www.fgks.org   »   [go: up one dir, main page]

Phywe tess expert chemistry2012

Page 1

expert

TESS

s n o i t u l o s s s Worldcla : n o i t a c u d e r e t t e b r o f m o c . e w y h p . w ww

TESS

Global network Your partner is never far away! HEADQUARTERS/PRODUCTION GÖTTINGEN, GERMANY

expert

EASTERN EUROPE EUROPE

MIDDLE EAST

ASIA-PACIFIC

Tel. +49 (0) 551 604 - 0 Fax +49 (0) 551 604 - 107 info@phywe.com

More than 600 experiments

16504-42

Find more Laboratory Experiments in our special ­catalogues Physics, Biology, Engineering and Medicine.

excellence in science

AMERICAS

Our worldwide presence enables us to offer you customised local solutions. More than 145,000 customers in over 95 countries appreciate our experience and reliability, our high technical standards, and the ease and clarity with which our innovative products can be operated. Are you looking for a partner near your location? Please do not hesitate to call us. We would be pleased to assign you a personal contact.

Laboratory Experiments Chemistry

PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen

© Copyright by PHYWE Systeme GmbH & Co. KG. Subject to change without notice. Errors and omissions excepted. Edition 12/2012

AFRICA

Laboratory Experiments Chemistry School · University

excellence in science

HEADQUARTERS/PRODUCTION PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen Germany P. +49 (0) 551 604-0 F. +49 (0) 551 604-107 info@phywe.com

excellence in science

AMERICAS P. +49 (0) 551 604-119 F. +49 (0) 551 604-115 america@phywe.com

EASTERN EUROPE P. +49 (0) 551 604-233 F. +49 (0) 551 604-115 oe@phywe.com

AFRICA P. +49 (0) 551 604-323 F. +49 (0) 551 604-115 africa@phywe.com

MIDDLE EAST P. +49 (0) 551 604-222 F. +49 (0) 551 604-115 nmo@phywe.com

EUROPE P. +49 (0) 551 604-254 F. +49 (0) 551 604-115 we@phywe.com

ASIA-PACIFIC P. +49 (0) 551 604-245 F. +49 (0) 551 604-115 asia@phywe.com


Chemistry: Curricula Compliant Experiments – for your educational needs

Pharmacy: Curricula Compliant Experiments – multidisciplinary education with PHYWE

PHYWE experiments have been matched to the curricula of more than 30 selected universities worldwide. The interaction between PHYWE’s experiments and the supporting content of experimental lectures and lab course has led to the creation of a teaching package that is highly relevant to the taught curriculum worldwide.

Pharmacy is one of the most multidisciplinary subjects taught in natural sciences. The first semesters or introductory courses cover general topics in physics, biology and medicine. Pharmaceutical chemistry includes the classical main topics of chemistry: Inorganic, Organic, Analytical Chemistry, Spectroscopy and Biochemistry with reference to pharmaceutical topics.

Chemistry

Pharmacy

Bachelor of Science course - Reference Example

Bachelor of Science course - Reference Example

Preparatory Courses

Content Laboratory Experiments

Basics in ­General, ­Analytical, Organic and Inorganic ­Chemistry (Chapter 2)***

1. Sem.

2. Sem.

3. Sem.

General C­ hemistry (Chapter 3)

Analytical C­ hemistry (Chapter 4)

Inorganic Chemistry (Chapter 7)

5. Sem.

Organic Chemistry (Chapter 8)

Physical Chemistry (Chapter 6) Inorganic Chemistry (Chapter 7)

General Chemistry (Chapter 3)

Lecture, Tutorial, Experiments

4. Sem.

Organic Chemistry (Chapter 8)

6. Sem. Technical Chemistry (Chapter 9)

Content Laboratory Experiments

Lecture, Tutorial, Experiments

Spectroscopy (Chapter 5)

General Physics *

Physical Chemistry (Chapter 6) Elective S­ ubject

Microbiology **

Interdis. Subjekt

Electrochemistry (Chapter 6.6)

General Physics *

Theoretical Courses

Mathematics

e.g. Biotechnology, Material Chemistry (Chapter 10)

Molecular Analytics (NMR) and Spectroscopy (Chapter 5) Statistical Thermodynamics

Theoretical Courses

Bachelor Thesis

5. Sem.

6. Sem.

General Biology **

Organic Chemistry (Chapter 8)

Spectroscopy (Chapter 5)

Pharmacognosy Microscopy of ­medical plants **

Clinical Chemistry***

Human Physiology ***

Microbiology **

Inorganic Chemistry (Chapter 7)

Analytical Chemistry (Chapter 4)

Physical Chemistry: Gas Laws, Viscosity, Thermodynamics (Chapter 6)

Biochemistry (Chapter 10.1)

Chromatography (Chapter 4.3)

Histology ***

Mathematics

Human Physiology ***

Pharmacognosy

Pathophysiology

Pharmaceutical Engineering

Bachelor Thesis

PHYWE Experiments available in this catalogue

**

Please refer to TESS expert Biology catalogue

***

Also refer to TESS beginner/advanced brochure

*

Please refer to TESS expert Physics catalogue

**

Please refer to TESS expert Biology catalogue

The PHYWE service does not end with the delivery of the equipment. With our after sales service, we offer you comprehensive support:

e.g. Biotechnology (Chapter 10.2)

Immunology

Pharmacokinetics

Customer service before, during and after your purchase

Pharmaceutical Technology

More than 70% of the experimental courses are covered by PHYWE experiments!

PHYWE Experiments available in this catalogue Please refer to TESS expert Physics catalogue

4. Sem.

Bachelor Thesis

More than 80% of the experimental courses are covered by PHYWE experiments!

*

3. Sem.

Disposal, ­Environment ­Protection (Chapter 9.3)

Elective ­Subject

Theoretical Chemistry

Bachelor Thesis

2. Sem.

General Chemistry (Chapter 3)

Biochemistry (Chapter 10) Biochemistry (Chapter 10)

1. Sem.

Service

Service from A to Z – our service, your satisfaction

***

Individual Service for individual needs By choosing a PHYWE product you decide for a comprehensive service at the same time. We support you with our multi-level service concept. From planning through to installation and up to our extensive after sales service. Rely on our strengths: rugged and long-lasting products made in Germany, customized for your needs.

Please refer to TESS expert Medicine catalogue

Customized information

Installation and setting-up

Stockage service / instruction

Training courses at PHYWE or on-site

Technical service

Repair service

1st response within 24 hours P. +49 (0) 551 604-196 F. +49 (0) 551 604-106 service@phywe.de

TESS expert Laboratory Experiments Physics

TESS expert Laboratory Experiments Biology

excellence in science

TESS beginner / advanced brochure

TESS expert Laboratory Experiments Physics

TESS expert Laboratory Experiments Biology

TESS expert Laboratory Experiments Medicine

excellence in science


Chemistry: Curricula Compliant Experiments – for your educational needs

Pharmacy: Curricula Compliant Experiments – multidisciplinary education with PHYWE

PHYWE experiments have been matched to the curricula of more than 30 selected universities worldwide. The interaction between PHYWE’s experiments and the supporting content of experimental lectures and lab course has led to the creation of a teaching package that is highly relevant to the taught curriculum worldwide.

Pharmacy is one of the most multidisciplinary subjects taught in natural sciences. The first semesters or introductory courses cover general topics in physics, biology and medicine. Pharmaceutical chemistry includes the classical main topics of chemistry: Inorganic, Organic, Analytical Chemistry, Spectroscopy and Biochemistry with reference to pharmaceutical topics.

Chemistry

Pharmacy

Bachelor of Science course - Reference Example

Bachelor of Science course - Reference Example

Preparatory Courses

Content Laboratory Experiments

Basics in ­General, ­Analytical, Organic and Inorganic ­Chemistry (Chapter 2)***

1. Sem.

2. Sem.

3. Sem.

General C­ hemistry (Chapter 3)

Analytical C­ hemistry (Chapter 4)

Inorganic Chemistry (Chapter 7)

5. Sem.

Organic Chemistry (Chapter 8)

Physical Chemistry (Chapter 6) Inorganic Chemistry (Chapter 7)

General Chemistry (Chapter 3)

Lecture, Tutorial, Experiments

4. Sem.

Organic Chemistry (Chapter 8)

6. Sem. Technical Chemistry (Chapter 9)

Content Laboratory Experiments

Lecture, Tutorial, Experiments

Spectroscopy (Chapter 5)

General Physics *

Physical Chemistry (Chapter 6) Elective S­ ubject

Microbiology **

Interdis. Subjekt

Electrochemistry (Chapter 6.6)

General Physics *

Theoretical Courses

Mathematics

e.g. Biotechnology, Material Chemistry (Chapter 10)

Molecular Analytics (NMR) and Spectroscopy (Chapter 5) Statistical Thermodynamics

Theoretical Courses

Bachelor Thesis

5. Sem.

6. Sem.

General Biology **

Organic Chemistry (Chapter 8)

Spectroscopy (Chapter 5)

Pharmacognosy Microscopy of ­medical plants **

Clinical Chemistry***

Human Physiology ***

Microbiology **

Inorganic Chemistry (Chapter 7)

Analytical Chemistry (Chapter 4)

Physical Chemistry: Gas Laws, Viscosity, Thermodynamics (Chapter 6)

Biochemistry (Chapter 10.1)

Chromatography (Chapter 4.3)

Histology ***

Mathematics

Human Physiology ***

Pharmacognosy

Pathophysiology

Pharmaceutical Engineering

Bachelor Thesis

PHYWE Experiments available in this catalogue

**

Please refer to TESS expert Biology catalogue

***

Also refer to TESS beginner/advanced brochure

*

Please refer to TESS expert Physics catalogue

**

Please refer to TESS expert Biology catalogue

The PHYWE service does not end with the delivery of the equipment. With our after sales service, we offer you comprehensive support:

e.g. Biotechnology (Chapter 10.2)

Immunology

Pharmacokinetics

Customer service before, during and after your purchase

Pharmaceutical Technology

More than 70% of the experimental courses are covered by PHYWE experiments!

PHYWE Experiments available in this catalogue Please refer to TESS expert Physics catalogue

4. Sem.

Bachelor Thesis

More than 80% of the experimental courses are covered by PHYWE experiments!

*

3. Sem.

Disposal, ­Environment ­Protection (Chapter 9.3)

Elective ­Subject

Theoretical Chemistry

Bachelor Thesis

2. Sem.

General Chemistry (Chapter 3)

Biochemistry (Chapter 10) Biochemistry (Chapter 10)

1. Sem.

Service

Service from A to Z – our service, your satisfaction

***

Individual Service for individual needs By choosing a PHYWE product you decide for a comprehensive service at the same time. We support you with our multi-level service concept. From planning through to installation and up to our extensive after sales service. Rely on our strengths: rugged and long-lasting products made in Germany, customized for your needs.

Please refer to TESS expert Medicine catalogue

Customized information

Installation and setting-up

Stockage service / instruction

Training courses at PHYWE or on-site

Technical service

Repair service

1st response within 24 hours P. +49 (0) 551 604-196 F. +49 (0) 551 604-106 service@phywe.de

TESS expert Laboratory Experiments Physics

TESS expert Laboratory Experiments Biology

excellence in science

TESS beginner / advanced brochure

TESS expert Laboratory Experiments Physics

TESS expert Laboratory Experiments Biology

TESS expert Laboratory Experiments Medicine

excellence in science


expert

TESS

s n o i t u l o s s s Worldcla : n o i t a c u d e r e t t e b r o f m o c . e w y h p . w ww

TESS

Global network Your partner is never far away! HEADQUARTERS/PRODUCTION GÖTTINGEN, GERMANY

expert

EASTERN EUROPE EUROPE

MIDDLE EAST

ASIA-PACIFIC

Tel. +49 (0) 551 604 - 0 Fax +49 (0) 551 604 - 107 info@phywe.com

More than 600 experiments

16504-42

Find more Laboratory Experiments in our special ­catalogues Physics, Biology, Engineering and Medicine.

excellence in science

AMERICAS

Our worldwide presence enables us to offer you customised local solutions. More than 145,000 customers in over 95 countries appreciate our experience and reliability, our high technical standards, and the ease and clarity with which our innovative products can be operated. Are you looking for a partner near your location? Please do not hesitate to call us. We would be pleased to assign you a personal contact.

Laboratory Experiments Chemistry

PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen

© Copyright by PHYWE Systeme GmbH & Co. KG. Subject to change without notice. Errors and omissions excepted. Edition 12/2012

AFRICA

Laboratory Experiments Chemistry School · University

excellence in science

HEADQUARTERS/PRODUCTION PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen Germany P. +49 (0) 551 604-0 F. +49 (0) 551 604-107 info@phywe.com

excellence in science

AMERICAS P. +49 (0) 551 604-119 F. +49 (0) 551 604-115 america@phywe.com

EASTERN EUROPE P. +49 (0) 551 604-233 F. +49 (0) 551 604-115 oe@phywe.com

AFRICA P. +49 (0) 551 604-323 F. +49 (0) 551 604-115 africa@phywe.com

MIDDLE EAST P. +49 (0) 551 604-222 F. +49 (0) 551 604-115 nmo@phywe.com

EUROPE P. +49 (0) 551 604-254 F. +49 (0) 551 604-115 we@phywe.com

ASIA-PACIFIC P. +49 (0) 551 604-245 F. +49 (0) 551 604-115 asia@phywe.com


TESS expert Chemistry

TESS expert Chemistry 1

Table of Contents

2

2

Preparatory Course

11

3

General Chemistry

15

4

Analytical Chemistry

45

5

Spectroscopy

55

6

Physical Chemistry

67

7

Inorganic Chemistry

133

8

Organic Chemistry

153

9

Industrial Chemistry

167

10

Biochemistry and Biotechnology

183

11

About PHYWE

195

12

Indices

209

PHYWE Systeme GmbH & Co. KG · www.phywe.com 1


1 Table of Contents

excellence in science 2


Table of Contents

2 Preparatory Course

P3121260 Titration of a polyvalent acid with a strong base (with Cobra4)

27

P3121360 Titration of a weak organic acid with sodium hydroxide (with Cobra4)

27

2.2 General Chemistry

27

15300-88

TESS advanced Chemistry set General Chemistry

13

P3121460 Titration of a weak base (ammonia) with a strong acid (with Cobra4)

13300-10

TESS advanced General Chemistry, consumables and chemicals for 10 groups

13

3.4 Solutions and Mixtures

TESS advanced General Chemistry, necessary accessories for 1 group

13

P3030501 Solubility diagram of two partially miscible liquids

28

13431-88

P3030601 Miscibility gap in a ternary system

29

2.3 Inorganic Chemistry

P4100760 The origin of acid rain (with Cobra4)

30

15301-88

TESS advanced Chemistry set Inorganic Chemistry

14

31

13301-10

TESS advanced Inorganic Chemistry, consumables and chemicals for 10 groups

14

P3061062 Concentration cells without transport: Determination of the solubility products of silver halides (with Cobra4)

32

13433-88

TESS advanced Inorganic Chemistry, necessary Accessories for 1 group

14

P1135700 Osmosis - dependence of the osmotic pressure on the concentration P3030862 Solubility product (with Cobra4)

33

P3030960 Dissociation equilibrium (with Cobra4)

34

P3031101 Dissociation constants

35

P3021001 Boiling point elevation

36

P3021101 Freezing point depression

36

3 General Chemistry 3.1 Equilibria

3.5 Redox Reactions

P3031001 Complex formation equilibrium / complex formation constant

16

P3110600 Redox reactions between metals and metal oxides (thermite process)

37

P3030960 Dissociation equilibrium (with Cobra4)

17 18

P3100300 Reduction - reducing agents - redox process

38

P3030862 Solubility product (with Cobra4) P3030701 Distribution equilibrium

18

P3100400 Reduction of lead oxide

39

P3031101 Dissociation constants

18

P3110400 Sulphur trioxide - the sulphuric acid contact process

40

3.2 Molar Mass P3010401 Determination of molar mass using the ideal gas law

19

P3110500 Preparation of iron from oxidic ores (blast furnace process)

40

P3010501 Determination of the molecular mass of a liquid

20

P3121060 Volumetric redox titration: Cerimetry (with Cobra4)

40

P3021900 Determination of molar masses via a measurement of the boiling point elevation (ebullioscopy)

21

P3022000 Determination of molar masses via a measurement of the freezing point depression (cryoscopy)

22

P1309400 Determination of the molar masses of metals

3.6 Stoichiometry P3110900 The empirical formula of methane, ethane and propane

41

P3111000 Avogadro's law

42

P3121660 Briggs-Rauscher Reaction (with Cobra4)

43

23

P1309400 Determination of the molar masses of metals

44

P3061660 Titration curves and buffering capacity (with Cobra4)

24

4 Analytical Chemistry

P3020811 Determination of the enthalpy of neutralisation (with Cobra3)

25

4.1 Titration

P3020860 Determination of the enthalpy of neutralisation (with Cobra4)

25

P3060760 Conductivity titration (with Cobra4)

46 47

P1310100 Chemical fountain

26

P3061760 Potentiometric pH titration (phosphoric acid in soft drinks) (with Cobra4)

3.3 Acids and Bases

PHYWE Systeme GmbH & Co. KG · www.phywe.com 3


Table of Contents

P3121060 Volumetric redox titration: Cerimetry (with Cobra4)

48

P3061460 Precipitation titration (with Cobra4)

49

P3061660 Titration curves and buffering capacity (with Cobra4)

50

4.2 Electrogravimetry P3062201 Electrogravimetric determination of copper

51

4.3 Chromatography

6.1 Gas Laws P3011160 Gay-Lussac's law (with Cobra4)

70

P3011260 Amontons' law (with Cobra4)

71

P3011360 Boyle's law (with Cobra4)

72

P3031401 Law of integer ratio of volumes according to Gay-Lussac's law of chemical volumes

73

P3120400 Chromatographic separation processes: thin layer chromatography

52

P2320400 Thermal equation of state and critical point

73

P3031760 Chromatographic separation processes: Gas chromatography (with Cobra4)

53

01196-12

74

P3120300 Column chromatography - separation of leaf pigments

54

Handbook Glass Jacket System

6.2 Kinetic Theory P2320300 Maxwellian velocity distribution

75

P3010301 Diffusion in gases: The diffusion coefficient of bromine in air

76

6.3 Viscosity

5 Spectroscopy 5.1 X-ray Fluorescence Analysis

P2140300 Viscosity of Newtonian and non-Newtonian liquids (rotary viscometer)

77

P2544701 Qualitative X-ray fluorescence analysis of powder samples

56

P2140400 Viscosity measurement with the falling ball viscometer

78

P2545001 Quantitative X-ray fluorescence analysis of alloyed materials

57

P3010601 Determining the molecular weight of a polymer from intrinsic viscosity measurements

79

P2545101 Quantitative X-ray fluorescence analysis of solutions

58

6.4 Thermochemistry / Calorimetry

P2544501 Qualitative X-ray fluorescence spectroscopy of metals - Moseley's law

58

P3020260 Adiabatic coefficient of gases - Flammersfeld oscillator

80

P2544601 Qualitative X-ray fluorescence analysis of alloyed materials

58

P2320201 Heat capacity of gases

81

P3020411 Determination of the enthalpy of vaporisation of liquids (with Cobra3)

82

59

P3020460 Determination of the enthalpy of vaporisation of liquids (with Cobra4)

82

P5942100 Fundamental principles of Nuclear Magnetic Resonance (NMR)

62

P3020501 Partial molar volumes

83

P5942200 Relaxation times in Nuclear Magnetic Resonance

63

P3020611 Determination of the mixing enthalpy of binary fluid mixtures (with Cobra3)

84

P2511205 Model experiment NMR / ESR

64

P3020660 Determination of the mixing enthalpy of binary fluid mixtures (with Cobra4)

84

P3020711 Determination of the hydration enthalpy of an electrolyte (solution enthalpy) (with Cobra3)

85

P3020811 Determination of the enthalpy of neutralisation (with Cobra3)

85

P3020760 Determination of the hydration enthalpy of an electrolyte (solution enthalpy) (with Cobra4)

85

P3020911 Determination of the melting enthalpy of a pure substance (with Cobra3)

86

P3020960 Determination of the melting enthalpy of a pure substance (with Cobra4)

86

5.2 Nuclear Magnetic Resonance 09500-99

Compact MRT

5.3 Photometry and Photochemistry 35610-88

Measurespec spectrometer with cuvette holder and light source

65

P3070101 Absorption of light (UV-VIS spectroscopy)

66

P3070301 Excitation of molecules

66

P3070401 Absorption spectra and pKa values of pmethoxyphenol

66

excellence in science 4

6 Physical Chemistry


Table of Contents

P3021401 Determination of the enthalpy of combustion with a calorimetric bomb

87

P2411100 Characteristic curve and efficiency of a 114 PEM fuel cell and a PEM electrolyser

P3021501 Determination of the heat of formation of water

88

P3062201 Electrogravimetric determination of cop- 115 per

P3021601 Determination of the heat of formation for CO2 and CO (Hess' law)

89

P1268360 Voltage of a concentration cell (with Co- 116 bra4)

P3021701 Determination of the heating value of fuel oil and of the calorific value of olive oil

90

P1282360 Electrochemical series of metals (with 116 Cobra4)

P2310100 Thermal expansion in solids and liquids

91

P3040801 Adsorption isotherms

92

6.5 Chemical Kinetics

6.7 Phase Equilibrium P3021001 Boiling point elevation

117

P3021101 Freezing point depression

118

P3030401 Boiling point diagram of a binary mix- 119 ture

P3050101 Saponification rate of tert-butyl chloride

93

P3051101 Dependence of the reaction velocity on the temperature (acetic acid - magnesium)

94

P3050201 Reaction rate and activation energy of the acid hydrolysis of ethyl acetate

95

P3031360 Melting diagram of a binary mixture 121 (with Cobra4 )

P3050301 Kinetics of the inversion of saccharose

96

P3011400 Condensation of gases through an in- 122 crease of pressure and through cooling

P3050760 Halogen exchange rate (with Cobra4)

97

P3031900 Sublimation and solubility of iodine

123

P3050860 Conductometric measurement of the saponification of esters (with Cobra4)

98

P3031251 Steam distillation

124

P3121660 Briggs-Rauscher Reaction (with Cobra4)

99

P3031501 Rectification - the number of theoretical 124 trays in a distillation column

P4120360 Determination of the Michaelis constant 100 (with Cobra4)

P3031640 Fractional distillation with the bubble 124 tray column (with Cobra3)

P4120560 Enzyme inhibition (poisoning of en- 100 zymes) (with Cobra4)

6.8 Atomic Structures and Properties

6.6 Electro Chemistry

P1273460 Heat of fusion of sodium thiosulphate 120 (with Cobra4)

P2510315 Franck-Hertz experiment with a Ne-tube 125 P2510311 Franck-Hertz experiment with a Hg-tube 125

P3060111 Charge transport in solids (with Cobra3)

101

P3060160 Charge transport in solids (with Cobra4)

101

P3060260 Charge transport in liquids (with Cobra4) 102

P2510600 Fine structure: One and two electron 126 spectra

P3060301 Ion migration velocity

103

P2510700 Balmer series/ determination of Ry- 127 dberg's constant

P3060401 Transference numbers

104

P2510200 Specific charge of the electron e/m

128

P3060560 Temperature dependence of conductivity 105 (with Cobra4)

P2511006 Zeeman effect with a variable magnetic 129 system

P3060660 Conductivity of strong and weak electro- 106 lytes (with Cobra4)

P2511111 Stern-Gerlach experiment with a step 130 motor and interface

P3060862 Determination of the activity coefficient 107 by a conductivity measurement (with Cobra4)

P5942100 Basic principles in Nuclear Magnetic Res- 131 onance (NMR)

P3060962 Nernst equation (with Cobra4)

108

P3061101 Determination of diffusion potentials

109

P3061262 Temperature dependence of the electro- 110 motive force (with Cobra4) P3061562 pH measurement (with Cobra4)

7 Inorganic Chemistry

111

P3061811 Electrode kinetics: The hydrogen overpo- 112 tential of metals (with Cobra3) P3061860 Electrode kinetics: The hydrogen overpo- 112 tential of metals (with Cobra4) P3062101 Determination of Faraday's constant

P2210300 Dispersion and resolving power of a 132 prism and a grating spectroscope

113

7.1 Chemistry of Metals P3110600 Redox reactions between metals and 134 metal oxides (thermite process) P1310500 Molten-salt electrolysis

135

P1025200 Oxidation of metals

135

PHYWE Systeme GmbH & Co. KG · www.phywe.com 5


Table of Contents

P3100100 Effects of acids on metals

135

P3100400 Reduction of lead oxide

136

P1026800 Reduction of silver oxide

136

P1026900 Reduction of copper oxide

136

7.2 Coordination Chemistry P3031001 Complex formation equilibrium / com- 137 plex formation constant

7.3 Organometallic Chemistry P3101000 Haloalkanes: Grignard reagent

09700-99

Compact-Atomic Force Microscope (AFM)

151

7.5 Literature 01200-02

Handbook Physics X-Ray Experiments

152

8 Organic Chemistry 138

P3101100 Haloalkanes: Wurtz reaction - lithium 139 organyls

8.1 Organic Synthesis

7.4 Solid-state Chemistry and Cristallography

P3101100 Haloalkanes: Wurtz reaction - lithium 154 organyls

P2541301 Examination of the structure of NaCl 143 monocrystals with different orientations

P3101300 Toluene: Bromination in the nucleus

155

P2541401 X-ray investigation of cubic crystal struc- 144 tures / Debye- Scherrer powder method

P3101400 Aldehydes - reactions with ammonia

156

P3101500 Preparation of p-toluenesulfonic acid

157

P2541501 X-ray investigation of hexagonal crystal 144 structures / Debye-Scherrer powder method P2541602 X-ray investigation of crystal structures 145 / Laue method with digital X-ray image sensor (XRIS) P2541601 X-ray investigation of crystal structures / 145 Laue method P2542101 Debye-Scherrer diffraction patterns of 146 powder samples with three cubic Bravais lattices (Bragg-Brentano-geometry)

P3101600 Cannizzaro reaction and reaction of ben- 158 zaldehyde with ethylene glycol P3101000 Haloalkanes: Grignard reagent

159

P3120500 Electrophilic addition of bromine to 159 acetylene (ethyne)

8.2 Distillation, Purification P3031501 Rectification - the number of theoretical 160 trays in a distillation column P3031640 Fractional distillation with the bubble 160 tray column (with Cobra3)

P2542201 Debye-Scherrer diffractions pattern of 146 powder samples with a diamond structure (according to Bragg-Brentano)

P3031251 Steam distillation

P2542301 Debye-Scherrer diffraction patterns of 146 powder samples with a hexagonal lattice structure

P3120100 Separation of mixtures of liquids and of 163 solutions by extraction, stirring, centrifugation

P2542401 Debye-Scherrer diffraction patterns of 146 powder samples with a tetragonal lattice structure

P3120200 Quantitative determination of fat / Soxh- 164 let extraction

P2542501 Debye-Scherrer diffraction patterns with 146 a cubic powder sample P2542201 Debye-Scherrer diffractions pattern of 147 powder samples with a diamond structure (according to Bragg-Brentano) P2532000 Atomic Resolution of the graphite sur- 148 face by STM (Scanning Tunneling Microscope)

P3120400 Chromatographic separation processes: 165 Thin layer chromatography P3031760 Chromatographic separation processes: 165 Gas chromatography (with Cobra4) P3120300 Column chromatography - separation of 165 leaf pigments 01837-02

TESS Chemistry manual Organic Chemistry 166

Compact-Scanning Tunneling Microscope 149 (STM)

9 Industrial Chemistry

09613-00

Set samples nanomorphology, for Com- 149 pact Scanning Tunneling Microscope (STM)

9.1 Gases

excellence in science

161

P1308962 Distillation - determination of the alco- 162 hol content of wine (with Cobra4)

09600-99

P2538000 Basic methods in imaging of micro and 150 nanostructures with atomic force microscopy (AFM)

6

P2538400 Imaging of biological and medical micro 150 and nanostructure with atomic force microscopy (AFM)

P3110100 Obtaining nitrogen oxides by burning air 168 P3110200 Ammonia preparation from the elements 169 (Haber-Bosch process)


Table of Contents

P3110300 Combustion of ammonia to produce ni- 170 trogen dioxide - Ostwald process P3110400 Sulphur trioxide - the sulphuric acid 171 contact process

9.2 Salts

P1313762 Microbial synthesis of ethanol by Zy- 189 momonas mobilis subsp. mobilis (with Cobra4) P1313862 Production of amino acids by ferment- 190 ation of Corynebacterium glutamicum (with Cobra4)

P3110700 Salts of sulphuric acid - sulphates

172

P1310500 Molten-salt electrolysis

173

P1313962 Bacteria and mining - microbial extrac- 191 tion of ore by Thiobacillus ferrooxidians and thiooxidans (with Cobra4)

P1310000 Model experiment on the desulphurisa- 174 tion of flue gas

P1314000 Immobilised cells in the service of bio- 192 technology - microbial synthesis of acetic acid with Acetobacter aceti

P1309200 Electrostatic flue gas cleaning

10.3 Literature

9.3 Disposal, Environment Protection

175

9.4 Petrochemistry

01855-02

P3031640 Fractional distillation with the bubble 176 tray column (with Cobra3)

Complete Experiments technology

01331-02

Demo advanced Biology Manual Cobra4 194 Biochemistry & plant physiology

P3031660 Fractional distillation with the bubble 176 tray column (with Cobra4)

Chemistry/Bio- 193

P3031501 Rectification - the number of theoretical 177 trays in a distillation column P3110800 Cracking of hydrocarbons

178

P3021701 Determination of the heating value of 179 fuel oil and of the calorific value of olive oil

9.5 Metallurgy P5510100 Metallographic sample preparation - 180 grinding and polishing P5510200 Metallographic sample preparation - 181 chemical etching P3110500 Preparation of iron from oxidic ores 182 (blast furnace process) P3110600 Redox reactions between metals and 182 metal oxides (thermite process)

10 Biochemistry and Biotechnology 10.1 Biochemistry P4120160 Determination of the isoelectric point of 184 an amino acid (glycine) (with Cobra4) P4120360 Determination of the Michaelis constant 185 (with Cobra4) P4120460 Substrate inhibition of enzymes (with 186 Cobra4) P4120560 Enzyme inhibition (poisoning of en- 187 zymes) (with Cobra4) P4120660 The enzymatic activity of catalase (with 187 Cobra4)

10.2 Biotechnology P1313600 Fermentation of molasse to ethanol with 188 yeast

PHYWE Systeme GmbH & Co. KG · www.phywe.com 7


1 Table of Contents 1.2 How to use

excellence in science 8


1 Table of Contents 1.2 How to use

PHYWE Systeme GmbH & Co. KG · www.phywe.com 9


1 Table of Contents 1.3 Cooperations

excellence in science 10


2 Preparatory Course

Preparatory Course 2.1 2.2 2.3

Overview General Chemistry Inorganic Chemistry

12 13 14

PHYWE Systeme GmbH & Co. KG · www.phywe.com 11


2 Preparatory Course 2.1 Overview

excellence in science 12


2 Preparatory Course 2.2 General Chemistry

TESS advanced Chemistry set General Chemistry

15300-88

Sublimation of benzoic acid.

Function and Applications Set for the realization of 25 student experiments on the topics: ▪ ▪ ▪ ▪ ▪ ▪ ▪

Properties of materials (5 experiments) Mixtures (2 experiments) Separation of mixtures (4 experiments) Chemical reactions (2 experiments) Test reactions (3 experiments) Particle model (4 experiments) Chemical bonds (5 experiments)

Benefits ▪ Complete device set for an easy realization of the experiments ▪ Stable storage system: easy to store (stackable), fast control on completeness (foam inserts) ▪ The use of the software minimizes preparation time and facilitates individual learning speeds

- The detection of nitrogen 6. Particle model - Degradation of water by reducing agents - Dissolution processes in liquids - Dissolution of salts; Crystallisation 7. Chemical bonds - Test confirming the migration of ions by means of indicator paper - Periodic system; Dipolar properties - Melting point lowering/ boiling point elevation - Behaviour of salts with regard to solvents of different polarities

Additionally required material TESS advanced General Chemistry, consumables and chemicals for 10 groups

List of topics, General Chemistry 1. Properties of matter - Hardness, colour, magnetisability, water solubility - Combustibility, melting point - Boiling point; Sublimation; Density determination 2. Mixtures and mixture separation - Properties of mixtures; Liquid mixtures 3. Mixture separation - Evaporation; Filtration, magnetic separation - Extraction; Chromatography 4. Chemical reactions - Comparison of a physical process and a chemical reaction - Reaction of copper and sulphur 5. Test reactions - The detection of oxygen; The detection of hydrogen;

13300-10 TESS advanced General Chemistry, necessary accessories for 1 group 13431-88

PHYWE Systeme GmbH & Co. KG · www.phywe.com 13


2 Preparatory Course 2.3 Inorganic Chemistry

15301-88

TESS advanced Chemistry set Inorganic Chemistry

Properties of oxygen.

Function and Applications Set for the realization of 34 student experiments on the topics: ▪ Metals (3 experiments); Air and other gases (12 experiments) ▪ Water - components of water and water purification (11 experiments) ▪ Building material (3 experiments); Fertilizer (4 experiments) ▪ Glas manufacture (1 experiment) Benefits ▪ Complete device set for an easy realization of the experiments ▪ Stable storage system: easy to store (stackable), fast control on completeness (foam inserts) ▪ Interactive executing of the experiments with help of interTESS, a software to the PC supported experimentation and evaluation ▪ The use of the software minimizes preparation time and facilitates individual learning-speeds

List of topics Inorganic Chemistry 1. Metals - Oxidation of metals; Factors determining the reaction behaviour of metals; Oxygen, causative agent of oxidation 2. Air and other gases - The importance of air for combustion processes - Air, a mixture; Properties of oxygen - Reaction in pure oxygen; Quantitative investigation of oxides - Nitrogen, preparation and properties - Carbon dioxide, preparation and properties; Model of a fire extinguisher - Construction and function of a Bunsen burner - The candle's flame; Rusting - “slow combustion”; Reduction of copper oxide 3. Water – components of water and water purification

excellence in science 14

- Water content of natural substances; Dissolved components in different waters - Solubility of gases in water; Solutions, colloids, suspensions - Solubility of salts in water - comparison with the solubility of gases in water - Mode of operation of an aeration tank (sewage treatment plant) - Water treatment in sewage treatment plants - Hardness of water; Test for water; Water, an oxide - Degradation of water by reducing agents; Synthesis of water 4. Building material - Production of cement; Processing of gypsum - Gypsum moulds 5. Fertilizer - Mineral constituents of plants - Absorption of mineral substances by plants - Ammonia fertilizer; Burnt lime serving as a fertilizer 6. Glass manufacture - Soda-lime glass beads

Additionally required material TESS advanced Inorganic Chemistry, consumables and chemicals for 10 groups 13301-10 TESS advanced Inorganic Chemistry, necessary Accessories for 1 group 13433-88


3 General Chemistry

General Chemistry 3.1 3.2 3.3 3.4 3.5 3.6

Equilibria Molar Mass Acids and Bases Solutions and Mixtures Redox Reactions Stoichiometry

16 19 24 28 37 41

PHYWE Systeme GmbH & Co. KG · www.phywe.com 15


3 General Chemistry 3.1 Equilibria

P3031001

Complex formation equilibrium / complex formation constant

Determination of the number of ligands bound in the complex.

Principle Many metals, in particular transition elements, can form complexes with charged or neutral ligands. Complex formation reactions are equilibrium reactions. The stability of these complexes is described by the complex formation constant.

Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

Task Determine the number of ligands of the silver amine complex with a precipitation titration from a silver salt solution. What you can learn about ▪ Complex formation ▪ Chemical equilibrium ▪ Equilibrium constant Function and Applications

Main articles Magnetic stirrer Mini / MST Silver nitrate, cryst. 15 g Retort stand, h = 750 mm Burette, lateral stopcock, Schellbach, 25 ml, graduations 0.05 ml Burette clamp, roller mount., 2 pl. Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

47334-93 30222-00 37694-00

1 1 1

36506-01 37720-00

1 1

49224-88

1

The balances of the Sartorius CPA series convince already at first sight through an attractive, high-quality design - of the display up to the weighing pan. Onto the second look the "inner values" impress and that amazing price/power ratio. The "mechanical heart" of these balances is the patented monolithic weighing system which guarantees for confident and extremely precise weighingresults and beats in all models of the Sartorius CPA series. That ensures extremely precise weighing-results to your lab at shortest measuring times. Premium balances is also at Sartorius in any case: very best product quality with lasting reliability. 49224-88

excellence in science 16


3 General Chemistry 3.1 Equilibria

Dissociation equilibrium (with Cobra4)

P3030960

Neutralisation curve of formic acid.

Principle Carboxylic acids are potential electrolytes which exist in a weakly dissociated condition in aqueous solutions. The location of the dissociation equilibrium is quantitatively described by the Ka or pKa value which can be determined with potentiometric measurements.

Software Cobra4 - multi-user licence Immersion probe NiCr-Ni, teflon, 300 °C Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

14550-61 13615-05

1 1

49224-88

1

Cobra4 Sensor-Unit Drop Counter

Tasks 1. Measure the alteration of the pH value during a titration of approximately 0.1 molar aqueous solutions of formic acid, acetic acid, monochloroacetic acid, propionic acid, butyric acid and lactic acid with a 0.1 molar sodium hydroxide solution at constant temperature using Cobra4 system. 2. From the neutralisation curves read the pKa values of the acids and compare them. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪

True and potential electrolytes Strong and weak acids Law of mass action Henderson-Hasselbalch equation Dissociation constant and pKa value Substituent effects Potentiometry

Function and Applications The Cobra4 Drop Counter serves to count the number of drops that fall from a burette and so, indirectly, to quantitatively determine the volume of a liquid that flows from the burette.

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter

12600-00 12601-00

1 2

12630-00 12636-00

1 1

The Cobra4 Sensor-Unit Drop Counter can be connected to one of the following devices to transfer the measured data: Cobra4 Wireless-Link, Cobra4 Mobile-Link, Cobra4 USB-Link or Cobra4 Junior-Link. 12636-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 17


3 General Chemistry 3.1 Equilibria

Solubility product (with Cobra4)

P3030862 Principle The solubility of poorly soluble salts is expressed as the solubility product, i.e. the product of the concentration of cations and anions in the solution which are in equilibrium with the solid salt. These concentrations can be determined via conductivity measurements.

For more details refer to page 33.

Distribution equilibrium

P3030701 Principle At constant temperature and under constant pressure, a dissolved substance distributes itself between two immiscible liquids in a constant concentration ratio. This ratio is equal to the partition coefficient (distribution coefficient) of the substance examined in the given two-phase system.

For more details refer to www.phywe.com

Dissociation constants

P3031101 Principle The coloured indicator thymol blue is a weak acid that is partially dissociated in aqueous solution, whereby non-ionized and ionized forms show absorption maximums at different wavelengths in the visible range. Photometric measurements in the visible spectral range can therefore be used to advantage to determine the position of the Ka and pKa values of the indicator which characterize disscociation equilibrium.

For more details refer to page 35.

excellence in science 18


3 General Chemistry 3.2 Molar Mass

Determination of molar mass using the ideal gas law

P3010401

Rearranging the ideal gas equation to determine the molar mass.

Principle

Rotary vane pump, one stage, 115 V/230 V

All gases may be considered, to a first approximation, to obey the ideal gas equation which relates the pressure p, volume V, temperature T and amount of substance n of a gas. The amount of gas n is expressed as the number of moles and is equal to m / M where m is the mass of gas present and M is the mass of one mole of the gas. The volume occupied by a known mass of gas is to be measured at a given temperature and pressure, so that the ideal gas equation can be used to estimate the molar mass of the gas. Task Determine the molar masses of the gases helium, nitrogen, carbon dioxide, and methane. Function and Applications

What you can learn about ▪ ▪ ▪ ▪

One-stage rotary vane pump suitable for the continuous operation in the rough and fine vacuum range.

Molar mass and relative molar mass Properties of gases Ideal and ordinary gases Equations of state

Benefits

Main articles Rotary Vane pump, one stage, 115 V / 230 V Weather monitor, 6 lines LCD Sec.bottle500ml,2xGl18/8,1x25/12 Oil mist filter, DN 16 KF Glass sphere,w. 2 stopcocks,100ml Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

02740-95 87997-10 34170-01 02752-16 36810-00

1 1 1 1 1

49224-88

1

The pump has a high water vapour tolerance and a compact design. Due to their low weight, small dimensions and the high pumping speed, this pump is ideal to use in schools and laboratories. It is low maintenance, compact and exceptionally quiet. To prevent accidental damage the oil control glass is integrated into the housing. The casing of the pump is easy to wipe clean. Since a male ground joint ST 19 is supplied with the pump, pump plates with a ground socket ST19 can be put directly onto the pump.. 02740-95

PHYWE Systeme GmbH & Co. KG · www.phywe.com 19


3 General Chemistry 3.2 Molar Mass

P3010501

Determination of the molecular mass of a liquid

Measurement results of the molecular mass for methanol and diethyl ether.

Principle

Set gas laws with glass jacket, 230 V

The molar mass of a liquid is to be determined by evaporating a liquid at constant temperature and pressure, and measuring the volume of vapour formed using a calibrated gas syringe. Tasks 1. Determine the molar masses of diethyl ether and methanol. 2. Discuss the results in terms of the real and ideal behaviour of vapours. What you can learn about ▪ ▪ ▪ ▪

Ideal and ordinary gases Equations of state for ideal gases Gas volumetry Determination of molar masses according to the vapour density method (Victor Meyer)

Main articles Set gas laws with glass jacket, 230 V Weather monitor, 6 lines LCD Power regulator Methanol 500 ml Diethyl ether 250 ml Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

43003-88 87997-10 32288-93 30142-50 30007-25

1 1 1 1 1

49224-88

1

Function and Applications With this set, experiments on the following topics can be carried out: ▪ ▪ ▪ ▪

Gas law of Boyle-Mariotte Gas law of Gay-Lussac Gas law of Amonton (Charles) Determination of molar masses according to the vapour density method

Benefits This set allows to execute the measurements in a didactical clear and easy understandable way: ▪ Clear setup; Easy to understand ▪ Completely mercury-free ▪ Quickly to execute; Short preparation time 43003-88

excellence in science 20


3 General Chemistry 3.2 Molar Mass

Determination of molar masses via a measurement of the boiling point elevation (ebullioscopy)

P3021900

Equation to demonstrate the ebullioscopic constants of solvents with known molecular weight.

Principle

Apparatus for elevation of boiling point

Didactic setup to train and demonstrate the determination of molar masses by way of a measurement of the boiling point elevation. The boiling point elevation of aqueous solutions of different substances is determined using. The ebullioscopic constant of water is calculated from the experimental results. Tasks 1. Determine the boiling point elevation of aqueous solutions of different substances. 2. Calculate the ebullioscopic constant of water from the experimental results. What you can learn about ▪ ▪ ▪ ▪

Molar mass Boiling point elevation Ebullioscopy Ebullioscopic constant

Main articles Temperature meter digital, 4-2 Heating mantle for roundbottom flask, 250 ml, 230 V, with safety switch Apparatus for elevation of boiling point Desiccator, Wertex, diam. 150 mm Power regulator Temp. probe, immersion type, Pt100, stainless steel, -20...+300 °C Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13617-93

1

Function and Application Apparatus for determining molar mass, boiling point method.

49542-93 36820-00 34126-00 32288-93

1 1 1 1

11759-01

1

A thin tube lies along the side of the inner vessel almost reaching the bottom. This also allows the circulation of the escaping vapour.

49224-88

1

36820-00

Equipment and technical data: ▪

2 glass vessels of DURAN glass. The outer vessel has an inlet for introduction of vapour from the solvent mixture.

PHYWE Systeme GmbH & Co. KG · www.phywe.com 21


3 General Chemistry 3.2 Molar Mass

P3022000

Determination of molar masses via a measurement of the freezing point depression (cryoscopy)

Equation for the calculation of molar masses of a dissolved substance based on the measurement of the freezing-point depression of the solvent.

Principle

Apparatus for freezing point depression

In order to train and demonstrate the determination of molar masses by way of a measurement of the freezing-point depression, urea or hydroquinone are used as test substances. The cryoscopic constant of water is determined from the freezing point depression. Tasks 1. Determine the freezing point depression of water dissolving different amounts of hydroquinone and urea. 2. Calculate the cryoscopic constant from the experimental results. What you can learn about ▪ Cryoscopic constant ▪ Freezing point depression ▪ Molar mass

Main articles Temperature meter digital, 4-2 Magnetic stirrer MR Hei-Standard Desiccator, Wertex, diam. 150 mm Apparatus for freezing point depression Temp. probe, immersion type, Pt100, stainless steel, -20...+300 °C Pellet press for calorimeter Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13617-93 35750-93 34126-00 36821-00

1 1 1 1

11759-01 04403-04

1 1

49224-88

1

Function and Applications Apparatus for determining molarmass, freezing point method.The unit consists of an inner and an outer glass vessel of DURAN glass. The inner vessel has a flat bottom to accomodate magnetic stirrer bars and with lateral inlet for introduction of the substance to be tested. 36821-00

excellence in science 22


3 General Chemistry 3.2 Molar Mass

Determination of the molar masses of metals

P1309400

General equation to identify metals using the method of this experiment.

Principle A piece of metal is weighed and placed in the insert of the reaction cylinder, whereafter an acid is added to the cylinder through the three-way valve until it is about half full. The metal is made to react with the acid by lowering the insert. The gas syringe connected to the reaction cylinder is used to collect the hydrogen which is generated. The mass of the metal and the volume of the hydrogen generated are used to calculate the desired molar mass. The reaction can also be used to determine the valency of the metal.

Cobra4 hand-held pressure and temperature measuring instrument, Cobra4 Mobile-Link

Task Determine the molar mass of zinc. What you can learn about ▪ Molar mass ▪ Molar volume ▪ Ideal gas laws

Main articles Cobra4 hand-held pressure and temperature measuring instrument, Cobra4 Mobile-Link Frame for complete experiments Reaction cylinder with stopcock, GL25 Holder for syringes Gas syringe, 100 ml, with 3-way cock Panel for complete experimental setups Clamping holder, 0-13 mm, fixed magnet

12736-00 45500-00 35852-15 45523-00 02617-00 45510-00 02151-07

1 1 1 1 1 1 1

Function and Applications A combination of the Cobra4 Mobile-Link unit with the Cobra4 Sensor-Unit Thermodynamics is ideal for the measurement of pressure and temperatures simultaneously. Benefits Cobra4 Mobile-Link is a modern, powerful hand-held measuring device, to which any Cobra4 sensor units can be connected via a secure snap-in connection. 12736-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 23


3 General Chemistry 3.3 Acids and Bases

P3061660

Titration curves and buffering capacity (with Cobra4)

Titration curve of acetic acid with sodium hydroxide solution.

Principle pH values can be measured with the aid of electrochemical measurements and proton-sensitive electrodes (e.g. glass electrodes). By combining a glass electrode with a reference electrode in one housing, a single-rod glass electrode, which is appropriate for acid-base titrations, is created. The titration curves allow an exact determination of the equivalence point in titrations of strong and weak acids and bases.

Immers. probe NiCr-Ni, teflon, 300 °C Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

13615-05

1

49226-88

1

Cobra4 Sensor-Unit Drop Counter

Tasks 1. Determine the titration curves of different neutralisation reactions. 2. Determine the titration curve of an ampholyte (glycine). 3. Determine the buffering capacity of various aqueous acetic acid/sodium acetate mixtures at different total concentrations. What you can learn about ▪ ▪ ▪ ▪ ▪

Strong and weak electrolytes; Hydrolysis Dissociation of water; Amphoteric electrolytes Isoelectric point; Law of mass action; Indicators Glass electrode; Activity coefficient; Buffering capacity Henderson-Hasselbalch equation

The Cobra4 Drop Counter serves to count the number of drops that fall from a burette and so, indirectly, to quantitatively determine the volume of a liquid that flows from the burette. The Cobra4 Sensor-Unit Drop Counter can be connected to one of the following devices to transfer the measured data: Cobra4 Wireless-Link, Cobra4 Mobile-Link, Cobra4 USB-Link or Cobra4 Junior-Link. Benefits

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence

12600-00 12601-00

1 1

12630-00 12636-00 14550-61

1 1 1

excellence in science 24

Function and Applications

▪ ▪ ▪ ▪

Automatic performance of titration measurements Each single drop reliably measured Easy calculation of the volume in the software Easy to mount

12636-00


3 General Chemistry 3.3 Acids and Bases

Determination of the enthalpy of neutralisation (with Cobra3)

P3020811

Temperature-time curve of neutralisation and determining the heat capacity of the system.

Principle When a strong acid is neutralised with a strong base in dilute solution, the same amount of heat is always released. If the reaction takes place under isobaric conditions, this heat is known as the enthalpy of neutralisation. The chemical reaction which generates this heat is the reaction of protons and hydroxyl ions to form undissociated water. It therefore correlates to the enthalpy of formation of water from these ions. Tasks 1. Measure the temperature change during the neutralisation of a dilute potassium hydroxide solution with dilute hydrochloric acid. 2. Calculate the enthalpy of neutralisation.

Cobra4 Experiment - available 2013 Determination of the enthalpy of neutralisation (with Cobra4) P3020860

Set calorimetry, 230 V

What you can learn about ▪ Enthalpy of neutralisation ▪ Calorimetry ▪ Heat capacity

Main articles Set calorimetry, 230 V Cobra3 Data acquisition set for set calorimetry Delivery pipette Potassium hydroxid for 1l 1mol solution amp. Hydrochloric acid for 1mol solution amp. Rubber bulb, double Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

43030-88

1

43030-30 04402-10

1 1

31425-00 30271-00 39287-00

1 1 1

49226-88

1

Function and Applications With this setup a great number of measurements to heat capacities, reaction enthalpies, solution enthalpies, neutralisation enthalpies, melting enthalpies and enthalpies of mixtures can be carried out. 43030-88

PHYWE Systeme GmbH & Co. KG · www.phywe.com 25


3 General Chemistry 3.3 Acids and Bases

P1310100

Chemical fountain

Dissolution of hydrogen chloride in water. Approx. 443 l of hydrogen chloride are soluble in 1 l of water.

Principle

Panel for complete experiment setups

Some gases such as hydrogen chloride dissolve readily in water. For example, 1 litre of water at 20 °C can dissolve approximately 443 litres of hydrogen chloride. For example, vacuum builds up quickly in a closed flask when the gas comes in contact with water, because the gas dissolves in the water and additional water is drawn into the flask. This is the basis of how the chemical fountain works - an exciting way to demonstrate the solubility of gases in water. In the variant depicted here, the hydrogen chloride is generated, fills the flask of the fountain and causes the fountain to fizz - all in a single apparatus. Task Show the great solubility of hydrochloric acid in water using the chemical fountain. What you can learn about ▪ Solubility ▪ Hydrochloric acid ▪ Acids

Function and Applications Panel with regular punching to receive the hooks of the holder horizontal or vertical positioning in the frame, one panel is neccessary for each experiment.

Main articles Frame for complete experiments Funnel for gas generator, 50 ml, GL18 Apparatus carrier w. fix. magnet Panel for complete experimental setups Quartz glass wool 10 g Glass sphere with 4 tubes Clamping holder, turnable, 18-25 mm

45500-00 35854-15 45525-00 45510-00 31773-03 44551-00 45521-00

excellence in science 26

1 1 1 1 1 1 1

Equipment and technical data ▪ Material: sheet steel, powder painted with good mechanical and chemical resistance ▪ Dimensions (LxHxW): 65x48.8x2.5 cm 45510-00


3 General Chemistry 3.3 Acids and Bases

Titration of a polyvalent acid with a strong base (with Cobra4)

P3121260

Principle Phosphoric acid and sodium hydroxide are to be used to give an example of a titration of a polyvalent acid with a strong base. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Phosphoric acid Sodium hydroxide Polyvalent acid pKa values Proteolysis pH value

For more details refer to www.phywe.com

Titration of a weak organic acid with sodium hydroxide (with Cobra4)

P3121360

Principle Acetic acid and sodium hydroxide are to be used to give an example of a titration of a weak organic acid with sodium hydroxide. What you can learn about ▪ ▪ ▪ ▪ ▪

Buffer Neutralisation pH-value Henderson-Hasselbalch equation pKa value

For more details refer to www.phywe.com

Titration of a weak base (ammonia) with a strong acid (with Cobra4)

P3121460

Principle The titration of ammonia solution with hydrochloric acid is used here as a typical example of a titration of a weak base with a strong acid. What you can learn about ▪ ▪ ▪ ▪ ▪

Buffer Neutralisation pH-value Henderson-Hasselbalch equation pKa value

For more details refer to www.phywe.com

PHYWE Systeme GmbH & Co. KG · www.phywe.com 27


3 General Chemistry 3.4 Solutions and Mixtures

P3030501

Solubility diagram of two partially miscible liquids

Solubility diagram of the phenol/water system.

Principle A number of different mixtures of phenol and water are prepared and heated until complete miscibility is achieved. As the mixtures cool, two-phase systems form at certain temperatures which are recognisable by the appearance of turbidity. Plotting separation temperatures against compositions of the mixtures gives the separation curve. Tasks 1. Plot the separation curve of the phenol / water binary system and prepare a temperature / mass fraction diagram. 2. Determine the critical separation point. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Binary system Miscibility gap Mixed phase Coexisting phase Raoult's law Critical dissolution temperature

Main articles Immersion thermostat Alpha A, 230 V Bath for thermostat, Makrolon Rack for 20 test tubes, Makrolon External circulation set f. thermostat Alpha A Retort stand, h = 750 mm Burette clamp, roller mount., 2 pl. Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

08493-93 08487-02 08487-03 08493-02 37694-00 37720-00

1 1 1 1 1 1

49224-88

1

excellence in science 28


3 General Chemistry 3.4 Solutions and Mixtures

Miscibility gap in a ternary system

P3030601

Triangular diagram of the system acetic acid/ chloroform/water.

Principle

Periodic system with colour pictures

A number of completely miscible two component mixtures are prepared to investigate the three component acetic acid / chloroform / water system. These mixtures are titrated with the third component until a two phase system is formed which causes turbidity. The phase diagram for the three component system is plotted in a triangular diagram. Tasks 1. Titrate nine different acetic acid / chloroform mixtures with water until a two phase system is formed in each case. 2. Titrate six acetic acid / water mixtures with chloroform until phase separation is observed. 3. Plot the results of the titrations, expressed as molar fractions, in a triangular diagram. What you can learn about ▪ ▪ ▪ ▪ ▪

Three component system Miscibility gap Phase diagram Triangular diagram Gibb's phase law

Wall map in multicoloured offset printing on flexible Pretex-foil with rods. Benefits

Main articles Immersion thermostat Alpha A, 230 V Bath for thermostat, Makrolon Rack for 20 test tubes, Makrolon External circulation set f. thermostat Alpha A Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

Function and Applications

08493-93 08487-02 08487-03 08493-02

1 1 1 1

49224-88

1

▪ The elements are shown with an application, the commercial form, radioactive elements with the radioactivity symbol and the half-life. ▪ The photos supply informations about appearance and aggregate state, metal or nonmetal character, modifications, storage and reactivity of the elements. ▪ Important correlations of the periodic table can be recognized immediately, basic properties of the elements are memorized. Equipment and technical data ▪ Dimensions (L x H): 195 x 138 cm 47310-02

PHYWE Systeme GmbH & Co. KG · www.phywe.com 29


3 General Chemistry 3.4 Solutions and Mixtures

P4100760

The origin of acid rain (with Cobra4)

pH-time curve for SO2, NO2 and CO2.

Principle

Cobra4 Wireless-Link

Acid rain is caused by emissions from power plants, households and traffic. Gases such as sulfur dioxide, nitrogen dioxide and carbon dioxide dissolve in rainwater, the products of which form the acids (acids containing sulfur, nitrous acid, nitric acid, carbonic acid). Acid rain reduces the pH of soils and waters. Environmental damage such as forest dieback is the result. In this experiment acid rain will be produced artificially by adding the gases SO2, NO2 and CO2 to water. The fall of the pH value is registered. Task Add the gases SO2, NO2 and CO2 to water and record the fall of the pH value. What you can learn about ▪ ▪ ▪ ▪ ▪

Acid rain Anthropogenic air pollution Damage to forests Acidification of soil and water Gaseous and aerosol emissions

Interface module for the radio-based transmission of sensor measuring values in conjunction with the Cobra4 Wireless Manager. Benefits

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit pH, BNC connector pH-electrode, plastic body, gel, BNC Software Cobra4 - multi-user licence Retort stand, h = 750 mm Separatory funnel, 100 ml pear-sh.

Function and Applications

12600-00 12601-00 12631-00 46265-15 14550-61 37694-00 36883-00

1 1 1 1 1 2 1

▪ All Cobra4 Sensor-Units can be quickly connected using a secure and reliable plug-in / lockable connection. ▪ All Cobra4 measuring sensors are easy to plug in and automatically detected. ▪ The radio network with the Cobra4 Wireless Manager is established automatically and is extremely stable, as it uses its own radio protocol. ▪ Up to 99 Cobra4 Wireless-Links can be connected to one Cobra4 Wireless Manager. ▪ No more cable mess, thanks to radio measuring. ▪ With radio transmission, moving sensors offer completely new experimentation options, e.g. the measurement of acceleration of a student on a bicycle etc. 12601-00

excellence in science 30


3 General Chemistry 3.4 Solutions and Mixtures

Concentration cells without transport: Determination of the solubility products of silver halides (with Cobra4)

P3061062

Mean acitvity coefficients f± for AgNO3, KCl, KBr, KI at T = 25 °C.

Principle A concentration cell is constructed from two half-cells which are identical, except that the concentration of the ionic species to which the electrode is sensitive is different in the two sides of the cell. Such a cell may be used to measure the solubility product of a sparingly soluble salt. In one half-cell the concentration of these ions is known, in the other it is determined by the solubility product of the salt under investigation. The ratio of the two concentrations (more accurately, activities) determines the e.m.f. of the cell. Task Use a concentration cell made from two Ag(s) l Ag+(aq) electrodes, to determine the solubility product of the three silver halides AgCl, AgBr and AgI. What you can learn about ▪ Concentration cells without transport; Electromotive force ▪ Salt bridge; Liquid junction and diffusion potentials

Main articles Cobra4 Mobile-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Immersion probe NiCr-Ni, teflon, 300 °C Silver nitrate, cryst. 15 g Silver foil, 150 x150 x 0.1 mm, 25 g Clay pins, d = 8 mm, l = 15 mm, 2 pcs. Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

12620-00

1

12630-00 13615-05 30222-00 31839-04 32486-00

1 1 1 1 1

49221-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 31


3 General Chemistry 3.4 Solutions and Mixtures

P1135700

Osmosis - dependence of the osmotic pressure on the concentration

Levels of different solutions during experiment.

Principle Osmosis describes the phenomenon that solvent molecules move through a partially permeable membrane into a region of higher solute concentration. Thus, the concentration of solute is equalized on both sides. The experimental set-up consists of seven chambers that are filled with solutions of sugar with different concentrations. The liquid column in the capillaries is determined and the dependence of the osmotic pressure on the concentration can easily be shown.

Related Experiment Determination of diffusion potentials P3061101

Tasks 1. Investigate the phenomenom of osmosis in a simple model experiment. 2. Determine the dependence of osmotic pressure on concentration of dissolved molecules. What you can learn about ▪ Osmosis ▪ Osmotic pressure ▪ Concentration

Main articles Osmosis and electrochemistry chamber Supplement chamber for osmosis / electro chemistry Filtration stand for 2 funnels Scale 350 mm D(+)-glucose 1-hydr. 250 g Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35821-00

1

35821-10 33401-88 64840-00 30237-25

5 1 7 1

49224-88

1

excellence in science 32

Jacobus Henricus van ’t Hoff 1901, Nobel Prize in Chemistry


3 General Chemistry 3.4 Solutions and Mixtures

Solubility product (with Cobra4)

P3030862

Ionic conductivities at infinite dilution.

Principle The solubility of poorly soluble salts is expressed as the solubility product, i.e. the product of the concentration of cations and anions in the solution which are in equilibrium with the solid salt. These concentrations can be determined via conductivity measurements.

Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000)

Tasks 1. Measure the conductivities of saturated aqueous solutions of the salts calcium fluoride and calcium carbonate at 25 °C. 2. With the aid of tabulated ionic conductivities, calculate the solubility products of the salts from their conductivities. What you can learn about ▪ ▪ ▪ ▪

Solubility Dissociation Electrolytic conductance Activity

Function and Applications

Main articles Cobra4 Mobile-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Conductivity temperature probe Pt1000 Immersion thermostat Alpha A, 230 V Bath for thermostat, Makrolon Magnetic stirrer Mini / MST Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

12620-00

1

12632-00 13701-01 08493-93 08487-02 47334-93

1 1 1 1 1

49224-88

1

The Cobra4 Sensor Unit Conductivity / Temperature (Pt1000) is a microcontroller-based measuring recorder with a 5-pin diode socket for connecting conductance measuring sensors with a cell constant of K = 1.00/cm or Pt1000 thermocouples. Benefits ▪ Measure conductivity or temperature - multipurpose-sensor. ▪ The Cobra4 sensor may be connected directly to the Cobra4 Wireless-Link, the Cobra4 Mobile-Link, the Cobra4 USB-Link or the Cobra4 Junior-Link using a secure and reliable snap-in connection. 12632-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 33


3 General Chemistry 3.4 Solutions and Mixtures

P3030960

Dissociation equilibrium (with Cobra4)

Neutralisation curve of formic acid.

Principle

Cobra4 Wireless Manager

Carboxylic acids are potential electrolytes which exist in a weakly dissociated condition in aqueous solutions. The location of the dissociation equilibrium is quantitatively described by the Ka or pKa value which can be determined with potentiometric measurements. Tasks 1. Measure the alteration of the pH value during a titration of approximately 0.1 molar aqueous solutions of formic acid, acetic acid, monochloroacetic acid, propionic acid, butyric acid and lactic acid with a 0.1 molar sodium hydroxide solution at constant temperature using Cobra4 system. 2. From the neutralisation curves read the pKa values of the acids and compare them. What you can learn about ▪ True and potential electrolytes; Strong and weak acids; Law of mass action ▪ Henderson-Hasselbalch equation; Dissociation constant and pKa value; Substituent effects; Potentiometry

Function and Applications

Main articles

USB device for radio-based communication with the Cobra4 Wireless-Link.

Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

12600-00 12601-00

1 2

12630-00 12636-00 14550-61

1 1 1

49224-88

1

excellence in science 34

Benefits ▪ Simply connect the device to the computer's USB port. ▪ Up to 99 measuring sensors can be connected to one computer ▪ Automatic detection of all connected measuring sensors. 12600-00


3 General Chemistry 3.4 Solutions and Mixtures

Dissociation constants

P3031101

Principle

Spectrophotometer 190-1100 nm

The coloured indicator thymol blue is a weak acid that is partially dissociated in aqueous solution, whereby non-ionized and ionized forms show absorption maximums at different wavelengths in the visible range. Photometric measurements in the visible spectral range can therefore be used to advantage to determine the position of the Ka and pKa values of the indicator which characterize dissociation equilibrium. Tasks 1. Experimentally determine the extinction (absorbance) of an aqueous solution of thymol blue (thymolsulphonephthalein) in dilute HCl, NaOH and a buffer of known pH value as a function of wavelength between 400 and 700 nm at constant concentration and constant temperature. 2. Calculate the dissociation constant (indicator constant) Ka from the measurement results. What you can learn about ▪ ▪ ▪ ▪

True and potential electrolytes; Strong and weak acids Law of mass action; Dissociation constants and pKa values Henderson-Hasselbalch- Equation; UV-VIS spectrometry Lambert-Beer's Law; Photometry

Main articles Spectrophotometer 190-1100 nm Cells for spectrophotometer, opt. glass, 2 pcs. Buffer solution, pH 9 1000 ml Ethyl alcohol, absolute 500 ml Thymol blue indicator 5 g Thermometer -10...+50 °C Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35655-93 35664-02 30289-70 30008-50 31896-02 38034-00

1 1 1 1 1 1

49224-88

1

Function and Applications Spectrophotometer 190-1100 nm Benefits ▪ The UV-VIS spectral photometer is characterised by its compact design and due to its wide range of possible uses. ▪ Operation is via a clearly set out overlay keyboard on the screen dialogue. ▪ Current wavelengths and measured values can be displayed in large format. ▪ Alternatively, all measured values can also be presented graphically or in table format on the LCD screen with background lighting. ▪ Strong light, high performance optics enable absorption and transmission measurements to be taken in the whole wavelength range of 200 to 1100 nm with automatic switching between the two light sources. 35655-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 35


3 General Chemistry 3.4 Solutions and Mixtures

Boiling point elevation

P3021001 Principle The boiling point of a solution is always higher than that of the pure solvent. The dependence of the temperature difference (elevated boiling point) on the concentration of the solute can be determined using a suitable apparatus.

For more details refer to page 117.

Freezing point depression

P3021101 Principle The freezing point of a solution is lower than that of the pure solvent. The depression of the freezing point can be determined experimentally using a suitable apparatus (cryoscopy). If the cryoscopy constants of the solvent are known, the molecular mass of the substance dissolved can be determined.

For more details refer to page 118.

excellence in science 36


3 General Chemistry 3.5 Redox Reactions

Redox reactions between metals and metal oxides (thermite process)

P3110600

Experimental setup.

Principle The experiments described here are highly suitable for demonstrating the different affinity of various metals in view of oxygen. The less noble a metal is the higher its affinity to oxygen and the more thermal energy is released during its oxidation. The technical importance of the thermite process for the welding of iron parts is that it is relatively easy to produce large amounts of liquid iron and, thereby, to fill wider weld grooves. This is why this process is mainly used for welding thick steel beams, rail tracks, and machine parts. Tasks 1. Reduction of copper oxide with iron. 2. Reduction of iron oxide with aluminium (thermite process, aluminothermics). What you can learn about ▪ Redox reaction; Thermite process ▪ Metals; Welding of iron; Aluminothermics ▪ Iron; Aluminium

Main articles Retort stand, h = 750 mm Iron powder xtra pure 1000 g Magnet, d = 10 mm, l = 200 mm Teclu burner, DIN, natural gas Ignition sticks for thermite, 50 pcs. Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

37694-00 30068-70 06311-00 32171-05 31921-05

1 1 1 1 1

49224-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 37


3 General Chemistry 3.5 Redox Reactions

P3100300

Reduction - reducing agents - redox process

Reduction of ferric oxide with hydrogen.

Principle

Gas bar

The reduction, as the reversal of the oxidation, can be achieved thermally or with the aid of a reducing agent. Some metal oxides can be decomposed into the metal and oxygen under the influence of thermal energy. In the case of less noble metals, a reducing agent is required for obtaining the elements. The redox processes during the preparation of lead demonstrate the relationship between oxidation and reduction. By way of this experiment it can be shown that during the reduction of an oxide the reducing agent itself is oxidised: hydrogen to water, carbon to carbon dioxide. A reduction process is always coupled with an oxidation process, which is why this type of reaction is referred to as a redox reaction. Tasks 1. Reduction of lead(IV) oxide to lead(II) oxide by thermolysis. 2. Reduction of lead(II) oxide by way of charcoal to obtain elementary lead. 3. Reduction of iron oxide including the formation of hydrogen based on pyrophoric iron. What you can learn about ▪ Reduction; Oxidation; Redox reaction ▪ Lead; Iron; Thermolysis

Function and Applications

Main articles Steel cylinder hydrogen, 2 l, full Gas bar Reducing valve for hydrogen Table stand for 2 l steel cylinders Combustion tube, 300 mm, quartz, ns

41775-00 40466-00 33484-00 41774-00 33948-01

excellence in science 38

1 1 1 1 1

Gas bar to provide small quantities of gas ready to use, e.g. hydrogen and oxygen when using the eudiometer. The required gas quantity can be removed with a syringe through the rubber cap. Two small gasometers, capacity app. 200 mml gas. Each max. filling pressure 30 bar. With tripod and stickers for labelling. 40466-00


3 General Chemistry 3.5 Redox Reactions

Reduction of lead oxide

P3100400

The blast furnance with which iron can be obtained from iron oxide.

Principle Lead oxide is reduced to lead; in the process the carbon is oxidised to carbon dioxide. ln this experimental set-up and also in the blast furnace process, the reducing agent proper is not carbon, but rather the carbon monoxide generated due to the oxygen deficit. Task Demonstrate the reduction of lead oxide. What you can learn about ▪ ▪ ▪ ▪ ▪

Lead Carbon monoxide Reduction Oxidation Redox reaction

Main articles Support base variable Lead-II oxide -litharge- 500 g Bunsen burner DIN, natural gas Activated carbon, granular 250 g Ring with boss head, i. d. = 10 cm Support rod, stainless steel, l = 600 mm, d = 10 mm Safety gas tubing, DVGW, sold by metre

02001-00 31121-50 32165-05 30011-25 37701-01

1 1 1 1 1

02037-00 39281-10

1 1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 39


3 General Chemistry 3.5 Redox Reactions

Sulphur trioxide - the sulphuric acid contact process

P3110400

Principle The contact process is currently used in the chemical industry to produce sulphuric acid in the high concentrations needed for industrial processes. In this model experiment, platinumpalladium-aluminium-oxide beads are employed as a catalyst for the reaction.

For more details refer to page 171.

Preparation of iron from oxidic ores (blast furnace process)

P3110500

Principle This is a model experiment to show the industrial blast furnace process to produce iron from iron(III) oxide. During the experiment a furnace gas flame that is approximately 10 to 20 cm high can be ignited at the stack outlet. Cavities form in the burning carbon layer. These cavities collapse over time. Apart from ash and carbon residues, metallic lumps can also be found in the frame after the end of the experiment. Samples of these lumps lead to the formation of hydrogen when they are treated with hydrochloric acid.

For more details refer to page 182.

Volumetric redox titration: Cerimetry (with Cobra4)

P3121060

Prinicple Potassium permanganate solutions which are used as oxidizing measuring solutions in redox titrations can in most cases be replaced by Ce(IV) solutions. These offer the advantages that they do not change on storage and that the course of the redox titration can be very conveniently followed by measuring the electrochemical potential. The equivalent point can then be found by determination of the inflection point of the potential curve which results from plotting the measured values.

For more details refer to page 48.

excellence in science 40


3 General Chemistry 3.6 Stoichiometry

The empirical formula of methane, ethane and propane

P3110900

Reaction equation of the combustion of hydrocarbons.

Principle

Slow eudiometer

A quiescent eudiometer is inserted into the glass jacket and the glass jacket is filled with cold water. Gas mixtures composed of hydrocarbons and oxygen are injected into the eudiometer and burn there continuously at the constant sparking of the ignition spark gap. The water formed by the reaction condenses on the cool walls of the eudiometer. For this reason, the volume between the moving plunger and the fixed plunger with the ignition system after combustion is smaller than the volume of the gas mixture originally injected. In a second part of the experiment, the eudiometer in the glass jacket is heated up to over 100°C. The water formed during combustion can no longer condense on the hot eudiometer walls. In most cases, even after conversion to standard conditions, the volume recorded then is greater than the volume of the gas that was injected. The easiest way to convert the volumes to standard conditions is with a nomogram. The measurement data obtained in this way can be used to derive the empirical formulas of gaseous hydrocarbons experimentally.

Main articles High voltage supply unit, 0-10 kV Slow eudiometer Cobra4 hand-held pressure and temperature measuring instrument, Cobra4 Mobile-Link Glass jacket Heating apparatus for glass jacket system Steel cylinder oxygen, 2 l, filled Power regulator

13670-93 02612-00

1 1

12736-00 02615-00 32246-93 41778-00 32288-93

1 1 1 1 1

Function and Applications Eudiometer, silent for the determination of volume ratios for continuous combustion of gas mixtures. Benefits ▪ Glass cylinder with scale, as well as fixed and movable pistons ▪ Ignition over a duration of sparks from a high voltage device ▪ The gasmixtures are simply injected into the eudiometer using an injection syringe. ▪ The ignition of the gas mixture then occurs easily and safely with the aid of the ignition spark generator. 02612-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 41


3 General Chemistry 3.6 Stoichiometry

P3111000

Avogadro's law

Schematical set-up of the experiment.

Principle

Plunger eudiometer

In 1811, Avogadro stated his hypothesis that under the same conditions of pressure and temperature, equal volumes of all gases contain equal numbers of components (molecules, atoms). He derived this from the uniformity of the behaviour of (ideal) gases on increases in temperature and pressure (see the Gas Laws) and the Law of Volumes. When Avogadro's supposition is correct, then 6 parts by volume of CO and 3 parts by volume of 02 must form 6 parts by volume of C02 when pressure and temperature are the same before and after the reaction. Similarly, at a temperature a little above 100°C, a gas mixture containing 6 parts by volume of H2 and 3 parts by volume of 02 must give 6 parts by volume of steam, and a mixture containing 5 parts by volume of H2 and 5 parts by volume of Cl2 must give 1 0 parts by volume of HCI. In the following experiments we will carry out the reactions named above to test the correctness of the hypothesis. Tasks Perform the following reactions to verify Avogadro's law: 1. 2. 3. 4.

What you can learn about ▪ Avogadro; Gas laws; Carbon monoxide ▪ Hydrogen; Chlorine; Oxygen

Main articles 02611-00 02615-00 41775-00 32246-93 41778-00 32288-93

excellence in science 42

The plunger eudiometer consists of aglass cylinder with movable plunger and is used to determine the ratio of volumes in explosive gas reactions. Benefits

Preparation of carbon monoxide and chlorine The carbon monoxide/oxygen reaction The hydrogen/oxygen reaction at above 100°C The hydrogen/chlorine reaction at above 100°C

Plunger eudiometer Glass jacket Steel cylinder hydrogen, 2 l, full Heating apparatus for glass jacket system Steel cylinder oxygen, 2 l, filled Power regulator

Function and Applications

1 1 1 1 1 1

▪ Two 4-mmsockets connect the ignition spark generator. ▪ This device can be used to cause gas mixtures to react at room temperature, which lead to gaseous reaction products or in which residual quantities of the reaction gases remain in the cylinder (e.g. mixtures of air and hydrogen, of carbon monoxide and oxygen). ▪ The gasmixtures are simply injected into the eudiometer using an injection syringe. ▪ The ignition of the gas mixture then occurs easily and safely with the aid of the ignition spark generator. ▪ If the plunger eudiometer is assembled in the glass jacket, the ratio of volumes of gas reactions can also be investigated at temperatures other that room temperature, such as the reaction of a stochiometric mixture of hydrogen and oxygen at above 100°C. 02611-00


3 General Chemistry 3.6 Stoichiometry

Briggs-Rauscher Reaction (with Cobra4)

P3121660

Graph of measured potential against time.

Principle

Cobra4 Wireless Manager

The Briggs-Rauscher reaction is a so-called homogeneous oscillating reaction, i.e. the reaction rate of the complete process is subject to periodic fluctuations. In general, oscillating reactions can always occur when the following conditions are fulfilled: The reaction must run highly exergonic (ΔG << 0). At least one of the reaction steps must contain a positive or negative back-coupling. Such back-coupling processes occur when the result of the individual partial steps of the reaction, such as changes in temperature or concentration, act back on the rate constants of the individual partial steps of the reaction. In this way, the whole reaction becomes non-linear. Task

Function and Applications

Observer the fluctuations of the Briggs-Rauscher reaction by measuring the potential over a definite time period.

USB device for radio-based communication with the Cobra4 Wireless-Link.

What you can learn about

Benefits

▪ Oscillating reactions; Exergonic process ▪ Potential, Briggs-Rauscher reaction

▪ Simply connect the device to the computer's USB port. ▪ Up to 99 measuring sensors can be connected to one computer ▪ Automatic detection of all connected measuring sensors.

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Software Cobra4 - multi-user licence Magnetic stirrer Mini / MST Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

12600-00 12601-00

1 1

12630-00 14550-61 47334-93

1 1 1

49224-88

1

Equipment and technical data ▪ ▪ ▪ ▪ ▪ ▪ ▪

Power consumption: < 100 mA Connection voltage (via USB): 5 V Radio output power: 1 mW Max. data rate (burst):125,000 values/s Range with no obstacles: 20 m max. number of Cobra4 Wireless-Links in the network: 99 Dimensions (LxBxH): 75 x 25 x 10 mm; Weight: 20 g

12600-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 43


3 General Chemistry 3.6 Stoichiometry

P1309400

Determination of the molar masses of metals

General equation to identify metals using the method of this experiment.

Principle A piece of metal is weighed and placed in the insert of the reaction cylinder, whereafter an acid is added to the cylinder through the three-way valve until it is about half full. The metal is made to react with the acid by lowering the insert. The gas syringe connected to the reaction cylinder is used to collect the hydrogen which is generated. The mass of the metal and the volume of the hydrogen generated are used to calculate the desired molar mass. The reaction can also be used to determine the valency of the metal.

Cobra4 hand-held pressure and temperature measuring instrument, Cobra4 Mobile-Link

Task Determine the molar mass of zinc. What you can learn about ▪ Molar mass ▪ Molar volume ▪ Ideal gas laws

Main articles Cobra4 hand-held pressure and temperature measuring instrument, Cobra4 Mobile-Link Frame for complete experiments Reaction cylinder with stopcock, GL25 Holder for syringes Gas syringe, 100 ml, with 3-way cock Panel for complete experimental setups Clamping holder, 0-13 mm, fixed magnet

Function and Applications 12736-00 45500-00 35852-15 45523-00 02617-00 45510-00 02151-07

1 1 1 1 1 1 1

A combination of the Cobra4 Mobile-Link unit with the Cobra4 Sensor-Unit Thermodynamics is ideal for the measurement of pressure and temperatures simultaneously. Benefits Cobra4 Mobile-Link is a modern, powerful hand-held measuring device, to which any Cobra4 sensor units can be connected via a secure snap-in connection. 12736-00

excellence in science 44


4 Analytical Chemistry

Analytical Chemistry 4.1 4.2 4.3

Titration Electrogravimetry Chromatography

46 51 52

PHYWE Systeme GmbH & Co. KG · www.phywe.com 45


4 Analytical Chemistry 4.1 Titration

P3060760

Conductivity titration (with Cobra4)

Titration diagram for the neutralisation of HCI solution with NaOH solution.

Principle

Conductivity temperature probe Pt1000

The electric conductivity of aqueous electrolyte solutions is determined by the type and number of charge carriers at constant temperature. Characteristic changes in conductivity are connected with changes in the ionic composition of reacting systems. These can be used in the conductiometric titration as end point indicators. Tasks Using the Cobra4 system, measure the change in conductivity in the titrations of the following: 1. approximately 0.1 molar barium hydroxide solution with 0.1 molar sulphuric acid. 2. approximately 0.1 molar hydrochloric acid with 0.1 molar sodium hydroxide solution. 3. approximately 0.1 molar acetic acid with 0.1 molar sodium hydroxide solution. Other samples can alternatively be set in advance for conductiometric determination of their concentration contents. What you can learn about

Function and Applications

▪ Electrolyte; Electrical conductance; Specific conductance ▪ Ion mobility; Ion conductivity; Conductometry; Volumetry

Conductivity temperature probe Pt1000.

Main articles

▪ Cell constant k = 1.0 / cm ▪ Minimum immersion depth: 10 mm

Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Conductivity temperature probe Pt1000 Software Cobra4 - multi-user licence

12600-00 12601-00

1 1

12632-00 13701-01 14550-61

1 1 1

excellence in science 46

Equipment and technical data

13701-01


4 Analytical Chemistry 4.1 Titration

Potentiometric pH titration (phosphoric acid in soft drinks) (with Cobra4)

P3061760

Titration diagram of the neutralisation of a beverage containing phosphoric acid (V = 50 ml) with a 0.1 molar sodium hydroxide solution.

Principle The cell voltage and the Galvani voltage of the electrodes of a galvanic cell are dependent upon the concentration of the ions involved in the potential forming process. Thus, conclusions can be made about the concentration of the ions to be investigated from the measured cell voltage at a constant potential of a suitable reference electrode (potentiometric titration). Tasks Using the Cobra4-System, measure the change in the cell voltage in the titration of a) diluted phosphoric acid with 0.1 molar sodium hydroxide solution. b) a sample of a carbonated beverage (Cola) containing phosphoric acid (E338) with 0.1 molar sodium hydroxide solution and calculate the beverage's phosphoric acid content from the consumption of the standard solution. What you can learn about ▪ Galvanic cell; Types of electrodes; Galvani voltage ▪ Cell voltage; Nernst equation; Potentiometry; Volumetry

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence Immers. probe NiCr-Ni, teflon, 300 °C Magnetic stirrer Mini / MST

12600-00 12601-00

1 2

12630-00 12636-00 14550-61 13615-05 47334-93

1 1 1 1 1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 47


4 Analytical Chemistry 4.1 Titration

P3121060

Volumetric redox titration: Cerimetry (with Cobra4)

Measurement curve for the titration of 10 ml of an 0.1 molar Fe(II) sulphate solution with 10 ml of an 0.1 molar Ce(IV) sulphate solution with the equivalent point entered.

Principle

Software Cobra4 - multi-user licence

Potassium permanganate solutions which are used as oxidizing measuring solutions in redox titrations can in most cases be replaced by Ce(IV) solutions. These offer the advantages that they do not change on storage and that the course of the redox titration can be very conveniently followed by measuring the electrochemical potential. The equivalent point can then be found by determination of the inflection point of the potential curve which results from plotting the measured values. Task Titrate Iron(II) sulphate solution with Ce(IV) sulphate solution. What you can learn about ▪ Redox titration; Iron(II) sulphate ▪ Ce(IV) sulphate; Titration ▪ Cerimetry Function and Applications

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence Magnetic stirrer Mini / MST Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

12600-00 12601-00

1 1

12630-00 12636-00 14550-61 47334-93

1 1 1 1

49226-88

1

excellence in science 48

The "measure Cobra4" measuring software leaves nothing to be desired. As soon as a Cobra4 sensor is connected to a PC, irrespective of whether by Cobra4 Wireless or Cobra4 USB Link, the "measureCobra4" software opens completely automatically and shows the connected sensors, the required measuring windows and the current measuring data. 14550-61


4 Analytical Chemistry 4.1 Titration

Precipitation titration (with Cobra4)

P3061460

Course of the potential during the precipitation titration.

Principle Precipitation reactions which occur stoichiometrically and rapidly, and whose equilibrium lies on the side of the poorly soluble products can also be used titrimetrically. Consequently, a solution which contains both chloride and iodide ions can be titrated with a silver nitrate solution. The course of the titration is monitored potentiometrically and the equivalence points are determined from the inflection points of the potential curve.

Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni

Tasks 1. Titrate a solution which contains 10 ml each of 0.1 molar potassium chloride and potassium iodide solutions with a 0.1 molar silver nitrate soltution. 2. Plot the potential of a silver electode measured against a silver / silver chloride reference electrode as a function of the added volumes of standard solution. 3. Determine the equivalence points from the inflection points of the potential curve. What you can learn about

The Cobra4 Sensor-Unit pH and 2 x temperature NiCr-Ni is a measuring recorder for pH, potential and temperature measurements, which is controlled by micro-controller. Benefits

▪ Electrode potential; Cell voltage ▪ Electrodes of the 1st and 2nd type ▪ Nernst equation; Argentometry; Solubility product

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence

Function and Applications

12600-00 12601-00

1 2

12630-00 12636-00 14550-61

1 1 1

▪ It can be fitted with two NiCr-Ni thermoelements (Type K) and a pH probe or redox measuring chain ▪ Measure up to two temperatures and one pH or potential value simultaneously. ▪ Discover new experimental possibilities especially in thermodynamics ▪ Values of the calibration are saved in the sensor - no need for new calibration after changing the basic unit. 12630-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 49


4 Analytical Chemistry 4.1 Titration

P3061660

Titration curves and buffering capacity (with Cobra4)

Titration curve of acetic acid with sodium hydroxide solution.

Main articles Principle pH values can be measured with the aid of electrochemical measurements and proton-sensitive electrodes (e.g. glass electrodes). By combining a glass electrode with a reference electrode in one housing, a single-rod glass electrode, which is appropriate for acid-base titrations, is created. The titration curves allow an exact determination of the equivalence point in titrations of strong and weak acids and bases. Tasks

12600-00 12601-00

1 1

12630-00 12636-00 14550-61 13615-05

1 1 1 1

49226-88

1

1. Determine the titration curves of different neutralisation reactions. 2. Determine the titration curve of an ampholyte (glycine). 3. Determine the buffering capacity of various aqueous acetic acid/sodium acetate mixtures at different total concentrations.

Titration of a polyvalent acid with a strong base (with Cobra4)

What you can learn about

P3121260

▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Strong and weak electrolytes Hydrolysis Dissociation of water Amphoteric electrolytes Isoelectric point Law of mass action Indicators Glass electrode Activity coefficient Buffering capacity Henderson-Hasselbalch equation

excellence in science 50

Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence Immersion probe NiCr-Ni, teflon, 300 °C Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

Related Experiments

Titration of a weak organic acid with sodium hydroxide (with Cobra4) P3121360 Titration of a weak base (ammonia) with a strong acid (with Cobra4) P3121460


4 Analytical Chemistry 4.2 Electrogravimetry

Electrogravimetric determination of copper

P3062201

Electric circuit for electrolysis.

Principle

Power supply, universal

Electrogravimetry is an important analytical method for the quantitative determination or separation of species in solution. The technique involves the quantitative electrolytic deposition of an element, usually a metal, on a suitable electrode in weighable form. Task Perform an accurate electrogravimetric determination of the amount of copper in a given sample solution. What you can learn about ▪ ▪ ▪ ▪ ▪

Quantitative analysis Gravimetry Electrolysis Overpotential Electrode polarisation

Function and Applications Versatile heavy duty power supply which can also be used as a constant current supply in schools, laboratories or workshops. Equipment and technical data

Main articles Pt electrodes, electrogravimetry Power supply, universal Magnetic stirrer MR Hei-Standard Electronic temperature controller EKT Hei-Con Digital multimeter 2010 Ethyl alcohol, absolute 500 ml Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

45210-00 13500-93 35750-93 35750-01 07128-00 30008-50

1 1 1 1 2 1

49221-88

1

▪ Direct current source: Stabilised, regulated output direct voltage, continuously adjustable from 0...18 V ▪ Adjustable current limit between 0...5 A ▪ LED display for constant current operation ▪ Permantely short-circuit proof & protected against exterior voltages ▪ Alternative voltage output: ▪ Multitap transformer 2...15V, outputs galvanically separated from main grid ▪ Full load capacity (5 A), even if direct current is supplied simultaneously 13500-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 51


4 Analytical Chemistry 4.3 Chromatography

P3120400

Chromatographic separation processes: thin layer chromatography

Part of the experimental setup

Principle

Separation chamber, 180x120x50 mm

Chromatographic separation processes are very important for analytical chemistry. Their relatively simple technique and the possibility to separate even the smallest portions of mixtures explain the rapid development of these processes. There are numerous variations of this method. As a result, the optimum chromatographic separation method can be found for nearly every separation task. The method that is described here can be used to demonstrate the fundamental principles and possibilities of this method with relatively simple means. Task Separate a dye mixture by thin-layer chromatography. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Thin-layer chromatography Separation procedure Adsorbent material Stationary phase Mobile phase Capillary action

Function and Application Development vessel for thin-layer chromatography.

Main articles Separation chamber, 180x120x50 mm TLC-foil, silica gel F254, 25 off Ethyl alcohol, absolute 500 ml Methyl red 25 g Capillary holder Micro-capillaries, 2 / 1000 ml, 100 Fuchsine powder 25 g

35010-06 31503-04 30008-50 31574-04 35010-07 35010-08 31320-04

excellence in science 52

1 1 1 1 1 1 1

Equipment and technical data Dimensions: 120 mm×50 mm×180 mm 35010-06


4 Analytical Chemistry 4.3 Chromatography

Chromatographic separation processes: Gas chromatography (with Cobra4)

P3031760

Gas chromatographic separation of a mixture of butane gases.

Principle

Main articles

Chromatographic procedures allow a separation of substance mixtures with the aid of a stationary separation phase and a mobile phase.

Glass jacket Cobra4 Wireless Manager Cobra4 Wireless-Link Software Cobra4 - multi-user licence Immersion thermostat Alpha A, 230 V Control unit gas chromatograph Steel cylinder helium, 2 l, filled

In gas chromatography the mobile phase is a gas. The mobile phase, to which the mixture to be separated is added, transports the substance mixture through the separation column at a constant flow rate. Interactions occur between the mobile phase and the stationary phase.

02615-00 12600-00 12601-00 14550-61 08493-93 36670-99 41776-00

1 1 1 1 1 1 1

The establishment of equilibria between the stationary phase and the different substances (distribution equilibria, adsorption-desorption equilibria) results in different migration rates of the individual components. At the end of the column there is a detector in the form of a thermal conductivity cell, which can detect the different substances on the basis of their differing thermal conductivities. The detector signal is recorded as a funtion of time. The different thermal conductivities of the carrier gas and the substance cause temperature alterations in the electrically heated temperature sensor, which is located in a Wheatstone bridge circuit. The resulting electrical signal is recorded by a plotter as a function of time (chromatogram). Tasks 1. Determine the retention times of different gases and perform a chromatographic material separation of a mixture of butane gases. 2. Separate and identify the components of a two-component mixture consisting of ethanol and ethyl acetate chromatographically. What you can learn about ▪ Chromatography; Chromatogram; Multiplicative distribution ▪ Nernst's law of distribution (number of theoretical trays) ▪ Thermal conductivity detector

Archer J.P. Martin (left) Richard Laurence Millington Synge (right) 1953, Nobel Prize in Chemistry

PHYWE Systeme GmbH & Co. KG · www.phywe.com 53


4 Analytical Chemistry 4.3 Chromatography

P3120300

Column chromatography - separation of leaf pigments

Leaf with green pigments.

Principle In this investigation, a uniformly green raw extract of fresh leaves is first separated into different fractions by means of column chromatography. To do so, the extract is added to a column filled with starch and drawn through the column under slightly reduced pressure (to increase the flow rate of the mobile phase) with ligroin as the eluent. A separation occurs in a clearly recognisable, broad, yellow area and in a narrow, green band. This means that the xanthophylls (yellow) are separated from the chlorophylls (green). If the vacuum is reduced during the separation, the separation is much better, but then separation also takes considerably longer. Each of the separation fractions can be collected individually and characterised by recording their absorption spectra, if necessary, or examined for fluorescence by radiation with UV light. Task Investigate different leaf pigments using column chromatography What you can learn about ▪ Chlorophyll; Column chromatography ▪ Leaf pigments; Xanthophyll

Main articles Frame for complete experiments Secure bottle, 500 ml, 2 x Gl 18/8, 1 x 25/12 Panel for complete experimental setups Column for ion-exchange chromatography Vacuum adaptor, straight, GL25/12 Spring manometer, 0...-1000 mbar

45500-00 34170-01 45510-00 35025-01 35806-15 34170-02

excellence in science 54

1 1 1 1 1 1


5 Spectroscopy

Spectroscopy 5.1 5.2 5.3

X-ray Fluorescence Analysis Nuclear Magnetic Resonance Photometry and Photochemistry

56 59 65

PHYWE Systeme GmbH & Co. KG · www.phywe.com 55


5 Spectroscopy 5.1 X-ray Fluorescence Analysis

P2544701

Qualitative X-ray fluorescence analysis of powder samples

Total representation of the Kα and Kβ fluorescence lines of the elements with an atomic number of 30 < Z < 38.

Principle Various powder samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray fluorescence lines is determined. The elements of the samples are identified by comparing the line energies with the corresponding table values. Tasks 1. Calibrate the semiconductor energy detector with the aid of the characteristic radiation of the tungsten X-ray tube. 2. Record the fluorescence spectra that are produced by the samples. 3. Determine the energy values of the corresponding fluorescence lines and compare the experimental energy values with the corresponding table values in order to identify the powder components.

Best fitting X-ray sets for this experiment: XRE 4.0 X-ray expert set 09110-88 XRM 4.0 X-ray material analysis upgrade set 09160-88

Multi channel analyser

What you can learn about ▪ ▪ ▪ ▪

Bremsstrahlung; Characteristic X-radiation Energy levels; Fluorescent yield Semiconductor energy detectors Multichannel analysers

Main articles XR 4.0 expert unit XR 4.0 X-ray energy detector (XRED) XR 4.0 X-ray goniometer XR 4.0 X-ray plug-in unit W tube Multi channel analyser XR 4.0 X-ray Chemical set for edge absorption measure Software multi channel analyser

09057-99 09058-30 09057-10 09057-80 13727-99 09056-04 14452-61

1 1 1 1 1 1 1

Function and applications The multi channel analyser is for analysing voltage pulses which are proportional to energy and for determining pulse rates and intensities in conjunction with an X-ray detector, alpha detector or gamma detector. The analogue pulses from the detector are shaped by the analyser, digitised and summed per channel according to pulse height. This results in a frequency distribution of detected pulses dependent on the energy of the radiation. 13727-99

excellence in science 56


5 Spectroscopy 5.1 X-ray Fluorescence Analysis

Quantitative X-ray fluorescence analysis of alloyed materials

P2545001

Fluorescence spectrum of constantan, Kα-lines.

Principle Various alloyed materials are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray fluorescence lines is determined. In order to determine the concentration of the alloy constituents, the intensity of their respective fluorescence signals is compared to that of the pure elements.

XR 4.0 X-ray specimen set metals for fluorescence, set of 4 XR 4.0 X-ray specimen set metals for X-ray fluorescence, set of 7

09058-34

1

09058-31

1

Best fitting X-ray sets for this experiment:

Tasks

XRE 4.0 X-ray expert set

1. Calibration of the semiconductor energy detector with the aid of the characteristic radiation of the tungsten X-ray tube. 2. Recording of the fluorescence spectra that are produced by the alloyed samples. 3. Recording of the fluorescence spectra that are produced by the pure metals. 4. Determination of the energy values of the corresponding fluorescence lines. 5. Calculation of the concentration levels of the alloy constituents.

09110-88 XRM 4.0 X-ray material analysis upgrade set 09160-88

XR 4.0 X-ray energy detector (XRED)

What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Bremsstrahlung; Characteristic X-radiation Energy levels; Fluorescent yield; Auger effect Coherent and incoherent photon scattering Absorption of X-rays; Edge absorption Matrix effects; Semiconductor energy detectors Multi channel analysers

Main articles XR 4.0 expert unit XR 4.0 X-ray energy detector (XRED) XR 4.0 X-ray goniometer XR 4.0 X-ray plug-in unit W tube Multi channel analyser

09057-99 09058-30 09057-10 09057-80 13727-99

1 1 1 1 1

Function and Applications With the new X-ray energy detector you can directly determine the energies of single x-ray quanta. 09058-30

PHYWE Systeme GmbH & Co. KG · www.phywe.com 57


5 Spectroscopy 5.1 X-ray Fluorescence Analysis

Quantitative X-ray fluorescence analysis of solutions

P2545101

Principle Various solutions, with known element concentrations, are subjected to polychromatic X-rays. The energy and intensity of the resulting fluorescence radiation of the dissolved elements are analysed with the aid of a semiconductor detector and a multichannel analyser. In order to determine the unknown element concentrations in the solutions, calibration is performed. For this purpose, the known element concentrations of the calibration solution are plotted against the corresponding fluorescence intensities of the dissolved elements.

For more details refer to www.phywe.com

Qualitative X-ray fluorescence spectroscopy of metals - Moseley's law

P2544501

Principle Various metal samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi channel analyser. The energy of the corresponding characteristic X-ray lines is determined, and the resulting Moseley diagram is used to determine the Rydberg frequency and the screening constants.

For more details refer to www.phywe.com

Qualitative X-ray fluorescence analysis of alloyed materials

P2544601

Principle The composition of various alloys is analysed with the aid of polychromatic X-rays. The energy of the characteristic fluorescence lines of the alloy constituents is analysed with the aid of a semiconductor detector and a multichannel analyser. The alloy constituents are identified by comparing the line energies with the corresponding table values.

For more details refer to www.phywe.com

excellence in science 58


5 Spectroscopy 5.2 Nuclear Magnetic Resonance

▪ ▪ ▪ ▪

Compact MRT

Function and Applications The system gives you the unique opportunity of offering training at a real magnetic resonance tomograph (MRT), which is used in almost all fields of science and medicine, directly on site. The training software and the experiment instructions cover all key aspects of the magnetic resonance technology, ranging from the basic principles of nuclear magnetic resonance (NMR) to the complex high-resolution MR imaging (MRI). Thus, students can perform some basic experiments of the MR technology as well as generate, export and analyze numerous high-resolution images in all relevant contrasts. The special option to influence experiments on runtime and to directly visualize the results gives users an unprecedented learning experience. Thereby image artifacts found in clinical MRT can be examined directly in a simple process. The system consists of a "control unit" and a "magnet unit", which differ from other magnetic resonance tomographs only in the size and the fact that they are portable. Benefits ▪ Easy to connect and immediately operative (USB 2.0) ▪ New and numerous education experience ▪ training with clinically relevant measuring procedures ▪ high resolution MR imaging (2D, 3D) ▪ live visualization of data ▪ realtime control of experimental parameters ▪

Practice-oriented training for all fields of science and medicine ▪ T1/T2 measurements ▪ all MR parameters accessible ▪ measure a multitude of samples with a diameter up to one centimeter ▪ software perfectly fits the study purposes ▪ suitable for a wide range of experiments

▪ Literature tailored precisely to the experiments (5 TESS expert experimental units: Basic principles in Nuclear Magnetic Resonance (NMR), Relaxation times in Nuclear Magnetic Resonance, Spatial encoding in Nuclear Magnetic Resonance, Magnetic Resonance Imaging (MRI) I, Magnetic Resonance Imaging (MRI) II) ▪ Possibility to select courses (Basic course, Basic principles, Relaxation, 1D spatial encoding, Imaging I, Imaging II)

Power supply 12 V DC, 2 A Power supply unit (external) 100-240 VAC, 50/60 Hz, 2 A Dimensions (cm) 27 x 9.5 x 14 Weight 2.3 kg

▪ Magnet unit: ▪ High-end gradient system for 2D and 3D images ▪ System frequency 22 MHz ▪ Field strength 500 mT ▪ Field homogenity < 100 ppm ▪ Sample diameter max. 10 mm ▪ Connection of the imaging unit (gradient) RJ45 ▪ Connection of the receiver/transmitter unit BNC ▪ Dimensions (length x width x height, cm) 27 x 25 x 14 ▪ Weight 17.5 kg ▪ Training software: ▪ Languages German/English (other languages on request) ▪ Product license measure MRT ▪ Data formats DICOM, JPEG, CSV, TXT ▪ Media types DVD ▪ Sample set ▪ 5 different samples (water and oil samples each of with 5 and 10 mm diameter, sample with a particular structure) ▪ 1 empty sample tube (10 mm) ▪ ▪ ▪ ▪

Soundbox for a realistic MR-noise Connecting cables (2 x RJ45, 1 x BNC, USB) Sturdy carrying case and shielded flight box for safe transport DVD incl. training software, comprehensive descriptions of the 5 TESS expert experimental units with detailed theoretical background, structured implementation plan, exercises, analyses and many figures clearly arranged, operating instructions, software instructions

Accessories ▪ Required for the experiments: Computer (min. processor 1.6 GHz) with Windows XP (32-Bit)/Vista (32-Bit)/7, USB 2.0 interface, min. 1 GB RAM, min. of 1 GB hard-disk space, 1024 x 758 graphics card (min. 256 MB, compatible with DirectX 9.0), 16-bit color resolution or better ▪ Required for MR-noise: active loudspeakers ▪ Options for experiments: other sample sets or own samples 09500-99

Equipment and technical data The system includes the following components: ▪ Control unit: ▪ Gradient amplifier and transmitter and receiver unit ▪ PC connection USB-B ▪ Connection of the imaging unit (gradient) RJ45 ▪ Connection of the receiver/transmitter unit BNC

Cross-sectional image of a branch.

PHYWE Systeme GmbH & Co. KG · www.phywe.com 59


5 Spectroscopy 5.2 Nuclear Magnetic Resonance

excellence in science 60


5 Spectroscopy 5.2 Nuclear Magnetic Resonance

PHYWE Systeme GmbH & Co. KG · www.phywe.com 61


5 Spectroscopy 5.2 Nuclear Magnetic Resonance

P5942100

Fundamental principles of Nuclear Magnetic Resonance (NMR)

Spin echo signal of an oil sample occuring 10 ms (echo time) after a 90° HF pulse (FID signal is shown). To generate the echo signal a 180° HF pulse has to be switched after half the echo time.

Principle

Main articles

The basic principles concerning the phenomenon of nuclear magnetic resonance (NMR) are demonstrated. Experiments are executed with a MRT training device giving the opportunity to investigate some small probes in the sample chamber. Device control is done with the provided software. Investigations comprise the tuning of the system frequency to the Larmor frequency, the determination of the flip angle of the magnetisation vector, the effects of the substance quantity, the influence of particular magnetic field inhomogeneities, the measurement of a spin echo signal and an averaging procedure to maximise the signal-to-noise ratio. The adjustment of all parameters in these experiments are inevitable to obtain an adequate MR image.

Compact MRT

09500-99

Tasks 1. Tuning of the system frequency to the Larmor frequency. 2. Setting of the HF (High Frequency) pulse duration to determine the flip angle of the magnetisation vector. 3. Effects of the substance quantity on the FID signal (Free Induction Decay) amplitude. 4. Minimising magnetic field inhomogeneities via a superimposed magnetic field (shim). 5. Retrieving a relaxated FID signal via a spin echo flipping nuclear spins by 180°. 6. Improving the signal-to-noise ratio (SNR) of the FID signal. What cou can learn about Nuclear spins; Atomic nuclei with a magnetic moment Precession of nuclear spins; Magnetisation Resonance condition; MR frequency; MR flip angle FID signal (Free Induction Decay); Spin echo Relaxation times (T1: longitudinal magnetisation, T2: transverse magnetisation) ▪ Signal-to-noise ratio ▪ ▪ ▪ ▪ ▪

excellence in science 62

Felix Bloch (left) and Edward Mills Purcell (right) 1952, Nobel Prize in Physics

1


5 Spectroscopy 5.2 Nuclear Magnetic Resonance

Relaxation times in Nuclear Magnetic Resonance

P5942200

Measurement of the T1 relaxation of an oil sample.

Principle The principles of relaxation processes using the MR technology are demonstrated. Experiments are executed with the MRT training device giving the opportunity to investigate some small probes in the sample chamber. Device control is done with the provided software. Investigations comprise the estimation of the relaxation time T1 which is a measure of time for reestablishing the longitudinal magnetization, the measurement of this latter time and the measurement of the relaxation time T2 which is a measure of time for the decline of the transverse magnetization. T1 and T2 are specific to the sample material and thus give important evidence for the composition of the subject of investigation. Tasks 1. Estimation of the relaxation time T1 via two successive 90° HF pulses. 2. Measuring the relaxation time T1 using an automatic software routine. 3. Measuring the relaxation time T2 using an automatic software routine. What cou can learn about ▪ Nuclear spins; Precession of nuclear spins;Resonance condition; MR frequency; MR flip angle ▪ Longitudinal and transverse magnetization; FID signal (Free Induction Decay) ▪ T1/T2 relaxation times; Measuring T1/T2 relaxaion times; Spinlattice relaxation (T1); Spin-spin relaxation (T2); Dephasing

Main articles Compact MRT

09500-99

1

Laboratory Experiments Magnetic Resonace Tomography (MRT)

Description Comprehensive collection of experiments ragarding the magnetic resonance (MR) technology. The manual comprises basic experiments of the MR physics as well as experiments on complex MR imaging (2D and 3D). Experiments are didactically and precisely prepared and convey all relevant information about magnetic resonance tomography. Through questions, answers, evaluations and a comprehensive theory students are guided and are able to learn one of the most important procedures of medical diagnostics with a lot of fun and enjoyment. The software needed to perform the experiments perfectly fits the experimental literature and thus enables an unique learning and teaching experience. For example parameters can be directly varied during a measurement ("on runtime"). The manual is suitable for almost all fields of science. However, basically it is aimed at students with a deep medical background. 01233-02

PHYWE Systeme GmbH & Co. KG · www.phywe.com 63


5 Spectroscopy 5.2 Nuclear Magnetic Resonance

P2511205

Model experiment NMR / ESR

Gyroscope with magnetic axis, ESR model.

Principle

Variable transformer, 25 VAC/ 20 VDC, 12 A

Model experiment for electron spin resonance for clear demonstration of interaction between the magnetic moment of the electron spin with a superimposed direct or alternating magnetic field. What you can learn about ▪ ▪ ▪ ▪

Magnetic field Precession frequency Gyroscope Magnetic induction

Main articles Gyroscope w.magn.axis,ESR model Variable transformer, 25 VAC/ 20 VDC, 12 A Blower 230V/50Hz Coil, 1200 turns Commutator switch On/off switch Iron core, short, laminated

11208-00 13531-93 13770-97 06515-01 06034-03 06034-01 06500-00

1 1 1 4 1 1 2

Function and Application Standard heavy duty power supply unit for low voltage. Supply unit for continuously adjustable DC and AC voltages & 2 frequently required fixed voltages. Equipment and technical data ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

AC output: 0...25 V/12 A DC output: 0...20 V/12 A Max. current (short term): 13 A Add. fixed voltages: 6 V AC / 6 A, 12 V AC / 6 A Max. current (short term): 10 A Max. power: 375 VA Fuses: one 13 A and two 10 A Supply voltage: 230 V AC Dimensions (mm): 230 x 236 x 234

13531-93

excellence in science 64


5 Spectroscopy 5.3 Photometry and Photochemistry

Measurespec spectrometer with cuvette holder and light source

▪ Measurement of emission spectra and absorption spectra ▪ Intuitive "measure" software for controlling the apparatus and recording spectra Cuvette holder: ▪ Robust aluminium case ▪ Long-lived tungsten lamp ▪ Flexible introduction of light to be investigated by means of optical fibres ▪ Universal power supply via plug-in transformer ▪ Measurement of absorption spectra, fluorescence spectra, reaction kinetics Equipment and technical data Spectrometer: ▪ ▪ ▪ ▪ ▪ ▪ ▪

Supplied with software and optical fibres Range of wavelengths: 350...850 nm Detector: silicon CCD array Resolution: 4 nm Connection to computer: USB Optical fibre connection: SMA 905 Dimensions (mm): 170 x 126 x 55

Cuvette holder: ▪ ▪ ▪ ▪ ▪ ▪ ▪

Supplied with plug-in power supply and optical fibres Type of lamp: tungsten (lifetime approx. 2000 hours) Optical fibres: 50 µm x 2 m 2 optical fibre connectors: SMA 905 Size of cuvettes: 1 cm x 1 cm Power supply: 100 ... 240 V / 50 ... 60 Hz Dimensions (mm): 95 x 51 x 46

Accessories Function and Applications

Matching cuvettes:

This set consisting of a Measurespec spectrometer (35610-00) and a cuvette holder and light source for the Measurespec (35610-99) makes it possible to record both emission and absorption spectra.

▪ Cuvettes for spectral photometer, optical glass, 12 x 12 x 45 mm, set of 2 (35664-02) ▪ Polystyrene macro-cuvette, 12 x 12 x 44 mm, 4 ml, set of 100 (35663-10)

The light to be investigated is guided by optical fibres to a grid fixed inside the spectrometer, which disperses it into its spectral colours. The spectrum is recorded with the aid of a CCD array, which records the entire spectrum at once, making it possible to reliably record rapid changes in the spectrum itself. The spectra can be displayed and stored by means of the supplied software with its versatile functionality.

35610-88

The spectrometer is connected to a PC via a USB port, which also suffices to supply power to the spectrometer, so that no additional supply is needed. The cuvette holder holds standard cuvettes measuring 1 cm x 1 cm. The built-in light source makes it possible to record absorption spectra for solutions. The rapid measuring rate of the spectrometer even allows the speed of reactions involving changes in colour to be measured (reaction kinetics). Light having passed through the cuvette is guided into the spectrometer via optical fibre. Fibres for fluorescence measurements can also be attached at 90° to the path of the incident light. Benefits Spectrometer:

Representation of a spectrum in "measureSpec"

▪ Robust aluminium case ▪ Rapid measurement of full spectral range ▪ Flexible introduction of light to be investigated by means of optical fibres ▪ No additional power supply required

PHYWE Systeme GmbH & Co. KG · www.phywe.com 65


5 Spectroscopy 5.3 Photometry and Photochemistry

Absorption of light (UV-VIS spectroscopy)

P3070101 Principle The structures of molecules are not changed by their chemical environment in the gas phase. In contrast to this, on transition to the condensed phase, in dilute solution, the solvent changes the binding state of the dissolved substance. One of the way this influence makes itself shown is in the elctron spectrum (solvatochromatic shift).

For more details refer to www.phywe.com

Excitation of molecules

P3070301 Principle The position of the longest wavelength π - π* -absorption band in the UV-VIS spectrum of organic compounds which have chromophoric systems can be approximately calculated by various methods. For dyes with extended conjugated π-systems, the model of the electron in an unidimensional potential box (confinement region) supplies results that agree sufficiently well with experimental results.

For more details refer to www.phywe.com

Absorption spectra and pKa values of p-methoxyphenol

P3070401

Principle For weak acids HA, the position of the Ka and pKa values that characterise the dissociation equilibrium in the ground state can be determined from photometric measurements in solutions having different pH values. Further to this, the pKa* value for the excited state is accessible from the spectrophotometric data.

For more details refer to www.phywe.com

excellence in science 66


6 Physical Chemistry

Physical Chemistry 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8

Gas Laws Kinetic Theory Viscosity Thermochemistry / Calorimetry Chemical Kinetics Electro Chemistry Phase Equilibrium Atomic Structures and Properties

68 75 77 80 93 101 117 125

PHYWE Systeme GmbH & Co. KG · www.phywe.com 67


6 Physical Chemistry 6.1 Gas Laws

excellence in science 68


6 Physical Chemistry 6.1 Gas Laws

PHYWE Systeme GmbH & Co. KG · www.phywe.com 69


6 Physical Chemistry 6.1 Gas Laws

P3011160

Gay-Lussac's law (with Cobra4)

Volume in dependence on temperature.

Principle The state of a gas is determined by temperature, pressure and amount of substance. For the limiting case of ideal gases, these state variables are linked via the ideal gas law. For a change of state under isobaric conditions this equation converts Gay-Lussac's first law. Tasks 1. Experimentally investigate the validity of Gay-Lussac's law for a constant amount of gas (air). 2. Calculate the universal gas constant and the thermal coefficient of expansion from the relationship obtained. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪

Pressure Temperature Volume Coefficient of thermal expansion Ideal gas law Universal gas constant Gay-Lussac's law

Main articles Set Gas laws with glass jacket system and Cobra4 Cobra4 Remote-Link

43020-00 12602-00

1 1 Johannes Diderik van der Waals 1910, Nobel Prize in Physics

excellence in science 70


6 Physical Chemistry 6.1 Gas Laws

Amontons' law (with Cobra4)

P3011260

Dependence of the pressure on the temperature under isochoric conditions.

Principle

Cobra4 Remote-Link

The state of a gas is determined by temperature, pressure and amount of substance. For the limiting case of ideal gases, these state variables are linked via the ideal gas law. For a change of state under isochoric conditions this equation becomes Amontons' law. Tasks 1. Experimentally investigate whether Amontons' law is valid for a constant amount of gas (air). 2. From the resulting relationship calculate the universal gas constant and thermal coefficient of tension. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪

Pressure Temperature Volume Thermal tension coefficient Ideal gas law Universal gas constant Charles's (Amontons') law

Function and Applications The Cobra4 Remote-Link is used to control the measuring value recording of an experiment constructed using a radiobased Cobra4 network.

Main articles Set Gas laws with glass jacket system and Cobra4 Cobra4 Remote-Link

43020-00 12602-00

1 1

Benefits ▪ The measuring value recording start and stop command is transmitted by radio to the Cobra4 Wireless Manager on the PC. ▪ Optimum application, e.g. in student experiments, free fall with an acceleration sensor etc. . 12602-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 71


6 Physical Chemistry 6.1 Gas Laws

P3011360

Boyle's law (with Cobra4)

Correlation between volume and pressure under isothermic conditions.

Principle The state of a gas is determined by temperature, pressure and amount of substance. For the limiting case of ideal gases, these state variables are linked via the ideal gas law. In the case of isothermal process control this equation converts Boyle and Mariotte's law.

Set Gas laws with glass jacket system and Cobra4

Tasks 1. Experimentally investigate the validity of Boyle and Mariotte's law for a constant amount of gas (air). 2. From the resulting relationship calculate the universal gas constant. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪

Pressure Temperature Volume Cubic compressibility coefficient Ideal gas law Universal gas constant Boyle and Mariotte's law

Function and Applications Complete device compilation for a comfortable way to derive the ideal gas laws experimentally with help of the Cobra4 Senor-Unit Thermodynamics and the glass jacket system. Equipment and technical data

Main articles

The set consists of:

Set Gas laws with glass jacket system and Cobra4 Cobra4 Remote-Link

43020-00 12602-00

1 1

▪ 1 Cobra4 Wireless Manager; 1 Cobra4 Wireless-Link. ▪ 1 Cobra4 Sensor-Unit Thermodynamics, pressure absolute 2 bar and 2 x temperature. ▪ 1 Software measure Cobra4, single user and school licence. ▪ 1 Glass jacket; 1 Gas syringe 100 ml; 1 Heater for Glass jacket. ▪ 1 Immersion probe NiCr-Ni, -50...1000 °C. ▪ All necessary support materials and all the other small hardware items to be able to carry out the measurements for the gas laws. 43020-00

excellence in science 72


6 Physical Chemistry 6.1 Gas Laws

Law of integer ratio of volumes according to Gay-Lussac's law of chemical volumes

P3031401

Dependence of the final volume reduced to room temperature from the initial volume of hydrogen-oxygen mixtures of different composition.

Principle According to Gay-Lussac's law of chemical volumes, gases react in volume ratios which are whole numbers. These values can be volumetrically determined.

Related Experiment Thermal equation of state and critical point P2320400

Task Determine the volume ratio for the conversion of hydrogen and oxygen to water experimentally by burning gas mixtures of different compositions and measuring the resulting gas volume.

High voltage supply unit, 0-10 kV

What you can learn about ▪ ▪ ▪ ▪ ▪

Law of constant proportions Avogadro's law Gay-Lussac's law of chemical volumes General equation of state for ideal gases Gay-Lussac's first law

Main articles High voltage supply unit, 0-10 kV Slow eudiometer Glass jacket Steel cylinder hydrogen, 2 l, full Heating apparatus for glass jacket system Steel cylinder oxygen, 2 l, filled Power regulator

13670-93 02612-00 02615-00 41775-00 32246-93 41778-00 32288-93

1 1 1 1 1 1 1

Function and Applications For electrostatic experiments and for operation of spectral and gas discharge tubes. Equipment and technical data ▪ It supplies 3 continuously variable DC voltages isolated from earth and ground. ▪ Two of the voltages are connected in series 0-5 kV DC = total of 0 -10 kV DC. 13670-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 73


6 Physical Chemistry 6.1 Gas Laws

Handbook Glass Jacket System

Gay-Lussac's law of volumes P1223551 Avogadro's law P1223651 The empirical formula of methane, ethane and propane P1223751 Determination of the heat of formation of water P1223800 Determination of the heat of formation of CO2 and CO and Hess's law P1223900 Determination of the heating values of solid and gaseous fuels in a horizontal calorimeter P1224051 Determination of the calorific value of food stuffs P1224100 Determination of the heating values of liquids in a vertical calorimeter P1224251 Determination of the heating value of fuel oil and of the calorific value of olive oil P1224300 Chromatographic separation processes: Gas chromatography P1224451

Article no. 01196-12 Description Comprehensive set of 17 experiments using the glass jacket set for various uses.

01196-12

Topics ▪ ▪ ▪ ▪ ▪ ▪

Steam distillation P1224551

Gas laws Gas reactions Determining molecular mass Calorimetry Gas chromatography Distillation of steam

This system consists of a glass jacket, special inserts and accessories. It was mainly developed for experiments with gases and can be used at school for teaching physics, chemistry and biology. ▪ Demonstrative and transparent ▪ Versatile and easily assembled ▪ Water bath for accurate measurements This documentation contains the following experiments: Gay-Lussac's law P1222900 Charles's (Amontons') law P1223000 The Boyle-Mariotte law P1223100 The gas laws of Boyle-Mariotte, Gay-Lussac and Charles (Amontons) P1223200 Determination of molar masses with the vapour density method P1223301 Law of integer ratio of volumes P1223400

excellence in science 74

Steam distillation - P3031251


6 Physical Chemistry 6.2 Kinetic Theory

Maxwellian velocity distribution

P2320300

Experimental and theoretical velocity distribution in the model experiment.

Principle

Kinetic gas theory apparatus

By means of the model apparatus for kinetic theory of gases the motion of gas molecules is simulated and the velocities determined by registration of the throw distance of the glass balls. This velocity distribution is compared to the theoretical MaxwellBoltzmann equation. Tasks 1. Measure the velocity distribution of the "model gas". 2. Compare the result to theoretical behaviour as described by the Maxwell-Boltzmann distribution. 3. Discuss the results. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Kinetic theory of gases Temperature Gas-molecules Model kinetic energy Average velocity Velocity distribution

Function and Applications Kinetic gas theory apparatus with vertical chamber and built in motor. Equipment and technical data

Main articles Kinetic gas theory apparatus Digital stroboscope Receiver with recording chamber Power supply variable 15 VAC/ 12 VDC/ 5 A Tripod base PHYWE Stopwatch, digital, 1/100 s

09060-00 21809-93 09061-00 13530-93 02002-55 03071-01

1 1 1 1 2 1

▪ Chamber (mm) 60 x 20 x 180 ▪ Motor supply 12 VDC /20 W 09060-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 75


6 Physical Chemistry 6.2 Kinetic Theory

P3010301

Diffusion in gases: The diffusion coefficient of bromine in air

Diffusion coefficient of Fick's first law.

Principle Diffusion arises from the flow of matter down a concentration gradient. In the evaporation method, a stationary concentration gradient is achieved in which the concentration decreases linearly with distance. Under these conditions the diffusion coefficient of the diffusing substance may be calculated by a direct application of Fick's first law of diffusion. Task Measure the diffusion coefficient of bromine in air using an evaporation method. What you can learn about ▪ ▪ ▪ ▪ ▪

Kinetic theory of gases Transport properties Fick's laws of diffusion Self and mutual diffusion coefficients Alternative techniques e.g. Loschmidt's method

Main articles Sec.bottle500ml,2xGl18/8,1x25/12 Tube connector, T-shaped, IGJ29 Spring manometer, 0...-1000 mbar Bromine 100 ml Gas-wash.bottle w.frit, IGJ.29/32 Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

34170-01 35859-00 34170-02 30046-10 36691-01

1 1 1 1 1

49224-88

1

excellence in science 76


6 Physical Chemistry 6.3 Viscosity

Viscosity of Newtonian and non-Newtonian liquids (rotary viscometer)

P2140300

Moment of rotation as a function of the frequency for a Newtonian liquid Glycerine (+), Liquid paraffin(o).

Principle The viscosity of liquids can be determined with a rotation viscometer, in which a motor with variable rotation speed drives a cylinder immersed in the liquid to be investigated with a spiral spring. The viscosity of the liquid generates a moment of rotation at the cylinder which can be measured with the aid of the torsion of the spiral spring and read on a scale. Tasks 1. Determine the gradient of the rotational velocity as a function of the torsional shearing stress for two Newtonian liquids (glycerine, liquid paraffin). 2. Investigate the temperature dependence of the viscosity of Castor oil and glycerine. 3. Determine the flow curve for a non Newtonian liquid (chocolate). What you can learn about ▪ Shear stress; Velocity gradient; Internal friction ▪ Viscosity; Plasticity

Main articles Rotary viscometer, 15 - 2,000,000 mPas, 110...240 V Magnetic stirrer MR Hei-Standard Electronic temperature controller EKT Hei-Con Glycerol 250 ml Castor oil 250 ml Liquid paraffin 250 ml Acetone, chem.pure 250 ml

18223-99 35750-93 35750-01 30084-25 31799-27 30180-25 30004-25

1 1 1 2 2 1 3

Rotary viscometer, 15 - 2,000,000 mPas, 110...240 V Function and Applications Classic rotational viscometer for the viscosity determination according to ISO2555 ("Brookfield method") and many ASTM standards. Benefits ▪ The results are 100% compatible to the Brookfield method. ▪ All results (viscosity, torque in %, speed, spindle) are displayed on the built-in display. ▪ Multilanguage display: English, French, German, Spanish, Italian, Japanese, Portuguese, Dutch, Polish, Catalan. ▪ Visual and acoustic signals at critical measuring conditions. ▪ Warning, if the device is used outside of the permissible measuring ranges. ▪ Digital speed control with "built-in"accuracy through stepping motor. ▪ Touchless, optoelectronic torque measuring system with high accuracy and without wear. ▪ It is supllied as a complete measuring unit consisting of the basic instrument with stand, set of spindles with a storage rack in a stable case. 18223-99

PHYWE Systeme GmbH & Co. KG · www.phywe.com 77


6 Physical Chemistry 6.3 Viscosity

P2140400

Viscosity measurement with the falling ball viscometer

Temperature dependence of the dynamic viscosity of water (o) and methanol (+), respectively.

Principle

Falling ball viscometer

Due to internal friction among their particles, liquids and gases have different viscosities. The viscosity, a function of the substance's structure and its temperature, can be experimentally determined, for example, by measuring the rate of fall of a ball in a tube filled with the liquid to be investigated. Tasks Measure the viscosity 1. of methanol-water mixtures of various composition at a constant temperature, 2. of water as a function of the temperature and 3. of methanol as a function of temperature. From the temperature dependence of the viscosity, calculate the energy barriers for the displace ability of water and methanol. What you can learn about ▪ ▪ ▪ ▪

Newtonian liquid Stokes law; Fluidity Dynamic and kinematic viscosity Viscosity measurements

Function and Applications Falling ball viscometer. Equipment and technical data

Main articles Falling ball viscometer Immersion thermostat Alpha A, 230 V Thermometer, 24...+ 51 ºC, for 18220.00 Bath for thermostat, makrolon External circulation set f. thermostat Alpha A Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

18220-00 08493-93 18220-02 08487-02 08493-02

1 1 1 1 1

49224-88

1

excellence in science 78

▪ ▪ ▪ ▪ ▪

Thermometer Diameter of the fall tube: 15.95 mm Initiable fall times: 25...300 s Fall distance: 100 mm 6 balls

18220-00


6 Physical Chemistry 6.3 Viscosity

Determining the molecular weight of a polymer from intrinsic viscosity measurements

P3010601

Plot used to determine the intrinsic vicosity h. Data for polystyrene in toluene at 25.0°C.

Principle The viscosity of a liquid is effectively determined by the strength of the intermolecular attractive forces. In the case of solutions, the viscosity of the solvent can alter significantly depending on the type and concentration of the solute. Due to their size, macromolecules have a very considerable impact on the viscosity of the solvent. Viscosity measurements can be used to estimate the mean molecular mass of a macromolecule if something is known about its conformation.

External circulation set f. thermostat Alpha A Retort stand, h = 750 mm Water jet pump, plastic Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

08493-02 37694-00 02728-00

1 1 1

49221-88

1

Tasks 1. Use a thermostatted capillary viscometer to measure the viscosities of solutions of polystyrene in toluene over a range of five polymer concentrations. 2. Determine the instrinsic viscosity and from that estimate the molecular weight (relative molecular mass) of the polymer in this solution. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Viscosity of liquids Ostwald capillary viscometer Poiseuilles's equation Macromolecules Mass average and number average molecular weights The Mark-Houwink equation Alternative techniques e.g. osmosis Sedimentation (ultracentrifuge methods) Light scattering

Main articles Immersion thermostat Alpha A, 230 V Ubbelohde viscosimeter, 0.4 mm Bath for thermostat, makrolon

08493-93 03102-03 08487-02

1 1 1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 79


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3020260

Adiabatic coefficient of gases - Flammersfeld oscillator

Sample results for the adiabatic coefficients. Experimental conditions: ten measurements, each of about n = 300 oscillations.

Principle

Light barrier, compact

A mass oscillates on a volume of gas in a precision glass tube. The oscillations maintained by leading escaping gas back into the system. The adiabatic coefficient of various gases is determined from the periodic time of the oscillation. Task Determine the adiabatic coefficient of air, nitrogen and carbon dioxide (and also of argon, if available) from the periodic time of the oscillation T of the mass on the volume V of gas. What you can learn about ▪ ▪ ▪ ▪

Equation of adiabatic change of state Polytropic equation Rüchardt's experiment Thermal capacity of gases Function and Applications

Main articles Steel cylinder,CO2, 10l, full Steel cylinder,nitrogen,10l, full Light barrier with counter Gas oscillator, Flammersfeld Sliding weight balance, Kern 150-23, 101 g / 0.01 g Reducing valve for CO2 / He Reducing valve f. nitrogen

41761-00 41763-00 11207-30 04368-00

1 1 1 1

44012-01 33481-00 33483-00

1 1 1

Universal fork-type light barrier to measure short and long shadowing periods. Benefits ▪ An incremental wheel with a string groove which can be attached to the fork of the light barrier allows to measure paths by counting the ribs of the incremental wheel. ▪ Areas of application: track experiments, freefall, pendulum experiments, leaf spring oscillations, drop counters, volumetric measurements concerning the gas laws. Equipment and technical data ▪ Dimensions: 40 x 40 mm ▪ Supply voltage: 5 V 11207-20

excellence in science 80


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

Heat capacity of gases

P2320201

Pressure change p as a function of the heat-up time t. U = 4.59 V, I = 0.43 A.

Principle

Universal Counter

Heat is added to a gas in a glass vessel by an electric heater which is switched on briefly. The temperature increase results in a pressure increase, which is measured with a manometer. Under isobaric conditions a temperature increase results in a volume dilatation, which can be read from a gas syringe. The molar heat capacities Cv and Cp are calculated from the pressure or volume change. Task Determine the molar heat capacities of air at constant volume Cv and at constant pressure Cp. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Equation of state for ideal gases First law of thermodynamics Universal gas constant Degree of freedom Mole volumes Isobars Isotherms Isochors and adiabatic changes of slate

The universal counter is used for measuring time, frequency, pulse rates, pulse counting, periodic times, speeds and velocities. Benefits

Main articles Universal Counter Precision manometer Weather station, wireless Mariotte flask, 10 l Tripod base PHYWE Digital multimeter 2010 Two-way switch, single pole

Function and Applications

13601-99 03091-00 04854-00 02629-00 02002-55 07128-00 06030-00

1 1 1 1 1 2 1

▪ The device has all the qualities that are expected of a modern universal counter and is also equiped with a number of technical specifics of how it specifically arise from the requirements of science teaching practice. ▪ For the scientifically correct representation of each measurement is shown in principle with the associated unit. With the overflow of the display is automatically switched into the next area. ▪ Before the measurement starts it can be manually adjusted to a maximum of 6 decades defined range, e.g. to suppress is not physically meaningful digits on the display. ▪ A special jack for direct connection of a GM counter tube is available for radioactivity experiments. The required voltage can be changed manually to determine the characteristics of a counter tube too. 13601-99

PHYWE Systeme GmbH & Co. KG · www.phywe.com 81


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3020411

Determination of the enthalpy of vaporisation of liquids (with Cobra3)

Temperature-time curve of the vaporisation of diethyl ether and determining the heat capacity of the system.

Principle The vaporisation of a liquid occurs with heat absorption. To determine the enthalpy of vaporisation, a known mass of the liquid which is to be investigated is vaporised in a special vaporisation vessel in a current of air. The quantity of heat absorbed, which corresponds to the enthalpy of vaporisation, can be calorimetrically determined.

Cobra4 Experiment - available 2013 Determination of the enthalpy of vaporisation of liquids (with Cobra4) P3020460

Tasks 1. Determine the molar enthalpy of vaporisation of diethyl ether and methanol. 2. Calculate the molar entropies of vaporisation and discuss the results under consideration of Trouton's rule.

Work and power meter

What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Enthalpy of vaporisation Enthalpy of condensation Enthalpy of sublimation Vapour pressure; Entropy of vaporization Clausius-Clapeyron equation; Trouton's rule Law of thermodynamics; Calorimetry

Main articles

Function and Applications

Set calorimetry, 230 V Cobra3 Data acquisition set for set calorimetry Evaporation vessel for calorimeter Set of Precisionl Balance Sartorius CPA 6202S and measure software, 230 V Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

43030-88

1

43030-30 04405-00

1 1

49226-88

1

49224-88

1

For AC and DC circuits Equipment and technical data ▪ Two 4-digit, 20 mm LED-displays; Display 1 for real and apparent power,current, voltage, phase difference and freqency ▪ Display 2 for energy and time;Selector for serial display of all units; LED-Status-display and automactic range selection; Power: max. 2400 W; Resolution: max. 0.001 W ▪ Voltage: 0-30V AC/DC, 0-240 V; eff- Current: 0...10A AC/DC 13715-93

excellence in science 82


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

Partial molar volumes

P3020501

Dependence of the mean molar mixing volumes on the composition of different ethanol/water mixtures.

Principle

Immersion thermostat Alpha A, 230 V

Due to intermolecular interactions, the total volume measured when two real liquids (e.g. ethanol and water) are mixed deviates from the total volume calculated from the individual volumes of the two liquids (volume contraction). To describe this non-ideal behaviour in the mixing phase, one defines partial molar quantities which are dependent on the composition of the system. The values of these can be experimentally determined. Tasks 1. Measure the densities of different ethanol-water mixtures of specified composition at 20 °C with pycnometers. 2. Calculate the real volumes and the mean molar mixing volumes of the investigated ethanol-water mixtures and also the partial molar volumes of each liquid for selected compositions. 3. Compare them with the molar volumes of the pure substances at 20 °C.

Immersion circulator with simple, reliable options for obtaining consistent results. Compact unit can be combined with any existing baths up to 25 mm wall thickness.

What you can learn about ▪ ▪ ▪ ▪

Principles of thermodynamics Ideal and non-ideal behaviour of gases and liquids Volume contraction Molar and partial molar quantities

Benefits

Main articles Immersion thermostat Alpha A, 230 V Bath for thermostat, Makrolon External circulation set f. thermostat Alpha A Pycnometer, calibrated, 25 ml Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

Function and Applications

08493-93 08487-02 08493-02 03023-00

1 1 1 9

49224-88

1

Wide temperature range to meet application needs. Digital settings for simple operation. Strong pump for high temperature conformity. To be used with water as heat transfer liquid. Screw clamp for bath walls up to 25 mm. Robust design using high grade stainless steel and temperature resistant polymer. ▪ Wear-free; integrated overload protection. ▪ ▪ ▪ ▪ ▪ ▪

08493-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 83


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3020611

Determination of the mixing enthalpy of binary fluid mixtures (with Cobra3)

Temperature-time curve of the mixing of two miscible fluids and determining the heat capacity of the system.

Principle When two miscible liquids are mixed, a positive or negative heat effect occurs, which is caused by the interactions between the molecules. This heat effect is dependent on the mixing ratio. The integral mixing enthalpy and the differential molar mixing enthalpy can be determined by calorimetric measurements of the heat of reaction.

Cobra4 Experiment - available 2013 Determination of the mixing enthalpy of binary fluid mixtures (with Cobra4) P3020660

Tasks 1. Measure the integral mixing enthalpy of seven different water-acetone mixtures. 2. Plot the molar integral mixing enthalpy versus the quantity of substance (mole fraction) and determine the molar mixing enthalpy. 3. Discuss the results on the basis of the interactions in the mixture.

Set calorimetry, 230 V

What you can learn about ▪ ▪ ▪ ▪ ▪

Differential molar mixing enthalpy Real and ideal behaviour Integral molar mixing enthalpy Fundamental principles of thermodynamics Calorimetry

Main articles Set calorimetry, 230 V Cobra3 Data acquisition set for set calorimetry Immersion thermostat Alpha A, 230 V Bath for thermostat, Makrolon Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

43030-88

1

Function and Applications

43030-30 08493-93 08487-02

1 1 1

With this setup a great number of measurements to heat capacities, reaction enthalpies, solution enthalpies, neutralisation enthalpies, melting enthalpies and enthalpies of mixtures can be carried out.

49226-88

1

43030-88

excellence in science 84


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

Determination of the hydration enthalpy of an electrolyte (solution enthalpy) (with Cobra3)

P3020711

Temperature-time curves of solutions of anhydrous and hydrated copper sulphate and determining the heat capacity of the system.

Principle When a solid electrolyte dissolves in water, a positive or negative heat effect occurs as a result of the destruction of the crystal lattice and the formation of hydrated ions. The enthalpy of hydration of copper sulphate can be calculated from the different heats of reaction measured when anhydrous and hydrated copper sulphate are separately dissolved in water.

Related Experiment Determination of the enthalpy of neutralisation (with Cobra3) P3020811

Tasks 1. Record temperature-time curves for the dissolution of anhydrous copper(II) sulphate and hydrated copper(II) sulphate in water. 2. Calculate the hydration enthalpy of anhydrous copper(II) sulphate.

Determination of the hydration enthalpy of an electrolyte (solution enthalpy) (with Cobra4)

What you can learn about

P3020760

▪ ▪ ▪ ▪ ▪

Cobra4 Experiment - available 2013

Integral enthalpy of solution Hess' law Lattice energy Ion solvation Calorimetry

Main articles Set calorimetry, 230 V Cobra3 Data acquisition set for set calorimetry Desiccator, wertex, diam. 150 mm Butane burner, Labogaz 206 type Silica gel, orange, granular, 500 g Copper-II sulphate, anhydr. 250 g Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

43030-88

1

43030-30 34126-00 32178-00 30224-50 31495-25

1 1 1 1 1

49226-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 85


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3020911

Determination of the melting enthalpy of a pure substance (with Cobra3)

Temperature-time curve for the melting process of dioxan and determining the heat capacity of the system.

Principle When a solid melts, energy is required for the destruction of the crystal lattice. A substance whose melting point lies slightly below room temperature is first cooled until it solidifies and then melted in a calorimeter. The melting enthalpy is calculated from the decrease in temperature due to the melting process which is measured in the calorimeter. Tasks 1. Take a temperature-time-diagram for the melting process of dioxan. 2. Calculate the melting enthalpy and entropy of 1,4-dioxan. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪

Heat capacity Melting point Latent heat Calorimetry Gibbs' phase rule Enthalpy of sublimation Enthalpy of vaporisation

Main articles Set calorimetry, 230 V Cobra3 Data acquisition set for set calorimetry Dewar vessel,500 ml Dioxane 1000 ml Separator for magnetic bars Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V

43030-88

1

43030-30 33006-00 31266-70 35680-03

1 1 1 1

49226-88

1

excellence in science 86

Cobra4 Experiment - available 2013 Determination of the melting enthalpy of a pure substance (with Cobra4) P3020960


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

Determination of the enthalpy of combustion with a calorimetric bomb

P3021401

Determining the corrected temperature difference.

Principle

Calorimetric bomb

The bomb calorimeter is used to completely burn substances in an excess of oxygen. The heat of combustion released is absorbed by the calorimetric vessel in which the bomb is immersed, and results in a temperature increase ΔT. The heat capacity of the system is first determined by adding a defined amount of heat from the combustion of benzoic acid. The combustion of the naphthalene is subsequently performed under the same conditions. Tasks 1. Determine the enthalpy of combustion of naphtalene using a bomb calorimeter. 2. Calculate the enthalpy of formation of naphthalene from the enthalpy of combusting unsing Hess' law. What you can learn about ▪ ▪ ▪ ▪ ▪

First law of thermodynamics Hess' law of constant heat summation Enthalpy of combustion Enthalpy of formation Heat capacity

Function and Applications Calorimetric bomb for the quantitative determination of combustion heat of liquid and solid organic substances under high oxygen pressure. Equipment and technical data

Main articles Calorimetric bomb Temperature meter digital, 4-2 Power supply, universal Magnetic stirrer MR Hei-Standard Calorimeter, transparent, volume appr. 1200 ml Set of Precision Balance Sartorius CPA 6202S and measure software, 230 V Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

Stainless steel body Contents approx. 120 ml Stainless steel lid with valve Oxygen filling connection Max. oxygen pressure 25 bar Ignition wire

04403-00 13617-93 13500-93 35750-93

1 1 1 1

▪ ▪ ▪ ▪ ▪ ▪

04402-00

1

04403-00

49226-88

1

49224-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 87


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3021501

Determination of the heat of formation of water

General equation of state for ideal gases.

Principle Standard molar enthalpies of formation ΔBHΦ are important compiled thermodynamics tabulation quantities for calculating standard enthalpies of reaction for any arbitrary reaction. They are defined as the heat of reaction occurring in the direct formation of one mole of the pertinent pure substance from the stable pure elements at constant pressure. For spontaneous and quantitative formation reactions, e.g. the conversion of hydrogen and oxygen to water, standard enthalpies of formation can be measured directly using calorimetry.

Glass jacket

Tasks Determine the enthalpy of formation of water by burning 100 ml H2 in a closed glass jacket calorimeter.

Function and Applications

What you can learn about

Benefits

▪ ▪ ▪ ▪ ▪

First law of thermodynamics Thermochemistry Calorimetry Enthalpy of formation Enthalpy of reaction

The cylinder is made of DURAN 50 ®, which gave him an extreme heat resistance, high thermal shock resistance, mechanical strength and excellent chemical resistance. Equipment and technical data

Main articles High voltage supply unit, 0-10 kV Glass jacket Steel cylinder hydrogen, 2 l, full Lid for calorimeter insert Steel cylinder oxygen, 2 l, filled Calorimeter insert for glass jacket Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13670-93 02615-00 41775-00 02615-02 41778-00 02615-01

1 1 1 1 1 1

49224-88

1

excellence in science 88

Glass jacket, used as cooling or heating mantle.

Cylindrical glasstube with screw closures for different inserts Length: 205 mm Outer diameter: 75 mm Connecting nut and gasket for flanging cylindrical inserts with an outer diameter of 36 mm watertight and airtight ▪ 1 Flange with ring nut ▪ ▪ ▪ ▪

02615-00


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

Determination of the heat of formation for CO2 and CO (Hess' law)

P3021601

Experimental setup for preparing the carbon monoxide.

Principle Φ

The standard molar enthalpies of formation ΔBH are important compiled thermodynamic tabulation quantities for calculating standard enthalpies of reaction for any arbitrary reaction. They are defined as the heat of reaction occurring in the direct formation of one mole of the pertinet pure substance from the stable pure elements at constant pressure. For spontaneous and quantitative formation reactions, e.g. the conversion of carbon and oxygen to CO2, standard enthalpies of formation can be measured directly using calorimetry. Alternativly, they can be calculated from known entahlpies of reaction using Hess' law.

Weather monitor, 6 lines LCD Reducing valve for oxygen Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

87997-10 33482-00

1 1

49224-88

1

Gasometer 1000 ml

Tasks 1. Determine the enthalpies of reaction for the combustion of carbon and carbon monoxide calometrically. 2. Use the experimentally determined enthalpies and Hess' law to calculate the enthalpies of formation of CO and CO2. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

First law of thermodynamics Thermochemistry Calorimetry Enthalpy of formation Enthalpy of reaction Hess' law

Function and Applications Gasometer. Equipment and technical data

Main articles Gasometer 1000 ml Glass jacket Steel cylinder oxygen, 2 l, filled Calorimeter insert for glass jacket

40461-00 02615-00 41778-00 02615-01

1 1 1 1

▪ Content 1000 ml ▪ Adjustable outer scale ▪ Readability 10 ml 40461-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 89


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3021701

Determination of the heating value of fuel oil and of the calorific value of olive oil

Equation to calculate the calorific value (of fuels) and the gross calorific value (of foodstuffs).

Principle

Calorimeter insert for glass jacket

The heat of reaction generated during the complete combustion of 1000 g of solid or liquid fuel is known as the calorific value H. In the case of complete combustion of nutritional fats, the gross calorific value can also be determined. In order to ensure complete combustion, the reaction takes place under oxygen. The heat generated during the combustion of a specific amount of fuel is absorbed by a glass jacket calorimeter of known heat capacity. The calorific value of the test substance can be calculated from the temperature increase in the calorimeter. Task Determine the calorific value of heating oil and the gross calorific value of olive oil.

Function and Applications

What you can learn about

Calorimeter insert for glass jacket.

▪ ▪ ▪ ▪

Benefits

Heat of reaction Heat of combustion Enthalpy of combustion First law of thermodynamics

▪ It can determine calorific values, heat of combustion and enthalpies of gaseous, liquid and solid substances. ▪ Combustion chamber with a circular cross section, rotating double helix as a heat exchanger

Main articles Glass jacket Steel cylinder oxygen, 2 l, filled Calorimeter insert for glass jacket Reducing valve for oxygen Table stand for 2 l steel cylinders Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

02615-00 41778-00 02615-01 33482-00 41774-00

1 1 1 1 1

49224-88

1

excellence in science 90

Equipment and technical data ▪ ▪ ▪ ▪ ▪

Total length: 280 mm Combustion chamber length: 90 mm Outer combustion chamber: 36 mm Length of the approach pipe: 70 mm OD approach pipe: 8 mm

02615-01


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

Thermal expansion in solids and liquids

P2310100

Relationship between length l and temperature, for a) aluminium, b) brass, c) copper, d) steel, e) duran glass, f) quartz glass (lo = 600 mm).

Principle

Dilatometer with clock gauge

The volume expansion of liquids and the linear expansion various materials is determined as a function of temperature. Tasks 1. To determine the volume expansion of ethyl acetate (C4H8O2), methylated spirit, olive oil, glycerol and water as a function of temperature, using the pycnometer. 2. To determine the linear expansion of brass, iron, copper, aluminium, duran glass and quartz glass as a function of temperature using a dilatometer. 3. To investigate the relationship between change in length and overall length in the case of aluminium. Function and Applications

What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Dilatometer with clock gauge on baseplate 730x50x25 mm for the quantitative measurement of the linear expansion of solid bodies depending on material, length and temperature.

Linear expansion Volume expansion of liquids Thermal capacity Lattice potential Equilibrium spacing Grüneisen equation

Benefits

Main articles Immersion thermostat Alpha A, 230 V Dilatometer with clock gauge Bath for thermostat, makrolon Tube, quartz for 04231-01 Measuring tube, l = 300 mm, IGJ 19/26 Aluminium tube for 04231-01 Set of Precision Balance Sartorius CPA 423S and measure software, 230 V

08493-93 04233-00 08487-02 04231-07 03024-00 04231-06

1 1 1 1 2 1

49223-88

1

▪ Metal tubes are fixed on the base plate and heated by hot water or steam flowing through them. ▪ Base plate with fixing holder, leading bearing and measuring unit. ▪ Transmission of linear expansion to a pointer by means of toothed rod and wheel. 04233-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 91


6 Physical Chemistry 6.4 Thermochemistry / Calorimetry

P3040801

Adsorption isotherms

Investigation of the adsorption isotherm for the citric acid/active carbon system.

Principle In general, the term adsorption is used to describe the attachment of gases or dissolved substances to the surface of a solid or liquid. At constant temperature, the quantity of adsorbed substances is a function of the type of system investigated and the partial pressure and / or concentration of the substance concerned. The correlation is described by a number of adsorption isotherms. The rivalidity is to be investigated experimentally. Tasks 1. Determine the residual equilibrium concentrations of citric acid after stirring solutions of differing initial concentrations with a constant mass of activated carbon. 2. Use the measurement results to determine which of the adsorption isotherms is valid for the given system. What you can learn about ▪ Adsorbent and adsorbate ▪ Henry Freundlich and Langmuir adsorption isotherms ▪ Volumetry

Main articles Magnetic stirrer Mini / MST Filtration stand for 2 funnels Retort stand, h = 750 mm Burette, lateral stopcock, Schellbach, 50 ml, graduations 0, 1 ml Burette clamp, roller mount., 2 pl. Activated carbon, granular 500 g Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

47334-93 33401-88 37694-00

2 1 2

36513-01 37720-00 30011-50

1 1 1

49224-88

1

excellence in science 92

Irving Langmuir 1932, Nobel Prize in Chemistry


6 Physical Chemistry 6.5 Chemical Kinetics

Saponification rate of tert-butyl chloride

P3050101

Concentration-time diagram for the saponification of tert-butyl chloride in acetone/water.

Principle Tertiary butylhalogenides are saponified in aqueous and aqueous basic solutions according to an SN1 mechanism to tertiary butanol. The kinetics of the reaction can be followed via the temporal consumption of hydroxide ions and evaluated accordingly. Tasks 1. Determine the concentration-time diagram for the saponification of tert-butyl chloride with sodium hydroxide solution. 2. Based on the experimental data, establish the valid reaction order, and calculate the reaction rate constant and the halflife of the reaction. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Reaction rate Reaction rate constant Molecularity of reaction Reaction order Rate law for first and second order reactions Half-life

Main articles Magnetic stirrer MR Hei-Standard Digital thermometer, NiCr-Ni, -50...+1300 °C Immersion probe NiCr-Ni, steel, -50...400 °C tert-Butyl chloride, 250 ml Burette clamp, roller mount.,2 pl. Caustic soda sol.,1.0 M 1000 ml Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35750-93 07050-00 13615-03 30045-25 37720-00 48329-70

1 1 1 1 1 1

49224-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 93


6 Physical Chemistry 6.5 Chemical Kinetics

P3051101

Dependence of the reaction velocity on the temperature (acetic acid - magnesium)

Schematical setup.

Principle

Magnetic stirrer MR Hei-Standard

The reaction velocity is highly dependent on the temperature. In this experiment magnesium reacts with acetic acid. Comparing the velocity at the beginning of the reaction shows that the velocity doubles when the temperature increases 10 K. Task Investigate the reaction of magnesium with acetic acid at different temperatures. What you can learn about ▪ ▪ ▪ ▪

Reaction kinetics First order reaction Magnesium Acid

Function and Applications Modern magnetic hot plate stirrer with a flat and hermetically sealed housing as protection against chemicals.

Main articles Magnetic stirrer MR Hei-Standard Electronic temperature controller EKT Hei-Con Stop clock, demo.; diam. 13 cm Round flask, 100 ml, 3-n., 3 x GL25 Gas syringe, 100 ml, with 3-way cock Magnesium, ribbon, roll, 25 g Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35750-93 35750-01 03075-00 35677-15 02617-00 30132-00

1 1 1 1 1 1

49224-88

1

excellence in science 94

Benefits ▪ Separate switchers with LEDs for heating and stirring ▪ Hot plate made of Silumin (aluminiumalloys) with ceramic coating ▪ Excellent heat conduction and distribution ▪ Extremely resistant against scratches and chemicals 35750-93


6 Physical Chemistry 6.5 Chemical Kinetics

Reaction rate and activation energy of the acid hydrolysis of ethyl acetate

P3050201

Graphic determination of the reaction rate constant for the acid hydrolysis of ethyl acetate at Tx = 299.15 K and To = 314.15 K.

Principle In acid solution, ethyl acetate is hydrolysed to equivalent quantities of ethanol and acetic acid according to a pseudo-first order rate law. The alkalimetric determination of the acetic acid formed enables conclusions to be drawn on the temporal concentration of ester. Tasks 1. Determine the reaction rate constant for the acidolysis of ethyl acetate at two (or more) temperatures. 2. Calculate the activation energy of the reaction from the temperature dependence of the measured rate constants. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Reaction rate Reaction rate constant Rate law for first and second order reactions Reactions with pseudo order Arrhenius equation Activation energy

Main articles Immersion thermostat Alpha A, 230 V Magnetic stirrer MR Hei-Standard Digital thermometer, NiCr-Ni, -50...+1300 °C Bath for thermostat, makrolon External circulation set f. thermostat Alpha A Retort stand, h = 750 mm Immersion probe NiCr-Ni, steel, -50...400 °C

08493-93 35750-93 07050-00 08487-02 08493-02 37694-00 13615-03

1 1 1 1 1 2 1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 95


6 Physical Chemistry 6.5 Chemical Kinetics

P3050301

Kinetics of the inversion of saccharose

Floating point representation of saccharose inversion as a function of time.

Principle

Half-shade polarimeter, 230 V AC

The inversion reaction of saccharose, which is catalysed by protons, produces invert sugar, which is a mixture of glucose and fructose. The reaction is accompanied by a change in the optical rotation of the system. Glucose rotates the polarisation plane of linearly polarised light to the right, while inverted sugar rotates it to the left. A half-shade polarimeter is used for the measurement of the change in the angle of rotation of polarised light during the inversion reaction of saccharose over time. Tasks 1. Determine the specific rotation of saccharose and lactose by measuring the rotation angle of solutions of various concentrations. 2. Determine the rate constant of the inversion of saccharose. What you can learn about ▪ ▪ ▪ ▪

Reaction rate First order reaction Polarimetry Optical rotation

Function and Application Half-shade polarimeter for concentration measurement of optical active solutions. Equipment and technical data

Main articles Half-shade polarimeter, 230 V AC Immersion thermostat Alpha A, 230 V Magnetic stirrer MR Hei-Standard Bath for thermostat, makrolon External circulation set f. thermostat Alpha A Retort stand, 210 × 130 mm, h = 500 mm Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

1 1 1 1 1 1

▪ ▪ ▪ ▪ ▪ ▪ ▪

49224-88

1

35906-93

excellence in science 96

Polarimeter support with built-inlight source and filters Polarimeter tube length 100 and 200 mm 2 scales 0-180 degrees Division 1 degree Vernier reading 0.05 degrees with nonius Light source sodium lamp 589 nm Power supply 230 V / 50 Hz

35906-93 08493-93 35750-93 08487-02 08493-02 37692-00


6 Physical Chemistry 6.5 Chemical Kinetics

Halogen exchange rate (with Cobra4)

P3050760

Concentration-time diagram (cPrBr = cI- = cNaI) for the Finkelstein reaction between propyl bromide and iodide ions (T = 303 K).

Principle Alkyl halides experience rapid halogen exchange reactions in appropriate solvents. These substitution reactions occur according to an SN2 mechanism. Their velocity can be advantageously monitored via conductivity measurements if the ion mobilities in question clearly differ, or the number of charge carriers changes in the course of the reaction.

Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000)

Tasks 1. Measure the specific conductivities of solutions of various concentrations of sodium iodide in acetone. 2. Subsequently determine the temporal concentrations of the co-reactants for the reaction of propyl bromide with sodium iodide (Finkelstein reaction) in acetone at 30 °C. Based on the experimental data, establish the valid order of reaction and determine the rate constant. What you can learn about

Function and Applications

▪ Reaction rate ▪ Rate laws for first and higher order reactions ▪ Conductometry

The Cobra4 Sensor Unit Conductivity / Temperature (Pt1000) is a microcontroller-based measuring recorder with a 5-pin diode socket for connecting conductance measuring sensors with a cell constant of K = 1.00/cm or Pt1000 thermocouples.

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Software Cobra4 - multi-user licence Magnetic stirrer MR Hei-Standard Electronic temperature controller EKT Hei-Con Conductivity temperature probe Pt1000

12600-00 12601-00

1 1

12632-00 14550-61 35750-93 35750-01 13701-01

1 1 1 1 1

Benefits ▪ Measure conductivity or temperature - multipurpose-sensor. ▪ The Cobra4 sensor may be connected directly to the Cobra4 Wireless-Link, the Cobra4 Mobile-Link, the Cobra4 USB-Link or the Cobra4 Junior-Link using a secure and reliable snap-in connection. 12632-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 97


6 Physical Chemistry 6.5 Chemical Kinetics

P3050860

Conductometric measurement of the saponification of esters (with Cobra4)

Change in the specific conductivity k during the saponification of ethyl butyrate in ethanol/water at an approximate ratio of 50:50 (T=323.15 K).

Principle Carboxylic acid esters are saponified in an alkaline medium according to the second order reaction rate (law). In the process, hydroxide ions with a high ion mobility are consumed in reaction with an ester. The temporal course of reaction can thus be advantageously monitored by using the measurements of the changing conductance. Tasks Determine the reaction rate constant for the saponification of ethyl butyrate in an ethanol-water mixture at 50 °C via the conductance measurements. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Reaction rate Reaction rate constant Reaction molecularity Reaction order First and second order reaction rates (laws) Conductance and conductance measurements (conductometry)

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Software Cobra4 - multi user licence Electronic temperature controller EKT Hei-Con Conductivity temperature probe Pt1000 Condenser, Dimroth type GL25/12

12600-00 12601-00

1 1

12632-00 14550-61 35750-01 13701-01 35815-15

1 1 1 1 1

excellence in science 98


6 Physical Chemistry 6.5 Chemical Kinetics

Briggs-Rauscher Reaction (with Cobra4)

P3121660

Graph of measured potential against time.

Principle The Briggs-Rauscher reaction is a so-called homogeneous oscillating reaction, i.e. the reaction rate of the complete process is subject to periodic fluctuations. In general, oscillating reactions can always occur when the following conditions are fulfilled: The reaction must run highly exergonic (ΔG << 0). At least one of the reaction steps must contain a positive or negative back-coupling. Such back-coupling processes occur when the result of the individual partial steps of the reaction, such as changes in temperature or concentration, act back on the rate constants of the individual partial steps of the reaction. In this way, the whole reaction becomes non-linear.

Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni

Task Observer the fluctuations of the Briggs-Rauscher reaction by measuring the potential over a definite time period. What you can learn about

Function and Applications

▪ Oscillating reactions; Exergonic process ▪ Potential; Briggs-Rauscher reaction

The Cobra4 Sensor-Unit Chemistry is a measuring recorder for pH, potential and temperature measurements, which is controlled by micro-controller.

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Software Cobra4 - multi-user licence Magnetic stirrer Mini / MST Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

12600-00 12601-00

1 1

12630-00 14550-61 47334-93

1 1 1

49224-88

1

Benefits ▪ It can be fitted with two NiCr-Ni thermoelements (Type K) and a pH probe or redox measuring chain ▪ Values of the calibration are saved in the sensor - no need for new calibration. ▪ The sensor is not restricted to the measurement of pH values: Connect the redox electrode 46267-10 to measure redox potentials. 12630-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 99


6 Physical Chemistry 6.5 Chemical Kinetics

Determination of the Michaelis constant (with Cobra4)

P4120360

Principle The enzymatic hydrolysis of urea in aqueous solution liberates carbon dixide and ammonia. The ions of these compounds increase the conductivity of the solution. Conductivity measurements can so be made to determine the rate of hydrolysis of urea by the enzyme urease at various substrate concentrations.

For more details refer to page 185.

Enzyme inhibition (poisoning of enzymes) (with Cobra4)

P4120560

Principle The enzymatic hydrolysis of urea in aqueous solutions liberates carbon dioxide and ammonia. The ions of these compounds increase the conducitivity of the solution.

For more details refer to page 187.

excellence in science 100


6 Physical Chemistry 6.6 Electro Chemistry

Charge transport in solids (with Cobra3)

P3060111

Dependence of resistance versus temperature (iron wire).

Principle

Power supply, universal

Measuring the temperature dependence of the resistivity of solids provides information on the mechanism of conduction and charge transport in solids. Task Determine the temperature coefficient of iron wire, copper wire and constantan wire in the range of room temperature to 95 °C. What you can learn about ▪ Electron conductivity ▪ Ion conductivity Function and Applications

Main articles Power supply, universal Cobra3 BASIC-UNIT, USB Magnetic stirrer MR Hei-Standard Cobra3 current probe 6 A Digital thermometer, NiCr-Ni, -50...+1300 °C Immersion probe NiCr-Ni, teflon, 300 °C Power supply 12V / 2A

13500-93 12150-50 35750-93 12126-00 07050-00 13615-05 12151-99

1 1 1 1 1 1 1

Cobra4 Experiment - available 2013 Charge transport in solids (with Cobra4) P3060160

Versatile heavy duty power supply which can also be used as a constant current supply in schools, laboratories or workshops. Equipment and technical data ▪ Direct current source: Stabilised, regulated output direct voltage, continuously adjustable from 0...18 V; Adjustable current limit between 0...5 A ▪ LED display for constant current operationn ▪ Permantely short-circuit proof &protected against exterior voltages ▪ Alternative voltage output: ▪ Multitap transformer 2...15V, outputs galvanically separated from mains grid ▪ Full load capacity (5A), even if direct current is supplied simultaneously ▪ Short-circuit protection through overcurrent circuit breaker ▪ All output voltages available at 4 mm safety plug sockets. 13500-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 101


6 Physical Chemistry 6.6 Electro Chemistry

P3060260

Charge transport in liquids (with Cobra4)

Conductivity of an aqueous potassium chloride solution at different temperatures.

Principle

Cobra4 Wireless-Link

A potential difference between two electrodes in a liquid causes the flow of a current in the liquid. This current depends on the potential drop across the liquid and its conductivity. The measurement of the conductivity of electrolyte solutions yields knowledge about charge transport in liquids. (Drying oven required!) Tasks 1. Measure the change in conductivity caused by diluting a 0.1 molar potassium chloride solution with distilled water. 2. Measure the conductivity of an aqueous potassium chloride solution at different temperatures. 3. Explain the observed effects. What you can learn about ▪ Electrolyte solutions ▪ Conductivity ▪ Ionic migration

Function and Applications Interface module for the radio-based transmission of sensor measuring values in conjunction with the Cobra4 Wireless Manager.

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Software Cobra4 - multi-user licence Hotplate Magnetic Stirrer, 5 ltr., 230 V Desiccator, wertex, diam. 150 mm Conductivity temperature probe Pt1000

12600-00 12601-00

1 1

12632-00 14550-61 35730-93 34126-00 13701-01

1 1 1 1 1

Benefits ▪ All Cobra4 Sensor-Units can be quickly connected using a secure and reliable plug-in / lockable connection. ▪ All Cobra4 measuring sensors are easy to plug in and automatically detected. ▪ The radio network with the Cobra4 Wireless Manager is established automatically and is extremely stable, as it uses its own radio protocol. ▪ Up to 99 Cobra4 Wireless-Links can be connected to one Cobra4 Wireless Manager. 12601-00

excellence in science 102


6 Physical Chemistry 6.6 Electro Chemistry

Ion migration velocity

P3060301

Location of colour interface versus time.

Principle

Flat chamber for ionic migration

The movement of ions is responsible for current flow in solutions of electrolytes. The migration of coloured ions can be easily observed by the migration of the colour front in an electric field. Task Demonstrate the migration of the permanganate anion in an electric field and measure the ionic velocity at five different concentrations. What you can learn about ▪ Charge transport in liquids ▪ Ion mobility ▪ Conductivity

Main articles Power supply, 0...600 V DC Flat chamber for ionic migration Tripod base PHYWE Digital multimeter 2010 Stopwatch, digital, 1/100 s Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

13672-93 06605-00 02002-55 07128-00 03071-01

1 1 1 1 1

49221-88

1

Function and Applications For demonstrating the migration of coloured ions in an electrolyte and for the determination of the absolute mobility of ions. Transparent plastic plate with engraved groove; upper face of the plastic plate blackened, except the groove. At each end face of the groove there is a nickel electrode with a 4 mm socket; the longitudinal sides of the groove have a scale with 5 mm divisions. The upper face of the plastic plate has a water level for horizontal adjustment of the flat chamber. The process of ionic migration can be especially well observed in projections using an overhead projector. 06605-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 103


6 Physical Chemistry 6.6 Electro Chemistry

P3060401

Transference numbers

Transport and electrode processes during electrolysis of diluted nitric acid.

Principle

Power supply, universal

Cations and anions contribute to charge transport in electrolytic processes in accordance with their different mobilities in an electric field. Hittorf transport numbers characterise the fraction of the total charge transported by a particular ion during electrolysis. They enable the calculation of ionic conductivities, the values of which are important in electrochemical practice. Transport numbers are to be experimentally determined from the characteristic concentration changes which take place at the cathode and the anode during electrolysis. Task Determine the Hittorf transport numbers for hydronium and nitrate ions from measurements resulting from the electrolysis of an 0.1 molar nitric acid solution. What you can learn about ▪ ▪ ▪ ▪ ▪

Electrolysis Faraday's laws of electrolysis Charge transport Ion mobility Hittorf numbers

Function and Applications Versatile heavy duty power supply which can also be used as a constant current supply in schools, laboratories or workshops. Equipment and technical data

Main articles Power supply, universal Multi-range meter w.overl.prot. Digital thermometer, NiCr-Ni, -50...+1300°C Double U-tube w.frits+cock, GL25 Glass beaker, short, 5000 ml Retort stand, h = 750 mm Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13500-93 07021-01 07050-00 44451-00 36272-00 37694-00

1 1 1 1 1 3

▪ Direct current source: Stabilised, regulated output direct voltage, continuously adjustable from 0...18 V ▪ Adjustable current limit between 0...5 A ▪ LED display for constant current operationn ▪ Permantely short-circuit proof &protected against exterior voltages ▪ Alternative voltage output: Multitap transformer 2...15V, outputs galvanically separated from mains grid

49224-88

1

13500-93

excellence in science 104


6 Physical Chemistry 6.6 Electro Chemistry

Temperature dependence of conductivity (with Cobra4)

P3060560

Diagram of the conductivity as a function of the temperature.

Principle The electrical conductivity of an electrolytic solution is dependent not only upon the type and concentration of the electrolytes, but also other state values. Thus, an increase in conductivity is generally observed with an increase in temperature. This is fundamentally due to the exponential decrease of the solutions's viscosity. In aqueous solutions a limit is reached at approximately 90°C. Above this temperature the conductivity again decreases. Task Determine the temperature dependence of the conductivity of a 10% sodium chloride solution from 20 °C to approximately 60 °C. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Function and Applications The Cobra4 Sensor Unit Conductivity / Temperature (Pt1000) is a microcontroller-based measuring recorder with a 5-pin diode socket for connecting conductance measuring sensors with a cell constant of K = 1.00/cm or Pt1000 thermocouples. Benefit ▪ Measure conductivity or temperature - multipurpose-sensor. 12632-00

Electrolytic resistance Conductance Specific and molar conductivity Ion mobility Equivalent conductance at infinite dilution Kohlrausch's law Ostwald's law of dilution Transference numbers Viscosity

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Software Cobra4 - multi-user licence Electronic temperature controller EKT Hei-Con Magnetic stirrer MR Hei-Standard Conductivity temperature probe Pt1000

12600-00 12601-00

1 1

12632-00 14550-61 35750-01 35750-93 13701-01

1 1 1 1 1

Wilhelm Ostwald 1909, Nobel Prize in Chemistry

PHYWE Systeme GmbH & Co. KG · www.phywe.com 105


6 Physical Chemistry 6.6 Electro Chemistry

P3060660

Conductivity of strong and weak electrolytes (with Cobra4)

Conductivity of a strong electrolyte as a function of the concentration.

Principle

Magnetic stirrer Mini / MST

It is possible to differentiate between strong and weak electrolytes by measuring their electrical conductance. Strong electrolytes follow Kohlrausch's law, whereas weak electrolytes are described by Ostwald's dilution law. The examination of the concentration dependence of the conductivity allows the molar conductivities of infinitely diluted electrolytes to be determined, and facilitates the calculation of degree of dissociation and the dissociation constants of weak electrolytes. Tasks 1. Determine the concentration dependence of the electrical conductivity of potassium chloride and acetic acid solutions. 2. Calculate the molar conductivity using data from the measurements taken and determine the molar conductivity at infinite dilution by extrapolation. 3. Determine the dissociation constant of acetic acid. What you can learn about ▪ ▪ ▪ ▪

Kohlrausch's law Equivalent conductivity Temperature-dependence of conductivity Ostwald's dilution law

12600-00 12601-00

1 1

12632-00 14550-61 34126-00 47334-93

1 1 1 1

49224-88

1

excellence in science 106

Magnetic stirrer without heating for mixing smaller quantities. Benefits ▪ All housing parts are made of a sturdy, reinforced ABS plastic material that is resistant to many chemicals ▪ Electronic speed control to protect the engine against uncontrolled acceleration ▪ The speed is infinitely adjustable ▪ Delivery includes a magnetic stirring bar Equipment and technical data ▪ ▪ ▪ ▪ ▪

Stirring capacity: max. 1l water Speed: 100 .. 1000 rpm Without heating Diameter: 137 mm Height: 51 mm; Weight: 0.6 kg

47334-93

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Software Cobra4 - multi-user licence Desiccator, wertex, diam. 150 mm Magnetic stirrer Mini / MST Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

Function and Applications


6 Physical Chemistry 6.6 Electro Chemistry

Determination of the activity coefficient by a conductivity measurement (with Cobra4)

P3060862

Curves for potassium chloride and calcium chloride.

Principle

Conductivity temperature probe Pt1000

The equivalent conductivity of strong electrolytes depends on their concentration. The quotient of the equivalent conductivity at a certain concentration and the equivalent conductivity at infinite dilution is called the conductivity coefficient, which is the result of interionic action. Tasks 1. Measure the specific conductivities of various potassium chloride and calcium chloride solutions and calculate the equivalent conductivities. 2. Determine the equivalent conductivities at infinite dilution using the Kohlrausch equation and calculate the conductivity coefficients. What you can learn about ▪ ▪ ▪ ▪

Equivalent conductivity Ion mobility Conductivity Interionic action

Function and Applications Conductivity temperature probe Pt1000

Main articles Cobra4 Mobile-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Desiccator, wertex, diam. 150 mm Conductivity temperature probe Pt1000 Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

12620-00

1

12632-00 34126-00 13701-01

1 1 1

49221-88

1

Equipment and technical data ▪ Cell constant k = 1.0 / cm ▪ Minimum immersion depth: 10 mm 13701-01

PHYWE Systeme GmbH & Co. KG · www.phywe.com 107


6 Physical Chemistry 6.6 Electro Chemistry

P3060962

Nernst equation (with Cobra4)

Verification of the Nernst equation for the Fe(CN)64-, Fe(CN)63- Pt redox electrode.

Principle The Nernst equation expresses how the electrical potential of an electrode in contact with a solution of ions depends upon the concentrations (more accurately, activities) of those ions. The equation may be experimentally verified using an electrochemical cell formed from an inert indictator electrode coupled with a convenient reference electrode. The potential of the indicator electrode, and hence the e.m.f. of the cell, is monitored as the ionic composition of the electrolyte solution is changed. Tasks Using an Ag(S) I AgCl(S) l Cl- reference electrode, measure the potential of a platinum electrode in contant with solutions containing known concentration of the iron(II) and iron(lII) complex ions [Fe(CN)6]4 - and [Fe(CN)6]3-. What you can learn about ▪ Electrode potentials and their concentration dependence ▪ Redox electrodes ▪ Electrochemical cells

Main articles Cobra4 Mobile-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Immersion probe NiCr-Ni, teflon, 300 °C Magnetic stirrer Mini / MST Reference electrode, AgCl Retort stand, h = 750 mm Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

12620-00

1

12630-00 13615-05 47334-93 18475-00 37694-00

1 1 1 1 2

49221-88

1

excellence in science 108


6 Physical Chemistry 6.6 Electro Chemistry

Determination of diffusion potentials

P3061101

Diffusion potential D jD for HCI as a function of ln a2/a1 (o) and ln c2/c1 (x) (for cellophane).

Principle

Osmosis and electrochemistry chamber

An electrochemical potential establishes itself at the interface between two solutions of different ion concentrations. The magnitude of this is determined by the concentration ratio and the transference numbers of the ions involved. This potential difference can be measured as a function of the concentration at semi-permeable and ion-selective membranes. Tasks 1. Measure the diffusion potential as a function of the concentration gradient at a cellophane membrane and at a cationselective membrane. 2. Determine the transference numbers of the ions in HCl, NaCl and KCl. What you can learn about ▪ ▪ ▪ ▪ ▪

Concentration cells with transport Transference numbers Semi-permeable membrane Selectively permeable membrane Nernst equation

Function and Applications Osmosis and electrochemistry chamber for the demonstration and observation of osmotic processes.

Main articles Osmosis and electrochemistry chamber Digital thermometer, NiCr-Ni, -50...+1300 °C Magnetic stirrer Mini / MST Digital multimeter 2010 Gasket for GL25, 12mm hole, 10pcs Retort stand, h = 750 mm Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35821-00 07050-00 47334-93 07128-00 41243-03 37694-00

1 1 1 1 1 1

49224-88

1

The chamber can be build up and cleaned without problems. Between two sealing rings arbitrary semipermeable membranes can be fixed. A measurable rise is achieved by the big boundary surface of differently concentrated solutions very quickly in the capillary tube. For the readout of the altitude a scale can be put on the capillary tube. 35821-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 109


6 Physical Chemistry 6.6 Electro Chemistry

P3061262

Temperature dependence of the electromotive force (with Cobra4)

Electromotive force versus temperature.

Principle Thermodynamic data of the gross reaction in a galvanic cell can be determined by measuring the e.m.f. at different temperatures. Task Determine the usable reaction equivalent work of the Daniell cell by measuring the dependence of the electromotive force on temperature. What you can learn about ▪ ▪ ▪ ▪

Electromotive force Electrode reactions Electrochemical potential Nernst equation

Main articles Temperature meter digital, 4-2 Immersion thermostat Alpha A, 230 V Cobra4 Mobile-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Temp. probe, immersion type, Pt100, stainless steel, -20...+300 °C Bath for thermostat, makrolon Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13617-93 08493-93 12620-00

1 1 1

12630-00

1

11759-01 08487-02

3 1

49224-88

1

excellence in science 110


6 Physical Chemistry 6.6 Electro Chemistry

pH measurement (with Cobra4)

P3061562

Calibration curves for the antimony (o) and quinhydrone (x) electrode. The cell e.m.f. E is measured using a Ag(S)|AgCl(S)|Cl- (aq.) reference electrode.

Principle

What you can learn about

The course, reaction rate and equilibrium position of many chemical reactions are strongly influenced by the concentration or more accurately, the activity of hydrogen ions in solutions αH+. Rapid and accurate determinations of hydrogen ion activity are thus of great importance. Since αH+ can vary over many orders of magnitude, it has proved convenient to introduce the pH scale (pH from the Latin "pondus hydrogenii" meaning "amount of hydrogen"). The most important and common method used to determine the pH value is to measure the potential of the electrode which is sensitive to hydrogen ion activity.

▪ ▪ ▪ ▪

In certain practical situations, however, a simpler and more direct method of determining pH is required, and use is often made of pH indicators. Tasks ▪ Calibrate the following pH-sensitive electrodes in buffer solutions of known pH:

Potentiometric determination of pH Glass electrode pH indicators Acid-base titrations

Main articles Cobra4 Mobile-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Antimony electrode Immersion probe NiCr-Ni, teflon, 300 °C Magnetic stirrer Mini / MST Quinhydrone 100 g Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

12620-00

1

12630-00 18477-01 13615-05 47334-93 31195-10

1 1 1 1 1

49224-88

1

1. the glass electrode 2. the antimony electrode 3. the quinhydrone electrode ▪ Using these calibrated electrodes, measure the pH of an unknown solution. Compare and contrast the results obtained with the three pH-sensitive electrode. ▪ Use the glass electrode to determine the pH range in which the following indicators change colour: 1. methyl orange 2. bromothymol blue 3. phenolphthalein ▪ Compare the suitability of the three indicators for different types of acid-base titrations.

PHYWE Systeme GmbH & Co. KG · www.phywe.com 111


6 Physical Chemistry 6.6 Electro Chemistry

P3061811

Electrode kinetics: The hydrogen overpotential of metals (with Cobra3)

Current-potential curve for the electrolysis of HCI solution using graphite electrodes.

Principle

What you can learn about

If the oxidation and reduction steps of an electrode reaction are rapid (high exchange current densities) then the passage of charge across the electrode-solution interface will barely displace the reaction equilibrium. Such an electrode is said to be non-polarisable in the sense that its potential, for small currents, is stable and equal to the equilibrium electrode potential.

▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

If, on the other hand, reaction equilibrium is established only slowly due to the kinetic inhibition of a step involved in the electrode reaction, then the electrode is said to be polarisable. To induce the reaction to proceed in a given direction the kinetic inhhibition of the reaction must be overcome by applying a high overpotential. Electrode polarisation and the presence of overpotentials are important concepts in understanding electrode processes. They underlie the fact that galvanic cells always deliver current at less than the equilibrium e.m.f. and that an applied potential greater than the equilibrium e.m.f. is required in order to drive a reaction in an electrolytic cell. Futhermore, a number of important electochemical devices (e.g. the lead-acid accumulator) and electroanalytical techniques (e.g. polarography) make use of the inhibition (high overpotential) of certain electrode reactions. Tasks 1. Record the current-potential curve for the electrolysis of a 1 M hydrochloric acid solution using graphite rod electrodes and determine the decomposition voltage. 2. Discuss the physical processes determining the form of this curve. 3. By replacing the graphite rod cathode with a series of different metal rod electrodes, compare the overpotentials for hydrogen evolution at these metals.

excellence in science 112

Electrode kinetics Polarisation Overpotential Irreversible processes The electrode-electrolyte interface Voltammetry and current-potential curves Relevance to electrolysis Fuel cells Corrosion Polarography

Main articles Power supply, universal Cobra3 BASIC-UNIT, USB Cobra3 current probe 6A Retort stand, h = 750 mm Power supply 12V / 2A Nickel electrode, d = 8 mm Software Cobra3 Universal recorder

13500-93 12150-50 12126-00 37694-00 12151-99 45205-00 14504-61

Cobra4 Experiment Electrode kinetics: The hydrogen overpotential of metals (with Cobra4) P3061860

1 1 1 1 1 1 1


6 Physical Chemistry 6.6 Electro Chemistry

Determination of Faraday's constant

P3062101

Correlation between the transferred charge and the evolved volumes of hydrogen and oxygen in the electrolysis of diluted sulphuric acid (T = 296.05 K and p =100.4 kPa).

Principle

Electrolysis apparatus-Hofmann

Faraday's laws of electrolysis describe the correlation between the amounts of substances transformed in the reactions at the electrodes and the charge applied (amount of electricity). Faraday's constant, which appears as a proportionality factor, can be determined experimentally from the dependence. Tasks Determine Faraday's constant from the dependence of the volumes of hydrogen and oxygen envolved on the charge applied in the hydrolysis of dilute sulphuric acid. What you can learn about ▪ ▪ ▪ ▪ ▪

Electrolysis coulometry Charge Faraday's laws Avogadro's number General equation of state for ideal gases

Main articles Power supply, universal Electrolysis apparatus-Hofmann Weather monitor, 6 lines LCD Digital multimeter 2010 On/off switch Retort stand, h = 750 mm Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13500-93 44518-00 87997-10 07128-00 06034-01 37694-00

1 1 1 1 1 1

49224-88

1

Function and Applications Electrolysis apparatus-Hofmann. Equipment and technical data ▪ ▪ ▪ ▪

Electrolysis apparatus-Hofmann 2 communicating glass tubes, l = 510 mm Measuring range: 50 ml Graduation: 0.2 ml

44518-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 113


6 Physical Chemistry 6.6 Electro Chemistry

P2411100

Characteristic curve and efficiency of a PEM fuel cell and a PEM electrolyser

Volume of the hydrogen generated by the PEM electrolyser as a function of time at different current I.

Principle In a PEM electrolyser, the electrolyte consists of a proton-conducting membrane and water (PEM = Proton-Exchange-Membrane). When an electric voltage is applied, hydrogen and oxygen are formed. The PEM fuel cell generates electrical energy from hydrogen and oxygen. The electrical properties of the electrolyser and the fuel cell are investigated by recording a current-voltage characteristic line. To determine the efficiency, the gases are stored in small gasometers in order to be able to measure the quantities of the gases generated or consumed.

Function and Applications

Tasks

For the production of hydrogen and oxygen through electrolysis.

1. 2. 3. 4.

Equipment and technical data

Recording the characteristic line of the PEM electrolyser. Recording the characteristic line of the PEM fuel cell. Determination of the efficiency of the PEM electrolysis unit. Determination of the efficiency of the PEM fuel cell.

What you can learn about ▪ ▪ ▪ ▪ ▪

Electrolysis Electrode polarisation Decomposition voltage Galvanic elements Faraday's law

Main articles Power supply, universal PEM electrolyser Cobra4 Mobile-Link set, incl. rechargeable batteries, SD memory card, USB cable and software "measure" PEM fuel cell

13500-93 06748-00

1 1

12620-55 06747-00

1 1

excellence in science 114

Cobra4 Sensor-Unit Weather: Humidity, Air pressure,Temperature, Light intensity, Altitude Gas bar Digital multimeter 2010

12670-00 40466-00 07128-00

1 1 2

PEM electrolyser

▪ Electrolyser and storage container for distilled water mounted on a stable baseplate. ▪ Without use of caustic lyes or acids. ▪ Only distilled water is used for operating it. ▪ Voltage input protected against polarity reversal. ▪ Operating instructions with detailed description of experiment. ▪ Electrode surface: 16 cm2. ▪ Output: 4 W. ▪ Voltage required: 1.7...2 V. 06748-00


6 Physical Chemistry 6.6 Electro Chemistry

Electrogravimetric determination of copper

P3062201

Electric circuit for electrolysis.

Principle

Digital multimeter 2010

Electrogravimetry is an important analytical method for the quantitative determination or separation of species in solution. The technique involves the quantitative electrolytic deposition of an element, usually a metal, on a suitable electrode in weighable form. Task Perform an accurate electrogravimetric determination of the amount of copper in a given sample solution. What you can learn about ▪ ▪ ▪ ▪ ▪

Quantitative analysis Gravimetry Electrolysis Overpotential Electrode polarisation

Function and Applications 3 ½ digit Steady performance digital-multimeter. Benefits

Main articles Pt electrodes, electrogravimetry Power supply, universal Magnetic stirrer MR Hei-Standard Electronic temperature controller EKT Hei-Con Digital multimeter 2010 Ethyl alcohol, absolute 500 ml Set of Analytical Balance Sartorius CPA 224S and measure software, 230 V

45210-00 13500-93 35750-93 35750-01 07128-00 30008-50

1 1 1 1 2 1

49221-88

1

▪ Provides an overload protection and the functions of measuring like DCV, ACV, DCA, ACA, resistance, capacitance, frequency, diode, continuity test with buzzer and temperature. ▪ Ideal for the education- and service-fields. Equipment and techical data ▪ ▪ ▪ ▪ ▪ ▪ ▪

3 ½-dgt. LCD display, 28 mm, with backlight Manual range selection Low battery indication FE-Test Peak-hold Auto power off Safety: IEC-1010-1; CAT II 1000 V

07128-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 115


6 Physical Chemistry 6.6 Electro Chemistry

Voltage of a concentration cell (with Cobra4)

P1268360 Principle The electric potential of a metal in a salt solution of it is dependent on the concentration of the solution. A potential difference can be measured between solutions of different concentrations when they are connected electrically conducting to one another. Two silver/silver nitrate half-cells to be are used to demonstrate this.

For more details refer to www.phywe.com

Electrochemical series of metals (with Cobra4)

P1282360 Principle The characteristics of a metal are determined to a great extent by how easily it can be oxidized. The listing of metals in the succession of their oxidizability, i.e. according to their striving to form cations, is called the electrochemical series of metals. When a metal is dipped into a solution which contains cations of that metal, a voltage is built up between the metal and the solution in this half-cell. Connection together of two such half-cells of different metals so that they are electrically conducting enables the voltage difference between them to be measured. The electrochemical series of metals can be derived from measurements of such voltage differences.

For more details refer to www.phywe.com

excellence in science 116


6 Physical Chemistry 6.7 Phase Equilibrium

Boiling point elevation

P3021001

Boiling point increase as a function of concentration of table salt in an aqueous solution.

Principle

Temperature meter digital, 4-2

The boiling point of a solution is always higher than that of the pure solvent. The dependence of the temperature difference (elevated boiling point) on the concentration of the solute can be determined using a suitable apparatus. Tasks 1. Measure the increase in the boiling point of water as a function of the concentration of table salt, urea and hydroquinone. 2. Investigate the relationship between the increase in boiling point and the number of pellets. 3. Determine the molar mass of the solute from the relationship between the increase in boiling point and the concentration. What you can learn about ▪ Raoult's law; Henry's law; Ebullioscopic constants ▪ Chemical potential; Gibbs-Helmholtz equation ▪ Concentration ratio; Degree of dissociation

Function and Application

Main articles Temperature meter digital, 4-2 Heating mantle for roundbottom flask, 250 ml, 230 V, with saftey switch Temp.probe, imm., PT100, -20...+300 °C, teflon Apparatus for elevation of boiling point Power regulator Pellet press for calorimeter Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13617-93

1

49542-93

1

11759-04 36820-00 32288-93 04403-04

1 1 1 1

49224-88

1

Modern, user-friendly designed instrument for measuring temperature and temperature differences at four different measuring points. Benefits ▪ Two demonstrative 4 digit LED display (+ sign), with 20 mm high digits for presentation of the values measured at the selected measuring points. ▪ RS 232 interface for simultaneous display and evaluation of the measured values from all four measuring points with a computer. 13617-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 117


6 Physical Chemistry 6.7 Phase Equilibrium

P3021101

Freezing point depression

Cooling curve of water/table salt mixture.

Principle

Crystal-lattice model ice

The freezing point of a solution is lower than that of the pure solvent. The depression of the freezing point can be determined experimentally using a suitable apparatus (cryoscopy). If the cryoscopy constants of the solvent are known, the molecular mass of the substance dissolved can be determined. Tasks 1. Determine the size of freezing point depression after dissolving a strong electrolyte (NaCl) in water. By comparing the experimental value with the theoretical one predicted for this concentration, determine the number of ions into which the electrolyte dissociates. 2. Determine the molar mass of a non-electrolyte (hydroquinone) from the value of freezing point depression. What you can learn about ▪ Raoult's law; Cryoscopic constant; Chemical potential ▪ Gibbs-Helmholtz equation; Concentration ratio ▪ Degree of dissociation; Van't Hoff factor

Function and Applications

Main articles Temperature meter digital, 4-2 Magnetic stirrer MR Hei-Standard Apparatus for freezing point depression Temp. probe, immersion type, Pt100, stainless steel, -20...+300 °C Pellet press for calorimeter Gasket for GL25, 12 mm hole, 10 pcs. Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

13617-93 35750-93 36821-00

1 1 1

11759-01 04403-04 41243-03

2 1 1

49224-88

1

excellence in science 118

High quality crystal-lattice model consisting of coloured wooden balls and metallic links; the model will be delivered completely fixed. Equipment and technical data ▪ Scale to real crystals: 1 : 250 million ▪ Diameter of the balls: approx. 20 mm 40022-00


6 Physical Chemistry 6.7 Phase Equilibrium

Boiling point diagram of a binary mixture

P3030401

Index of refraction as a function of substance concentration in methanol/chloroform mixtures.

Principle

Abbe refractometer

A boiling point diagram shows the boiling points of a binary mixture as a function of the vapour / liquid equilibrium of the mixture at constant pressure. The boiling points of various mixtures of methanol and chloroform are measured and the composition of the liquid phases are determined using refractometry and a calibration curve. Tasks 1. Determine the refractive indices of the pure components and about 10 different mixtures of known composition. 2. Plot the boiling point diagram of the binary mixtures of methanol and chloroform. What you can learn about ▪ ▪ ▪ ▪ ▪

Fundamentals of distillation Equilibrium diagram Chemical potential Activity coefficient Raoult's law

Main articles Abbe refractometer Temperature meter digital, 4-2 Immersion thermostat Alpha A, 230 V Heating mantle for roundbottom flask, 100 ml, 230 V, with safety switch Power regulator Column head, with stopcock, IGJ 19/26 Bath for thermostat, makrolon

35912-00 13617-93 08493-93

1 1 1

49541-93 32288-93 35919-01 08487-02

1 1 1 1

Function and Applications Abbe refractometer for measuring the refraction index of liquids and solids with light of 590 nm wavelength (sodium D line) and determining average dispersion nC-nF. The refractive index scale also includes an additional scale indicating sugar content from 0 - 95%. The prism and scales can be illuminated by daylight or by a separate lighting unit. 35912-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 119


6 Physical Chemistry 6.7 Phase Equilibrium

P1273460

Heat of fusion of sodium thiosulphate (with Cobra4)

Measurement result, the temperature over time in the range from 20 °C to about 70 °C.

Principle

Software Cobra4 - multi-user licence

The temperature course during the melting and crystallization of sodium thiosulphate is determined. Task Investigate the temperature rise during crystallisation of sodium thiosulfate. What you can learn about ▪ ▪ ▪ ▪ ▪

Melting Crystallization Sodium thiosulphate Fusion enthalpy Supercooled melt

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Software Cobra4 - multi-user licence Immersion probe NiCr-Ni, steel, -50...400 °C Retort stand, 210 mm × 130 mm, h = 500 mm Holder for Cobra4 with support rod

12600-00 12601-00

1 1

12630-00 14550-61 13615-03

1 1 1

37692-00 12680-00

1 1

Function and Applications The "measure Cobra4" measuring software leaves nothing to be desired. As soon as a Cobra4 sensor is connected to a PC, irrespective of whether by Cobra4 Wireless or Cobra4 USB Link, the "measure Cobra4" software opens completely automatically and shows the connected sensors, the required measuring windows and the current measuring data. 14550-61

excellence in science 120


6 Physical Chemistry 6.7 Phase Equilibrium

Melting diagram of a binary mixture (with Cobra4 )

P3031360

Cooling curve of a mixture of naphthalene and biphenyl.

Principle In plotting the cooling curves of binary mixtures one determines the temperatures of melting and solidification of specimens with differing fractions (molar fractions) of the two components. These results are entered in a temperature versus concentration diagram. Tasks 1. Record the melting point diagram of a mixture of biphenyl and naphthalene. 2. Determine the composition of the eutectic mixture and its melting point from the melting point diagram. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Melt Melting point Melting point diagram Binary system Miscibility gap Mixed crystal Eutectic mixture Gibbs' phase law

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit 2 x Temperature, NiCr-Ni Thermocouple NiCr-Ni, sheathed -50...1100°C Holder for Cobra4 with support rod Software Cobra4 - multi-user licence Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

12600-00 12601-00 12641-00

1 1 1

13615-01 12680-00 14550-61

1 1 1

49224-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 121


6 Physical Chemistry 6.7 Phase Equilibrium

P3011400

Condensation of gases through an increase of pressure and through cooling

Schematical setup of the experiment.

Principle

Gas liquefier

Gases are condensing when they are cooled and at high pressure. In this experiment butane is condensed by cooling it to ca. -15 °C. In the second part of the experiment butane is condensed by compressing it. Tasks 1. Condense butane by cooling it under its boiling point of -0.4 °C. 2. Condense butane at high pressure. What you can learn about ▪ Condensation ▪ Gas laws

Main articles Gasometer 1000 ml Gas liquefier Dewar vessel,500 ml Lab jack, 160 x 130 mm Butane burner, Labogaz 206 type Quartz glass wool 10 g

40461-00 08173-00 33006-00 02074-00 32178-00 31773-03

1 1 1 1 1 1

Function and Applications Gas liquifier, for demonstrating isothermal condensation and evaporation due to changes in pressure and volume. Equipment and technical data ▪ Plastic-coated glass tube, piston with handle. ▪ Length: 270 mm. ▪ Diameter: 27 mm. 08173-00

excellence in science 122


6 Physical Chemistry 6.7 Phase Equilibrium

Sublimation and solubility of iodine

P3031900

Solubility of iodine in oxygenated and deoxygenated solvents.

Principle

Condenser, reflux, with 2 Gl connection

Iodine, whose melting point is at 113.5 °C, evaporates clearly below this temperature. It passes from the solid state directly to the gaseous state. This process is known as sublimation. When iodine vapour cools down, solid crystals form, again without a liquid transitional phase. This process is known as resublimation. Tasks 1. Show sublimation and resublimation of iodine. 2. Investigate the solubility of iodine in oxygen-containing and oxygen-free solvents. What you can learn about ▪ ▪ ▪ ▪

Sublimation Resublimation Solubility Iodine

Main articles Round bottom flask, 250 ml, 2-neck, GL25/ 12, GL18/8 Retort stand, h = 750 mm Ethyl alcohol, absolute 500 ml Cyclohexane 1000 ml Condenser, reflux, with 2Gl conn. Closure caps,10, GL18

35843-15 37694-00 30008-50 31223-70 35900-02 41220-03

1 1 1 1 1 1

Function and Applications Condenser, reflux, with 2 Gl connection. Equipment and technical data ▪ Jacket length: 190 mm ▪ Diameter of the olives: 8 mm ▪ Made of DURAN® 35900-02

PHYWE Systeme GmbH & Co. KG · www.phywe.com 123


6 Physical Chemistry 6.7 Phase Equilibrium

Steam distillation

P3031251 Principle An elegant and simple apparatus for carrying out water vapour distillations: the advantage of this arrangement is that it eliminates the need for a separate vapour generator, making it possible to operate with a single heat source (other set-ups require two). The vapour is generated in the outer chamber and then passes through the inner chamber. Due to the structural arrangement, the inner chamber is heated directly by the vapour generated in the outer chamber. This also eliminates the possibility of overheating the substances being extracted. Parts of plants suitable for the extraction of essential oils include orange peel and cloves, for example.

For more details refer to page 161.

Rectification - the number of theoretical trays in a distillation column

P3031501

Principle The separation power of a rectification (fractionating) column can be determined using an appropriate binary mixture whose equilibrium composition is measured in the distillation flask and in the domed glass head of the distillation apparatus. The number of theoretical trays can be numerically or graphically obtained from the measured values.

For more details refer to pages 160, 177.

Fractional distillation with the bubble tray column (with Cobra3)

P3031640

Principle In countercurrent distillation (rectification) using a column, the rising vapour can enter into interactions with the condensate. In this manner, a fractional distillation, i.e. a distillation in several steps for the separation of substances with similar boiling points, can be performed in a single apparatus. If bubble tray columns are used condensate can be removed from the individual bubble trays.

For more details refer to page 176.

excellence in science 124


6 Physical Chemistry 6.8 Atomic Structures and Properties

Franck-Hertz experiment with a Ne-tube

P2510315

Example of a Franck-Hertz curve for Ne-gas.

Principle Electrons are accelerated in a tube filled with neon vapour. The excitation energy of neon is determined from the distance between the equidistant minima of the electron current in a variable opposing electric field.

Related Experiment Franck-Hertz experiment with a Hg-tube P2510311

Tasks 1. To record the counter current strength I in a Franck-Hertz tube as a function of the anode voltage U. 2. To determine the excitation energy E from the positions of the current strength minima or maxima by difference formation. What you can learn about ▪ ▪ ▪ ▪

Energy quantum Quantum leap Electron collision Excitation energy

Main articles Franck-Hertz control unit Franck-Hertz Ne-tube w. housing Connect.cord for Franck-H. Ne-tube Software Measure Franck-Hertz experiment Screened cable, BNC, l = 750 mm Data cable, plug/ socket, 9 pole

09105-99 09105-40 09105-50 14522-61 07542-11 14602-00

1 1 1 1 1 1

James Franck (left) and Gustav Hertz (right) 1925, Nobel Prize in Physics

PHYWE Systeme GmbH & Co. KG · www.phywe.com 125


6 Physical Chemistry 6.8 Atomic Structures and Properties

P2510600

Fine structure: One and two electron spectra

Spectrum of sodium.

Principle

Spectrometer/goniometer with vernier

The well-known spectral lines of He are used for calibrating the diffraction spectrometer. The wave-lengths of the spectral lines of Na, Hg, Cd and Zn are determined using the spectrometer. Tasks 1. Calibration of the spectrometer using the He spectrum and the determination of the constant of the grating. 2. Determination of the spectrum of Na. 3. Determination of the fine structure splitting. 4. Determination of the most intense spectral lines of Hg, Cd and Zn. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Diffraction spectrometer; Spin Angular momentum Spin-orbital angular momentum interaction Multiplicity; Energy level; Excitation energy Selection rules; Doublets; Parahelium Orthohelium, Exchange energy Angular momentum; Singlet and triplet series Selection rules; Forbidden transitions

Function and Applications Spectrometer/ goniometer with double vernier. Equipment and technical data ▪ With magnifying glasses ▪ 60° glass prism ▪ Illumination device and telescope

Main articles

35635-02

Spectrometer/goniom. w. vernier Spectral lamp He, pico 9 base Power supply for spectral lamps Spectral lamp Na, pico 9 base Spectral lamp Hg 100, pico 9 base Spectral lamp Zn, pico 9 base Spectral lamp Cd, pico 9 base

35635-02 08120-03 13662-97 08120-07 08120-14 08120-11 08120-01

excellence in science 126

1 1 1 1 1 1 1


6 Physical Chemistry 6.8 Atomic Structures and Properties

Balmer series/ determination of Rydberg's constant

P2510700

Energy level diagram of the H atom.

Principle

High voltage supply unit, 0-10 kV

The spectral lines of hydrogen and mercury are examined by means of a diffraction grating. The known spectral lines of Hg are used to determine the grating constant. The wave lengths of the visible lines of the Balmer series of H are measured. Tasks 1. Determination of the diffraction grating constant by means of the Hg spectrum. 2. Determination of the visible lines of the Balmer series in the H spectrum, of Rydberg's constant and of the energy levels. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Function and Applications

Diffraction image of a diffraction grating Visible spectral range Single electron atom Atomic model according to Bohr Lyman-, Paschen-, Brackett and Pfund Series Energy level Planck's constant Binding energy

For electrostatic experiments and for operation of spectral and gas discharge tubes. Equipment and technical data

Main articles High voltage supply unit, 0-10 kV Object holder, 5x5 cm Spectrum tube, hydrogen Spectrum tube, mercury Diffraction grating, 600 lines/mm Tripod base PHYWE Insulating support

13670-93 08041-00 06665-00 06664-00 08546-00 02002-55 06020-00

1 1 1 1 1 1 2

▪ It supplies 3 continuously variable DC voltages isolated from earth and ground. ▪ Two of the voltages are connected in series 0-5 kV DC = total of 0 -10 kV DC. ▪ Selectable positive and negative polarity. ▪ 3-figure LED display. Outputs short-circuit proof. ▪ Special safety sockets. ▪ Modern plastic housing, impact resistant, easy to service, light stackable with retractable carrying handle and stand. ▪ Internal resistance: approx. 5 MOhm. ▪ Ripple: < 0.5%; Supply voltage: 230 V. ▪ Short circuit current: max. 3 mA. ▪ Housing dimensions (mm): 230 x 236 x 168. 13670-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 127


6 Physical Chemistry 6.8 Atomic Structures and Properties

P2510200

Specific charge of the electron e/m

Detail of experimental setup.

In Cooperation with:

Principle Electrons are accelerated in an electric field and enter a magnetic field at right angles to the direction of motion. The specific charge of the electron is determined from the accelerating voltage, the magnetic field strength and the radius of the electron orbit. Task Determination of the specific charge of the electron (e/m) from the path of an electron beam in crossed electric and magnetic fields of variable strength.

National University of Science and Technology

What you can learn about ▪ ▪ ▪ ▪ ▪

"MISIS" in Moscow, Russia

Cathode rays Lorentz force Electron charge Electron in crossed fields Electron mass

e/m - Observation chamber

Main articles Narrow beam tube Helmholtz coils, one pair Power supply, 0...600 VDC Power supply, universal e/m - Observation Chamber Digital multimeter 2010

06959-00 06960-00 13672-93 13500-93 06959-01 07128-00

1 1 1 1 1 2 Function and Application Observation Chamber for Covering the e/m experiment (helmholtz coils and narrow beam tube). 06959-01

excellence in science 128


6 Physical Chemistry 6.8 Atomic Structures and Properties

Zeeman effect with a variable magnetic system

P2511006

Interference rings with the anomalous Zeeman effect.

Main articles Principle The "Zeeman effect" is the splitting up of the spectral lines of atoms within a magnetic field. The simplest is the splitting up of one spectral line into three components called the "normal Zeeman effect". In this experiment the normal Zeeman effect as well as the anomalous Zeeman effect are studied using a cadmium spectral lamp as a specimen.

Fabry-Perot interferometer Magnetic System, variable Cadmium lamp for Zeeman effect Power supply for spectral lamps Sliding device, horizontal Optical profile-bench, l = 1000mm Polarising filter, on stem

09050-02 06327-00 09050-20 13662-97 08713-00 08282-00 08610-00

1 1 1 1 1 1 1

The cadmium lamp is submitted to different magnetic flux densities and the splitting up of the cadmium lines (normal Zeeman effect 643.8 nm, red light; anomalous Zeeman effect 508.6 nm, green light) is investigated using a Fabry-Perot interferometer. The evaluation of the results leads to a fairly precise value for Bohr's magneton. Tasks 1. Using the Fabry-Perot interferometer and a selfmade telescope the splitting up of the central line into different lines is measured in wave numbers as a function of the magnetic flux density. 2. From the results of point 1. a value for Bohr's magneton is evaluated. 3. The light emitted within the direction of the magnetic field is qualitatively investigated. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Bohr's atomic model Quantisation of energy levels Electron spin Bohr's magneton Interference of electromagnetic waves Fabry-Perot interferometer

Pieter Zeeman 1902, Nobel Prize in Physics

PHYWE Systeme GmbH & Co. KG · www.phywe.com 129


6 Physical Chemistry 6.8 Atomic Structures and Properties

P2511111

Stern-Gerlach experiment with a step motor and interface

Ionization current as a function of position (u) of detector with large excitation currents in the magnetic analyser.

Principle A beam of potassium atoms generated in a hot furnace travels along a specific path in a magnetic two-wire field. Because of the magnetic moment of the potassium atoms, the nonhomogenity of the field applies a force at right angles to the direction of their motion. The potassium atoms are thereby deflected from their path. By measuring the density of the beam of particles in a plane of detection lying behind the magnetic field, it is possible to draw conclusions as to the magnitude and direction of the magnetic moment of the potassium atoms.

High vacuum pump assembly,compact Step motor Stern-Gerlach appartus Electromagnet w/o pole shoes DC measuring amplifier Step motor unit Potassium ampoules, set of 6

Tasks 1. Recording the distribution of the particle beam density in the detection plane in the absence of the effective magnetic field. 2. Fitting a curve consisting of a straight line, a parabola, and another straight line, to the experimentally determined special distribution of the particle beam density. 3. Determining the dependence of the particle beam density in the detection plane with different values of the non-homogenity of the effective magnetic field. 4. Investigating the positions of the maxima of the particle beam density as a function of the non-homogeneity of the magnetic field. What you can learn about ▪ Magnetic moment; Bohr magneton; Directional quantisation ▪ g-factor; Electron spin; Atomic beam ▪ Maxwellian velocity distribution; Two-wire field

Main articles

Otto Stern

Stern-Gerlach apparatus

09054-88

excellence in science 130

1

1943, Nobel Prize in Physics

09059-99 09054-06 06480-01 13620-93 08087-99 09054-05

1 1 1 1 1 1


6 Physical Chemistry 6.8 Atomic Structures and Properties

Basic principles in Nuclear Magnetic Resonance (NMR)

P5942100

Spin echo signal of an oil sample occuring 10 ms (echo time) after a 90° HF pulse (FID signal is shown). To generate the echo signal a 180° HF pulse has to be switched after half the echo time.

Principle

Main articles

The basic principles concerning the phenomenon of nuclear magnetic resonance (NMR) are demonstrated. Experiments are executed with a MRT training device giving the opportunity to investigate some small probes in the sample chamber. Device control is done with the provided software. Investigations comprise the tuning of the system frequency to the Larmor frequency, the determination of the flip angle of the magnetisation vector, the effects of the substance quantity, the influence of particular magnetic field inhomogeneities, the measurement of a spin echo signal and an averaging procedure to maximise the signal-to-noise ratio. The adjustment of all parameters in these experiments are inevitable to obtain an adequate MR image.

Compact magnetic resonance tomograph (MRT)

09500-99

1

Tasks 1. Tuning of the system frequency to the Larmor frequency. 2. Setting of the HF (High Frequency) pulse duration to determine the flip angle of the magnetisation vector. 3. Effects of the substance quantity on the FID signal (Free Induction Decay) amplitude. 4. Minimising magnetic field inhomogeneities via a superimposed magnetic field (shim). 5. Retrieving a relaxated FID signal via a spin echo flipping nuclear spins by 180°. 6. Improving the signal-to-noise ratio (SNR) of the FID signal. What cou can learn about ▪ ▪ ▪ ▪ ▪ ▪

Nuclear spins; Atomic nuclei with a magnetic moment Precession of nuclear spins; Magnetisation Resonance condition, MR frequency MR flip angle FID signal (Free Induction Decay); Spin echo Relaxation times (T1: longitudinal magnetisation, T2: transverse magnetisation); Signal-to-noise ratio

Felix Bloch (left) and Edward Mills Purcell (right) 1952, Nobel Prize in Physics

PHYWE Systeme GmbH & Co. KG · www.phywe.com 131


6 Physical Chemistry 6.8 Atomic Structures and Properties

P2210300

Dispersion and resolving power of a prism and a grating spectroscope

Dispersion curves of various substances.

Principle

Main articles

The refractive indices of liquids, crown glass and flint glass are determined as a function of the wave length by refraction of light through the prism at minimum deviation. The resolving power of the glass prisms is determined from the dispersion curve.

Spectrometer/goniom. w. vernier Power supply for spectral lamps Spectral lamp Hg 100, pico 9 base Hollow prism Lamp holder,pico 9,f.spectr.lamps Diffraction grating, 600 lines/mm Prism, 60 degrees, h.30 mm, crown

Tasks 1. To adjust the spectrometer-goniometer. 2. To determine the refractive index of various liquids in a hollow prism. 3. To determine the refractive index of various glass prisms. 4. To determine the wavelengths of the mercury spectral lines. 5. To demonstrate the relationship between refractive index and wavelength (dispersion curve). 6. To calculate the resolving power of the glass prisms from the slope of the dispersion curves. 7. Determination of the grating constant of a Rowland grating based on the diffraction angle (up to the third order) of the high intensity spectral lines of mercury. 8. Determination of the angular dispersion of a grating. 9. Determination of the resolving power required to separate the different Hg-Lines. Comparison with theory. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Maxwell relationship Dispersion Polarisability Refractive index Prism Rowland grating Spectrometer Goniometer

excellence in science 132

Spectrometer/goniom. w. vernier

Function and Applications Spectrometer/ goniometer with double vernier. Equipment and technical data ▪ With magnifying glasses ▪ 60° glass prism ▪ Illumination device and telescope 35635-02

35635-02 13662-97 08120-14 08240-00 08119-00 08546-00 08231-00

1 1 1 1 1 1 1


7 Inorganic Chemistry

Inorganic Chemistry 7.1 7.2 7.3 7.4 7.5

Chemistry of Metals Coordination Chemistry Organometallic Chemistry Solid-state Chemistry and Cristallography Literature

134 137 138 140 152

PHYWE Systeme GmbH & Co. KG · www.phywe.com 133


7 Inorganic Chemistry 7.1 Chemistry of Metals

P3110600

Redox reactions between metals and metal oxides (thermite process)

Experimental setup.

Principle The experiments described here are highly suitable for demonstrating the different affinity of various metals in view of oxygen. The less noble a metal is the higher its affinity to oxygen and the more thermal energy is released during its oxidation. The technical importance of the thermite process for the welding of iron parts is that it is relatively easy to produce large amounts of liquid iron and, thereby, to fill wider weld grooves. This is why this process is mainly used for welding thick steel beams, rail tracks, and machine parts. Tasks 1. Reduction of copper oxide with iron. 2. Reduction of iron oxide with aluminium (thermite process, aluminothermics). What you can learn about ▪ ▪ ▪ ▪

Redox reaction; Thermite process Metals; Welding of iron Aluminothermics Iron; Aluminium

Main articles Retort stand, h = 750 mm Iron powder xtra pure 1000 g Magnet, d 10mm, l = 200mm Teclu burner, DIN, natural gas Ignition sticks f. thermite, 50 pcs. Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

37694-00 30068-70 06311-00 32171-05 31921-05

1 1 1 1 1

49224-88

1

excellence in science 134


7 Inorganic Chemistry 7.1 Chemistry of Metals

Molten-salt electrolysis

P1310500

Oxidation/reduction process during the experiment.

Principle The electrolysis of molten sodium chloride to obtain chlorine and sodium, which can be further processed to produce sodium hydroxide, is an important industrial-scale process. The experiment depicted here can be used for a simple demonstration of the important steps in this process. Due to the high melting point of sodium chloride, however, lower-melting lead chloride is used as the raw material in the model experiment. Task

Related Experiments Oxidation of metals P1025200 Effects of acids on metals P3100100

Demonstration the electrolysis of molten sodium chloride to obtain chlorine and sodium.

Crystal-lattice model fluorite

What you can learn about ▪ ▪ ▪ ▪

Electrolysis Melt Chlorine Starch-iodine solution

Main articles Multimeter ADM2, demo., analoque Power supply, universal Frame for complete experiments Shelf with hanging device Wash tube with fritted disc Lead-II chloride 500 g Apparatus carrier w. fix. magnet

13820-00 13500-93 45500-00 45505-00 36699-00 31117-50 45525-00

1 1 2 1 1 1 1

Function and Applications High quality crystal-lattice model consisting of coloured wooden balls and metallic links; the model will be delivered completely fixed. 40018-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 135


7 Inorganic Chemistry 7.1 Chemistry of Metals

P3100400

Reduction of lead oxide

The blast furnance with which iron can be obtained from iron oxide.

Principle Lead oxide is reduced to lead; in the process the carbon is oxidised to carbon dioxide. ln this experimental set-up and also in the blast furnace process, the reducing agent proper is not carbon, but rather the carbon monoxide generated due to the oxygen deficit. Task

Lead Carbon monoxide Reduction Oxidation Redox reaction

Main articles 02001-00 31121-50 32165-05 30011-25 37701-01

1 1 1 1 1

02037-00 39281-10

1 1

excellence in science 136

P1026800

P1026900

What you can learn about

Support base variable Lead-II oxide -litharge- 500 g Bunsen burner DIN, natural gas Activated carbon, granular 250 g Ring with boss head, i. d. = 10 cm Support rod, stainless steel, l = 600 mm, d = 10 mm Safety gas tubing, DVGW, sold by metre

Reduction of silver oxide

Reduction of copper oxide

Demonstrate the reduction of lead oxide. ▪ ▪ ▪ ▪ ▪

Related Experiments


7 Inorganic Chemistry 7.2 Coordination Chemistry

Complex formation equilibrium / complex formation constant

P3031001

Determination of the number of ligands bound in the complex.

Principle

Molecular orbital models, organics

Many metals, in particular transition elements, can form complexes with charged or neutral ligands. Complex formation reactions are equilibrium reactions. The stability of these complexes is described by the complex formation constant. Tasks Determine the number of ligands of the silver amine complex with a precipitation titration from a silver salt solution. What you can learn about ▪ Complex formation ▪ Chemical equilibrium ▪ Equilibrium constant

Main articles Magnetic stirrer Mini / MST Silver nitrate, cryst. 15 g Retort stand, h = 750 mm Burette, lateral stopcock, Schellbach, 25 ml, graduations0,05 ml Burette clamp, roller mount., 2 pl. Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

47334-93 30222-00 37694-00

1 1 1

36506-01 37720-00

1 1

49224-88

1

Function and Applications The kit includes all the parts to build up 4 molecular orbital models of the following organic compounds: benzene, ethane, ethylene and acetylene. Benefits The models show bonding s- and p- orbitals. The concept of hybridisation and delocalisation can be demonstrated so well. 39837-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 137


7 Inorganic Chemistry 7.3 Organometallic Chemistry

P3101000

Haloalkanes: Grignard reagent

Set-up to determine the molar mass of the gas that is produced during the reaction.

Principle Haloalkanes react with magnesium to the so-called Grignard reagents in accordance with the general formula RMgX. With X = bromide or iodide, the reaction works best. Chlorides are usually more inert and require higher temperatures and longer reaction times for the conversion. The compounds that were discovered by Victor Grignard probably exist as dimeric structures. Task Investigate the reaction of n-propyl bromide with magnesium turnings in tetrahydrofuran. What you can learn about ▪ ▪ ▪ ▪ ▪

n-propyl bromide Magnesium Haloalkanes Grignard reagent Organometallic compounds

Main articles Gasometer 1000 ml Weather monitor, 6 lines LCD Condenser, Dimroth type GL25/12 Magnetic stirrer Mini / MST Separating funnel, 50 ml, GL18 Funnel f. gas generator, 50 ml, GL18 Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

40461-00 87997-10 35815-15 47334-93 35853-15 35854-15

1 1 1 1 1 1

49224-88

1

François Auguste Victor Grignard 1912, Nobel Prize in Chemistry

excellence in science 138


7 Inorganic Chemistry 7.3 Organometallic Chemistry

Haloalkanes: Wurtz reaction - lithium organyls

P3101100

Reaction of lithium with ethyl iodide and the following Wurtz reaction of ethyl lithium with ethyl iodide.

Principle

Gasometer 1000 ml

Unlike the other alkali-organyls, lithium organyls - with the exception of methyllithium - show a stronger covalent behaviour. They dissolve rather well in organic solvents, such as diethyl ether, tetrahydrofuran, and alkanes, and they are relatively stable in these solvents. Wurtz synthesis was developed in 1854 for the preparation of higher alkanes based on haloalkanes. Alkyl iodides react the easiest. The reaction can be controlled best with lithium, since the other alkali metals react much more violently. Wurtz synthesis is often a side reaction that occurs during organometallic conversions. Task Investigate the reaction of ethyl iodide with lithium and the following reaction of ethyllithium with ethyl iodide. What you can learn about ▪ Alkali-organyls; Lithium organyls ▪ Wurtz synthesis; Organometallic compounds

Main articles Gasometer 1000 ml Weather monitor, 6 lines LCD Condenser, Dimroth type GL25/12 Gasket for GL25, 8 mm hole, 10 pcs. Retort stand, h = 750 mm Round bottom flask, 100 ml, GL25/12, GL 18/8 Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

40461-00 87997-10 35815-15 41242-03 37694-00

1 1 1 1 1

35842-15

1

▪ Content 1000 ml ▪ Adjustable outer scale ▪ Readability 10 ml

49224-88

1

40461-00

Function and Applications Gasometer. Equipment and technical data

PHYWE Systeme GmbH & Co. KG · www.phywe.com 139


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

excellence in science 140


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

PHYWE Systeme GmbH & Co. KG · www.phywe.com 141


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

excellence in science 142


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

Examination of the structure of NaCl monocrystals with different orientations

P2541301

Intensity of the X-ray spectrum of copper as a function of the glancing angle theta: NaCl monocrystals with [111] crystal orientation as Bragg analyser.

Principle The spectra of the X-rays that are reflected with various different orientations by NaCl monocrystals are analysed. The associated interplanar spacings are determined based on the Bragg angles of the characteristic lines. Tasks 1. Determine the intensity of the X-rays that are reflected by the NaCl monocrystals with the orientations [100], [110], and [111] as a function of the Bragg angle. 2. Assign the reflections to the corresponding lattice planes that are given by way of their respective Miller indices. 3. Determine the lattice constant and calculate the interplanar spacing. 4. Determine the mass of a cell and the number of atoms in the cell.

Best fitting X-ray sets for this experiment: XRE 4.0 X-ray expert set 09110-88 XRS 4.0 X-ray structural analysis upgrade set 09140-88

What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Characteristic X-radiation Energy levels Crystal structures Reciprocal lattices Miller indices Atomic form factor Structure factor Bragg scattering

Main articles XR 4.0 expert unit XR 4.0 X-ray goniometer XR 4.0 X-ray Plug-in Cu tube XR 4.0 X-ray NaCl-monocrystals, set of 3 XR 4.0 Software measure X-ray Geiger-Mueller Counter tube, type B

09057-99 09057-10 09057-50 09058-01 14414-61 09005-00

1 1 1 1 1 1

Sir William Henry Bragg (left) and Sir William Lawrence Bragg (right) 1915, Nobel Prize in Physics

PHYWE Systeme GmbH & Co. KG · www.phywe.com 143


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

P2541401

X-ray investigation of cubic crystal structures / Debye- Scherrer powder method

Debye-Scherrer pattern of a powdered sample of NaCl. Thickness of the sample: 0.4 mm. Exposure time: 2.5 h. Mo X-ray tube: Ua = 35 kV; Ia = 1 mA

Principle When polycrystalline samples are irradiated with X-rays a characteristic diffraction pattern results. These Debye-Scherrer reflections are photographed and then evaluated. Tasks 1. Debye-Scherrer photographs are to be taken of powdered samples of sodium chloride and caesium chloride. 2. The Debye-Scherrer rings are to be evaluated and assigned to the corresponding lattice planes. 3. The lattice constants of the sample materials are to be determined. 4. The number of atoms in the unit cells of each sample are to be determined.

Related Experiment X-ray investigation of hexagonal crystal structures / Debye-Scherrer powder method P2541501

Best fitting X-ray sets for this experiment: XRE 4.0 X-ray expert set 09110-88

What you can learn about ▪ ▪ ▪ ▪ ▪

XRS 4.0 X-ray structural analysis upgrade set

Crystal lattices; Crystal systems Reciprocal lattice; Miller indices Structure amplitude Atomic form factor Bragg scattering

09140-88

Main articles XR 4.0 expert unit XR 4.0 X-ray Plug-in Mo tube XR 4.0 X-ray film holder XR 4.0 X-ray optical bench XR 4.0 X-ray films, wet chemical, 100 pieces, 100 × 100 mm XR 4.0 X-ray Diaphragm tube d = 1 mm Slide mount for optical bench, h = 30 mm

09057-99 09057-60 09057-08 09057-18

1 1 1 1

09058-23 09057-01 08286-01

1 1 1

excellence in science 144


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

X-ray investigation of crystal structures / Laue method with digital X-ray image sensor (XRIS)

P2541602

Laue pattern of the LiF (100) crystal.

Principle Laue diagrams are produced when monocrystals are irradiated with polychromatic X-rays. This method is primarily used for the determination of crystal symmetries and the orientation of crystals. When a LiF monocrystal is irradiated with polychromatic Xrays, a characteristic diffraction pattern results. This pattern is photographed with the digital X-ray sensor XRIS. Tasks 1. The Laue diffraction of an LiF mono-crystal is to be recorded on a film. 2. The Miller indices of the corresponding crystal surfaces are to be assigned to the Laue reflections

Related X-ray Experiment X-ray investigation of crystal structures / Laue method P2541601

Best fitting X-ray sets for this experiment: XRE 4.0 X-ray expert set 09110-88

What you can learn about ▪ Crystal lattices; Crystal systems; Crystal classes ▪ Bravais lattice; Reciprocal lattice; Miller indices ▪ Structure amplitude; Atomic form factor; The Bragg equation

XRCT 4.0 X-ray Computed Tomography upgrade set 09180-88

Main articles XR 4.0 X-ray Direct Digital Image Sensor (XRIS) with USB cable XR 4.0 expert unit XR 4.0 Software measure CT XR 4.0 X-ray plug-in unit W tube XR 4.0 X-ray Lithium fluoride crystal, mounted XR 4.0 X-ray optical bench XR 4.0 X-ray Crystal holder for Laue-pattern

09057-40 09057-99 14421-61 09057-80

1 1 1 1

09056-05 09057-18 09058-11

1 1 1

Max von Laue 1914, Nobel Prize in Physics

PHYWE Systeme GmbH & Co. KG · www.phywe.com 145


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

P2542101

Debye-Scherrer diffraction patterns of powder samples with three cubic Bravais lattices (Bragg-Brentano-geometry)

Bragg-Cu-Kα and Cu-Kβ-lines of Mo.

Principle

Main articles

Polycrystalline powder samples, which crystallize in the three cubic Bravais types, simple, face-centered and body-centered, are irradiated with the radiation from a Roentgen tube with a copper anode. A swivelling Geiger-Mueller counter tube detects the radiation that is constructively reflected from the various lattice planes of the crystallites. The Bragg diagrams are automatically recorded. Their evaluation gives the assignment of the Bragg lines to the individual lattice planes, their spacings as well as the lattice constants of the samples, and so also the corresponding Bravais lattice type.

XR 4.0 expert unit XR 4.0 X-ray goniometer XR 4.0 X-ray Plug-in Cu tube XR 4.0 Software measure X-ray Geiger-Mueller Counter tube, type B XR 4.0 X-ray Lithium fluoride crystal, mounted Molybdenum, Powder, 99,7%, 100 g

09057-99 09057-10 09057-50 14414-61 09005-00

1 1 1 1 1

09056-05 31767-10

1 1

Tasks 1. Record the intensity of the Cu X-rays back scattered by the four cubic crystal powder samples with various Bravais lattice types as a function of the scattering angle. 2. Calculate the lattice plane spacings appropriate to the angular positions of the individual Bragg lines. 3. Assign the Bragg reflections to the respective lattice planes. Determine the lattice constants of the samples and their Bravais lattice types. 4. Determine the number of atoms in the unit cell. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Crystal lattices Crystal systems Bravais-lattice Reciprocal lattice Miller indices Structure factor Atomic scattering factor Bragg scattering Characteristic X-rays Monochromatisation of X-rays Bragg-Brentano Geometry

excellence in science 146

Related Experiments Debye-Scherrer diffractions pattern of powder samples with a diamond structure (according to Bragg-Brentano) P2542201 Debye-Scherrer diffraction patterns of powder samples with a hexagonal lattice structure P2542301 Debye-Scherrer diffraction patterns of powder samples with a tetragonal lattice structure P2542401 Debye-Scherrer diffraction patterns with a cubic powder sample P2542501


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

Debye-Scherrer diffractions pattern of powder samples with a diamond structure (according to Bragg-Brentano)

P2542201

Bragg-Cu-Kα and Cu-Kβ lines of germanium powder

Principle Polycrystalline powder samples, which crystallize in the three cubic Bravais types, simple, face-centered and body-centered, are irradiated with the radiation from a Roentgen tube with a copper anode. A swivelling Geiger-Mueller counter tube detects the radiation that is constructively reflected from the various lattice planes of the crystallites. The Bragg diagrams are automatically recorded. Their evaluation gives the assignment of the Bragg lines to the individual lattice planes, their spacings as well as the lattice constants of the samples, and so also the corresponding Bravais lattice type.

Geiger-Mueller counter tube, type B XR 4.0 X-ray Lithium fluoride crystal, mounted Germanium, Powder, 99%, 10 g

09005-00

1

09056-05 31768-03

1 1

Tasks 1. Record the intensity of the Cu X-rays back scattered by the four cubic crystal powder samples with various Bravais lattice types as a function of the scattering angle. 2. Calculate the lattice plane spacings appropriate to the angular positions of the individual Bragg lines. 3. Assign the Bragg reflections to the respective lattice planes. Determine the lattice constants of the samples and their Bravais lattice types. 4. Determine the number of atoms in the unit cell. What you can learn about ▪ ▪ ▪ ▪ ▪

Crystal lattices; Crystal systems; Bravais-lattice Reciprocal lattice; Miller indices; Structure factor Atomic scattering factor; Bragg scattering Characteristic X-rays; Monochromatization of X-rays Bragg Brentano geometry

Main articles XR 4.0 expert unit XR 4.0 X-ray goniometer XR 4.0 X-ray Plug-in Cu tube XR 4.0 Software measure X-ray

09057-99 09057-10 09057-50 14414-61

1 1 1 1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 147


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

P2532000

Atomic Resolution of the graphite surface by STM (Scanning Tunneling Microscope)

Atomic resolved image of the graphite surface (5nm x 5nm).

Principle Approaching a very sharp metal tip to an electrically conductive sample by applying a electrical field leads to a current between tip and sample without any mechanical contact. This so-called tunneling current is used to investigate the electronic topography on the sub nanometer scale of a fresh prepared graphite (HOPG) surface. By scanning the tip line-by-line across the surface graphite atoms and the hexagonal structure are imaged. Tasks 1. Prepare a Pt-Ir tip and the graphite (HOPG) sample and approach the tip to the sample. 2. Investigate the topography of clean terraces and the step height between neighboring terraces in constant-current mode. 3. Image the arrangement of graphite atoms on a clean terrace by optimize tunneling and scanning parameters. Interpret the structure by analyzing angles and distances between atoms and atomic rows and by using the 2D and 3D graphite model. 4. Measure and compare images in the constant-height and constant-current mode. What you can learn about ▪ ▪ ▪ ▪ ▪

Tunneling effect; Hexagonal Structures Scanning Tunneling Microscopy (STM) Imaging on the sub nanometer scale Piezo-electric devices; Local Density Of States (LDOS) Constant-Height-Mode; Constant-Current-Mode

Main articles Compact-Scanning Tunneling Microscope (STM) Crystal lattice kit: graphite Graphite model, 2D

09600-99 39840-00 09620-00

excellence in science 148

1 1 1

Heinrich Rohrer (left) and Gerd Binnig (right) 1986, Nobel Prize in Physics


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

Compact-Scanning Tunneling Microscope (STM)

▪ DA converter for all three dimensions, up to 7 measurement channels, and maximum scanning speed of 60 ms/ line ▪ Scan head cover with magnif. lense: 10x ▪ Toolset for preparing and mounting tunneling tips: side-cutter, tong and tweezers ▪ Pt-Ir wire for tunneling tips: length 30 cm, diameter 0.25 mm ▪ Sample kit: Graphite (HOPG), Gold(111) films, and 4 spare sample supports ▪ Power supply (100-240 V, 50/60 Hz) ▪ USB cable: length 3 m; Aluminium case (44 cm x 32 cm x 14 cm) ▪ Software for measuring, analysing and visualisation (one, two, and three dimensions) ▪ Handbook incl. short description of starting experiments with HOPG and gold films; Quick Installation Guide; Weight (incl. case) 6.7 kg Accessories

Function and Applications Easy to use scanning tunneling microscope to image conducting surfaces and to investigate effects and characteristics on atomic and molecular scale. A variety of experiments in the fields of Material Sciences, Solid State Physics/Chemistry, Nanotechnology and Quantum Mechanics can be performed. For example: microand nano morphology of surfaces, nano structures, imaging of atoms and molecules, conductivity, tunneling effect, charge density waves, single molecule contacts, and nanostructuring by self organisation (self assembled monolayers). Benefits ▪ Out-of-the-box-device incl. all necessary accessories for a prompt entry into the world of atoms and molecules. ▪ Portable and compact: transportable, easy to install with a small footprint. ▪ Single device for more stable measurements. ▪ Quick atomic resolution on a normal table. No need for expensive vibration isolation. ▪ Easy to use: Ideal for nanotechnology education, preparing students for their work on high-level research devices, and outreach. ▪ Accessible sample stage and scanning tip: Quick exchange of tip and sample. ▪ Low operating voltage: Safe for all users. Equipment and technical data ▪ Scan head with integrated control-unit on vibration-isolated experimentation board: ▪ Maximum scan range (XY) 500 nm x 500 nm ▪ Maximum Z-range 200 nm ▪ Resolution in XY better than 8 pm ▪ Resolution in Z better than 4 pm ▪ Current 0.1-100 nA in 25 pA steps ▪ Tip voltage +/-10 V in 5 mV steps ▪ Dimensions 21 cm x 21 cm x 10 cm ▪ Constant-Current Mode ▪ Constant-Height Mode ▪ Current-Voltage Spectroscopy ▪ Current-Distant Spectroscopy ▪ Control-Unit with USB socket, 16-Bit

▪ Computer with Windows 2000/XP/Vista/7, USB interface, 256MB RAM, 1024x758 graphics card, 16-bit colour resolution or better ▪ other samples ▪ electrical conductive adhesive for mounting own samples ▪ ethanol and cloth for cleaning 09600-99

Set samples nanomorphology, for Compact Scanning Tunneling Microscope (STM) 09613-00

Left: Charge density waves onTaS2, 6nm Right: Gold film, 560nm

Left: 2D- melecular crystal (octadecanol) on graphite (HOPG), 13nm Right: Graphite (HOPG), atomic resolution, 2nm

PHYWE Systeme GmbH & Co. KG · www.phywe.com 149


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

P2538000

Basic methods in imaging of micro and nanostructures with atomic force microscopy (AFM)

Topography of Microstructure (50 micrometer), CD Stamper (20 micrometer), Skin Cross-Section (60 micrometer), and SCA Chip Structure (40 micrometer) FLTR.

Principle Approaching a sharp silicon tip mounted on a cantilever to a sample surface leads to an atomic scale interaction. The result is a bend of the cantilever which is detected by a laser. In static mode the resulting deflection is used to investigate the topography of the sample surface line-by-line using a feedback loop. In dynamic mode the cantilever is oscillated at fixed frequency resulting in a damped amplitude near the surface. The measurement parameters (setpoint, feedback gain,…) play a crucial role for image quality. The dependence on the imaging quality is investigated for different nano structured samples. Tasks 1. Set-up the microscope and start up the software. Mount a cantilever (with tip) and approach the tip towards a sample. 2. Investigate the influence of the scanning parameters on the imaging quality and performance, e.g. PID gain, setpoint (force), vibrational amplitude, and scanning speed. Use both static and dynamic force mode. 3. Image 7 different samples (microstructures, carbon nano tubes, skin cross-section, bacteria, CD stamper, chip structure, glass beads) by optimizing the parameters respectively. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Atomic Force Microscopy (AFM) Lennard-Jones potential Imaging of nano structures Static Force Mode; Dynamic Force Mode Feedback Loop; Force Vibrational Amplitude

Main articles Compact-Atomic Force Microscope (AFM)

09700-99

excellence in science 150

1

Related Experiment Imaging of biological and medical micro and nanostructure with atomic force microscopy (AFM) P2538400


7 Inorganic Chemistry 7.4 Solid-state Chemistry and Cristallography

Compact-Atomic Force Microscope (AFM)

▪ Available with upgrade options material and spectroscopy and manipulation ▪ User expandability (scripting) available (upgrade option); Set of 10 Cantilever, 6 samples, Toolset ▪ Software for measuring, manipulation, analysing and visualization, Handbook and Quick Installation Guide Accessories

Function and Applications Compact and easy to use atomic force microscope to visualize and image structures on the micro and nano meter scale. Developed for educational purposes in practical lab course and pre-research labs in physics, chemistry, life sciences and material sciences. Also suitable to determine material characteristics (e.g. stiffness, magnetization, charging, material and phase contrast) and for manipulation (e.g. lithography).

▪ Material upgrade (Art. 09701-00): Additional Operating Modes (Phase Contrast, EFM, MFM, Force ▪ Modulation, Spreading Resistance), set of samples and cantilevers ▪ Spectroscopy and Manipulation upgrade (Art. 09702-00): Additional Operating Modes (Advanced Spectroscopy, Lithography (scratching, oxidation), Manipulation (oxidation, cutting and moving/pushing of nanoparticles)), User expandability (Visual basic, LabView, etc.), set of cantilevers and samples ▪ Side View Camera System (available 2013), other samples 09700-99

Benefits ▪ Out-of–the-box device with integrated damping plate and control unit underneath ▪ Complete set, incl. Sample Set, Cantilever, Tools and Consumables ▪ Tip Scanner AFM for standard cantilever ▪ Easy and safe cantilever exchange and use: Flip mechanism with automatic laser switch off, no laser alignement, mechanical stopper for longer lifetime of cantilevers ▪ Digital top view camera for easy positioning and side view lens for easy and fast approach ▪ Portable and compact: Transportable, easy to install with a small footprint ▪ Easy to use: Ideal for nanotechnology education, preparing students for their work on high-level research devices, and outreach

Staphylococcus Bacteria, 10 μm m and Skin Cross-Section, 60 60μm m

Equipment and technical Data ▪ Scan head with integrated control-unit on vibration-isolated experimentation board: 21 cm x 21 cm x 18 cm, USB 2.0 interface, 16 bit DA converter (XYZ), 16 bit AD converter ( 7 channels) ▪ Max scanning speed 60 ms/line, up to 2048x2048 data points ▪ Scan type (tip scanner): Linear low voltage electro magnetic ▪ Scan Range: 70 micro meter (1.1 nm resolution) ▪ Z-range: 14 micro meter (1.1 nm resolution); Z noise level (RMS): 0.6 / 0.5 nm (static / dynamic); Automatic approach: vertical, range 4.5 mm ▪ Sample: max. 13 mm in diameter, horizontal mount, LED illumination, Micrometer translation stage xy: min. +/- 5 mm ▪ Cantilever Aligment: automatic adjustment, alignment grooves from various suppliers; Camera system for top view: USB digital color, 3.1 M pixels ▪ Modes of operation: Static Force, Dynamic Force, Force Distance Spectroscopy, Amplitude Distance Spectroscopy ▪ Other modes (MFM, AFM, Phase contrast, lithography and advanced spectroscopy modes)

CD Stamper, 20 μm m and Aluminum foil, 60 μm m

PS/PMMA films: Topography and Phase Contrast, 3 μm m

PHYWE Systeme GmbH & Co. KG · www.phywe.com 151


7 Inorganic Chemistry 7.5 Literature

Handbook Physics X-Ray Experiments

the experiment at the push of a button as well as numerous example measurements. ▪ Experiment matrix for quick orientation. ▪ Operating instructions concerning the components of the XR 4.0 platform including detailed information. ▪ DIN A4 format, spiral-bound, colour print. This documentation contains the following experiments: Counter tube characteristics P2540010 Radiographic examination of objects P2540020 Qualitative examination of the absorption of X-rays P2540030 Ionising effect of X-radiation P2540040 Characteristic X-rays of copper P2540101 Characteristic X-rays of iron P2540301 The intensity of characteristic X-rays as a function of the anode current and anode voltage P2540401

Article no. 01200-02 Experiments with X-rays and their use in physics, chemistry, biology, medicine, material science, and geology. Description Comprehensive collection of reference experiments concerning the fundamental principles and use of X-rays in physics, chemistry, biology, medicine, material science, and geology with the XR 4.0 X-ray unit platform as a pool of ideas concerning the potential areas of application in demonstration and laboratory experiments. A clear matrix simplifies the orientation in terms of scientific fields and topics. Topics ▪ Characteristic X-radiation / atomic structure / quantum physics and chemistry ▪ X-ray absorption ▪ Compton scattering ▪ Dosimetry ▪ Crystal structures/structural analysis with X-rays/Debye-Scherrer experiments (counting tube goniometer) ▪ Transirradiation experiments/non-destructive testing Features ▪ Experiment descriptions with clearly structured learning objectives, fundamental principles, photo of the setup, equipment list, tasks, illustrated instructions concerning the setup and procedure, theory and evaluation with example results plus important notes concerning the operation and safety of the equipment. This simplifies the orientation and execution as well as the selection of the experiment parts for personalised laboratory experiments. The information provided is so comprehensive that no other background information is required. ▪ For every experiment, the software package "XRM 4.0 measure X-ray" includes presettings for the easy and direct execution of

excellence in science 152

Monochromatisation of molybdenum X-rays P2540501 Monochromatisation of copper X-rays P2540601 K alpha double splitting of molybdenum X-rays/ fine structure P2540701 K alpha doublet splitting of iron X-rays / fine structure P2540801 Duane-Hunt displacement law and Planck's "quantum of action" P2540901 Absorption of X-rays P2541101 K and L absorption edges of X-rays / Moseley's law and the Rydberg constant P2541201 Examination of the structure of NaCl monocrystals with different orientations P2541301 X-ray investigation of cubic crystal structures / Debye- Scherrer powder method P2541401 X-ray investigation of hexagonal crystal structures / DebyeScherrer powder method P2541501 Compton scattering of X-rays P2541701 Complete experiment list see: www.phywe.com 01200-02


8 Organic Chemistry

Organic Chemistry 8.1 8.2

Organic Synthesis Distillation, Purification

154 160

PHYWE Systeme GmbH & Co. KG · www.phywe.com 153


8 Organic Chemistry 8.1 Organic Synthesis

P3101100

Haloalkanes: Wurtz reaction - lithium organyls

Reaction of lithium with ethyl iodide and the following Wurtz reaction of ethyl lithium with ethyl iodide.

Principle Unlike the other alkali-organyls, lithium organyls - with the exception of methyllithium - show a stronger covalent behaviour. They dissolve rather well in organic solvents, such as diethyl ether, tetrahydrofuran, and alkanes, and they are relatively stable in these solvents. Wurtz synthesis was developed in 1854 for the preparation of higher alkanes based on haloalkanes. Alkyl iodides react the easiest. The reaction can be controlled best with lithium, since the other alkali metals react much more violently. Wurtz synthesis is often a side reaction that occurs during organometallic conversions.

Molecular model constuction kit, polymer chemistry

Task Investigate the reaction of ethyl iodide with lithium and the following reaction of ethyllithium with ethyl iodide.

Function and Application With these big elements (Atoms) for molecular models structures of chemical compounds can be presented especially vividly also to a greater number of observers.

What you can learn about ▪ Alkali-organyls; Lithium organyls ▪ Wurtz synthesis; Organometallic compounds

Benefits

Main articles Gasometer 1000 ml Weather monitor, 6 lines LCD Condenser, Dimroth type GL25/12 Gasket for GL25, 8mm hole, 10 pcs. Retort stand, h = 750 mm Round bottom flask, 100 ml, GL25/12, GL18/8 Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

40461-00 87997-10 35815-15 41242-03 37694-00

1 1 1 1 1

35842-15

1

49224-88

1

39818-88

excellence in science 154

▪ Structural elements of shockproof plastic (robust). ▪ Diameter of the elements: 38 mm (ostentatious). ▪ Chemical elements characterised by internationally usual colours. ▪ Angularity of the connections by precisely rivetted push-buttons according to the valences of the elements. ▪ Transparent connectors: straight for single bonds and curved for double and triple bonds.


8 Organic Chemistry 8.1 Organic Synthesis

Toluene: Bromination in the nucleus

P3101300

Reaction mechnism of the bromination of toluene.

Principle

Molecular orbital models, organics

Bromine is polarised and, thereby, activated by zinc chloride as a Lewis acid. It can attach itself in an ionic manner to the toluene nucleus via several complex intermediate stages. Following a dehydrobromination, bromotoluene is formed, i.e. the product of bromination in the nucleus. In the absence of a catalyst and under the influence of light, however, side-chain bromination takes place via radical intermediate stages. The reaction can be controlled in a targeted manner by varying the reaction conditions. Tasks 1. Brominate toluene using bromine. 2. Change the reaction conditions to optimise your results. 3. Distillate the resulting mixture. What you can learn about ▪ ▪ ▪ ▪ ▪

Bromine Toluene Lewis acid Bromination Distillation

Function and Applications The kit includes all the parts to build up 4 molecular orbital models of the following organic compounds: benzene, ethane, ethylene and acetylene. Benefits

Main articles Magnetic stirrer MR Hei-Standard Sec.bottle500ml,2xGl18/8,1x25/12 Separating funnel,50ml,GL18 Liebig Condenser, with head, GL18/8 Lab jack, 200 x 230 mm Silicone oil 500 ml

35750-93 34170-01 35853-15 35795-15 02074-01 31849-50

1 1 1 1 1 1

▪ The models show bonding s- and p- orbitals. ▪ The concept of hybridisation and delocalisation can be demonstrated so well. 39837-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 155


8 Organic Chemistry 8.1 Organic Synthesis

P3101400

Aldehydes - reactions with ammonia

Reaction of aldehyde with ammonia.

Principle When a formaldehyde and ammonia solution mixture is concentrated a solid white substance results. Ammonia reacts with formaldehyde (methanal) to hexamethylenetetramine. Tasks 1. Addition of ammonia to acetaldehyde and benzaldehyde. 2. Preparation of hexamethylenetetramine (urotropine). What you can learn about ▪ ▪ ▪ ▪

Ammonia Formaldehyde urotropine Hexamethylenetetramine Hydrolysis

Main articles Funnel for gas generator, 50 ml, GL18 Lab jack, 160 x 130 mm U tube, 2 side tubes, GL25/8 Quartz glass wool 10 g Teclu burner, DIN, natural gas Test tube GL25/8, with hose connection

35854-15 02074-00 36959-15 31773-03 32171-05 36330-15

excellence in science 156

1 1 1 1 1 2


8 Organic Chemistry 8.1 Organic Synthesis

Preparation of p-toluenesulfonic acid

P3101500

Reaction of toluene with sulfonic acid.

Principle

Water separator GL25/12

This is a model experiment to show the industrial blast furnace process to produce iron from iron(III) oxide. During the experiment a furnace gas flame that is approximately 10 to 20 cm high can be ignited at the stack outlet. Cavities form in the burning carbon layer. These cavities collapse over time. Apart from ash and carbon residues, metallic lumps can also be found in the frame after the end of the experiment. Samples of these lumps lead to the formation of hydrogen when they are treated with hydrochloric acid. Tasks 1. Investigate the reduction fo iron(III) oxide to iron(II) oxide. 2. Show the blast furnace process in a model experiment. What you can learn about ▪ Iron; Blast furnace process ▪ Slug; Production of iron ▪ Reduction; Oxidation

Function and Applications Water separator to separate two non-miscible liquids with different densities.

Main articles Heating mantle for roundbottom flask, 100 ml, 230 V,with safety switch Desiccator, wertex, diam. 150 mm Condenser, Dimroth type GL25/12 Power regulator Water separator GL25/12 Retort stand, h = 750 mm

49541-93 34126-00 35815-15 32288-93 35790-15 37694-00

1 1 1 1 1 1

Equipment and technical data ▪ ▪ ▪ ▪

Made of DURAN® With glass cock and GL 25/12 connection and connecting pipe Diameter connecting pipe: 12 mm Graduated; Content: 5 ml

35790-15

PHYWE Systeme GmbH & Co. KG · www.phywe.com 157


8 Organic Chemistry 8.1 Organic Synthesis

P3101600

Cannizzaro reaction and reaction of benzaldehyde with ethylene glycol

Reaction mechanism of the disproportion of benzaldehyde to benzyl alcohol and benzoic acid.

Principle

Abbe refractometer

In the first part of the experiment, benzaldehyde disproportionates under the effect of alkalis to alcohol-soluble benzyl alcohol and water-soluble benzoic acid that precipitates when the aqueous solution is acidified. In the second part, benzaldehyde reacts with ethylene glycol to form a cyclic acetal. This ethylene acetal is resistant against basic and oxidising reagents. In an acid medium, it once again splits up into its original products. It is because of these characteristics that cyclic acetals are used for blocking the carbonyl function in preparative, organic chemistry. Tasks 1. Show the Cannizzaro reaction of benzaldehyde under basic conditions. 2. Prepare benzaldehyde ethylene acetal from benzaldehyde with ethylene glycol. What you can learn about ▪ Cannizzaro reaction; Benzaldehyde ▪ Acetals; Distillation; Micro distillation

Main articles Abbe refractometer Immersion thermostat Alpha A, 230 V Heating mantle for roundbottom flask, 250 ml, 230 V, with saftey switch Heating mantle for roundbottom flask, 100 ml, 230 V, with safety switch Condenser, Dimroth type GL25/12 Sec.bottle500ml, 2x Gl18/8,1x 25/12 Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35912-00 08493-93

1 1

49542-93

1

49541-93 35815-15 34170-01

1 1 1

49224-88

1

Function and Applications

excellence in science 158

Abbe refractometer for measuring the refraction index of liquids and solids with light of 590 nm wavelength (sodium D line) and determining average dispersion nC-nF. The refractive index scale also includes an additional scale indicating sugar content from 0 - 95 %. The prism and scales can be illuminated by daylight or by a separate lighting unit. 35912-00


8 Organic Chemistry 8.1 Organic Synthesis

Haloalkanes: Grignard reagent

P3101000 Principle Haloalkanes react with magnesium to the so-called Grignard reagents in accordance with the general formula RMgX. With X = bromide or iodide, the reaction works best. Chlorides are usually more inert and require higher temperatures and longer reaction times for the conversion. The compounds that were discovered by Victor Grignard probably exist as dimeric structures.

For more details refer to page 138.

Electrophilic addition of bromine to acetylene (ethyne)

P3120500

Principle Like an olefin, ethyne adds bromine to the trans-1,2-dibromoethene by way of a bromonium ion. Under the given circumstance, further bromine can be added to the trans-1,2-dibromoethene to form 1,1,2,2-tetrabromoethane. The tetrabromoethane is the stable final product of this reaction. The cis-1,2-dibromoethene can result from ethyne as a byproduct as well as from the tetrabromoethane as a result of dehalogenation. Three peaks can be distinguished in the gas chromatogram.

For more details refer to www.phywe.com

PHYWE Systeme GmbH & Co. KG · www.phywe.com 159


8 Organic Chemistry 8.2 Distillation, Purification

P3031501

Rectification - the number of theoretical trays in a distillation column

Equilibrium diagram.

Principle The separation power of a rectification (fractionating) column can be determined using an appropriate binary mixture whose equilibrium composition is measured in the distillation flask and in the domed glass head of the distillation apparatus. The number of theoretical trays can be numerically or graphically obtained from the measured values.

Related Experiment Fractional distillation with the bubble tray column (with Cobra3) P3031640

Tasks 1. Prepare 10 mixtures of methyl cyclohexane and n-heptane with substance ratios (mole fractions) from 0 to 1 and with step width of approximately 0.1. To record a calibration curve, determine the refractive indices of the mixtures and plot them against the mole fractions. 2. Distill a mixture of methyl cyclohexane and n-heptane in a rectification column with total reflux until an equilibrium has been established. Determine the composition of the condensate and the number of theoretical trays in the column for a throughput of 500 and 1000 ml/h. What you can learn about ▪ Bubble tray column; Rectification ▪ Raoult's law; Henry's / Dalton's law ▪ Boiling-point diagram; Reflux ratio

Main articles Set rectification plant, 230 V Abbe refractometer Data acquisitation set for set rectification plant, 230 V Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

35918-88 35912-00

1 1

35918-50

1

49224-88

1

excellence in science 160

Set rectification plant, 230 V Function and Applications Distillation plant with a height of 235 cm to the demonstration and processing the principles of countercurrent-distillation (phase equilibrium of muticomponent systems) or to the preparative separation of mixtures difficult to separate Benefits This set allows to execute the measurements in a didactical clear and easy way: ▪ Complete insight into all running processes, because all components have an evacuated, but not silvered isolating-coat ▪ High separation efficiency through 2 large packed columns ( h = 400 mm); Simple withdrawal of samples through 2 column intermediate pieces ▪ Secure, because the high-efficiency condensor of the column head also condense high-volatile liquids ▪ Simple adjustment of thereflux ratio's through onehand-controlled column head 35918-88


8 Organic Chemistry 8.2 Distillation, Purification

Steam distillation

P3031251

Orange peel and cloves are both very suitable for winning ethereal oils.

Principle

Heating apparatus for glass jacket system

An elegant and simple apparatus for carrying out water vapour distillations: the advantage of this arrangement is that it eliminates the need for a separate vapour generator, making it possible to operate with a single heat source (other set-ups require two). The vapour is generated in the outer chamber and then passes through the inner chamber. Due to the structural arrangement, the inner chamber is heated directly by the vapour generated in the outer chamber. This also eliminates the possibility of overheating the substances being extracted. Parts of plants suitable for the extraction of essential oils include orange peel and cloves, for example. Task Extract ethereal oils from parts of plants e g. orange peel and cloves using steam distillation. What you can learn about ▪ ▪ ▪ ▪

Distillation Steam distillation Etheral oils Flavour

Hot plate. For a uniform and hence material protecting heating of cylindrical bodies or devices made of metal, ceramic or glass. Equipment and technical data

Main articles Glass jacket Heating apparatus for glass jacket system Power regulator Lab jack, 160 x 130 mm Insert w.ext.tube f.glass jack. Cooling jacket, GL 25/8

Function and Applications

02615-00 32246-93 32288-93 02074-00 02615-06 34880-01

1 1 1 1 1 1

▪ ▪ ▪ ▪ ▪

Power requirement 500 W max. Surface temperature 500 °C Mains supply: 230 V, 50...60 Hz Dimensions (mm): 160 x 95 x 90 mm Items suitable for heating: minimum length: 130 mm, diameter: 36...100 mm

32246-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 161


8 Organic Chemistry 8.2 Distillation, Purification

P1308962

Distillation - determination of the alcohol content of wine (with Cobra4)

Content of wine: 82 % water, 11 % ethanol, 4 % sugar and glycerol, 2 % acids and salts, 1 % rest.

Principle If the alcohol content of a wine is determined directly with an alcohol meter (hydrometer), the resulting alcohol content reading is approximately 0% by volume. This is due to the composition of the wine. The effect of the alcohol on the density is cancelled out by other components such as sugars, acids, essential oils, etc.. For this reason, in order to determine alcohol content by density, the alcohol must be separated out by means of distillation prior to the determination. This corresponds to the official method which currently applies for measuring alcohol in wines. First the wine is titrated to neutrality against bromothymol blue. After transfer to the distillation apparatus, two thirds of this wine sample is distilled off into the receiver flask. Subsequently the distillate is filled back up to the original volume again. Now the density is measured with a pycnometer or hydrometer.

Heating mantle for roundbottom flask, 250 ml, 230 V, with saftey switch

49542-93

1

Large-scale display, digital, RS-232 port

Task Distillate a sample of wine to determine the content of ethanol. What you can learn about ▪ Ethanol; Distillation

Main articles Large-scale display, digital, RS-232 port Cobra4 Display-Connect, Set of transmitter and receiver for using the Cobra4 MobileLink with large-scale displays Cobra4 Mobile-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni

07157-93

12623-88 12620-00

1 1

12630-00

1

excellence in science 162

1

Function and Applications Special four-digit large-format display for presenting the measurement data supplied by the new Cobra4 Mobile-Link with Cobra4 Display-Connect, the Cobra3 Com-Unit, the PHYWE hand-held measuring instruments and Sartorius or Scaltec balances equipped with data interfaces. 07157-93


8 Organic Chemistry 8.2 Distillation, Purification

Separation of mixtures of liquids and of solutions by extraction, stirring, centrifugation

P3120100

Separation by liquid-liquid extraction.

Principle

Manual centrifuge for 4 specimens

Different methods to separate liquid mixtures are shown. In the first part a mixtures of immiscible or only poorly miscible liquids is separated. In the next example a substance that is dissolved in a certain solvent is better soluble in another solvent and the separation is achieved via shaking. Relatively stable emulsions can't be separated by liquid-liquid extraction alone, since the emulsified liquids will not unmix with a sufficiently sharp delineation. However, separation can be achieved by centrifugating the emulsion in a first step. In this case, the emulsion is unmixed under the influence of the centrifugal force and it can then be separated by liquid-liquid extraction. Tasks 1. Separation by liquid-liquid extraction. 2. Separation shaking and liquid-liquid extraction. 3. Separation of an emulsion by centrifugation and liquid-liquid extraction.

Function and Applications

What you can learn about

Benefits

▪ Separation procedure; Liquid-liquid extraction ▪ Shaking; Centrifugation; Emulsion

▪ To attach to the work bench ▪ Combined plastic / metal housing ▪ The gearbox is self lubricating and very smooth with sleeves made of plastic ▪ Comes with four centrifuge tubes

Main articles Manual centrifuge f. 4 specimens Retort stand, h = 750 mm Ethyl alcohol, absolute 500 ml Cyclohexane 1000 ml Teclu burner, DIN, natural gas Separatory funnel 250 ml pear-sh.

45052-00 37694-00 30008-50 31223-70 32171-05 36884-00

1 1 1 1 1 1

Manual centrifuge with for 4 specimens.

Equipment and technical data ▪ Speed: 3,000 rpm ▪ Centrifuge tube: contents 15 ml, conical, ungraduated 45052-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 163


8 Organic Chemistry 8.2 Distillation, Purification

P3120200

Quantitative determination of fat / Soxhlet extraction

Schematic setup of the experiment.

Principle

Soxhlet attachment, GL25/12

The discussion of healthy nutrition focuses on the fat content of foodstuffs. For this reason, it is important to know the exact fat content of individual foodstuffs. The experiment shown here presents a method for the quantitative determination of the fat content of foodstuffs by extraction using a Soxhlet apparatus. This small size of this Soxhlet extractor makes it possible to extract small quantities using extremely small amounts of solvent. Task Calculate the fat content of a sausage using soxhlet extraction. What you can learn about ▪ ▪ ▪ ▪

Function and Applications

Soxhlet apparatus Fat extraction Food chemistry Food analysis

Main articles Drying oven UNB200, timer, 32 l Heating mantle for roundbottom flask, 100 ml, 230 V, with safety switch Condenser, Dimroth type GL25/12 Power regulator Micro distil.app., GL18/8, with head Soxhlet attachment, GL25/12 Set of Precision Balance Sartorius CPA 423S and measure software, 230 V

46959-93

1

49541-93 35815-15 32288-93 35818-15 35809-15

1 1 1 1 1

49223-88

1

The sample for extraction is placed in an extraction thimble made of compressed filterpaper, the thimble is slipped into the Soxhlet attachment and the attachment is fitted onto a flask containing an appropriate solvent. A reflux condenser is fitted to the top of the attachment and the solvent is heated so that it evaporates. Solvent vapour ascends up the vapour by-pass tube into the reflux condenser, where it condenses and drops back down into the extraction thimble. Here it dissolves out soluble matter from the sample and collects in and around the thimble until the solvent level here reaches the highest point of the siphon tube. The whole of this solvent is then automatically siphoned back into the flask and the procedure repeats itself. In this way, countless extraction steps can be carried out simply and successively, whereby the components extracted from the sample are concentrated in the flask. 35809-15

excellence in science 164


8 Organic Chemistry 8.2 Distillation, Purification

Chromatographic separation processes: Thin layer chromatography

P3120400

Principle Chromatographic separation processes are very important for analytical chemistry. Their relatively simple technique and the possibility to separate even the smallest portions of mixtures explain the rapid development of these processes. There are numerous variations of this method. As a result, the optimum chromatographic separation method can be found for nearly every separation task. The method that is described here can be used to demonstrate the fundamental principles and possibilities of this method with relatively simple means.

For more details refer to page 52.

Chromatographic separation processes: Gas chromatography (with Cobra4)

P3031760

Principle Chromatographic procedures allow a separation of substance mixtures with the aid of a stationary separation phase and a mobile phase. In gas chromatography the mobile phase is a gas. The mobile phase, to which the mixture to be separated is added, transports the substance mixture through the separation column at a constant flow rate. Interactions occur between the mobile phase and the stationary phase. The establishment of equilibria between the stationary phase and the different substances (distribution equilibria, adsorption-desorption equilibria) results in different migration rates of the individual components.

For more details refer to page 53.

Column chromatography - separation of leaf pigments

P3120300

Principle In this investigation, a uniformly green raw extract of fresh leaves is first separated into different fractions by means of column chromatography. To do so, the extract is added to a column filled with starch and drawn through the column under slightly reduced pressure (to increase the flow rate of the mobile phase) with ligroin as the eluent. A separation occurs in a clearly recognisable, broad, yellow area and in a narrow, green band. This means that the xanthophylls (yellow) are separated from the chlorophylls (green). If the vacuum is reduced during the separation, the separation is much better, but then separation also takes considerably longer.

For more details refer to page 54.

PHYWE Systeme GmbH & Co. KG · www.phywe.com 165


8 Organic Chemistry 8.2 Distillation, Purification

Find further experiments in the following manual:

TESS Chemistry manual Organic Chemistry

Petroleum combustion P1037400 Cracking of petroleum P1037500 Removal of paraffin by extraction P1037600 Removal of paraffin with urea P1037700 Alcoholic fermentation P1037800 Production of methanol "wood spirit" P1037900 The ascending tube test P1038000 Alcotest tubes P1038100

Article no. 01837-02

Distillation P1038200

This documentation contains the following experiments:

The borax test P1038300

The decomposition of organic substances P1035700 The detection of carbon with lime water P1035800 The detection of carbon by oxidation P1035900 The detection of oxygen P1036000 The detection of nitrogen P1036100 The detection of sulphur P1036200

The iodoform test P1038400 The properties of the homologous series P1038500 Polyhydric alcohols P1038600 The oxidation of alkanols P1038700 Complete experiment list see: www.phywe.com 01837-02

The Beilstein test P1036301 Marsh gas P1036400 Preparation of methane P1036500 Homologous series of alkanes P1036600 Reactivity of alkanes P1036700 Preparation of ethene P1036800 Preparation of ethyne P1036900 Naphthalene P1037000 Petroleum deposits P1037100 Cracking of petroleum - P1037500

Fractional distillation P1037200 Properties of petroleum fractions P1037300

excellence in science 166


9 Industrial Chemistry

Industrial Chemistry 9.1 9.2 9.3 9.4 9.5

Gases Salts Disposal, Environment Protection Petrochemistry Metallurgy

168 172 174 176 180

PHYWE Systeme GmbH & Co. KG · www.phywe.com 167


9 Industrial Chemistry 9.1 Gases

P3110100

Obtaining nitrogen oxides by burning air

Chemical process for the production of nitric acid.

Principle

Power supply, universal

In an electric arc nitrogen and oxygen are caused to react with each other. In a first step, this leads to the generation of colourless nitrogen monoxide that continues to react with oxygen, thus forming the red-brown nitrogen dioxide. When the gas reacts with water in the presence of even more oxygen, the result is nitric acid that causes the litmus solution to turn red. Tasks 1. Demonstrate the reaction of nitrogen and oxygen using high voltage. 2. Investigate the reaction of nitrogen dioxide with water. Function and Applications

What you can learn about ▪ ▪ ▪ ▪ ▪

Versatile heavy duty power supply which can also be used as a constant current supply in schools, laboratories or workshops.

Nitrogen oxides Air Nitrogen monoxide Nitrogen dioxide Nitric acid

Equipment and technical data

Main articles Power supply, universal Coil, 10000 turns Clamping device Iron core, U-shaped, laminated Coil, 150 turns, short Bar electrodes, HV, insul.,1 pair Iron core, short, laminated

13500-93 06519-01 06506-00 06501-00 06520-01 45253-00 06500-00

1 1 1 1 1 1 1

▪ Direct current source: Stabilised, regulated output direct voltage, continuously adjustable from 0...18 V ▪ Adjustable current limit between 0...5 A ▪ LED display for constant current operationn ▪ Permantely short-circuit proof & protected against exterior voltages ▪ Alternative voltage output: ▪ Multitap transformer 2...15 V, outputs galvanically separated from mains grid ▪ Full load capacity (5 A), even if direct current is supplied simultaneously 13500-93

excellence in science 168


9 Industrial Chemistry 9.1 Gases

Ammonia preparation from the elements (Haber-Bosch process)

P3110200

Schematical setup of the experiment.

Principle The Haber-Bosch process was the first large-scale technical method for producing nitrogen compounds based on the nitrogen in the air. The formation of ammonia benefits from a falling temperature and rising pressure since it is an exothermic reaction that is accompanied by a decrease in volume. At room temperature, however, the reaction rate would be so small that it could not be measured. In addition, current catalysts are only effective at higher temperatures (approximately 400-500 °C). If these temperatures are used at normal pressure, the ammonia yield is approximately 0.1% by volume. Technical processes, in which the pressure is increased in a continuous process, yield approximately 11% (establishment of equilibrium at 200 bar: 17.6% of ammonia). The setup that is used here can be used to demonstrate the HaberBosch process in a simplified manner. The optimum conditions that are necessary for the process cannot be realised with the means that are available at schools or it would be extremely difficult to realise them. Task Demonstrate the principle of the Haber-Bosch process. What you can learn about Ammonia preparation from the elements (Haber-Bosch process)

Main articles Steel cylinder hydrogen, 2 l, filled Steel cylinder nitrogen, 2 l, filled Bead catalyst, Pt-Pd-Al-oxide 10 g Reducing valve for nitrogen Reducing valve for hydrogen

41775-00 41777-00 31763-03 33483-00 33484-00

1 1 1 1 1

Carl Bosch (left) and Friedrich Bergius (right) 1931, Nobel Prize in Chemistry

PHYWE Systeme GmbH & Co. KG · www.phywe.com 169


9 Industrial Chemistry 9.1 Gases

P3110300

Combustion of ammonia to produce nitrogen dioxide - Ostwald process

Combustion process of gas/air mixtures.

Principle In the presence of a suitable catalyst and while giving off heat, ammonia-air mixtures burn and form nitrogen monoxide and water. Nitrogen monoxide reacts immediately with the excess oxygen, thereby forming nitrogen dioxide. At higher temperatures, nitrogen monoxide is decomposed into nitrogen and oxygen. This is why the contact with the catalyst must be very brief. In the presence of water and oxygen, nitrogen dioxide forms nitric acid. On a large industrial scale, the combustion of ammonia with atmospheric oxygen is performed under contact with platinum (Ostwald process). The resulting nitric acid is used for the production of fertilisers and numerous other chemical products. Task Burn an ammonia-air mixture in the presence of a catalyst (platinum-palladium-aluminium-oxide beads) and prove the resulting nitrogen oxide. What you can learn about ▪ Ostwald process; Ammonia; Nitrogen dioxide ▪ Nitrogen monoxide; Nitric acid

Main articles Bead catalyst,Pt-Pd-Al-oxide 10 g Quartz glass wool 10 g Teclu burner, DIN, natural gas Glycerol 250 ml Test tube GL25/8, with hose connec. Water jet pump, plastic

31763-03 31773-03 32171-05 30084-25 36330-15 02728-00

excellence in science 170

1 1 1 1 2 1


9 Industrial Chemistry 9.1 Gases

Sulphur trioxide - the sulphuric acid contact process

P3110400

Formation of sulfuric acid during the experiment.

Principle

Funnel for gas generator, 50 ml, GL18

The contact process is currently used in the chemical industry to produce sulphuric acid in the high concentrations needed for industrial processes. In this model experiment, platinumpalladium-aluminium-oxide beads are employed as a catalyst for the reaction. Tasks 1. Oxidise sulphur dioxide to sulphur trioxide. 2. Use the sulphur trioxide to produce sulphuric acid. What you can learn about ▪ ▪ ▪ ▪ ▪

Sulphur trioxide Sulphuric acid Contact process Oxidation Redox reaction

Main articles Steel cylinder oxygen, 2 l, filled Bead catalyst, Pt-Pd-Al-oxide 10 g Reducing valve for oxygen Funnel for gas generator, 50 ml, GL18 Table stand for 2 l steel cylinders Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

41778-00 31763-03 33482-00 35854-15 41774-00

1 1 1 1 1

49224-88

1

Function and Applications Funnel for gas generator Equipment and technical data: ▪ ▪ ▪ ▪

Lower connecting pipe diameter: 12 mm Outer Diameter Gasolive: 8 mm Overall height: approx 270 mm Contents: 50 ml

35854-15

PHYWE Systeme GmbH & Co. KG · www.phywe.com 171


9 Industrial Chemistry 9.2 Salts

P3110700

Salts of sulphuric acid - sulphates

Schematic construction of the experiment.

Principle Natural gypsum has the formula CaS04•2H20. When it is heated above 130 °C, part of the crystal water is released. The result is a so-called hemihydrate CaS04•1/2H20. Following the absorption of water, the hemihydrate is once again converted into a dihydrate. During this process, needle-shaped crystals are formed. This is why barium sulphate precipitates when barium ions are added to sulphate ions, even if the concentrate of sulphate ions is as low as it is in the present case. This reaction is generally used for the detection of sulphate ions. Tasks 1. Investigate the properties of gypsum. 2. Detect sulphate ions in solution using barium-solution. What you can learn about ▪ ▪ ▪ ▪

Sulphate Gypsum Sulphuric acid Gypsum calcination

Main articles Glass tube f.calcin. of gypsum Teclu burner, DIN, natural gas Gypsum, crude pieces, 250 g Hydrochloric acid 37 %, 1000 ml Barium chloride 250 g Calcium sulphate precipit. 100 g

45145-00 32171-05 48273-25 30214-70 30033-25 31182-10

excellence in science 172

1 1 1 1 1 1


9 Industrial Chemistry 9.2 Salts

Molten-salt electrolysis

P1310500

Oxidation/reduction process during the experiment.

Principle

Crystal-lattice model sodium chloride

The electrolysis of molten sodium chloride to obtain chlorine and sodium, which can be further processed to produce sodium hydroxide, is an important industrial-scale process. The experiment depicted here can be used for a simple demonstration of the important steps in this process. Due to the high melting point of sodium chloride, however, lower-melting lead chloride is used as the raw material in the model experiment. Task Demonstration the electrolysis of molten sodium chloride to obtain chlorine and sodium. What you can learn about ▪ ▪ ▪ ▪

Electrolysis Melt Chlorine Starch-iodine solution Function and Applications

Main articles Multimeter ADM2, demo., analoque Power supply, universal Frame for complete experiments Shelf with hanging device Wash tube with fritted disc Lead-II chloride 500 g Apparatus carrier w. fix. magnet

13820-00 13500-93 45500-00 45505-00 36699-00 31117-50 45525-00

1 1 2 1 1 1 1

High quality crystal-lattice model of sodium chloride consisting of coloured wooden balls and metallic links; the model will be delivered completely fixed. Equipment and technical data ▪ Scale to real crystals: 1 : 250 million ▪ Diameter of the balls: approx. 20 mm 40014-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 173


9 Industrial Chemistry 9.3 Disposal, Environment Protection

P1310000

Model experiment on the desulphurisation of flue gas

Reaction of limestone with sulphur dioxide to gypsum.

Principle

Panel for complete experimental setups

German coal contains an average of one tonne of sulphur per 100 tons of coal. During combustion, this generates in about two tonnes of sulphur dioxide. Thus, a large 700 megawatt power plant which burns about 200 tons of coal per hour produces about 100 tons of sulphur dioxide per day. These days of course, such a large quantity of a pollutant can no longer be simply released into the air, therefore these flue gases have to be desulphurised. This model experiment provides a simple demonstration of the chemical processes of flue gas desulphurisation as it is carried out in power plants today. The clear, compact setup and the simplifications undertaken relative to industrial scale desulphurisation make it easy to understand the process. Task Clean flue gas using limestone and describe the underlying chemical process. What you can learn about

Function and Applications

▪ Sulphur; Limestone; Gypsum ▪ Desulphurisation; Flue gas

Panel with regular punching to receive the hooks of the holder horizontal or vertical positioning in the frame, one panel is neccessary for each experiment Equipment and technical data:

Main articles Frame for complete experiments Secure bottle, 500 ml, 2 x Gl 18/8, 1 x 25/12 Apparatus carrier with fix. magnet Panel for complete experimental setups Combustion tube 200 mm, quartz, IGJ19 Spring manometer, 0...-1000 mbar Quartz glass wool 10 g

45500-00 34170-01 45525-00 45510-00 33947-00 34170-02 31773-03

excellence in science 174

1 1 1 1 1 1 1

▪ Material: sheet steel, powder painted with good mechanical and chemical resistance ▪ Dimensions: 65 x 48.8 x 2.5 cm 45510-00


9 Industrial Chemistry 9.3 Disposal, Environment Protection

Electrostatic flue gas cleaning

P1309200

Smoking chimneys.

Principle

High voltage supply unit, 0-10 kV

Smoke consists of particles of solid substances suspended in gas. Fog is made up of suspended droplets. In cigarette smoke, as in many industrial processes, smoke and fog are frequently present together. The removal of particles contained in gases - predominately waste gases - is increasingly gaining in importance, both in everyday life and industrially, because frequently the particles and the substances absorbed on them are toxic. Well known examples are adsorbed polycyclic aromatics on soot particles in diesel exhaust, and dioxins, heavy metals and radioactive elements in waste gases from power stations and waste incinerators. The deposited filter dusts are highly toxic, and must be treated as hazardous waste. The experimental set-up used here also enables constituents of cigarette smoke to be semi-quantitatively deposited even in quite large amounts, so that they can be extracted with light pertrol and be examined.

For electrostatic experiments and for operation of spectral and gas discharge tubes.

Tasks Clean cigarette smoke using high voltage.

Equipment and technical data

What you can learn about ▪ Smoke; Electric filter; Electrostatic filter; Exhaust gas filter

Main articles High voltage supply unit, 0-10 kV Frame for complete experiments Gas syringe, 100 ml, with 3-way cock Insert with joining tube Apparatus carrier w. fix. magnet Panel for complete experimental setups

Function and Applications

13670-93 45500-00 02617-00 02615-04 45525-00 45510-00

1 1 1 1 1 1

▪ It supplies 3 continuously variable DC voltages isolated from earth and ground. ▪ Two of the voltages are connected in series 0-5 kV DC = total of 0 -10 kV DC. ▪ Selectable positive and negative polarity. 3-figure LED display. ▪ Outputs short-circuit proof. Special safety sockets. ▪ Modern plastic housing, impact resistant, easy to service, light stackable with retractable carrying handle and stand. 13670-93

PHYWE Systeme GmbH & Co. KG · www.phywe.com 175


9 Industrial Chemistry 9.4 Petrochemistry

P3031640

Fractional distillation with the bubble tray column (with Cobra3)

Temperature-time curve for a fractional distillation.

Principle In countercurrent distillation (rectification) using a column, the rising vapour can enter into interactions with the condensate. In this manner, a fractional distillation, i.e. a distillation in several steps for the separation of substances with similar boiling points, can be performed in a single apparatus. If bubble tray columns are used condensate can be removed from the individual bubble trays. Tasks 1. Investigate the mode of operation of a fractionating tower on a two-stage bubble tray column. Distil a mixture of three n-alcanes first with total reflux and then without any reflux. 2. Subsequently, examine and compare the initial mixture, the sump product, the head products and the condensates of both trays gas chromatographically. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Bubble tray column Rectification Continuous and discontinuous distillation Vapour pressure Vaporisation Condensation Raoult's law Gas chromatography

Main articles Cobra3 Chem-Unit, USB Immersion thermostat Alpha A, 230 V Control unit gas chromatograph Bubble tray column, model, with 2 trays

12153-50 08493-93 36670-99 35914-15

excellence in science 176

1 1 1 1

Steel cylinder helium, 2 l, filled Glass jacket Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

41776-00 02615-00

1 1

49224-88

1

Cobra4 Experiment - available 2013 Fractional distillation with the bubble tray column (with Cobra4) P3031660


9 Industrial Chemistry 9.4 Petrochemistry

Rectification - the number of theoretical trays in a distillation column

P3031501

Equilibrium diagram.

Principle

Set rectification plant, 230 V

The separation power of a rectification (fractionating) column can be determined using an appropriate binary mixture whose equilibrium composition is measured in the distillation flask and in the domed glass head of the distillation apparatus. The number of theoretical trays can be numerically or graphically obtained from the measured values. Tasks 1. Prepare 10 mixtures of methyl cyclohexane and n-heptane with substance ratios (mole fractions) from 0 to 1 and with step width of approximately 0.1. To record a calibration curve, determine the refractive indices of the mixtures and plot them against the mole fractions. 2. Distill a mixture of methyl cyclohexane and n-heptane in a rectification column with total reflux until an equilibrium has been established. Determine the composition of the condensate and the number of theoretical trays in the column for a throughput of 500 and 1000 ml/h. What you can learn about

Distillation plant with a height of 235 cm to the demonstration and processing the principles of countercurrent-distillation (phase equilibrium of muticomponent systems) or to the preparative separation of mixtures difficult to separate Benefits ▪ Complete insight into all running processes, because all components have an evacuated, but not silvered isolating-coat ▪ High separation efficiency through 2 large packed columns ( h = 400 mm) ▪ Simple withdrawal of samples through 2 column intermediate pieces ▪ Secure, because the high-efficiency condensor of the column head also condense high-volatile liquids ▪ Simple adjustment of thereflux ratio's through onehand-controlled column head Equipment and technical Data

▪ Bubble tray column; Rectification; Raoult's law ▪ Henry's / Dalton's law; Boiling-point diagram; Reflux ratio

35918-88

1

49224-88 35912-00

1 1

▪ It will be delivered complete with tripod material and all necessary small hardware items. ▪ 6 l four-neck flask; Electrical heating hood ▪ Power regulator; 2 packed columns ▪ Packing bodys (wire mesh rings); 2 column intermediate pieces; Column head; Separate product condensor ▪ Rack system for the set-up of the plant ▪ Small hardware items; CD with literature

35918-50

1

35918-88

Main articles Set rectification plant, 230 V Set of Precision Balance Sartorius CPA 623S and measure software, 230 V Abbe refractometer Data acquisitation set for set rectification plant, 230 V

Function and Applications

PHYWE Systeme GmbH & Co. KG · www.phywe.com 177


9 Industrial Chemistry 9.4 Petrochemistry

P3110800

Cracking of hydrocarbons

Schematic setup of the experiment.

Principle Under the influence of energy, e.g. heat, light, and electric discharge, all chemical compounds can be broken down into smaller fractions. The reaction can continue up to the elements themselves. In general, low-volatile crude oil components are disintegrated as of approximately 400 °C. The presence of a catalyst lowers the activation energy of this cracking reaction so that the decomposition products are formed already at lower temperatures. Saturated carbohydrates are then transformed into smaller saturated and unsaturated molecules. Cycloalkanes are dehydrated to aromatic compounds, straight-chain molecules to branched-chain molecules, and branched-chain molecules to cyclic molecules.

Molecular model construction kit, organic chemistry

Task Investigate the cracking of hydrocarbons using a model experiment.

Function and Applications With these big elements (atoms) for molecular models structures of chemical compounds can be presented especially vividly also to a greater number of observers

What you can learn about ▪ Cracking ▪ Hydrocarbons ▪ Catalyst

Benefits

Main articles Gas syringe, 100 ml, with 3-way cock Bead catalyst, 500 g Vacuum adaptor, straight, GL25/12 Gas-syringe holder with stop Sea sand, purified 1000 g Bromine 100 ml

02617-00 31761-50 35806-15 02058-00 30220-67 30046-10

1 1 1 1 1 1

▪ Structural elements of shockproof plastic ▪ Diameter of the elements: 38 mm (ostentatious) ▪ Chemical elements characterised by internationally usual colours ▪ Angularity of the connections by precisely rivetted push-buttons according to the valences of the elements ▪ Transparent connectors: straight for single bonds and curved for double and triple bonds 39821-88

excellence in science 178


9 Industrial Chemistry 9.4 Petrochemistry

Determination of the heating value of fuel oil and of the calorific value of olive oil

P3021701

Equation to calculate the calorific value (of fuels) and the gross calorific value (of foodstuffs).

Principle The heat of reaction generated during the complete combustion of 1000 g of solid or liquid fuel is known as the calorific value H. In the case of complete combustion of nutritional fats, the gross calorific value can also be determined. In order to ensure complete combustion, the reaction takes place under oxygen. The heat generated during the combustion of a specific amount of fuel is absorbed by a glass jacket calorimeter of known heat capacity. The calorific value of the test substance can be calculated from the temperature increase in the calorimeter. Task Determine the calorific value of heating oil and the gross calorific value of olive oil. What you can learn about ▪ ▪ ▪ ▪

Heat of reaction Heat of combustion Enthalpy of combustion First law of thermodynamics

Main articles Glass jacket Steel cylinder oxygen, 2 l, filled Calorimeter insert for glass jacket Reducing valve for oxygen Table stand for 2 l steel cylinders Combustion lance for gases Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

02615-00 41778-00 02615-01 33482-00 41774-00 02613-00

1 1 1 1 1 1

49224-88

1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 179


9 Industrial Chemistry 9.5 Metallurgy

P5510100

Metallographic sample preparation - grinding and polishing

Surface condition of brass sample after step 1 (MD-Primo 220; Lubricant: water; Time: 2 min; Speed: 300 rpm), Magnification: 100x.

Principle Metallography is the art of preparing metallic samples by grinding, polishing and eventual etching for subsequent microscopic examination. Grinding and polishing is to prepare the specimen surface so as to enable the microstructure to be revealed by a suitable etching procedure.

Grinding and polishing machine, 230 V 200/250 mm, 50-600 rpm, variable

Tasks 1. Check the six metal specimens by means of the magnifier for any coarse defects. 2. Grind and polish the samples according to the general rules and the detailed instructions given, considering the hardness and ductility data and the basic processing guidelines specified. 3. Evaluate the influence of the individual process parameters on the surface quality obtained in the intermediate steps and after the final polishing. 4. Try to optimise the grinding and polishing procedures. What you can learn about

Grinding and polishing machine to prepare metallographic samples.

▪ Grinding; Polishing ▪ Metallographic preparation; Ductility

Benefits

Main articles

Variable grinding speed to prepare hard and soft samples.

Grinding and polishing machine, 230 V 200/ 250 mm, 50-600 rpm, variable Ultrasonic cleaning bath, RK100H Diamantstick 6 µm, 25 g Grinding and polishing wheel Al, 200 mm Polishing cloth Ø 200 mm, METAPO-P, 10 pcs. for 10-6 micron diamonds Polishing cloth Ø 200 mm, METAPO-B, 10 pcs. for 3-1 micron diamonds Polishing cloth Ø 200 mm, METAPO-V, 10 pcs. for 1-0,1 micron diamonds

Equipment and technical data 70000-93 46423-93 70050-04 70000-11

1 1 1 1

70002-03

1

▪ ▪ ▪ ▪ ▪ ▪

70003-03

1

70000-93

70004-03

1

excellence in science 180

Function and application

Diameter grinding platen: 200 and 250 mm, respectively Speed: 50-600 rpm Connected power: 60 W Power supply : 230 VAC Dimensions (L x B x H): 380 x 690 x 340 mm Weight: 30 kg


9 Industrial Chemistry 9.5 Metallurgy

Metallographic sample preparation - chemical etching

P5510200

Copper, etched in sol. 5, grain contrast/precip. etching, magnification approx. 100x.

Principle Chemical etching is the most common method for contrasting polished metal surfaces to reveal structural details of pure metals and alloys. The precondition for a good result in etching is a carefully polished and clean surface. The experiment describes the basic procedure, gives some recipes and presents a few pictures of several metal structures and phases. Tasks 1. Check the six metal specimens polished by means of the microscope to see if any macroscopic or microscopic structural features can be noticed. 2. Prepare the etching solutions and etch the specimens according to the instructions. 3. Examine the specimen surfaces as to whether the structural details have been satisfactorily revealed. What you can learn about ▪ Etching; Reveal crystallographic structure ▪ Micrography; Metallographic phases; Metal microscopy

Main articles Microscope with incident and transmitted illumination set with USB CAM, 230 V for metallographic appl. Press for polished section Compact Balance, OHAUS TA 501, 500 g / 0.1 g, 230 V Sample set metallurgy containing 8 metall samples Labels GHS, blank, chemistry, 20 pcs. Isopropyl alcohol, 1000 ml Pasteur pipettes, 3 ml, PE, 500 pcs.

62244-88 62244-15

1 1

49243-93

1

70001-01 38687-01 30092-70 36616-00

3 1 1 1

PHYWE Systeme GmbH & Co. KG · www.phywe.com 181


9 Industrial Chemistry 9.5 Metallurgy

P3110500

Preparation of iron from oxidic ores (blast furnace process)

Iron oxide is reduced to iron by hydrogen, which reacts with hydrochloric acid with evolution of hydrogen.

Principle This is a model experiment to show the industrial blast furnace process to produce iron from iron(III) oxide. During the experiment a furnace gas flame that is approximately 10 to 20 cm high can be ignited at the stack outlet. Cavities form in the burning carbon layer. These cavities collapse over time. Apart from ash and carbon residues, metallic lumps can also be found in the frame after the end of the experiment. Samples of these lumps lead to the formation of hydrogen when they are treated with hydrochloric acid. Tasks 1. Investigate the reduction fo iron(III) oxide to iron(II) oxide. 2. Show the blast furnace process in a model experiment. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Iron Blast furnace process Slug Production of iron Reduction Oxidation

Main articles Steel cylinder Hydrogen, 2 l, full Support, with closed-circuit pipeline Hot air blower with adaptor Reducing valve for hydrogen Table stand for 2 l steel cylinders Set of Precision Balance Sartorius CPA 623S and measure software, 230 V

41775-00 36688-01 36688-93 33484-00 41774-00

1 1 1 1 1

49224-88

1

excellence in science 182

Related Experiment Redox reactions between metals and metal oxides (thermite process) P3110600


10 Biochemistry and Biotechnology

Biochemistry and Biotechnology 10.1 10.2 10.3

Biochemistry Biotechnology Literature

184 188 193

PHYWE Systeme GmbH & Co. KG · www.phywe.com 183


10 Biochemistry and Biotechnology 10.1 Biochemistry

P4120160

Determination of the isoelectric point of an amino acid (glycine) (with Cobra4)

Titration curve for hydrochloric acid glycine solution against 1 mol/l NaOH.

Principle Amino acid molecules carry both acid and amino groups. They can therefore form both acidic anions and basic cations. The pH at which these two types of iones are both present in the same concentration is called the isoelectric point. Task This isoelectric point is to be determined by recording the titration curve for the amino acid glycine. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Isoelectric point Acidic anions Basic cations Zwitterions Equivalence (inflection) points pKs value Titration Motor piston burette

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Cobra4 Sensor-Unit Drop Counter Software Cobra4 - multi-user licence Immersion probe NiCr-Ni, teflon, 300 °C Precision Balance, Sartorius TE 212, 210 g / 0,01 g, 230V

12600-00 12601-00

1 2

12630-00 12636-00 14550-61 13615-05

1 1 1 1

48833-93

1

excellence in science 184


10 Biochemistry and Biotechnology 10.1 Biochemistry

Determination of the Michaelis constant (with Cobra4)

P4120360

Conductivity-time-diagram of the urea hydrolysis by urease.

Principle The enzymatic hydrolysis of urea in aqueous solution liberates carbon dixide and ammonia. The ions of these compounds increase the conductivity of the solution. Conductivity measurements can so be made to determine the rate of hydrolysis of urea by the enzyme urease at various substrate concentrations.

Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000)

Task The Michaelis constant can then be calculated from these values. What you can learn about ▪ ▪ ▪ ▪ ▪ ▪

Michaelis constant Enzymatic hydrolysis of urea Conductivity measurement Bodenstein principle Enzyme-substrate complex Lineweaver-Burk plot

Function and Applications

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Software Cobra4 - multi-user licence Conductivity temperature probe Pt1000 Urease soln.in 50% glycerol, 10ml Precision Balance, Sartorius TE 212, 210 g / 0,01 g, 230 V

12600-00 12601-00

1 1

12632-00 14550-61 13701-01 31924-03

1 1 1 1

48833-93

1

The Cobra4 Sensor Unit, Conductivity/Temperature (Pt1000), is a microcontroller-based measuring recorder with a 5-pin diode socket for connecting conductance measuring sensors with a cell constant of K = 1.00/cm or Pt1000 thermocouples. Benefits ▪ Measure conductivity or temperature - multipurpose-sensor ▪ The Cobra4 sensor may be connected directly to the Cobra4 Wireless-Link, the Cobra4 Mobile-Link, the Cobra4 USB-Link or the Cobra4 Junior-Link using a secure and reliable snap-in connection. 12632-00

PHYWE Systeme GmbH & Co. KG · www.phywe.com 185


10 Biochemistry and Biotechnology 10.1 Biochemistry

P4120460

Substrate inhibition of enzymes (with Cobra4)

The dependence of the rate of enzymolysis on the concentration.

Principle

Software Cobra4 - multi-user licence

The enzymatic hydrolysis of urea in aqueous solution liberates carbon dioxide and ammonia. The ions of these compounds increase the conductivity of the solution. Tasks Conductivity measurements enable the rate of hydrolysis of urea by the enzyme urease to be determined at various substrate concentrations. Inhibition of the enzyme by the substrate occures at excessive substrate concentrations. What you can learn about ▪ ▪ ▪ ▪

Substrate inhibition Enzymolysis of urea Conductivity-time plot Reaction velocity of enzymatic hydrolysis

Main articles Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) Conductivity temperature probe Pt1000 Software Cobra4 - multi-user licence Magnetic stirrer Mini / MST Urease soln.in 50% glycerol,10ml

12600-00 12601-00

1 1

12632-00 13701-01 14550-61 47334-93 31924-03

1 1 1 1 1

Function and Applications The "measure Cobra4" measuring software leaves nothing to be desired. As soon as a Cobra4 sensor is connected to a PC, irrespective of whether by Cobra4 Wireless or Cobra4 USB Link, the "measureCobra4" software opens completely automatically and shows the connected sensors, the required measuring windows and the current measuring data. Measurement recording is then started with a single CLICK. This all takes under 40 seconds! 14550-61

excellence in science 186


10 Biochemistry and Biotechnology 10.1 Biochemistry

Enzyme inhibition (poisoning of enzymes) (with Cobra4)

P4120560

Principle The enzymatic hydrolysis of urea in aqueous solutions liberates carbon dioxide and ammonia. The ions of these compounds increase the conducitivity of the solution. Task Conductivity measurements enable the rate of hydrolysis of urea by the enzyme urease to be determined. The addition of an appropriate inhibitor poisons the enzyme, so that it no longer converts substrate.

For more details refer to page 100.

The enzymatic activity of catalase (with Cobra4)

P4120660 Principle Catalase is an enzyme that - in humans - is found predominantly in the liver and erythrocytes. It decomposes hydrogen peroxide, which is a toxic byproduct of cellular respiration, into water and oxygen. Tasks 1. To examine the enzymatic decomposition of hydrogen peroxide, a cell respiratory poison, in the liver. 2. To investigate the influence of the temperature and pH on the metabolic activity.

For more details refer to www.phywe.com

PHYWE Systeme GmbH & Co. KG · www.phywe.com 187


10 Biochemistry and Biotechnology 10.2 Biotechnology

P1313600

Fermentation of molasse to ethanol with yeast

Destillation of the fermented mash.

Principle

Bubble bioreactor

As a result of the need to save energy and the increased consciousness of environmental problems, biotechnological production methods are on the advance. Fermenters are used for the biotechnological production of enzymes and other products using bacteria, yeast and cell cultures. For educational purposes a bubble bioreactor used in this experiment is a more convenient and economical alternative to commercial fermenters. To demonstrate how fermenters work, in this experiment molasse which is a waste product of sugar production is fermented in the so-called batch process. Tasks 1. Molasse is to be fermented to ethanol. 2. Determine the yield of your process. What you can learn about ▪ ▪ ▪ ▪

Fermentation Ethanol Bioreactor Yeast

Function and Applications

Main articles Immersion thermostat Alpha A, 230 V Heating mantle for roundbottom flask, 250 ml, 230 V, with saftey switch Bubble bioreactor Frame for complete experiments Power regulator Bath for thermostat, makrolon Liebig Condenser, with head, GL18/8

08493-93

1

49542-93 65999-00 45500-00 32288-93 08487-02 35795-15

1 1 1 1 1 1

excellence in science 188

This consists of a long glass tube jacket for temperature control and a glass insert tube which reaches from tip to tip. The jacket has two hose nipples for entry and exit of the temperature controlling liquid. The GL 32/18 opening in the bottom of the reactor is for aeration, the two openings at the top (GL25/8 and GL 18/8) are for the addition of the culture medium or for removal offinal products. Equipment and technical data ▪ Length: 400 mm; Diameter: 50 mm 65999-00


10 Biochemistry and Biotechnology 10.2 Biotechnology

Microbial synthesis of ethanol by Zymomonas mobilis subsp. mobilis (with Cobra4)

P1313762

Enzymatic processes (Entner-Doudoroff pathway).

Principle

What you can learn about

The properties of the microorganism Zymomonas mobilis have been used in the production of alcohol for centuries. Nevertheless, the bacterium in palm wine and pulque, the fermented juice of the agave plant, was not identified and recognised as being responsible for their alcoholic fermentation until the twentieth century. Zymomonas was found to synthesise ethanol much more effectively than yeast does.

▪ ▪ ▪ ▪ ▪ ▪

In this experiment, Zymomonas mobilis is grown in a bioreactor. The medium is blended by means of a magnetic stirrer and its temperature is controlled by means of a heating coil and a water bath with thermostats. The discharge of used medium and the supply of fresh medium can be dispensed with. This is a so-called 'static culture' (batch culture). The cell density can first be determined photometrically in the samples taken and the cell count can be determined in the counting chamber, and those data can be used to generate a growth curve. Chemical and enzymatic tests show the consumption of glucose and the production of ethanol.

Turbidimetry Zymomonas mobilis Cell count Haemocytometer Yeast Fermentation

Main articles Spectrophotometer S800, 330...800 nm Autoclave with insert Drying oven UNB200, timer,32 l Centrifuge w. angle rotor 8x15 ml Immersion thermostat Alpha A, 230 V Set of Precision Balance Sartorius TE 412 and measure software balances,230 V Bioreactor, 1 l, 7 connections

35600-99 04431-93 46959-93 65973-93 08493-93

1 1 1 1 1

48835-88 66000-00

1 1

The experiment is easy to perform. It does not take long to prepare. The evaluation of the test results is very conclusive and clearly illustrates the methods of biotechnology. Tasks 1. Prepare the agar plates that are to be used for strain maintenance of the bacteria to be used. 2. Determine the course of the fermentation of Zymomonas by a turbidimetric procedure. 3. Determine the cell count microscopically in a haemocytometer.

PHYWE Systeme GmbH & Co. KG · www.phywe.com 189


10 Biochemistry and Biotechnology 10.2 Biotechnology

P1313862

Production of amino acids by fermentation of Corynebacterium glutamicum (with Cobra4)

Preparation of the strain maintenance plate.

Prinicple

Autoclave with insert

A bacteria culture of Corynebacterium glutamicum is used in a bioreactor at a constant temperature of 30 °C to produce amino acids. Under these conditions the fermentation of Corynebacterium glutamicum takes place in a so-called batch process for 7 to 10 days. Tasks 1. Start the fermentation of Corynebacterium glutamicum. 2. Determine the yield of the process. 3. Determine the composition of the mixture of amino acids using TLC. What you can learn about ▪ Fermentation ▪ Thin layer chromatography ▪ Amino acids

Main articles Autoclave with insert Drying oven UNB200, timer, 32 l Immersion thermostat Alpha A, 230 V Bioreactor, 1 l, 7 connections Cobra4 Mobile-Link set, incl. rechargeable batteries, SD memory card, USB cable and software "measure" Frame for complete experiments Set of Precision Balance Sartorius CPA 423S and measure software, 230 V

04431-93 46959-93 08493-93 66000-00

1 1 1 1

12620-55 45500-00

1 1

49223-88

1

Function and Applications Portable autoclave with insert. Equipment and technical data With precision manometer Thermometer Integrated heating Application range up to 1.4 bar at 125 °C or up to 2.7 bar at 140 °C ▪ Volume: 12 liters; safety valve ▪ Excess pressure safetyvalve; safety lock ▪ ▪ ▪ ▪

04431-93

excellence in science 190


10 Biochemistry and Biotechnology 10.2 Biotechnology

Bacteria and mining - microbial extraction of ore by Thiobacillus ferrooxidians and thiooxidans (with Cobra4)

P1313962

Chemical process during extraction.

Principle Scientists first recognised importance of certain bacteria for the extraction of metals from ore in the 1950s. Nowadays the microbial ore leaching with so-called 'lean ores' represents more than 10% of the total production of copper in the USA alone. The bioreactor shown here can be used to clearly demonstrate to the students this method of extraction (e.g. copper from copper ore) using such bacteria (Thiobacillus ferrooxidans).

Cobra4 Mobile-Link set, incl. rechargeable batteries, SD memory card, USB cable and software "measure"

Main articles Autoclave with insert Drying oven UNB200, timer, 32 l Cobra4 Mobile-Link set, incl. rechargeable batteries, SD memory card, USB cable and software "measure" Cobra4 Sensor-Unit Chemistry, pH and 2 x Temperature NiCr-Ni Bubble bioreactor Frame for complete experiments Set of Precision Balance Sartorius CPA 423S and measure software, 230 V

04431-93 46959-93

1 1

12620-55

1

12630-00 65999-00 45500-00

1 1 1

49223-88

1 Function and Applications The Cobra4 Mobile-Link is a modern, high performance hand measuring device for mobile data recording, to which all Cobra4 Sensor-Units can be connected via secure plug-in/ lockable connection. 12620-55

PHYWE Systeme GmbH & Co. KG · www.phywe.com 191


10 Biochemistry and Biotechnology 10.2 Biotechnology

P1314000

Immobilised cells in the service of biotechnology - microbial synthesis of acetic acid with Acetobacter aceti

The biochemical oxidation of alcohol.

Principle As early as 1864, Louis Pasteur recognised that both alcoholic fermentation and the oxidation of alcohol to acetic acid depend upon the metabolic performance of specific bacteria. Gram-negative, flagellated rods are responsible for the formation of acetic acid. Two large groups are differentiated here, the representatives of one of these are comprised of the genus Acetobacter, and those of the other of the genus Gluconobacter. In nature, these bacteria are to be found on fruit, in floral nectar and leaf nectar, as well as in beer, wine and fruit juices. They are capable of utilising simple sugar as well as simple alcohol as substrate.

Immersion thermostat Alpha A, 230 V Set of Precision Balance Sartorius CPA 423S and measure software, 230 V

08493-93

1

49223-88

1

Drying oven UNB200, timer, 32 l

Tasks 1. Determine the ethanol content by an enzymatic indicator reaction. 2. Determine content of acetic acid by an enzymatic indicator reaction. 3. Produce acetic acid with the "rapid vinegar procedure". What you can learn about ▪ ▪ ▪ ▪

"Rapid vinegar procedure" Acetic acid Immobilised cells Bacterial culture Function and Applications

Main articles Spectrophotometer S800, 330...800 nm Autoclave with insert Drying oven UNB200, timer,32 l Centrifuge w. angle rotor 8x15 ml Peristaltic pump, 220V, 8 to 60 ml/min.

35600-99 04431-93 46959-93 65973-93 35705-93

excellence in science 192

1 1 1 1 1

Drying oven UNB200 for drying, sterilizing, warming and incubating in the temperature range from30 °C to 220 °C. 46959-93


10 Biochemistry and Biotechnology 10.3 Literature

Complete Experiments Chemistry/ Biotechnology

Boiling point elevation P1310200 Gas laws P1310300 The contact process P1310400 Molten-salt electrolysis P1310500 Steam distillation P1311500 PEM fuel cell P1312000 Synthesis of water P1312100 Fermentation of molasse to ethanol with yeast P1313600

Article no. 01855-02 Complete Experiments Chemistry and Biotechnology This documentation contains the following experiments: Model experiment on the fractional distillation of petroleum P1308600 Reaction of aldehydes with ammonia P1308700 Determination of molar masses with the vapour density method P1308800 Distillation - determination of the alcohol content of wine P1308900 Determination of enthalpies of combustion P1309000

Microbial synthesis of ethanol by Zymomonas mobilis subsp. mobilis P1313700 Production of amino acids by fermentation of Corynebacterium glutamicum P1313800 Bacteria and mining - microbial extraction of ore by Thiobacillus ferrooxidians and thiooxidans P1313900 Immobilised cells in the service of biotechnology - microbial synthesis of acetic acid with Acetobacter aceti P1314000 01855-02

Synthesis of ethyl acetate and butyl acetate P1309100 Electrostatic flue gas cleaning P1309200 Column chromatography - separation of leaf pigments P1309300 Determination of the molar masses of metals P1309400 Faraday's laws P1309500 Avogadro's law P1309600 Air analysis (nitrogen in air) P1309700 E.M.F. measurements with a standard hydrogen electrode P1309800 Obtaining vegetable oils by extraction P1309900 Model experiment on the desulphurisation of flue gas P1310000 Chemical fountain P1310100

Microbial synthesis of ethanol by Zymomonas mobilis subsp. mobilis - P1313700

PHYWE Systeme GmbH & Co. KG · www.phywe.com 193


10 Biochemistry and Biotechnology 10.3 Literature

Demo advanced Biology Manual Cobra4 Biochemistry & plant physiology

Article no. 01331-02

Glycolysis - P1351460

Description Experimental descriptions from the fields of biochemistry and plant physiology that pay particular attention to the advantages of data acquisition with the Cobra4 system. In total more than 10 demonstration experiments are described in detail. Topics ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪

Photosynthesis (2 different methods) Transpiration of leaves Glycolysis (2 different methods) The ionic permeability of the cell membrane Determination of the Michaelis constant Enzyme inhibition Substrate inhibition of enzymes The enzymatic activity of catalase

Equipment and technical data Din A4 stapled, in colour Enzyme inhibition - P4120560

56 pages This documentation contains the following experiments: Transpiration of leaves (with Cobra4) P1351260 Photosynthesis (O2 pressure measurement) (with Cobra4) P1351360 Glycolysis (temperature measurement) (with Cobra4) P1351460 The enzymatic activity of catalase (with Cobra4) P1360760 Photosynthesis (bubble-counting-method) (with Cobra4) P1360860 Glycolysis (pressure measurement) (with Cobra4) P1360960 Ionic permeability of the cell membrane (with Cobra4) P1369760 Determination of the Michaelis constant (with Cobra4) P1369860 Complete experiment list see: www.phywe.com 01331-02

excellence in science 194

Photosynthesis (bubble-counting-method) - P1360860


11 About PHYWE

About PHYWE 11.1 11.2 11.3 11.4 11.5

Company profile Nobel Prize Experiments Computer Assisted Measurement Safety Instructions General terms and conditions

196 198 200 204 207

PHYWE Systeme GmbH & Co. KG · www.phywe.com 195


11 About PHYWE 11.1 Company profile

excellence in science 196


11 About PHYWE 11.1 Company profile

PHYWE Systeme GmbH & Co. KG · www.phywe.com 197


11 About PHYWE 11.2 Nobel Prize Experiments

excellence in science 198


11 About PHYWE 11.2 Nobel Prize Experiments

PHYWE Systeme GmbH & Co. KG · www.phywe.com 199


11 About PHYWE 11.3 Computer Assisted Measurement

excellence in science 200


11 About PHYWE 11.3 Computer Assisted Measurement

PHYWE Systeme GmbH & Co. KG · www.phywe.com 201


11 About PHYWE 11.3 Computer Assisted Measurement

excellence in science 202


11 About PHYWE 11.3 Computer Assisted Measurement

PHYWE Systeme GmbH & Co. KG · www.phywe.com 203


11 About PHYWE 11.4 Safety Instructions

excellence in science 204


11 About PHYWE 11.4 Safety Instructions

PHYWE Systeme GmbH & Co. KG · www.phywe.com 205


11 About PHYWE 11.4 Safety Instructions

excellence in science 206


11 About PHYWE 11.5 General terms and conditions

PHYWE Systeme GmbH & Co. KG · www.phywe.com 207


11 About PHYWE 11.5 General terms and conditions

excellence in science 208


12 Indices

Indices 12.1 12.2 12.3

Numerical Index Alphabetical Index www.PHYWE.com

210 212 216

PHYWE Systeme GmbH & Co. KG · www.phywe.com 209


12 Indices 12.1 Numerical Index

Art no. P1025200 P1026800 P1026900 P1135700 P1268360 P1273460 P1282360 P1308962 P1309200 P1309400 P1310000 P1310100 P1310500 P1313600 P1313762 P1313862 P1313962 P1314000 P2140300 P2140400 P2210300 P2310100 P2320201 P2320300 P2320400 P2411100 P2510200 P2510311 P2510315 P2510600 P2510700 P2511006 P2511111 P2511205 P2532000 P2538000 P2538400 P2541301 P2541401 P2541501 P2541601 P2541602 P2542101 P2542201 P2542301 P2542401 P2542501 P2544501 P2544601 P2544701 P2545001 P2545101 P3010301 P3010401 P3010501 P3010601 P3011160 P3011260 P3011360 P3011400 P3020260 P3020411 P3020460 P3020501 P3020611 P3020660 P3020711 P3020760 P3020811 P3020860 P3020911 P3020960 P3021001 P3021101 P3021401 P3021501 P3021601 P3021701 P3021900 P3022000 P3030401 P3030501 P3030601 P3030701 P3030862 P3030960 P3031001 P3031101 P3031251 P3031360 P3031401 P3031501 P3031640 P3031660 P3031760 P3031900

Description Oxidation of metals Reduction of silver oxide Reduction of copper oxide Osmosis - dependence of the osmotic… Voltage of a concentration cell (with Cobra4) Heat of fusion of sodium thiosulphate… Electrochemical series of metals (with… Distillation - determination of the… Electrostatic flue gas cleaning Determination of the molar masses of metals Model experiment on the desulphurisation… Chemical fountain Molten-salt electrolysis Fermentation of molasse to ethanol with yeast Microbial synthesis of ethanol by… Production of amino acids by fermentation… Bacteria and mining - microbial… Immobilised cells in the service of… Viscosity of Newtonian and non-Newtonian… Viscosity measurement with the falling… Dispersion and resolving power of a prism… Thermal expansion in solids and liquids Heat capacity of gases Maxwellian velocity distribution Thermal equation of state and critical point Characteristic curve and efficiency of a… Specific charge of the electron e/m Franck-Hertz experiment with a Hg-tube Franck-Hertz experiment with a Ne-tube Fine structure: One and two electron spectra Balmer series/ determination of… Zeeman effect with a variable magnetic system Stern-Gerlach experiment with a step… Model experiment NMR / ESR Atomic Resolution of the graphite… Basic methods in imaging of micro and… Imaging of biological and medical micro… Examination of the structure of NaCl… X-ray investigation of cubic crystal… X-ray investigation of hexagonal crystal… X-ray investigation of crystal structures… X-ray investigation of crystal structures… Debye-Scherrer diffraction patterns of… Debye-Scherrer diffractions pattern of… Debye-Scherrer diffraction patterns of… Debye-Scherrer diffraction patterns of… Debye-Scherrer diffraction patterns with… Qualitative X-ray fluorescence… Qualitative X-ray fluorescence analysis… Qualitative X-ray fluorescence analysis… Quantitative X-ray fluorescence analysis… Quantitative X-ray fluorescence analysis… Diffusion in gases: The diffusion… Determination of molar mass using the… Determination of the molecular mass of a… Determining the molecular weight of a… Gay-Lussac's law (with Cobra4) Amontons' law (with Cobra4) Boyle's law (with Cobra4) Condensation of gases through an increase… Adiabatic coefficient of gases -… Determination of the enthalpy of… Determination of the enthalpy of… Partial molar volumes Determination of the mixing enthalpy of… Determination of the mixing enthalpy of… Determination of the hydration enthalpy… Determination of the hydration enthalpy… Determination of the enthalpy of… Determination of the enthalpy of… Determination of the melting enthalpy of… Determination of the melting enthalpy of… Boiling point elevation Freezing point depression Determination of the enthalpy of… Determination of the heat of formation of… Determination of the heat of formation… Determination of the heating value of… Determination of molar masses via a… Determination of molar masses via a… Boiling point diagram of a binary mixture Solubility diagram of two partially… Miscibility gap in a ternary system Distribution equilibrium Solubility product (with Cobra4) Dissociation equilibrium (with Cobra4) Complex formation equilibrium / complex… Dissociation constants Steam distillation Melting diagram of a binary mixture (with… Law of integer ratio of volumes according… Rectification - the number of… Fractional distillation with the bubble… Fractional distillation with the bubble… Chromatographic separation processes: Gas… Sublimation and solubility of iodine

excellence in science 210

Page 135 136 136 32 116 120 116 162 175 23, 44 174 26 135, 173 188 189 190 191 192 77 78 132 91 81 75 73 114 128 125 125 126 127 129 130 64 148 150 150 143 144 144 145 145 146 146, 147 146 146 146 58 58 56 57 58 76 19 20 79 70 71 72 122 80 82 82 83 84 84 85 85 25, 85 25 86 86 117 118 87 88 89 90, 179 21 22 119 28 29 18 33 17, 34 16, 137 35 124, 161 121 73 160, 177 124, 160 176 53 123

Art no. P3040801 P3050101 P3050201 P3050301 P3050760 P3050860 P3051101 P3060111 P3060160 P3060260 P3060301 P3060401 P3060560 P3060660 P3060760 P3060862 P3060962 P3061062 P3061101 P3061262 P3061460 P3061562 P3061660 P3061760 P3061811 P3061860 P3062101 P3062201 P3070101 P3070301 P3070401 P3100100 P3100300 P3100400 P3101000 P3101100 P3101300 P3101400 P3101500 P3101600 P3110100 P3110200 P3110300 P3110400 P3110500 P3110600 P3110700 P3110800 P3110900 P3111000 P3120100 P3120200 P3120300 P3120400 P3120500 P3121060 P3121260 P3121360 P3121460 P3121660 P4100760 P4120160 P4120360 P4120460 P4120560 P4120660 P5510100 P5510200 P5942100 P5942200 01196-12 01200-02 01233-02 01331-02 01837-02 01855-02 02611-00 02612-00 02615-00 02615-01 02740-95 04233-00 04403-00 04431-93 06605-00 06748-00 06959-01 07128-00 07157-93 08173-00 08493-93 09058-30 09060-00 09110-88 09140-88 09160-88

Description Adsorption isotherms Saponification rate of tert-butyl chloride Reaction rate and activation energy of… Kinetics of the inversion of saccharose Halogen exchange rate (with Cobra4) Conductometric measurement of the… Dependence of the reaction velocity on… Charge transport in solids (with Cobra3) Charge transport in solids (with Cobra4) Charge transport in liquids (with Cobra4) Ion migration velocity Transference numbers Temperature dependence of conductivity… Conductivity of strong and weak… Conductivity titration (with Cobra4) Determination of the activity coefficient… Nernst equation (with Cobra4) Concentration cells without transport:… Determination of diffusion potentials Temperature dependence of the… Precipitation titration (with Cobra4) pH measurement (with Cobra4) Titration curves and buffering capacity… Potentiometric pH titration (phosphoric… Electrode kinetics: The hydrogen… Electrode kinetics: The hydrogen… Determination of Faraday's constant Electrogravimetric determination of copper Absorption of light (UV-VIS spectroscopy) Excitation of molecules Absorption spectra and pKa values of… Effects of acids on metals Reduction - reducing agents - redox process Reduction of lead oxide Haloalkanes: Grignard reagent Haloalkanes: Wurtz reaction - lithium… Toluene: Bromination in the nucleus Aldehydes - reactions with ammonia Preparation of p-toluenesulfonic acid Cannizzaro reaction and reaction of… Obtaining nitrogen oxides by burning air Ammonia preparation from the elements… Combustion of ammonia to produce nitrogen… Sulphur trioxide - the sulphuric acid… Preparation of iron from oxidic ores… Redox reactions between metals and metal… Salts of sulphuric acid - sulphates Cracking of hydrocarbons The empirical formula of methane, ethane… Avogadro's law Separation of mixtures of liquids and of… Quantitative determination of fat /… Column chromatography - separation of… Chromatographic separation processes:… Electrophilic addition of bromine to… Volumetric redox titration: Cerimetry… Titration of a polyvalent acid with a… Titration of a weak organic acid with… Titration of a weak base (ammonia) with a… Briggs-Rauscher Reaction (with Cobra4) The origin of acid rain (with Cobra4) Determination of the isoelectric point of… Determination of the Michaelis constant… Substrate inhibition of enzymes (with Cobra4) Enzyme inhibition (poisoning of enzymes)… The enzymatic activity of catalase (with… Metallographic sample preparation -… Metallographic sample preparation -… Fundamental principles of Nuclear… Relaxation times in Nuclear Magnetic… Handbook Glass Jacket System Handbook Physics X-Ray Experiments Laboratory Experiments Magnetic Resonace… Demo advanced Biology Manual Cobra4… TESS Chemistry manual Organic Chemistry Complete Experiments Chemistry/Biotechnology Plunger eudiometer Slow eudiometer Glass jacket Calorimeter insert for glass jacket Rotary vane pump, one stage, 115 V/230 V Dilatometer with clock gauge Calorimetric bomb Autoclave with insert Flat chamber for ionic migration PEM electrolyser e/m - Observation chamber Digital multimeter 2010 Large-scale display, digital, RS-232 port Gas liquefier Immersion thermostat Alpha A, 230 V XR 4.0 X-ray energy detector (XRED) Kinetic gas theory apparatus XRE 4.0 X-ray expert set XRS 4.0 X-ray structural analysis upgrade set XRM 4.0 X-ray material analysis upgrade set

Page 92 93 95 96 97 98 94 101 101 102 103 104 105 106 46 107 108 31 32, 109 110 49 111 24, 50 47 112 112 113 51, 115 66 66 66 135 38 39, 136 138 139, 154 155 156 157 158 168 169 170 171 182 37, 134 172 178 41 42 163 164 54 52 159 48 27, 50 27, 50 27, 50 43, 99 30 184 185 186 100 187 180 181 62, 131 63 74 152 63 194 166 193 42 41 88 90 19 91 87 190 103 114 128 115 162 122 83 57 75 56, 57 143, 144 56, 57


12 Indices 12.1 Numerical Index

Art no. 09180-88 09500-99 09600-99 09613-00 09700-99 11207-20 12600-00 12601-00 12602-00 12620-55 12630-00 12632-00 12636-00 12736-00 13300-10 13301-10 13431-88 13433-88 13500-93 13531-93 13601-99 13617-93 13670-93 13701-01 13715-93 13727-99 14550-61 15300-88 15301-88 18220-00 18223-99 32246-93 35010-06 35610-88 35635-02 35655-93 35750-93 35790-15 35809-15 35821-00 35854-15 35900-02 35906-93 35912-00 35918-88 36820-00 36821-00 39818-88 39821-88 39837-00 40014-00 40018-00 40022-00 40461-00 40466-00 43003-88 43020-00 43030-88 44518-00 45052-00 45510-00 46959-93 47310-02 47334-93 49224-88 65999-00 70000-93

Description XRCT 4.0 X-ray Computed Tomography… Compact MRT Compact-Scanning Tunneling Microscope (STM) Set samples nanomorphology, for Compact… Compact-Atomic Force Microscope (AFM) Light barrier, compact Cobra4 Wireless Manager Cobra4 Wireless-Link Cobra4 Remote-Link Cobra4 Mobile-Link set, incl.… Cobra4 Sensor-Unit Chemistry, pH and 2 x… Cobra4 Sensor-Unit Conductivity+,… Cobra4 Sensor-Unit Drop Counter Cobra4 hand-held pressure and temperature… TESS advanced General Chemistry,… TESS advanced Inorganic Chemistry,… TESS advanced General Chemistry,… TESS advanced Inorganic Chemistry,… Power supply, universal Variable transformer, 25 VAC/ 20 VDC, 12 A Universal Counter Temperature meter digital, 4-2 High voltage supply unit, 0-10 kV Conductivity temperature probe Pt1000 Work and power meter Multi channel analyser Software Cobra4 - multi-user licence TESS advanced Chemistry set General… TESS advanced Chemistry set Inorganic… Falling ball viscometer Rotary viscometer, 15 - 2,000,000 mPas,… Heating apparatus for glass jacket system Separation chamber, 180x120x50 mm Measurespec spectrometer with cuvette… Spectrometer/goniometer with vernier Spectrophotometer 190-1100 nm Magnetic stirrer MR Hei-Standard Water separator GL25/12 Soxhlet attachment, GL25/12 Osmosis and electrochemistry chamber Funnel for gas generator, 50 ml, GL18 Condenser, reflux, with 2 Gl connection Half-shade polarimeter, 230 V AC Abbe refractometer Set rectification plant, 230 V Apparatus for elevation of boiling point Apparatus for freezing point depression Molecular model constuction kit, polymer… Molecular model construction kit, organic… Molecular orbital models, organics Crystal-lattice model sodium chloride Crystal-lattice model fluorite Crystal-lattice model ice Gasometer 1000 ml Gas bar Set gas laws with glass jacket, 230 V Set Gas laws with glass jacket system and… Set calorimetry, 230 V Electrolysis apparatus-Hofmann Manual centrifuge for 4 specimens Panel for complete experimental setups Drying oven UNB200, timer, 32 l Periodic system with colour pictures Magnetic stirrer Mini / MST Set of Precision Balance Sartorius CPA… Bubble bioreactor Grinding and polishing machine, 230 V…

Page 145 59 149 149 151 80 34, 43 30, 102 71 191 49, 99 33, 97 17, 24 23, 44 13 14 13 14 51, 101 64 81 117 73, 175 46, 107 82 56 48, 120 13 14 78 77 161 52 65 126, 132 35 94 157 164 109 171 123 96 119, 158 160, 177 21 22 154 178 137, 155 173 135 118 89, 139 38 20 72 25, 84 113 163 26, 174 192 29 106 16 188 180

PHYWE Systeme GmbH & Co. KG · www.phywe.com 211


12 Indices 12.2 Alphabetical Index

A

Absorption of light Absorption of X-rays Acetals Acetic acid Acetylene Acid Acid rain Acid-base titrations Acidic anions Acidification of soil and water Activation energy Activity Activity coefficient Adsorbent and adsorbate Adsorbent material AFM Air Air and other gases Alkali-organyls Alternative techniques e.g. Loschmidt's method Alternative techniques e.g. osmosis Aluminium Aluminothermics Amino acids Ammonia Ammonia preparation from the elements… Amontons' law Amphoteric electrolytes Analyser Angular momentum Anthropogenic air pollution Argentometry Arrhenius equation Atomic beam Atomic Force Microscope Atomic Force Microscopy Atomic form factor Atomic nuclei with a magnetic moment Atomic scattering factor Auger effect Average velocity Avogadro Avogadro's law Avogadro's number

B

Bacteria Bacterial culture Bacterial leaching Basic cations Benzaldehyde Binary system Binding energy Bioreactor Blast furnace process Bloch Blood Cells Bodenstein principle Bohr magneton Bohr model Boiling point Boiling point diagram Boiling point elevation Boyle and Mariotte's law Boyle temperature Bragg equation Bragg scattering Bragg-Brentano Geometry Bravais lattice Bremsstrahlung Briggs-Rauscher reaction Bromination Bromine Bubble bioreactor Bubble tray column Buffer Buffering capacity Building material Butterfly Wing

C

Calorimetry Cannizzaro reaction Capillary action Carbon monoxide Catalyst Cathode rays Ce(IV) sulphate Cell count Cell voltage Centrifugation Cerimetry Characteristic X-radiation Characteristic X-rays Charge Charge transport

66 57, 58 158 192 159 26, 94, 135 30 111 184 30 95 33 24, 50, 119 92 52 150 168 14 139, 154 76 79 37, 134, 182 37, 134, 182 190 156, 170 169 71 24, 50 56, 57, 145 126 30 49 95 130 150 150 143, 144, 145 62, 131 146, 147 57, 58 75 42 73 113 150 192 191 184 158 28, 121 127 188 157, 182 59 150 185 129, 130 58, 127, 129 119 160, 177 21 72 73 145, 146 143, 144, 146, 147 146, 147 145, 146, 147 56, 57, 58 43, 99 155 155, 159 191 124, 160, 176, 177 27, 50 24, 50 14 150 25, 82, 84, 85 158 52 39, 42, 136 178 128 48 189 47, 49 163 48 56, 57, 58, 143 146, 147 113 101, 102, 104

excellence in science 212

Charge transport in liquids Charles's (Amontons') law Chemical bonds Chemical equilibrium Chemical formula Chemical potential Chemical reactions Chlorine Chlorophyll Chromatogram Chromatography Clausius-Clapeyron equation Coefficient of thermal expansion Coexisting phase Coherent and incoherent photon scattering Column chromatography Complex formation Compounds Compton Concentration Concentration cells with transport Concentration cells without transport Concentration ratio Condensation Conductance Conductance and conductance measurements… Conductivity Conductivity measurement Conductivity-time plot Conductometry Constant-Height and Constant-Current-Mode Contact process Continuous and discontinuous distillation Corrosion Cracking Critical dissolution temperature Critical point Cryoscopic constant Crystal classes Crystal lattices Crystal structures Crystal systems Crystallisation Cubic compressibility coefficient

D

Damage to forests Daniell cell Debye-Scherrer Decadic molar extinction coefficient Decomposition of H2O2 Decomposition voltage Degree of dissociation Degree of freedom Dehalogenation Desulphurization Determination of molar masses according to the… Determination oft he solubility products Differential molar mixing enthalpy Diffraction image of a diffraction grating Diffraction spectrometer Diffractometry Diffusion Potential Directional quantization Dispersion Dissociation Dissociation constant and pKa value Dissociation equilibrium Dissociation of water Distillation Distillation column Distribution and extraction Doublets Ductility Dynamic and kinematic viscosity Dynamic Mode

E

Ebullioscopic constant Ebullioscopy Edge absorption Electric filter Electric potential Electrical conductance Electrochemical cells Electrochemical potential Electrochemical series of metals Electrode Electrode kinetics Electrode polarisation Electrode potential Electrode potentials and their concentration… Electrode reactions Electrode-electrolyte interface Electrodes of the 1st and 2nd type Electrolysis Electrolysis coulometry Electrolyte

103 71 13 16, 137 41 117, 118, 119 13 42, 135, 173 54 53 53 82 70 28 57 54 16, 137 136 56, 57, 143, 144 32 32, 109 31 117, 118 122, 124, 160, 176 105 98 102, 103, 107 100, 185 186 46, 97 148 171 124, 160, 176 112 178 28 73 22, 118 145 144, 145, 146, 147 143 144, 145, 146, 147 120 72 30 110 143, 144, 146, 147 66 187 114 117, 118 81 159 174 20 31 84 127 126 143, 144 32, 109 130 132 33 17, 34, 35 17, 34 24, 50 124, 155, 158, 161 160, 177 18 126 180 78 150 21, 117 21 57 175 116 46 108 110 116 116 112 51, 114, 115 49 108 110 112 49 51, 104, 114, 115 113 46


12 Indices 12.2 Alphabetical Index

Electrolyte solutions Electrolytic conductance Electrolytic resistance Electromotive force Electron charge Electron collision Electron conductivity Electron excitation Electron excitation spectroscopy (UV-VIS… Electron in crossed fields Electron mass Electron spin Electrophilic addition Electrostatic filter Elements Emulsion Energie dispersive measurement Energy detectors Energy dispersive Energy level Energy quantum Energy term symbols Enthalpy Enthalpy of combustion Enthalpy of condensation Enthalpy of formation Enthalpy of neutralisation Enthalpy of reaction Enthalpy of sublimation Enthalpy of vaporisation Entropy of vaporisation Enzymatic activity Enzymatic hydrolysis of urea Enzyme catalase Enzyme-substrate complex Enzymolysis of urea Equation of adiabatic change of state Equation of state Equation of state for ideal gases Equilibrium between phases Equilibrium constant Equilibrium diagram Equilibrium spacing Equivalence (inflection) points Equivalent conductance at infinite dilution Equivalent conductivity ESR Etching Ethanol Eutectic mixture Exchange energy Excitation energy Exergonic process Exhaust gas filter

F

Fabry-Perot interferometer Faraday's law Faraday's laws of electrolysis Fat extraction Feedback loop Fermentation Fertilizer Fick's laws of diffusion FID signal FID signal (Free Induction Decay) Finkelstein reaction First and second order reaction rates (laws) First law of thermodynamics First order reaction Flammersfeld oscillator Flue gas Fluidity Fluorescence Fluorescent yield Food analysis Food chemistry Formaldehyde urotropine Franck-Hertz experiment Freezing point depression Fuel cells Fundamental principles of thermodynamics Fundamentals of distillation Fusion enthalpy

G

G-factor Galvani voltage Galvanic cell Galvanic elements Gas chromatography Gas laws Gas volumetry Gas- Molecules Gaseous and aerosol emissions Gay-Lussac's law Gay-Lussac's law of chemical volumes General equation of state for ideal gases

102 33 105 31, 110 128 125 101 66 66 128 128 129, 130 159 175 136 163 56, 57, 145 58 57 56, 57, 58, 126 125 146 25, 84, 85 87, 90, 179 82 87, 88, 89 25, 85 88, 89 82, 86 82, 86 82 187 100, 185 187 185 186 80 19, 73 20, 81 18 16, 137 119 91 184 105 106, 107 64 181 162, 188 121 126 125, 126 43, 99 175 129 113, 114 104 164 149, 150 188, 189, 190 14 76 63 62, 131 97 98 81, 87, 88, 89 94, 96 80 174 78 56, 57, 143, 144 56, 57, 58 164 164 156 125 22 112 84 119 120 130 47 47 114 124, 159, 160, 176 42, 122 20 75 30 70, 73 73 73, 113

Gibb's phase law Gibbs-Helmholtz equation Gibbs' phase law Gibbs' phase rule Glas manufacture Glass electrode Goniometer Gravimetry Grignard reagent Grinding Ground and excitation states of molecules Grüneisen equation Gypsum Gypsum calcination Gyroscope

H

Haber-Bosch process Haemocytometer Half-cell Half-life Haloalkanes Halogen exchange rate Heat capacity Heat of combustion Heat of reaction Henderson-Hasselbalch equation Henry Freundlich and Langmuir adsorption isotherms Henry's / Dalton's law Henry's law Hess' law Hess' law of constant heat summation Hexagonal Structures Hexamethylenetetramine Hittorf numbers Human hair Hydrocarbons Hydrochloric acid Hydrogen Hydrolysis Hypsochromic and bathochromic shifts

I

Ideal and non-ideal behaviour of gases and liquids Ideal and ordinary gases Ideal gas law Ideal gases Imaging methods Imaging of biological samples Imaging on the sub nanometer scale Immobilised cells Indicators Influence of solvents Influence of temperature and pH Integral enthalpy of solution Integral molar mixing enthalpy Interaction potential Interference of electromagnetic waves Interionic action Internal friction Iodine Ion conductivity Ion mobility Ion solvation Ionic migration Iron Iron(II) sulphate Irreversible processes Isobars Isochors and adiabatic changes of state Isoelectric point Isotherms

J

Jablonski diagram and Förster cycle

K

Kinetic theory of gases Kinetics of the inversion of saccharose Kohlrausch's law

L

Lambert-Beer Law Larmor frequency Latent heat Lattice Lattice energy Lattice potential Laue Lauterbur Law of constant proportions Law of mass action Law of thermodynamics Layer-thickness Lead Leaf pigments Lennard-Jones-Potential Lewis acid

29 117, 118 121 86 14 24, 50, 111 132 51, 115 138 180 66 91 172, 174 172 64 169 189 116 93 138 97 25, 81, 85, 86 90, 179 90, 179 17, 24, 27, 34 92 160, 177 117 85, 89 87 148 156 104 150 178 26 42, 135 24, 50, 156 66 83 19, 20 23, 44, 70, 71 73 59 150 148 192 24, 50 66 187 85 84 73 129 107 77 123 46, 101 46, 103, 104, 105 85 102 37, 38, 134, 157 48 112 81 81 24, 50, 184 81 66 75, 76 96 105, 106 18, 35, 66 59 86 143, 144 85 91 143, 144, 145 59 73 17, 24, 34, 35 82 56, 57, 145 38, 39, 136 54 150 155

PHYWE Systeme GmbH & Co. KG · www.phywe.com 213


12 Indices 12.2 Alphabetical Index

Light scattering Limestone Linear expansion Lineweaver-Burk plot Liquid Liquid junction and diffucison potentials Liquid-liquid extraction Lithium organyls Local Density Of States (LDOS) Longitudinal and transverse magnetization Lorentz force Lyman-, Paschen-, Brackett and Pfund Series

M

Macromolecules Magnesium Magnetic field Magnetic induction Magnetic moment Magnetic Resonance Technology Magnetisation Mansfield Mark-Houwink equation Mass average and number average molecular weights Matrix effects Maxwell relationship Maxwellian velocity distribution Medical diagnostic Melt Melting Melting point Melting point diagram Metal microscopy Metallographic phases Metallographic preparation Metals Michaelis constant Micro distillation Microbial extraction Microbial synthesis of ethanol Micrography Miller indices Miscibility gap Miscible liquids Mixed crystal Mixed phase Mixtures Mobile phase Model kinetic energy Model of electrons in a unidimensional potential box Molar and partial molar quantities Molar mass Molar mass and relative molar mass Molar volume Mole volumes Molecularity of reaction Molecule radius Monochromatisation of X-rays Moseley's law Motor piston burette MR flip angle MR frequency MR physics MRI MRT Multi channel analyser Multiplicative distribution Multiplicity

N

n-propyl bromide Nano imaging Nanomorphology Nanotechnology Nernst distribution equation Nernst equation Nernst's law of distribution (number of… Neutralisation Newtonian liquid Nitric acid Nitrogen dioxide Nitrogen monoxide Nitrogen oxides NMR Non-invasive Nuclear spins

O

Optical rotation Ore Organometallic compounds Orthohelium Oscillating reactions Osmosis Osmotic pressure Ostwald capillary viscometer Ostwald process Ostwald's law of dilution

79 174 91 185 78 31 163 139, 154 148 63 128 127 79 94, 138 64 64 130 63 59, 62, 131 59 79 79 57, 58 132 75, 130 59 121, 135, 173 120 86, 121 121 181 181 180 14, 37, 134, 135 185 158 191 189 181 143, 144, 145, 146 28, 29, 121 28 121 28 13 52 75 66 83 21, 22, 23, 44 19 23, 44 81 93 73 146, 147 58 184 62, 63, 131 62, 63, 131 59, 62, 63, 131 59 59 56, 57, 58, 145 53 126 138 150 149 149 18 32, 47, 49, 108 53 27, 50 77, 78 168, 170 168, 170 168, 170 168 59, 62, 64, 131 59 59, 62, 63, 131 96 191 138, 139, 154 126 43, 99 32 32 79 170 105, 106

excellence in science 214

Overpotential Oxidation Oxygen

P

Parahelium Partial molar free enthalpy (chemical potential) Particle model PEM electrolyser PEM fuel cell pH indicators pH value Phase diagram Phosphoric acid Photometry Piezo-electric devices pKa value Planck's constant Plasticity Poiseuilles's equation Poisoning of enzymes Poisonous by product of cell respiration Polarimetry Polarisability Polarisation Polarography Polishing Polytropic equation Polyvalent acid Potential Potentiometric determination of pH Potentiometry Powder diffractometry Precession frequency Precession of nuclear spins Precipitation titration Pressure Principles of thermodynamics Prism Production of iron Properties of gases Properties of materials Proteolysis Proton-Exchange-Membrane (PEM) Purcell

Q

Qualitative analysis Quantisation of energy levels Quantitative analysis Quantum leap

R

Raoult's law Rate law for first and second order reactions Reaction kinetics Reaction molecularity Reaction order Reaction rate Reaction rate constant Reaction velocity of enzymatic hydrolysis Reactions with pseudo order Real and ideal behaviour Real gases Reciprocal lattice Rectification Redox electrodes Redox reaction Redox titration Reduction Reflux ratio Refractive index Relaxation times Relaxation times T1/T2 Relevance to electrolysis Resonance condition Resublimation Reveal crystallographic structure Rowland grating Rüchardt's experiment Rydberg frequency Rydberg's constant

S

Salt bridge Salt formation Saponification rate Scanning Tunneling Microscopy (STM) Scattering of X-rays Screening constant Selection rules Selectively permeable membrane Self and mutual diffusion coefficients Semi-permeable membrane Semiconductor Semiconductor energy detectors Separation of mixtures Separation procedure

51, 112, 115 38, 39, 42, 116 42 126 18 13 114 114 111 27, 50 29 27, 50 18, 35 148 27, 50, 184 127 77 79 100 187 96 132 112 112 180 80 27, 50 43, 99 111 17, 34, 47 143, 144 64 62, 63, 131 49 70, 71, 72 18, 83 132 157, 182 19 13 27, 50 114 59 56, 57, 145 129 51, 56, 57, 115 125 28, 117, 118, 119 93, 95, 97 94 98 93, 98 93, 95, 96, 97 93, 95, 98 186 95 84 73 143, 144, 145, 146 124, 160, 176, 177 108 37, 38, 39, 134 48 38, 39, 42, 116 160, 177 132 62, 131 59 112 62, 63, 131 123 181 132 80 58 127 31 135 93 148, 149 58 58 126, 146 32, 109 76 32, 109 58 56, 57, 58 13 52, 163


12 Indices 12.2 Alphabetical Index

Shaking Shear stress Signal-to-noise ratio Silver nitrate inhibition of urease Silver/silver nitrate half-cell Single crystal Single electron atom Skin Cross-Section Slug Sodium hydroxide Sodium thiosulphate Solubility Solubility product Solution Solvatochromic Soxhlet apparatus Specific and molar conductivity Specific conductance Spectrometer Spectroscopical energy and adsorption measurement Spectroscopy Spin Spin echo Spin-lattice relaxation Spin-orbital angular momentum interaction Spin-spin relaxation SPM Starch-iodine solution Static mode Stationary phase Steam distillation Stern-Gerlach experiment STM Stoichiometry Stokes' law Strong and weak acids Strong and weak electrolytes Structure amplitude Structure analysis Structure factor Sublimation Substituent effects Substrate inhibition Sulphate Sulphur Sulphur trioxide Sulphuric acid Supercooled melt Surface Chemistry Surface Physics

T

T1/T2 relaxation times Temperature Temperature-dependence of conductivity Test reactions Thermal capacity Thermal capacity of gases Thermal conductivity detector Thermal expansion Thermal tension coefficient Thermite process Thermochemistry Thermolysis Thin layer chromatography Three component system Titration Titration curves Toluene Tomography Transference numbers Transport properties Triangular diagram Trouton's rule True and potential electrolytes Tunneling effect Tunneling Effect Turbidimetry Two-wire field Types of electrodes

U

Universal gas constant UV-VIS spectrometry UV-VIS spectroscopy

V

Van der Waals equation Van't Hoff factor Vaporisation Vapour pressure Velocity distribution Velocity gradient Vibration amplitude Vinegar procedure Viscosity Viscosity measurements Viscosity of liquids

163 77 62, 131 100 116 143, 144 127 150 157, 182 27, 50 120 26, 33, 58, 123 49, 58 116 66 164 105 46 132 66 56, 57, 145 126 59, 62, 131 63 126 63 149 135, 173 150 52 124, 161 130 148, 149 41, 122 78 17, 34, 35 24, 50 144, 145 143, 144 143, 146, 147 123 17, 34 186 172 174 171 171, 172 120 149 149

Visible spectral range Voltammetry and current-potential curves Volume Volume contraction Volume expansion of liquids Volumetry

W

Water - components of water and water purification Wave mechanics atomic model Welding of iron Wurtz synthesis

X

X-ray X-ray energy detector X-ray expert unit X-ray fluorescence analysis X-ray upgrade set Xanthophyll XRED

Y

Yeast

Z

Zeeman effect Zwitterions Zymomonas mobilis

127 112 70, 71, 72 83 91 46, 47, 92 14 66 37, 134, 182 139, 154 56, 57, 58, 143 56, 57, 145 56, 57, 143, 144 56, 57, 145 56, 57, 143, 144 54 57 188, 189 129 184 189

63 70, 71, 72, 75 106 13 91 80 53 91 71 37, 134, 182 88, 89 38 52, 190 29 48, 184 24, 50 155 59 32, 104, 105, 109 76 29 82 17, 34, 35 148 149 189 130 47 70, 71, 72, 81 35 66 73 118 124, 160, 176 82, 124, 160, 176 75 77 150 192 77, 105 78 79

PHYWE Systeme GmbH & Co. KG · www.phywe.com 215


12 Indices 12.3 www.PHYWE.com

excellence in science 216


Service

Service from A to Z – our service, your satisfaction

Customer service before, during and after your purchase The PHYWE service does not end with the delivery of the equipment. With our after sales service, we offer you comprehensive support:

Individual Service for individual needs By choosing a PHYWE product you decide for a comprehensive service at the same time. We support you with our multi-level service concept. From planning through to installation and up to our extensive after sales service. Rely on our strengths: rugged and long-lasting products made in Germany, customized for your needs.

Customized information

Installation and setting-up

Stockage service / instruction

Training courses at PHYWE or on-site

Technical service

Repair service

1st response within 24 hours P. +49 (0) 551 604-196 F. +49 (0) 551 604-106 service@phywe.de

excellence in science


expert

TESS

s n o i t u l o s s s Worldcla : n o i t a c u d e r e t t e b r o f m o c . e w y h p . w ww

TESS

Global network Your partner is never far away! HEADQUARTERS/PRODUCTION GÖTTINGEN, GERMANY

expert

EASTERN EUROPE EUROPE

MIDDLE EAST

ASIA-PACIFIC

Tel. +49 (0) 551 604 - 0 Fax +49 (0) 551 604 - 107 info@phywe.com

More than 600 experiments

16504-42

Find more Laboratory Experiments in our special ­catalogues Physics, Biology, Engineering and Medicine.

excellence in science

AMERICAS

Our worldwide presence enables us to offer you customised local solutions. More than 145,000 customers in over 95 countries appreciate our experience and reliability, our high technical standards, and the ease and clarity with which our innovative products can be operated. Are you looking for a partner near your location? Please do not hesitate to call us. We would be pleased to assign you a personal contact.

Laboratory Experiments Chemistry

PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen

© Copyright by PHYWE Systeme GmbH & Co. KG. Subject to change without notice. Errors and omissions excepted. Edition 12/2012

AFRICA

Laboratory Experiments Chemistry School · University

excellence in science

HEADQUARTERS/PRODUCTION PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen Germany P. +49 (0) 551 604-0 F. +49 (0) 551 604-107 info@phywe.com

excellence in science

AMERICAS P. +49 (0) 551 604-119 F. +49 (0) 551 604-115 america@phywe.com

EASTERN EUROPE P. +49 (0) 551 604-233 F. +49 (0) 551 604-115 oe@phywe.com

AFRICA P. +49 (0) 551 604-323 F. +49 (0) 551 604-115 africa@phywe.com

MIDDLE EAST P. +49 (0) 551 604-222 F. +49 (0) 551 604-115 nmo@phywe.com

EUROPE P. +49 (0) 551 604-254 F. +49 (0) 551 604-115 we@phywe.com

ASIA-PACIFIC P. +49 (0) 551 604-245 F. +49 (0) 551 604-115 asia@phywe.com


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.