www.fgks.org   »   [go: up one dir, main page]

Paneldek Product Technical Statement

Page 1

ROOFING SOLUTIONS

PRODUCT TECHNICAL STATEMENT

Profiled Metal Roofing and Cladding NOMINAL DIMENSIONS 406mm EFFECTIVE COVER

PANELDEK

PANELDEK

37mm

16mm 189mm

DESCRIPTION Paneldek is a clip fastened trough section or decking profile.

APPLICATIONS

FASTENERS

• Residential Roofing and Cladding • Canopies

Paneldek is fastened with a galvanised steel bracket, attached to each support member with two 10g x 45mm wafer head Timberfix screws, or two 10g x 25mm wafer head Steelfix screws to steel.

FEATURES

DURABILITY

Paneldek is a traditional trough section roofing profile. It features a unique hinge locking action that gives great stability to the side lap while protecting the outside edge from visual exposure and the weather.

All material selections must be compatible with prevailing environmental conditions and adjacent materials, see Roofing Solutions Product Guide or Specifiers Guide for details. Areas not exposed to rain washing will require programmed maintenance.

OPTIONS Clear sheeting is available in profiled G.R.P. (fibreglass) to match.

MATERIALS Available in metallic coated and pre-painted steel in .55mm B.M.T. (base metal thickness) aluminium plain and prepainted in .70mm, and other non-ferrous metals.

STRO296

WARRANTY PLUS Steel & Tube WarrantyPlus is the most comprehensive warranty available in the industry. WarrantyPlus covers an extended range of performance criteria, is supported back-to back by our suppliers, includes site-specific maintenance requirements and is transferable to subsequent owners.

JAN 2014

• Industrial/Commercial Roofing and Cladding

PRODUCT TECHNICAL STATEMENT

203mm


ROOFING SOLUTIONS

PERFORMANCE DATA MASS (KG/M2) .55mm B.M.T.

6.50

Controlled Traffic Internal

Heavy Traffic End

Internal

End

Gauge

Span

Load

Span

Load

Gauge

Span

Load

Span

Load

.55mm

2000

2.00 kPa

1400

2.00 kPa

.55mm

1500

2.47 kPa

1000

2.47 kPa

MINIMUM PITCH

IMPORTANT PUBLICATIONS

PANELDEK

In accordance with Acceptable Solution E2, the minimum pitch for Paneldek for roofing dwellings is 3˚. Roof runs in excess of 60 metres should be checked for water runoff capacity.

For your installation to perform to its potential, it is essential that it is designed, installed and maintained in accordance with good trade practice. Please refer to:

PRODUCT TECHNICAL STATEMENT

Loads are Ultimate Limit State loads in Kilopascals.

SPECIFICATIONS

• New Zealand Steel: Installation Guide

Recommended specifications are available in the branded sections of MasterSpec BASIC or MasterSpec STANDARD, or from your local Steel & Tube branch or visit our website.

DESIGN DETAILS

• Steel & Tube: Roofing Solutions Product Guide • New Zealand Steel: Builders and Specifiers Guide • BRANZ: Good Profiled Metal Roofing Practice • MRM: New Zealand Metal Roofing and Wall Cladding Code of Practice • E2/AS1

Design details covering many applications are available on our website in CAD and PDF under each product section. Visit www.steelandtube.co.nz.

INSTALLERS A list of local installers for your area and contract type is available from your local Steel & Tube branch or visit www.steelandtube.co.nz.

JAN 2014

Note: Trademarks apply to the following products presented in this publication: Paneldek, MasterSpec BASIC and MasterSpec STANDARD.

CALL US TODAY Technical helpline 0800 333 247 To purchase our products 0800 427 663

www.steelandtube.co.nz


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.