 " 1 7 8 " 5 8 " 9 16 " 1 1 16 " 13 16 " 15 16 " 3 8 " AVAILABLE WIREMESH TYPES: SPIDER CLAMP Page 2.3 of 4 12/4/2023 WIRE MESH INFILL BEACON RAILING SYSTEM AVAILABLE WIRE MESH TYPES TOP RAIL OPTIONS info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
Perforated Metal Infill
AVAILABLE PERFORATED TYPES:
SPIDER CLAMP
PERFORATED METAL TOP RAIL
HAND RAIL
Ø2" TUBE
TOP RAIL
R4" 3" NOM.
Ø1-1/2" TUBE
NOM. GAP
HAND RAIL 2" NOM.
PERFORATED METAL
2"x1"
TOP RAIL OPTIONS
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
5
MAX
PA03 PA02 PA01 4'-6" MAX 4'-6"
1'-0" 1'-0"
BEACON POST
VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM
BEACON RAILING SYSTEM 2"
TUBE
iRAIL
Ø1-1/2"
STRINGER LEVEL 1 0'-0" FINISH FLOOR 3'-0" 3'-6"
9 16 " 1" 1 16 " (14 GA) SECTION VIEW
1" 13 4 " 5 16 " 1 8 " 9 16 " 11 16 " 3 8 " 5 8 7 16 13 16 " 7 8 " 1 1 16 " PMSL-0325 PMRO-0610 PMRO-1014 PMSQ-1013 PMRO-1217 PMSL-1122 Ø3 8 " Ø1 2 " Ø 1 4 " 3 8 " Page 2.2 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com BEACON RAILING SYSTEM
METAL INFILL VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
OPTIONS AVAILABLE PERFORATED TYPES
PERFORATED
TOP RAIL
BEACON RAILING SYSTEM
Glass Infill
GLASS OPTIONS:
D-CLAMP TYPE OPTIONS
CODE POST FITTING
BD-1 Stainless Steel, Satin Stainless Steel D-Clamp
BD-2 Stainless Steel, ECM ECM D-Clamp
BD-3 Powder Coated Stainless Steel, Satin D-Clamp
TOP RAIL
HAND RAIL
R4"
LEVEL 1 0'-0"
BEACON POST
LAMINATED GLASS
TOP RAIL
HAND RAIL
LAMINATED GLASS STRINGER
FINISH FLOOR
Ø2" TUBE
Ø1-1/2" TUBE
2"x1" TUBE
Ø1-1/2" iRAIL
TOP RAIL OPTIONS
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
6 G03 G02 G01 5'-0" MAX 5'-0" MAX
1'-0" 1'-0"
2" NOM.
Clear Monolithic Clear Laminated (PVB or SGP)
Colored Laminate (PVB only)
VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V A I
Bent Tinted Satin Etched Ceramic Frit
23 8 " NOM. GAP
3" NOM.
3'-0" 3'-6"
Page 2.1 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. AVAILABLE GLASS TYPES
BEACON RAILING SYSTEM GLASS INFILL
TOP RAIL OPTIONS
CONTINUOUS PANEL
TOP RAIL
HAND RAIL
CABLENET
DIMENSIONS ARE NOMINAL 1"
TOP RAIL
HAND RAIL
R4"
LEVEL 1 0'-0"
BEACON POST
FINISH FLOOR 3'-0"
STRINGER
7x7 CONSTRUCTION CABLE Ø1/16" [Ø1.5mm]
Ø2" TUBE
Ø1-1/2" TUBE
2"x1" TUBE
Ø1-1/2" iRAIL
TOP RAIL OPTIONS
TOP RAIL OPTIONS
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
7 CP10 CP11 CP11
CABLENET PANEL
CableNet Infill
1'-0" 1'-0"
CABLENET PANEL
VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V A 27 8 " NOM. GAP
MAX
MAX
2" NOM. 3" NOM.
5'-0"
5'-0"
3'-6"
41 8 " 2 3 8 60°
BEACON RAILING SYSTEM
FRAME
Page 2.5 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
BEACON RAILING SYSTEM
CABLENET INFILL
TOP RAIL
CABLE
HAND RAIL
HAND RAIL 3" MAX. 4" MAX.
BEACON POST
CABLE
LEVEL 1 0'-0"
TOP RAIL STRINGER
FINISH FLOOR 3'-0" 3'-6"
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
8 4'-0"
4'-0" MAX 1'-0" 1'-0"
MAX
Cable Infill
VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I
BEACON RAILING SYSTEM
R4"
3 1 4 " MAX. Stainless Steel 316 Cable Ø3/16", 1X19 Construction TOP RAIL OPTIONS Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE Ø1-1/2" iRAIL Page 2.4 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CABLE INFILL BEACON RAILING SYSTEM
RAIL OPTIONS
TOP
BEACON RAILING SYSTEM
Laser cut w/ spiders
TOP RAIL
HAND RAIL
5'-0" MAX 1'-0"
5'-0" MAX
TOP RAIL
ALUMINUM PANEL
HAND RAIL
BEACON POST
ALUMINUM PANEL
2" NOM. GAP
FINISH FLOOR
STRINGER
TOP RAIL OPTIONS
1'-0"
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
9
0'-0"
LEVEL 1
3'-0" 3'-6"
V V A TM
2" NOM. 3" NOM.
R4"
VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.1B OF 5 12/4/2023 Visit https://vivarailings.com/ for range of design patterns Or provide your custom pattern Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE Ø1-1/2" iRAIL info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. LASER CUT INFILL BEACON RAILING SYSTEM TOP RAIL OPTIONS
Mounting Condition, Top Mounted Post
Anchored to Concrete ¹ - $ ²
Detail# BE-T01 ³
Embed Plate (By others)
Cored into Concrete - $$
Detail# BE-T02
Welded @ Steel Channel - $
Detail# BE-T03
Welded @ Embed Plate - $
Detail# BE-T04
(1) Min. 4000 PSI concrete, Typ.
(2) $ to $$$: Indicates mounting type comparative cost
(3) Anchoring is not an available option for top mount with cable infill
(4) 6 1 2" Min. for end post with cable infil
Anchored to Concrete Slab on Deck - $$
Detail#
3/8" BENT PLATE (BY OTHERS)
Anchored to Concrete Welded to Steel Plate - $
Detail# BE-T06
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR
VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
10 6"
MIN.
3" MIN. 5" MIN. 6" MIN. 5" ⁴ MIN. 5" MIN. 5" MIN.
6" MIN. 3 1 4 " MIN. VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I BEACON RAILING SYSTEM
THE
VIVA
TO
SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS
VIVA
OF PRODUCTS
BY
NOT
BUILDING SYSTEMS TO WHICH
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED
PROPERLY
IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF
RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION
FURNISHED
25 8 " 6" MIN.
BE-T05 Page 3.1 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. BEACON RAILING SYSTEM MOUNTING CONDITION, TOP MOUNTED POST
(1)
(2)
Mounting Condition, Fascia Mounted Post 6"
Anchored to Concrete ¹ - $$$
Detail# BE-F01 ²
BEACON RAILING SYSTEM
Welded @ Steel Tube - $$
Detail# BE-F04
Welded @ Embed Plate - $$
Detail# BE-F02
Embed Plate (By others)
Welded @ Steel Channel - $$
Detail# BE-F03
Detail# BE-F05
3/8" THICK POUR STOP (BY OTHERS)
STUD or DEFORMED REBAR (BY OTHERS)
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT,
11 6" 6" 6"
MIN. 6" MIN. 6" VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V A
6" 6"
PLEASE CONTACT VIVA RAILINGS. 3" MIN.
@ Pour Stop - $$
Welded
MIN.
3"
Min. 4000 PSI concrete, Typ.
Anchoring is not a recommended option for cable infill Page 3.2 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. BEACON RAILING SYSTEM MOUNTING CONDITION, FASCIA MOUNTED POST
30°
22°
12 VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I BEACON RAILING SYSTEM Illuminated Railing Ø11 2 " 36 " TO FF TOP RAIL ILLUMINATED HANDRAIL 3 5 16 " 4 2 " TO FF Illuminated Handrail Option Illuminated Toprail Option See Viva iRail Railing System for more info iRAIL POD ORIENTATION OPTIONS 18" 24" OR 36" iRAIL POD SPACING OPTIONS POD iRAIL Linear
ASYM. LINEAR SYM. LINEAR iRAIL LINEAR ORIENTATION OPTIONS
ASYM. POD SYM. POD Page 4 of 4 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com BEACON RAILING SYSTEM iRAIL LIGHTED RAILING SYSTEM ILLUMINATED RAILING
13 FINISHING OPTIONS
SATIN / #8 MIRROR ECM POWDER COAT SS ECM PC POST BD-1 BD-2 BD-3 SKU D-Clamp SS D-Clamp ECM D-Clamp SS FITTING TYPE
Beacon D-Clamp (Finish SS + SS)
ECM
ECM)
PC
Mirror Finish comes at an additional cost to our #6
Available in Standard and Premium Colors Available in Satin Black, Brass, Gold & Copper. info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com BEACON WIRE MESH RAILING SYSTEM
#6
BD-1
BD-2 Beacon D-Clamp (Finish
+
BD-3 Beacon D-Clamp (Finish
+ SS) DESCRIPTION #8
Finish.
14 BEACON GLASS RAILING SYSTEM AMERICAN AIRLINES HEADQUARTERS General Contractor: StructureTone-Southwest Architect: Gensler AMERICAN AIRLINES HEADQUARTERS - FT. WORTH, TX info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
15 BEACON GLASS RAILING SYSTEM AMERICAN AIRLINES HEADQUARTERS General Contractor: StructureTone-Southwest Architect: Gensler AMERICAN AIRLINES HEADQUARTERS - FT. WORTH, TX info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 (Dallas/Fort Worth Metroplex) PH: 972.353.8482 | info@vivarailings.com vivarailings.com NORTH AMERICA OPERATIONS Dallas/Fort Worth, TX San Diego, CA Atlanta, GA Orlando, FL New York, NY Washington DC Regional Locations Version:120423 Kansas City, KS ICC-ES 4405 Certified SHOE™ Structural Glass Railing System The American Institute of Architects The California Contractors State License Board Certified Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing US Companies Eight Years in a Row 2012-2019 Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing Texas Companies #211 LEED Material & Resources Credits 4.1 and 4.2