www.fgks.org   »   [go: up one dir, main page]

091023 EQUIPMENTS

Page 1

ServiceCentre

The Lab Modular System

Easy Navigation Concept

EQUIPMENTS

4.1 Frame Heaters

4.2

Lamp for frames

4.3 Ultrasonic Cleaners

4.4

2
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
EQUIPMENTS AND APPLIANCES 4.0
• Aluminium - Single air flow Multiple temperature setting 6 • Dual air flow - Two temperature settings ........... 10 • Dual air flow - Multiple temperature settings .. 11
• Germicidal device with timer - 8 frames 14 • Germicidal device with timer - 15 frames 15 • Germicidal device with timer - 30 frames .......... 15
Germicidal
• Digital setting - Continuous vibrations 0,6 l 18 • Digital setting - Continuous vibrations 0,8 l 19 • Digital setting - Continuous vibrations 1,4 l ..... 20 • S/steel - Variable Timer Switch ................................ 21 • S/steel with adjustable heating 22
Testers • Marking identifier for progressive lenses 26, 32 • Strain gauge 27, 33 • Photochromic tester ......................................... 28, 31 • Polarized Tests ...................................................... 29 • Light pad 30

4.5

4.6

4.7 Soldering Units

4.8

3 4.0 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
• Automatic lens groover 36 • Hand edger 38 • Professional hand edger .......................................... 39 • Hand edger with front facing diamond wheel ... 40 • Dual speed bench polisher 41
Hand Edgers and Bench Polisher
Drills and Millers • Proxxon hand drill 44 • Proxxon bench press drill 45 • Lens drilling system for rimless frames .............. 46 • Centring device for lens drilling system ............ 46
• Hinge embedding unit 216 • Electric soldering carbon welding units 217 • Soldering units - Water electrolisys system ...... 218 • Miniflam torch ............................................................. 220 • Soldering consumables 221 • Soldering steps 222
Tinting units • Two electric plates 60 • Four electric plates 61 • Automatic gradation unit ...................................... 62 • Accessories for tinting .............................................. 63 • Do’s and don’ts of tinting 64

FRAME HEATERS 4.1

Frame heaters for the practice

With closed lid temperature rises up to +20/30°C

The diffuser allows an even temperature in the cup and reduces the risk of frame damage from overheating

4
ALL
© LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX Page
RIGHTS RESERVED
AIR FLOW Even temperature
7
Page 8 Page 9 Page 6

FRAME HEATERS 4.1

Frame heaters for the practice and the lab

Heater systems, more commonly called frame heaters, are used with plastic frames to make them malleable and modifiable, both to facilitate the insertion of the lenses, and to adjust temple tips, temples and fronts based on the facial features of the person who will then be wearing the glasses. The adjustment of the frame will make the glasses more stable and more comfortable by ensuring the correct positioning of the optical centre of the lenses on the face.

There are various types of frame heaters: laboratory or bench and vertical or horizontal, depending on the habits and needs of the user. The units take advantage of a single or double airflow to ensure greater heating uniformity of the frame to be adjusted.

Sometimes it may be useful to be able to concentrate the heat at a more specific point such as the bridge of the glasses. To do this, there is an accessory called a heat concentrator that can be easily applied to the frame heater when needed.

5
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES Even temperature Even temperature Even temperature Even temperature
10
Page
11 AIR FLOW AIR FLOW
Page

ALUMINIUM FRAME HEATER 4.1

Single air flow - Multiple temperature setting

Even temperature

With closed lid temperature rises up to +30°/40°C

FRAME HEATER HORIZONTAL

Ref. 05017

Constant air temperature, controlled by variable thermostat with one cooling setting

• Heat concentrator included.

• Internal temperature regulator.

• Heat resistant plastic cup and lid. Air temperature: with open lid 150°C with closed lid 190°C

Overall measurements:

116x150x300 mm

Weight: 1.8 kg

PLUG SUPPLIED

Ref. 05017 230V AC

Ref. 05017CH 230V AC

Ref. 05017GB 230V AC

Ref. 05017AUS 230V AC

SPARE PARTS

Ref. 05020.3

Heat concentrator

Concentrated temperature

• Designed to direct the hot air onto a specific part of the frames, e.g. the bridge

6
ALL RIGHTS RESERVED © LAB
FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 40” FRAME HEATED UP IN 350 WATT POWER CONSUMPTION ~150° ~190°
RANGE AIR FLOW
MOD SYSTEM
TEMPERATURE
AIR FLOW
HOT AIR COLD AIR

ALUMINIUM FRAME HEATER 4.1

Single air flow - Multiple temperature setting

Even temperature

With closed lid temperature rises up to +30°/40°C

AIR FLOW

Ref. 05019 230V AC

Ref. 05019CH 230V AC

Ref. 05019GB 230V AC

Ref. 05019AUS 230V AC

AIR FLOW

• Designed to direct the hot air onto a specific part of the frames, e.g. the bridge

FRAME HEATER

UPRIGHT

Ref. 05019

Constant air temperature, controlled by variable thermostat with one cooling setting

• Heat concentrator included.

• Internal temperature regulator.

• Heat resistant plastic cup and lid. Air temperature: with open lid 150°C with closed lid 190°C

Overall measurements:

152x180x322 mm

Weight: 1.8 kg

SPARE PARTS

Ref. 05020.3

Heat concentrator

TEMPERATURE

Concentrated temperature 40”

FRAME HEATED UP IN

7
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
~190°
350 WATT POWER CONSUMPTION ~150°
RANGE HOT AIR COLD AIR
PLUG SUPPLIED

FRAME HEATER 4.1

Single air flow - One temperature setting

Even temperature

With closed lid temperature rises up to +20/30°C

The diffuser allows an even temperature in the cup and reduces the risk of frame damage from overheating

AIR FLOW

Concentrated temperature

• Designed to direct the hot air onto a specific part of the frames, e.g. the bridge

AIR FLOW

• Heat concentrator included.

• Internal temperature regulator.

• Heat resistant plastic cup and lid. Air temperature: with open lid 120°C with closed lid 140°C

SPARE PARTS

Ref. 05020.3 Heat concentrator

Ref. 05020.1 Heating element

Ref. 05020.5 Switch ON/OFF

FRAME HEATER UPRIGHT

Ref. 05022

Overall measurements:

140x140x300 mm

Base: 140x140 mm

Weight: 1.8 kg

FRAME HEATER HORIZONTAL Ref. 05020

Overall measurements: 110x110x250 mm

Weight: 1.8 kg

8
ALL RIGHTS RESERVED © LAB
SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 450 WATT POWER CONSUMPTION 40” FRAME HEATED UP IN ~120° ~140° TEMPERATURE RANGE
MOD
Ref. 05020/05022 230V AC Ref. 05020/05022CH 230V AC Ref. 05020/05022GB 230V AC Ref. 05020/05022AUS 230V AC PLUG SUPPLIED

FRAME HEATER 4.1

Single air flow - Multiple temperature settings

Even temperature

With closed lid temperature rises up to +20/30°C

The diffuser allows an even temperature in the cup and reduces the risk of frame damage from overheating

AIR FLOW

Concentrated temperature

• Designed to direct the hot air onto a specific part of the frames, e.g. the bridge

AIR FLOW

FRAME HEATER

MULTIPLE TEMPERATURE

Ref. 05030

• Variable electronic temperature

• control from 75°C to 180°C.

• Constant air stream.

• Heat concentrator.

• Heat diffuser cup with lid.

Size: 105x160x255 mm

Weight: 1.5 kg.

SPARE PARTS

Ref. 05030.1 - Heating element

Ref. 05030.2 - Heat diffuser cup with lid

Ref. 05030.3 - Heat concentrator

PLUG SUPPLIED

Ref. 05030 230V AC

Ref. 05030CH 230V AC

Ref. 05030GB 230V AC

Ref. 05030AUS 230V AC

FRAME HEATED UP IN

9
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES 90 75 100 110 160 140 130 120 180 Multiple temperature setting 300 WATT POWER CONSUMPTION ~75° ~180° TEMPERATURE RANGE
40”

FRAME HEATER 4.1

Dual air flow - Two temperature settings 75°C and 140°C

Concentrated temperature

• Designed to direct the hot air onto a specific part of the frames, e.g. the bridge

FRAME HEATER

Ref. 05024

• Constant air temperature

• controlled by internal thermostat.

• Two temperature settings,

• 75°C and 140°C.

• Heat resistant plastic vents and lid.

• Heat resistant plastic heat concentrator included.

• Incorporates safety thermal cut-out switch.

Size: 200x144x213 mm

Weight: 1.6 kg.

Ref. 05024 230V AC

Ref. 05024CH 230V AC

Ref. 05024GB 230V AC

Ref. 05024AUS 230V AC

SPARE PARTS

Ref. 05024.3 Heat concentrator

Ref. 05024.1 Heating element

Ref. 05020.5 Switch ON/OFF

Ref. 05024.6 SPDT Switch

LOW TEMPERATURE 75°C: for polycarbonate and special frame materials e.g. optyl, polyamide, compounds.

MEDIUM/HIGH TEMPERATURE 140°C: for traditional materials.

10
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
900 WATT POWER CONSUMPTION ~75° ~140°
RANGE 30” FRAME HEATED UP IN AIR FLOW Even temperature Even temperature AIR FLOW
TEMPERATURE
PLUG SUPPLIED

FRAME HEATER 4.1

Dual air flow - Multiple temperature settings

Concentrated temperature

• Designed to direct the hot air onto a specific part of the frames, e.g. the bridge

Dual air streams, even temperature on rim without having to move frame

MULTIPLE TEMPERATURE SETTING

Ref. 05015

Constant air temperature, controlled by variable thermostat.

Two heat and one cooling settings:

1. Using the 1st heat setting:

• Middle temperature 75°C – 100°C (167-212°F), controlled by variable thermostat.

2. Adding the 2nd heat setting:

• High temperature 120°C -160°C (248-320°F), controlled by variable thermostat.

3. Cooling setting:

• Separate cooling setting for cool air.

• Heat resistant plastic concentrator included Ref. 05014.

• Incorporates safety thermal cut-out switch.

PLUG SUPPLIED

Ref. 05015 230V AC

Ref. 05015CH 230V AC

Ref. 05015GB 230V AC

Ref. 05015AUS 230V AC

Dimensions: 190x300x200 mm -

SPARE PARTS

Ref. 05011

Heating element

Ref. 05014

Heat concentrator

Weight: 2.4 kg

11
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES RANGE 2 °C RANGE 1 °C HOT AIR COLD AIR POWER CONSUMPTION 750 MIN. 1500 MAX. WATT ~75° ~100° ~120° ~160° 25”
AIR FLOW Even temperature Even temperature AIR FLOW
FRAME HEATED UP IN

GERMICIDAL LAMP FOR FRAMES 4.2

Germicidal device with UVC rays 253.7 nm with timer

8 frames

30 frames 15 frames

12
ALL
© LAB MOD
FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
RIGHTS RESERVED
SYSTEM
Page 14
Page 15 Page 15

• This machine has a special germicidal lamp powered with 253.7 nm UVC rays that quick ly remove ever y single micro - organism.

• Frames and tools once disinfec ted can be kept for a long time, enabling them to be stored and ready for use. The treatment does not generate heat.

• Ideal for the treatment of frames, test lenses and flippers.

• The inside shelf keeps the items away from the reflective sur face in order that the rays uniformly coat the produc ts, so as to optimize germicidal ac tion. For a better result we suggest you do not place items on top of each other.

• The security of the operator is guaranteed by a micro -switch that switches off the lamp whenever the door is open.

• Solidly built, the ex ternal metal par ts have a coated sur face whilst the inside is shiny stainless steel with the viewing door fitted to protec t from the UVC rays

• We suggest you disinfec t any frames chosen by your customer prior to fitting/wearing

• For frames with ophthalmic and special treatment lenses we suggest you remove the lenses first

• A continuous treatment can cause the lenses to yellow.

13 4.2 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES

GERMICIDAL LAMP FOR FRAMES 4.2

Germicidal device with UVC rays 253.7 nm with timer

8 FRAMES

Ref. 05040

It can holds up to 8 frames.

Accessories included:

• 1 Spray Clean 60 ml antibacterial

• 3 microfibre gloves

TECHNICAL FEATURES

Energy consumption: 10W

Power consumption: 8W

Power Supply : 230V/50 Hz

Smaller dimensions, ideal for a prac tice with limited space.

Ref. 05040 230V AC

Ref. 05040CH 230V AC

Ref. 05040GB 230V AC

Ref. 05040AUS 230V AC

SPARE PARTS

Ref. 05040.1

Germicidal lamp 8W

L = 28.5 cm

Ref. 05041.1

Germicidal lamp 15W

L = 43.5 cm

Ref. 05042.1

Germicidal lamp 30W

L = 89.5 cm

For Ref. 05040, 05041, 05042.

EUROPEAN DIRECTIVE 2014/35/EU, 2014/30/EU, 2011/65/EU

Time for bac teriological load reduc tion from 60 to 90 seconds

Complete germicidal ac tion: 5 minutes

We suggest you do not leave the frames for longer than sugge sted, and inser t them with open temples.

14
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
160 mm 200 mm
370 mm - Weight 4.6 kg
IT IS NOT A MEDICAL DEVICE
PLUG SUPPLIED
VIDEO

GERMICIDAL LAMP FOR FRAMES 4.2

Germicidal device with UVC rays 253.7 nm with timer

15 FRAMES Ref. 05041

It can holds up to 15 frames.

Accessories included:

• 1 Spray Clean 60 ml antibacterial

• 3 microfibre gloves

490 mm - Weight 9.5 kg

30 FRAMES Ref. 05042

It can holds up to 30 frames.

Accessories included:

• 1 Spray Clean 60 ml antibacterial

• 3 microfibre gloves

980 mm - Weight 12.0 kg

15
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
200 mm 270 mm
200 mm 270 mm TECHNICAL FEATURES Energy consumption: 18W Power consumption: 15W Power Supply : 230V/50 Hz TECHNICAL FEATURES Energy consumption: 35W Power consumption: 30W Power Supply : 230V/50 Hz Ref. 05042 230V AC Ref. 05042CH 230V AC Ref. 05042GB 230V AC Ref. 05042AUS 230V AC PLUG SUPPLIED Ref. 05041 230V AC Ref. 05041CH 230V AC Ref. 05041GB 230V AC Ref. 05041AUS 230V AC PLUG SUPPLIED

ULTRASONIC CLEANERS 4.3

Digital Ultrasonic Cleaners

16
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 0,6 litres 1,4 litres 0,8 litres
Page 18
Page 19 Page 20

ULTRASONIC CLEANERS 4.3

Stainless Steel Ultrasonic Cleaners (Made in Germany)

0,8 litres

litres with heating

litres with heating

Ultrasonic cleaners employ high frequency energy generated electronically by a transmitter in the unit. The electrical energy generated is transformed into sound waves by a device known as “transducer”. Ultrasonic cleaners are easy to operate, require no maintenance and are economical to utilize due to the semiconductors technology. They are the ideal equipment for the cleaning of frames and parts. The use of antibacterial detergent Active Liquid Ref. 06859 is recommended.

17
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
2,75
0,8
Page 21 Page 22 Page 23

ULTRASONIC CLEANER 4.3

Digital setting - Continuous vibrations - 0,6 litres

DIGITAL ULTRASONIC CLEANER - 0,6 LITRES Ref. 05443

Ultrasonic cleaner with stainless steel 0,6 l tank ideal for the cleaning of frames.

• Programming of 5 washing cycles from 90 to 480 seconds.

• Automatic stop at the end of the cycle.

• Transparent cover with automatic opening.

• Internal blue led illumination.

Accessories included:

• Plastic mesh basket.

• Watch, jewellery and CD holders.

• Antibacterial detergent Active Liquid 150 ml (for re-orders Ref. 06859 1 litre).

Dimensions:

External: 158x210x125 mm.

Basket: 122x144x42 mm.

Weight: 1,10 kg

PLUG SUPPLIED

Ref. 05443 230V AC

Ref. 05443GB 230V AC

Ref. 05443AUS 230V AC

18
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 50 WATT POWER CONSUMPTION 0,60 LITRES CAPACITY 42 KHZ FREQUENCY
RIGHTS

ULTRASONIC CLEANER 4.3

Digital setting - Continuous vibrations - 0,8 litres

DIGITAL ULTRASONIC CLEANER - 0,8 LITRES Ref. 05448

Ultrasonic cleaner with stainless steel 0,8 l tank ideal for the cleaning of frames.

• Programming of 5 washing cycles from 60 to 300 seconds.

• Automatic stop at the end of the cycle.

• Transparent cover.

Accessories included:

• Plastic mesh basket.

• Watch and jewellery.

• Antibacterial detergent Active Liquid 150 ml (for re-orders Ref. 06859 1 litre).

Dimensions:

External: 220x138x141 mm.

Basket: 160x95x55 mm.

Weight: 1,60 kg

Ref. 05448 230V AC

Ref. 05448GB 230V AC

19
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES 55 WATT POWER CONSUMPTION 0,80 LITRES CAPACITY 40 KHZ FREQUENCY
PLUG SUPPLIED

ULTRASONIC CLEANER 4.3

Digital setting - Continuous vibrations - 1,4 litres

DIGITAL ULTRASONIC CLEANER 1,4 LITRES

Ref. 05446

Ultrasonic cleaner with stainless steel 1,4 l tank:

• Programming of the washing cycles from 90 to 480 seconds.

• Memorization up to 5 washing programs.

• Automatic stop at the end of the cycle.

Accessories included:

• Plastic mesh basket.

• Antibacterial detergent Active Liquid 150 ml (for re-orders Ref. 06859 1 litre).

Dimensions:

External:180x230x160 mm.

Tank:140x170x160 mm.

Weight: 1,75 kg

PLUG SUPPLIED

Ref. 05446 230V AC

Ref. 05446GB 230V AC

Ref. 05446AUS 230V AC

20
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 100 WATT POWER CONSUMPTION 1,4 LITRES CAPACITY 42 KHZ FREQUENCY
RIGHTS

STAINLESS STEEL ULTRASONIC CLEANER 4.3

Variable timer switch - 0,8 litres

ACCESSORIES

Ref. 05451

Stainless steel mesh basket for ultrasonic cleaner Ref. 05450 and Ref. 05456.

ULTRASONIC CLEANER - 0,8 LITRES

Ref. 05450

Stainless steel ultrasonic cleaner:

• Variable ± timer switch 0-30 min.

• Sweep function for optimised sound field distribution in the cleaning liquid

• Degas function for the efficient degassing of the cleaning liquid and for laboratory purposes

• Plastic lid included

• Powerful cleaning action.

• Antibacterial detergent Active Liquid 150 ml. (for re-orders Ref. 06859 1 litre).

• Made in Germany.

PLUG SUPPLIED

Ref. 05450 230V AC

Ref. 05450CH 230V AC

Ref. 05450GB 230V AC

Ref. 05450AUS 230V AC

Dimensions:

External: 206x116x178 mm.

Tank: 190x85x60 mm.

Weight: 2.0 kg.

21
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES 30 WATT POWER CONSUMPTION 0,8 LITRES CAPACITY 37 KHZ FREQUENCY

STAINLESS STEEL ULTRASONIC CLEANER 4.3

With adjustable heating - 0,8 litres

ULTRASONIC CLEANER - 0,8 LITRES

Ref. 05456

Stainless steel ultrasonic cleaner:

• Variable ± timer switch 0-30 min.

• Adjustable temperature range from 30°C to 80ºC

• Sweep function for optimised sound field distribution in the cleaning liquid

• Degas function for the efficient degassing of the cleaning liquid and for laboratory purposes

• Plastic lid included

• Antibacterial detergent Active Liquid 150 ml (for re-orders Ref. 06859 1 litre).

• Made in Germany.

Dimensions:

External: 206x116x178 mm.

Tank: 190x85x60 mm.

Weight: 2.0 kg.

PLUG SUPPLIED

Ref. 05456 230V AC

Ref. 05456CH 230V AC

Ref. 05456GB 230V AC

Ref. 05456AUS 230V AC

ACCESSORIES

Ref. 05451

Stainless steel mesh basket for ultrasonic cleaner

Ref. 05450 and Ref. 05456.

22
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX ~30° ~80° TEMPERATURE RANGE 90 WATT POWER CONSUMPTION 0,8 LITRES CAPACITY 37 KHZ FREQUENCY

STAINLESS STEEL ULTRASONIC CLEANER 4.3

With adjustable heating - 2,75 litres

ACCESSORIES

Ref. 05461

Stainless steel mesh basket for ultrasonic cleaner

Ref. 05470

ULTRASONIC CLEANER - 2,75 LITRES

Ref. 05470

Stainless steel ultrasonic cleaner:

• Variable ± timer switch 0-30 min.

• Adjustable temperature range from 30°C to 80ºC

• Sweep function for optimised sound field distribution in the cleaning liquid

• Degas function for the efficient degassing of the cleaning liquid and for laboratory purposes

• Plastic lid included

• Antibacterial detergent Active Liquid 150 ml (for re-orders Ref. 06859 1 litre).

• Made in Germany.

Dimensions:

External: 300x179x214 mm.

Tank: 240x137x100 mm.

Weight: 3.3 Kg.

PLUG SUPPLIED

Ref. 05470 230V AC

Ref. 05470CH 230V AC

Ref. 05470GB 230V AC

Ref. 05470AUS 230V AC

23
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES ~30° ~80° TEMPERATURE RANGE 275 WATT POWER CONSUMPTION 2,75 LITRES CAPACITY 37 KHZ FREQUENCY
24
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
TESTERS 4.4
Page 26 Page 27 Page 28
Marking Identifier Strain Gauge Photochromic Lens Tester

Polarized Test Light Pad

Innovative equipment with long-lasting and low-consumption LED technology. Specifically designed to help opticians check lenses or sunscreens.

• Led light marking identifier to check the markings on progressive lenses.

• Led strain gauge to detect stress in fitted lenses.

• Photochromic test to demonstrate the photochromic properties of the lenses and verify the correct colour shade.

• UV & Visible Spectrotester for UV % and visible transmittance analysis %.

• Light pad to faithfully display the tint of the sun lenses.

25 TESTERS 4.4 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
Page 29 Page 30

LED LIGHT MARKING IDENTIFIER 4.4

To check manufacturer’s markings on progressive lenses

Long lasting LED technology

White light

Low power consumption

Ref. 05054

The LED technology marking identifier has:

• High luminosity LED illumination

• Adjustable inclination for improved reading

• Pre-printed background to highlight contrast

On progressive lenses this instrument allows identification of:

• Manufacturer’s markings

• Lens type ID

• Added power

This instrument is suitable to check the values of a lens or to redefine the centres of a progressive lens for re-glazing.

How to use:

• Place the lens or the frame with the lens onto the contrast base and approach it to the magnifier until you can read the manufacturer’s markings.

Size: 143 x 145 x 220 mm

Maximum height (at highest extension): 255 mm

Weight: 0.66 kg

Power supply: 230V AC (12V 1A with transformer)

PLUG SUPPLIED

Ref. 05054 230V AC

Ref. 05054GB 230V AC

Ref. 05054AUS 230V AC

Ref. 05054USA 115V AC

R 2.00VIP
26
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 12 WATT POWER CONSUMPTION
VIDEO

To detect stress in fitted lenses

Long lasting LED technology White light Low power consumption

Ref. 05057

This instrument shows:

• Stress in fitted lenses, usually in the parts of the lens with the highest curvature or pressure

• Chips in glass lenses

• Tempering treatment of a glass lens (shown by a cross shaped shadow in the centre of the lens)

The strain gauge has:

• High luminosity large diffusion LED illumination for better contrast

• Adjustable inclination for improved reading

Size: 143 x 145 x 145 mm

Maximum height (at highest extension): 200 mm

Weight: 0.6 kg

Power supply: 230V AC (12V 1A with transformer)

PLUG SUPPLIED

Ref. 05057 230V AC

Ref. 05057GB 230V AC

Ref. 05057AUS 230V AC

Ref. 05057USA 115V AC

27
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
LED STRAIN GAUGE 4.4
12 WATT POWER
CONSUMPTION
VIDEO

PHOTOCHROMIC LENS TESTER WITH LED LIGHT PAD 4.4

To test and demonstrate the photochromic properties of a lens

Long lasting LED-technology

UV-LED for photochromic testing

Light pad with white LED light (5350 K)

Low power consumption

Ref. 05063

The photochromic lens tester with LED technology allows to quickly demonstrate the photochromic properties of a lens.

• Place the lens onto the lower surface under the UV LED lamps. The lens will darken in approx. 10 sec. The UV LED light does not alter the lens’s photochromic properties.

• Place the lens onto the upper light pad to check the colour intensity.

The white LED light simulates sunlight and allows to show the colour shade of a sunlens in a realistic way. It avoids colour alteration caused by artificial light.

Power supply: 230 V AC (12V 2A with transformer)

Dimensions: 220x145x210 mm.

Weight: 0.80 kg.

POWER CONSUMPTION

24 WATT

PLUG SUPPLIED

Ref. 05063 230V AC

Ref. 05063GB 230V AC

Ref. 05063AUS 230V AC

28
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
Ref. 05063USA 115V AC VIDEO

POLARIZED TESTS 4.4

To simulate polarized vision

IDEAL TEST TO HIGHLIGHT THE ADVANTAGES OF A POLARIZED VISION USING GLASSES WITH POLARIZED LENSES.

Ref. 06596

Plexiglass display with road safety-oriented graphics.

Dim.: Display: 170x160 mm - Imagine: 150x100 mm

Weight: 110 gr. 1 pc.

Ref. 06597

Plexiglass display with graphics to highlight the contrast of colors in full sun.

Dim.: Display: 170x160 mm - Imagine: 150x100 mm

Weight: 110 gr. 1 pc.

Ref. 06598

PVC Card with color effect for a quick polarized vision test.

Dim.: Card: 85x55 mm - Imagine: 50x20 mm

Weight: 5 gr. 10 pcs.

NEW NEW NEW NEW
29
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
RIGHTS
Vision with polarized lenses. Vision with polarized lenses.

LIGHT PAD 4.4

White LED 5350 Kelvin sunlight

Long lasting LED technology

White LED light 5350 Kelvin Low power consumption

Ref. 05049

The LED technology light pad allows to quickly demonstrate the colour intensity of a lens.

The white LED light simulates sunlight and allows to show the colour shade of a sunlens in a realistic way. It avoids colour alteration caused by artificial light.

Power supply: 230 V AC (12V 0.3A with transformer)

Dimensions: 220x145x31 mm.

Weight: 0.60 kg.

PLUG SUPPLIED

Ref. 05049 230V AC

Ref. 05049GB 230V AC

Ref. 05049AUS 230V AC

Ref. 05049USA 115V AC

POWER CONSUMPTION

WATT

30
ALL
©
FRAME
LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
RIGHTS RESERVED
LAB MOD SYSTEM
PARTS
12

PHOTOCHROMIC TESTER 4.4

To test and demonstrate the photochromic properties of the lens

PHOTOCHROMIC LENS TESTER

Ref. 05062

To test and demonstrate the photochromic properties of the lens. Place the lens under the lamp. It will begin to darken - takes approx. 15 sec. When the lens has darkened, place it on top of the unit for colour and intensity comparison. The lamp does not damage the photocromic properties of the lens.

Size: 210x130x130 mm

Weight: 1.75 kg.

SPARE PARTS

Ref. 05060.1

UV lamp

Ref. 05062 230V AC

Ref. 05062CH 230V AC

Ref. 05062GB 230V AC

Ref. 05062AUS 230V AC

31
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES 15 WATT POWER CONSUMPTION
PLUG SUPPLIED

LED LIGHT MARKING IDENTIFIER 4.4

To check manufacturer’s marking on progressive lenses

MARKING IDENTIFIER

Ref. 05065

Instrument for checking CR39, polycarbonate and high index lenses.

This device will greatly assist in the quick and easy location of the various manufacturers’ marks placed on progressive lenses.

This is achieved by special background contrasting and lighting. The mounted magnifier assists in the reading of these marks.

• manufacturer’s markings.

• lens type ID.

• added power.

These markings identifications have been improved by:

• 5000°K led illumination.

• Adjustable inclination for a better reading.

Power supply: 230 V AC (12V with transformer)

Size: 155x135x270 mm

Weight: 0.9 kg

Ref. 05065 230V AC

Ref. 05065CH 230V AC

Ref. 05065GB 230V AC

Ref. 05065AUS 230V AC

R 2.00VIP NEW
32
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 4,5 WATT POWER CONSUMPTION
RIGHTS
PLUG SUPPLIED

LED STRAIN GAUGE 4.4

To detect stress in fitted lenses

STRAIN GAUGE

Ref. 05068

To detect stress in fitted lenses. Fitting lenses into frames always produces stress in lenses. Identifying the stress quickly with the help of this Strain Gauge will prevent chipping and breaking of glass lenses and distortions in organic lenses.

This instrument has been improved by:

• 5000°K led illumination.

• Adjustable inclination for a better check.

The Strain Gauge will also indicate if a lens has been toughened by the heat method. This is shown by a “cross” shadow in the lens. We recommend that you test the lens stress using our Size Testing Plier Ref. 03330 before assembly.

Power supply: 230V AC (12V with transformer)

Size: 155x135x167 mm.

Weight: 0.8 kg.

Ref. 05068 230V AC

Ref. 05068CH 230V AC

Ref. 05068GB 230V AC

Ref. 05068AUS 230V AC

33
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
4,5 WATT POWER CONSUMPTION
PLUG SUPPLIED
34
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX Automatic Lens Groover Hand Edgers Page 36 Page 38
HAND EDGERS 4.5
35 4.4 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
40
41
Hand Edger Bench Polisher Page
Page

AUTOMATIC LENS GROOVER 4.5

Lens groover for supra frames

FOR LENSES FROM Ø 22 TO 54 MM

Ref. 05083

Automatic lens groover:

• Non corrosive machine body.

• Suitable for plastic and glass lenses.

• Adjustable groove position (front-central-rear).

• Two independent motors for turning the lens and for turning the groove cutting wheel.

• No water system required.

• Accurate on all profiles.

• Diamond groove cutter (Ref. 05081) suitable for glass and CR39 included.

• Adjustable groove depth: from 0.0 to 0.7 mm

• Groove width: 0.65 mm.

• Lens thickness: from 1.5 to 11 mm

Size: 170x220x205 mm

Weight: 2.7 kg

Ref. 05083 230V AC

Ref. 05083CH 230V AC

Ref. 05083GB 230V AC

Ref. 05083AUS 230V AC

GROOVE LOCATOR

To set the position of the groove on the lens (front - centre - rear)

GROOVE DEPTH Dial for setting groove depth in 0.1 mm increments

Diamond Groove Cutting Wheel

Ref. 05081 included

Diamond groove cutting wheel 0.65 mm for glass and CR39 (made in France)

DIAMOND GROOVE CUTTING WHEEL 0.65 mm for glass and CR39

KNOB

For the precise positioning of the groove

POWER CONSUMPTION

95

WATT

Ref. 05084

Diamond groove cutting wheel 0.65 mm for polycarbonate (made in France)

Ref. 05087

Diamond cutting wheel 1,0 mm for glass and CR39, complete with safety cover (made in France)

Ref. 05088

Diamond cutting wheel 1,2 mm with safety cover for glass and CR39 (made in France)

36
ALL
© LAB
FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
RIGHTS RESERVED
MOD SYSTEM
PLUG
SUPPLIED

AUTOMATIC LENS GROOVER 4.5

Instructions for use

Ref. 05085A.63A Centring piece with chain

Ref. 05085.62 Spring ✔

Ref. 05085.79 Driving belt for diamond wheel ✔

Ref. 05085A.19 Driving belt for lens rotation shaft

Ref. 05085B.17B Lens turning engine

Ref. 05087.2 Safety cover 1,0-1,2 mm ✔

Ref. 05086 Safety cover 0.65 mm ✔

Ref. 05085.26A Silicone support Ø 20 mm - 2 pcs. ✔

Ref. 05085.26B Silicone support Ø 13,5 mm - 2 pcs. ✔

Ref. 05089 Half-eye frame adapter ✔

Adjusting the groove position

CENTRE GROOVE

Groove follows centre of edges.

• Insert the centre pin between the two guide arms (Picture 1).

• Lift setting plate.

• Insert the setting pins as illustrated.

• Set groove locator to centre position.

CENTRING PIN

Insert the centring pin between the two guide arms so they move simultaneously. The groove will now be cut in the centre of the lens edge. When the pin is removed the two guide arms will move independently.

FRONT CURVE GROOVE:

The groove will follow the front curve of the lens.

• Remove the centre pin.

• Lift the settings plate.

• Remove the right setting pin and re-insert it into the setting guide marked “C/F” as illustrated.

• Rotate the groove locator counter clockwise.

• The distance from the edge depends on the setting of the groove locator. The closest setting from the edge is 0.7 mm.

BACK CURVE GROOVE:

The groove will follow the back curve of the lens.

• Remove the centre pin.

• Lift the setting plate.

• Remove the left setting pin and re-insert into the setting guide marked “C/R” as illustrated.

• Rotate the groove locator clockwise.

• The distance from the edge depends on the setting of the groove locator.

Centring pin

SETTING PINS C/R/F

By changing the position of the setting pins to the “R” and “F” guides it is possible to move the groove position to follow the front or the rear lens edge.

37
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
05085B 05083
✔ ✔
✔ ✔
✔ ✔

With water tank

Sensor for automatic starting and stopping

Hand edger complete with:

• Removable water tank

• Hand valve for water flux regulation

• Internal water tray with tail pipe

• Wheel can be set to rotate in either direction

• One cleaning stick included. Available with three different diamond wheels Ø 100 mm for CR39, glass (not for Ref. 05110), high index, polycarbonate lenses.

Power supply: 230V AC - 50Hz

Size: 220x360x280 mm

Weight: 8 kg

NO MINERAL LENSES

included.

HAND EDGER WITH SENSOR FOR AUTOMATIC STARTING AND STOPPING OF DIAMOND WHEEL

38
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 2.000 RPM SPEED Switch for the direction of rotation Switch ON/OFF Standard Sponge holder Water flux regulation for the cooling system Water tank 34 mm Finishing Rough 22 mm 12 mm 34 mm Finishing 34 mm Finishing Rough 22 mm 12 mm ROUGH AND FINISHING ROUGH AND FINISHING FINISHING 120 WATT POWER CONSUMPTION
HAND EDGER 4.5
Hand edger with standard diamond wheel Ref. 05116 for rough and finishing. Cleaning sticks Ref. 07300 Hand edger with special diamond wheel Ref. 05117 for rough and finishing Cleaning sticks Ref. 07300 included. Hand edger with special diamond wheel Ref. 05118 for finishing
Ref. 05110/13/15 230V AC Ref. 05110/13/15CH 230V AC Ref. 05110/13/15GB 230V AC Ref. 05110/13/15AUS 230V AC
Ref. 05110 with diamond wheel Ref. 05116 Ref. 05113 with diamond wheel Ref. 05117 Ref. 05115 with diamond wheel Ref. 05118 Ref. 05111.1 Driving belt

HAND EDGER 4.5

With diamond wheel - Main water supply cooling system

Compact design and very quiet running

Long life ABS casing and non-corroding metal parts

Infra-red sensor for automatic starting and stopping

Wheel can be set to rotate in either direction

TWO DIFFERENT COOLING OPTIONS

• From the main water supply incorporating automatic cut-off valve when not in use (frequently use).

• An internal water tank (for light duty work)

Avalaible with three different diamond wheels

Ø 110 mm for CR39, glass, high index, polycarbonate lenses

Ref. 05070/05072/05073/05077

Ref. 05070/05072/05073/05077CH

Ref. 05070/05072/05073/05077GB

ROUGH AND FINISHING FINISHING

Size: 180x299x178 mm

Weight: 7 kg

FINISHING AD POLISHING

Ref. 05070

HAND EDGER - COOLING SYSTEM: MAIN WATER SUPPLY

Hand edger with special diamond wheel for rough and finishing

Ref. 05073

Hand edger with special diamond wheel for finishing

Ref. 05077

Hand edger with special diamond wheel for finishing and polishing

HAND EDGER - COOLING SYSTEM: INTERNAL WATER TRAY

Ref. 05072

Hand edger with special diamond wheel for finishing

39
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
2.750 RPM SPEED 180 WATT POWER CONSUMPTION
34 mm Finishing Rough 22 mm 12 mm 34 mm Polishing Finishing 22 mm 12 mm 30 mm Finishing
230V AC
230V AC
230V AC
05070/05072/05073/05077AUS 230V AC
Ref.

HAND EDGER 4.5

With front facing diamond wheel - For finishing

HAND EDGER

With front facing diamond wheel

Technical features:

• Surface of the wheel with increased area of finishing, provided with V profile for chamfering.

• Wheel can be set to rotate in either direction.

• Internal tank can be easily removed for cleaning or for replacement of the refrigeration sponge. Available with two different finishing wheels for CR39, glass, high index, polycarbonate lenses.

Ref. 05121

Frontal Hand Edger with Standard diamond wheel for finishing

Ref. 05122

Frontal Hand Edger with High Quality diamond wheel for finishing.

Complete with:

• Removable internal tank

• Water-bottle for cooling diamond wheel

• Spare sponge

• One cleaning stick.

SUPPLIED

Ref. 05121/05122 230V AC

Ref. 05121/05122CH 230V AC

Ref. 05121/05122GB 230V AC

Ref. 05121/05122AUS 230V AC

Size: 175x 175x260mm

Weight: 7 kg

40
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 120 WATT POWER CONSUMPTION 3000 RPM SPEED
PLUG

BENCH POLISHER 4.5

Dual speed 1.400-2.800 rpm

BENCH POLISHER WITH 2 DUST GUARDS

Ref. 05109

Polishing system complete with:

• Two speed motor 1.400-2.800 rpm (Ref. 05100).

• Two safety/dust guards with removable plastic trays

• Twin taper spindles for “quick” mount and removal of brush chucks

• Two threaded “quick mount” brush chucks, left and right handed threads

• One “quick mount” wheel chuck .

Size: 540 x 270 x 280 mm

Weight: 12 kg

Ref.

Polishing motor Ref. 05100

POLISHING MOTOR

Ref. 05100

Two speed motor 1.400-2.800 rpm, complete with two threaded “quick mount” brush chucks and one “quick mount” wheel chuck

Size: 440x130x210 mm

Weight: 6.4 kg

TAPER BRUSH CHUCKS AND WHEEL MANDREL

Ref. 05104

Safety/dust guard Ref. 05147

SAFETY / DUST GUARD

Ref. 05147

Safety / dust guard with removable tray - 1 pc.

Size: 190x270x280 mm

Weight: 2.6 kg

Pair of threaded “quick mount” brush chucks, left and right handed threads.

Ref. 05105

Taper wheel mandrel Ø 8 mm.

41
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES 300 WATT POWER CONSUMPTION 1.400 2.800 RPM SPEED
05109 230V AC
05109CH 230V AC
05109GB 230V AC
05109AUS 230V AC
05100 230V AC
05100CH 230V AC
05100GB 230V AC
05100AUS 230V AC SPARE PARTS PLUG SUPPLIED Suggested polishing speed (r.p.m.) Material Hard polishing Fine polishing Glossing Acetate frame 2.800 1.400 2.800 White metal frame 1.400 1.400 2.800 Gold metal frame 1.400 1.400 2.800 Glass lens 2.800 2.800 Organic lens 1.400 2.800 Polycarbonate lens 1.400 2.800
Ref.
Ref.
Ref.
Ref.
Ref.
Ref.
Ref.
42 DRILLS 4.6 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
Page 44 Page 45 Hand drill Bench drill
43 4.6 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
46
Page
Lens Hole Drilling System

HAND DRILL 4.6

Low voltage hand drill

Drill bit holder

TRANSFORMER

Ref. 05520

Low voltage

Size: 130x145x65 mm

MINIMOT DRILL AND TRANSFORMER

Ref. 05511

Variable speed drill from 5.000 to 20.000 rpm

Ref. 05512 with transformer Ref. 05520.

• High torque at low speeds.

• Safe to use with coolants.

Accessories included:

• Keyless chuck (0.5 ÷ 3.2 mm)

• 6 collets with keyless chuck Ref. 05518.

PLUG SUPPLIED

Ref. 05520 230V AC

Ref. 05520GB 230V AC

Ref. 05520AUS 230V AC

Ref. 05520USA 115V AC

INCLUDED

Drill Rest

MINIMOT 40 DRILL Ref. 05512

Variable speed drill.

5,000 - 20,000 rpm.

Transformer not included.

Size: 230 mm - Ø 35 mm

Weight: 230 gr

Collets

SPEED

5.000

20.000 RPM

POWER CONSUMPTION

40 WATT

Keyless chuck

DRILL STAND

Ref. 05525

Column with vertical adjustment by means of a rack rod with return spring.

Connection for drill Minimot

Ø 20 mm.

90° tiltable head on both sides with dovetail guides.

Practical indication of the drilling depth with adjustable end stop.

Maximum stroke 40 mm.

Rectified worktop with millimetre scale.

Size: 120x220x280 mm.

Weight : 2.2 kg

NEW
44
ALL
RESERVED © LAB
LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
RIGHTS
MOD SYSTEM FRAME PARTS

BENCH DRILL 4.6

Bench Press Drill

BENCH PRESS DRILL

Ref. 05530

• 3-spindle speed belt driven drill

• (1.800 - 4.500 - 8.500 rpm.).

• Throat distance 140 mm.

• Drill stroke 30 mm.

• Adjustable working column

• height 280 mm and depths stop.

Accessories included:

• Chuck Ref. 05532 with key.

• Machine vice (Ref. 05535)

• 6 individual collets (Ref. 05518).

Ref. 05530 230V AC

Ref. 05530GB 230V AC

Ref. 05530AUS 230V AC

Ref. 05532

Chuck with key

0,0 ÷ 5,0 mm

Ref. 05535

Machine vice.

50x10 mm jaws

34 mm clamping width

Keyless chuck

Size: 120x225x340 mm

Weight: 3.2 kg

Collets

Ref. 05518

Set 6 collets, keyless chuck included

3 SPEED RPM 85 WATT

POWER CONSUMPTION

1,800 4,500

8,500

SPARE PARTS

Ref. 05530.2

Driving belt

45
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES

LENS DRILLING SYSTEM 4.6

With double inclination: pantoscopic angle and convergence of sides

DRILL STAND AND LENS CLAMPING SYSTEM

• Pantoscopic inclination.

• Sides convergence inclination.

• Milling notches device.

• Milling slots and Air-T slots device.

• Precision scale.

• Complete range of suction cup centring devices: Weco-Topcon, Essilor, Indo-Hoya-Nidek.

LENS DRILLING SYSTEM

Ref. 05592

• Lens-clamping assembly.

• Slide with graduated scale.

• Variable speed drill Minimot (Ref. 05512).

• Transformer 230V AC a.c. for Minimot (Ref. 05520). Centring device not included.

Dimensions: 220x230x400 mm

Weight: 4.8 Kg

DRILL STAND

Ref. 05594

Drill stand with clamp for drill Ref. 05512 (Ø 34 mm), complete with:

• Lens-clamping assembly

• Slide with graduated scale.

Drill and centring device not included.

CENTRING DEVICE (to be ordered separately)

Ref. 05601

W - For Weco, Briot, Topcon suction cups

Ref. 05602

E - For Essilor suction cups

Ref. 05604

I - For Indo, Hoya, Nidek suction cups

ACCESSORIES

Ref. 02399

Assortment of 11 special hard metal drills from 0,8 to 2,2 mm

46
ALL
RESERVED ©
RIGHTS
5.000 20.000 RPM VARIABLE SPEED 40 WATT POWER CONSUMPTION
LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX

LENS DRILLING SYSTEM 4.6

For precise lens hole placement

INCLINATION FOR HOLES

• Position lenses with suction cups on to the centring device

• Turn the clamp until the lens surface is at 90° to the drill

• Proceed with drilling.

INCLINATION

FOR NOTCHES

• Position lenses with suction cups on to the centring device

• Turn the clamp until the lens surface is at 90° to the drill

• Lower miller into position and clamp

• Fasten the limit stop to determine the depth of the notch

• Move the lens-clamping assembly until it hits against the limit stop.

INCLINATION

FOR SLOTS

• Position lenses with suction cups on to the centring device

• Lower miller to commence cutting the slot, starting at the centre

• Slide the lens-clamping assembly slightly to the left, cutting the first half of the slot

• Then slide the lens-clamping assembly slightly to the right, cutting the second half of the slot

• For 5 mm slots use the pattern blank (located on the back of the lens-clamping assembly)

• For the right lens, place the pattern blank on the right, for the left lens on the left, and use the 1,2 mm drill.

Pattern blank for slots

PANTOSCOPIC INCLINATION

• Position lenses with suction cups on to the centring device

• Loosen the stand and choose the pantoscopic inclination

• Fasten the stand and proceed with drilling.

• Change inclination for the other lens. Side

47
ALL RIGHTS RESERVED ©
0° ÷ 10° max
stop
with inclination
Limit
Rotational clamp
LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
48
EMBEDDING  WELDING
4.7 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
50
HINGE
UNITS
Page 51 Page
Electric Soldering Welding Units Hinge Embedding Unit

For laboratory

Miniflam Solder Torch

For occasional use

49 4.7 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
Professional Soldering Machine Page 52 Page
54

For replacing hidden hinges

Ref. 06450

Foot pedal controlled also used to:

• Place metal pad arms on to plastic frames

Size: 185x155x105 mm

Weight: 2.2 Kg

PLUG SUPPLIED

Ref. 06450 230V AC

Ref. 06450CH 230V AC

Ref. 06450GB 230V AC

Ref. 06450AUS 230V AC

REPLACEMENT OF BROKEN HIDDEN HINGES:

Press the two tips on to the plate of the broken hinge and press the foot pedal to start. Keep a gap between the tips.

SPARE PARTS

Ref. 06450.1 Contact tips

When the plastic around the hinge begins to soften release the foot pedal and quickly remove hinge.

Hold new hinge into position and press the foot pedal to heat.

As soon as the plastic begins to melt, stop heating and gently press on the hinge with the plier so that the hinge sinks into the frame.

POWER CONSUMPTION 3 4

Correctly position the new hinge and release the foot pedal.

Keep holding the hinge in position for a few seconds until plastic hardens.

50
EMBEDDING
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
HINGE
UNIT 4.7
130 WATT 1 2
Heat up and loosen screws stuck with glue or thread lock.

ELECTRIC CARBON WELDING UNIT 4.7

Electric carbon welding unit

Ref. 06145

Electric carbon welding unit including foot pedal control.

Size: 180x156x210 mm

Weight: 4,5 Kg

SPARE PARTS

Ref. 06152

Foot pedal control

Ref. 06154

PLUG SUPPLIED

Ref. 06145 230V AC

Ref. 061450CH 230V AC

Carbon electrode Ø 8 mm. 300

Ref. 06145GB 230V AC

Ref. 06145AUS 230V AC

51
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
RIGHTS
WATT POWER CONSUMPTION

SOLDERING UNITS 4.7

Water electrolisys system

Hydrogen soldering unit suitable for:

• Hard and soft soldering

• Soldering metal frames quickly and with very good results

Ref. 06051

Micro-soldering unit complete with:

• soldering tips

Ø 0.7 - 0.8 - 0.9 mm.

• Boric acid solution

Ref. 06022.

• Caustic solution electrolyte Ref. 06020 liquid for Europe, Ref. 06054 in grains for overseas shipments.

Size: 280x235x290 mm;

Weight: 14 kg.

PLUG SUPPLIED

Ref. 06050/06051 230V AC

Ref. 06050/06051CH 230V AC

Ref. 06050/06051GB 230V AC

Ref. 06050/06051AUS 230V AC

Ref. 06050

Micro-soldering unit Ref. 06051 with soldering set Ref. 06058.

SPARE PARTS

Ref. 06065 Soldering tip Ø 0.7 mm (4 pcs.)

Ref. 06066 Soldering tip Ø 0.8 mm (4 pcs.)

Ref. 06067 Soldering tip Ø 0.9 mm (4 pcs.)

Ref. 06051.3 Plastic tube 1,5 mt.

Ref. 06051.50 Set of 4 rubber gaskets

Ref. 06056 Check valve

Ref. 06053 Hand piece

52
ALL
© 300 WATT POWER CONSUMPTION ~3000° FLAME TEMP. C°
RIGHTS RESERVED
LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
3000°C

SOLDERING UNITS 4.7

Soldering set and consumables

Ref. 06058

Soldering set complete with:

• Soldering tweezers Ref. 03730,

• Third hand table Ref. 06195,

• Solder wire Ø 0.5 mm Ref. 06200,

• Solder wire Ø 0.3 mm Ref. 06202,

• Powder borax flux 100 gr. Ref. 06208,

• 3 solder rods with flux core Ref. 06210,

• Heat-shielding paste Ref. 06221. Tray included suitable for the new LMS Cube.

Consumables

Ref. 06020

Caustic solution - for Europe

electrolyte 0.5 lt. - 2 pcs.

Ref. 06022

Boric Acid solution - flux 0.5 lt.

FOR SHIPMENTS BY AIR

Ref. 06055

Boric Acid in grains

25 g

Ref. 06195

Third hand soldering table with two clamps connected to universal joints.

Size: 305x195x90 mm.

SPARE PARTS

Ref. 06199

Clamp with extended universal joint.

53
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES

MINIFLAM 4.7

Soldering torch

1.600°C

MINIFLAM

Ref. 06101

Miniflam soldering torch.

Size: 205 mm - Ø 25 mm

Weight: 130 gr

Refill with quality butane only (Ref. 06108).

Air switch

Gas switch

Ref. 06108

Butane gas. 400 ml bottle

54
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX

SOLDERING CONSUMABLES 4.7

Choosing the right alloy

SOLDER RODS WITH FLUX CORE

Ref. 06210

CADMIUM FREE

Soft yellow solder. Melting range: 655°C - 680°C

Pack of 10 rods - 250 mm each Ø 1,15 mm

Ref. 06214

Yellow gold solder. Melting range: 605°C- 635°C

Pack of 10 rods - 250 mm each Ø 1,15 mm

Heat the parts to be soldered together. As the metal is heated keep touching the parts to be soldered with the solder rod. Be very careful not to heat the soldering rod directly with the flame. The solder will melt when the temperature of the two parts reaches the critical soldering temperature.

SOLDER WIRE

All-purpose soldering wire in silver alloy (40%).

Easy flowing, suitable for nickel silver and monel metal.

Melting range: 610°C - 650°C.

Ref. 06200 Ø 0,5 mm.

Ref. 06202 Ø 0,3 mm.

Length: 2,5 mt

Solder wire is used for soldering small parts, where little solder is required. Heat the area to be soldered first, then dip into borax flux paste (borax flux powder Ref. 06208 mixed with some drops of distilled water).

Protect those parts that are close to the area being heated with ISOFLAM heat shielding paste (Ref. 06221).

Borax flux powder to be mixed with hot distilled water to make a paste. Promotes quick and easy flow of solder between the surfaces being soldered.

Melting range: 500°C - 700°C.

Essential when using soldering wire (Ref. 06200 - 06202).

100 g

SOLDERING SET

Ref. 06058

Soldering set complete with:

• Soldering tweezers Ref. 03730,

• Third hand table Ref. 06195,

• Solder wire Ø 0.5 mm Ref.06200,

• Solder wire Ø 0.3 mm Ref.06202,

• Powder borax flux 100 gr. Ref. 06208,

• 3 solder rods with flux core Ref. 06210,

• Heat-shielding paste Ref. 06221. Tray included suitable for the new LMS Cube.

Heat shielding paste. It will protect the non-soldered area by dissipating heat for temperatures up to 3,000°C 5,432°F. It isolates parts close to the soldering point and reduces the risk of damage to plastic and painted parts. It does not stain and washes off in water.

50 g

55
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
RIGHTS
Ref. 06208 Ref. 06221 BORAX ISOFLAM

PREPARATION

• Always wear safety glasses.

• First, remove any parts that will be affected by heat, e.g. pads, rim cover, temple tips.

• Before heating, it may be necessary to apply a large amount of protective heat shield paste ISOFLAM (Ref. 06221) over those parts that are close to the area being heated.

• Next, remove broken part by heating the area until it becomes detached. Use tweezers Ref. 03730 to help.

POLISHING

• Always prepare the surfaces to be soldered first by using the rubber abrasion wheels (Ref. 02444 - Ref. 02447). A clean, smooth surface ensures a good result.

• Alternatively use a file.

PROTECTION OF THE PARTS CLOSE TO THE SOLDERING POINT

• Apply ISOFLAM protection paste (Ref. 06221) around the soldering point and on any components (nose pads, enamelled parts, etc.).

• After soldering, the paste can be recovered and reused by adding a few drops of distilled water.

POSITIONING OF THE FRAME

• Place the frame on the soldering table (Ref. 06195) to give easy access to the part being soldered. The clamps should be kept away from the soldering area to avoid overheating.

• Rest your elbows to support the hands.

• The parts to be soldered should not be close to the table top.

PLANNING THE SOLDER

• If you are not using SOLDER rods (Ref. 06210-6214), prepare the solder wire (Ref. 06200-06202) in advance by wetting it and dipping it in borax flux powder (Ref. 06208).

• Always heat first the thicker surface as it reaches the melting point in longer time by absorbing more heat.

• Dip the soldered part in water.

• Use protective goggles during all soldering steps.

56
4.7 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
SOLDERING STEPS

SOLDERING STEPS 4.7

Use of the different solder alloys

FRONT HINGE PLATE

The part connecting the temple hinge to the eye wire rim is subject to great stress. Having a large supporting surface it is recommended to use the solder rods Ref. 06210 - Ref. 06214, or the 0.5 mm solder wire Ref. 06200.

RIM CLOSING BLOCK

When soldering the closing block to the rim, as the surface area is quite small, it is recommended that a small amount of solder is carefully placed. Recommend 0.3 mm wire Ref. 06202.

HINGES

Part of the frame that allows the temple to pivot. Recommended to use the solder rods Ref. 06210 and Ref. 06214, or the 0.5 mm solder wire Ref. 06200.

POLISHING

After de-scaling remove and smooth residues of solder with rubber abrasion wheels (Ref. 02444 -Ref. 02447).

Alternatively, use the brass (Ref. 02421) or steel brushes (Ref. 02422). Next polish with silicone wheels (Ref. 02442) or hard felt brushes (Ref. 02429).

CLEANING

For best results clean the frame with an ultrasonic cleaner using concentrated detergent for ultrasonic cleaners, not to damage the frames and any type of lenses. High cleaning capacity enhanced by the mechanical action of the ultrasonic cleaner.

FINISHING

To touch-up soldered parts use these coloured lacquers. Ideal for individualising or personalising frame parts.

ACTIVE LIQUID

WITH

ANTIBACTERIAL PROPERTIES

Thanks to its active enzymes, this detergent can also be used without ultrasonic cleaner, just with lukewarm water. Its antibacterial properties sanitize the spectacles.

Ref. 06859 1litre bottle

Add one/two cupfuls of detergent to 1 litre of water. 100% NO ALCOHOL

TOUCHUP BRUSH KIT

Ref. 07100 - 07104 - 07106 - 0710907110 - 07111 - 07112 - 0711607117 - 07120 - 07121.

Ref. 07118

Set of 12 lacquers. (Ref. 07100 Shiny Black - 2 pcs.)

57
ALL
© LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
RIGHTS RESERVED

Two and four plates

58 TINTING UNITS 4.8 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
Page 61 Page 60

Lens tinting is a treatment carried out for sun protection, medical and aesthetic reasons.

Tinting techniques depend on the material with which the lens is made.

The technique commonly used for plastic materials in CR39, Polycarbonate and High Index is by immersion into hot tinting liquid.

59 4.8 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
Page 63 Automatic Gradient Unit Accessories Page 62

TINTING UNIT 4.8

Two plates

TWO PLATE TINTING UNIT

Ref. 06520

• Thermostat for temperature control

• Timer for regulation of the pre-heating phase

Dye pots not included. Plates Ø 120 mm.

Power consumption: 450 W each plate

Size: 155x415x210 mm

Weight: 4.2 kg.

Ref. 06518

Complete with:

• Two plate tinting unit Ref. 06520

• 2 stainless steel dye pots with lids Ref. 06529

• 1 stainless steel lens holder Ref. 06525

• 1 package of 12 clear plano lenses Ref. 06660

• 1 celsius thermometer Ref. 23564

• 1 litre neutralising solution Ref. 06850

• 10 assorted dyeing powders

Ref.

Ref.

Ref.

Ref.

SPARE PARTS

Ref. 06511

Heating element

Ref. 05012

Switch on-off

POWER CONSUMPTION

900 WATT

60
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX
06518/06520 230V AC
06518/06520CH 230V AC
06518/06520GB 230V AC
06518/06520AUS 230V AC
PLUG SUPPLIED

TINTING UNIT 4.8

Four plates with thermostat for temperature control

FOUR PLATE TINTING UNIT

Ref. 06505

Four plate tinting unit.

Operates as two independent tinting units with two plates per unit.

• Thermostat for temperature control.

• Timer with alarm.

Dye pots not included.

Plates: Ø120 mm

Power consumption: 900 W /double plates

Size: 345x440x215 mm

Weight: 8.9 kg.

PLUG SUPPLIED

Ref. 06505/06507 230V AC

Ref. 06505/06507CH 230V AC

Ref. 06505/06507GB 230V AC

Ref. 06505/06507AUS 230V AC

Ref. 06507

Complete with:

• Four plate tinting unit Ref. 06505

• 4 stainless steel dye pots with lids Ref. 06529

• 1 stainless steel dual lens holder Ref. 06525

• 1 package of 12 clear plano CR39 lenses Ref. 06660

• 1 celsius thermometer Ref. 23564

• 1 neutralising solution Ref. 06850

• 10 assorted dyeing powders

SPARE PARTS

Ref. 06511

Heating element

Ref. 05012

Switch on-off

POWER CONSUMPTION

1800 WATT

61
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
RIGHTS

AUTOMATIC GRADATION UNIT 4.8

With timer

AUTOMATIC GRADATION UNIT WITH TIMER

Ref. 06580

Allows to gradate all plastic lens types gradually. Incorporates a 30 minutes timer.

A mechanical arm allows alternate dipping of the lens into the bath in order to reach identical graduation on all plastic lenses. The oscillation time is programmed by the operator.

The graduated effect on the lens can be adjusted.

Size: 150x150x455mm

Weight: 4.1 kg.

Ref. 06580 230V AC

Ref. 06580CH 230V AC

Ref. 06580GB 230V AC

Ref. 06580AUS 230V AC

62
ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX 30 WATT POWER CONSUMPTION
PLUG
SUPPLIED

ACCESSORIES FOR TINTING 4.8

Free-standing lens holder

Ref. 06525

Holds one or two lenses of the same size under spring pressure. A large base keeps the stand free in the pot. Stainless steel.

Ref. 06527

Holds one or two lenses of the same size under spring pressure. Made of s/steel and heat resistant plastic.

Dye pot and thermometer

Ref. 06529

Stainless steel pot with lid, large heat proof knob.

Capacity 1 litre - Ø 120 mm

The special bottom allows for a uniform heat distribution and maintains the temperature constant. Suitable for tinting units Ref. 0650506520.

Ref. 06547

Stainless steel pot with lid.

Capacity 1 litre - Ø 120 mm

Suitable for oil bath tinting units.

Ref. 23564

Celsius thermometer -10 °C / +150 °C.

63
ALL
RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
RIGHTS

CLEANLINESS

The biggest problem in tinting is contamination. The pot must be absolutely clean before fresh tints are mixed. Any residual colour remaining in the pot will affect the new colour. Boil neutralizer in the pot to ensure perfect cleanliness. Thoroughly rinse with clean water.

PREPARING THE TINT

Half fill the pot with distilled water and heat to 60°C (140°F) then add dye powder. Stir mixture until dye is completely dissolved. For liquid dyes shake the bottle well before adding hot water. Add some distilled water and flush tint pot to ensure all the contents are being used. If required add more water to make up 1 litre of dye solution.

USE DISTILLED WATER

Limestone, chlorine and water impurities can often cause inconsistencies in dye properties. Impurities can cause colour “haloes” when tinting lenses.

FLUSH THE BOTTLES WELL

Make sure the tint pot is completely emptied of dye and dye sediment when mixing as it affects the composition of the colour.

DO NOT MIX DYE WITH COLD WATER

Often dyes will not dissolve easily in cold water and deposits may form in the bottom of the pot. Conversely, if the dye concentrate is left to settle, the high hot plate temperature may cause crystallisation which will also affect colour consistency. Stir dyes regularly during preparation.

DO NOT MIX THE DYE WITH WATER OVER 90°C (194°F)

The dye may crystallise and will not mix evenly. This could affect colour consistency.

ADVANTAGES OF MIXING THE COLOUR AT 60°C (140°F)

The colour mixes homogenously as it gradually reaches the temperature of 92°C-95°C (198 - 203°F). Mixing and stirring the dyes at 60ºC for 10-15 minutes makes it very stable and ensures a homogenous colour mix.

HEATING AND WATER LOSS REPLACEMENT

Slowly heat the solution for about 20 minutes until it reaches 92°C-95°C (198203°F). Do not heat with a flame as that tends to concentrate the heat whereas it should be evenly spread around the dye pot. During tinting water is lost through evaporation. It is recommended that small quantities of distilled water be added to the bath to compensate for this loss. It should be at the same pot temperature when added.

DO NOT HEAT QUICKLY

The temperature on the bottom and around the sides of the container is usually higher than in the centre. Fast heating may cause crystallisation which effects a colour consistency and dye life.

WATER REPLENISHEMENT

Add small quantities of distilled water regularly to overcome loss due to evaporation. Wait until the dye temperature has recovered to 92°C -95°C (198°F -203°F). As more water is added, colour strength will change. A top-up of dye may also be necessary from time to time.

MIXING

AND CORRECTING COLOURS

When mixing and correcting colours ALWAYS rinse the lenses and lens holder in clean water before proceeding to the next colour. Contamination is the quickest and the most common way of spoiling colour consistency. This rule also applies when adding other properties like hard coatings and when neutralising or bleaching out colour. The rule is - thoroughly wash the lens and lens holder in clean water before transferring them to another colour or process.

64 DO’S AND DON’TS OF TINTING 4.8 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS LAB CONSUMABLES TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX

PREPARING THE LENS

Lenses should be edged first before tinting. Thoroughly cleaning and degreasing the lens before tinting allows for rapid and uniform tinting.

Slowly immerse the lens into the hot tint bath: do not rush as a sudden temperature change may affect the lens surface. Keep the temperature at 92°C95 °C (198 - 203°F).

TINTING

Slowly immerse the lenses in holder into the hot tinting liquid to avoid splashing and lens strain.

DYE BATH SHOULD ALWAYS BE BETWEEN 92°C - 95°C (198 - 203°F)

At these high temperatures, the tint and CR39 molecules bond to form part of the lens structure. The lens continues to cure in the dyeing process and has a more scratch resistant surface. At a lower temperature the dyeing cycle is longer and there is difficulty in obtaining dark tints, this increases the possibility of inferior and unstable tinting of the lens.

DO NOT DYE AT A HIGHER TEMPERATURES ABOVE 95ºC (203°F)

• There is a greater water loss through evaporation.

• Crystallisation of the dye will occur and colour consistency will fail.

• Higher exposure to fumes in the working area.

• Possible softening of the lens may require more careful handling.

• More power used unnecessarily.

HOW TO OBTAIN GRADIENT LENSES

If you do no have a gradient unit use the lens holder. Prepare the lens as previously described. For prescription lenses, turn them upside down when placing them in the lens holder so the top of the lens is closest to the bottom of the tint pot. Immerse the holder until the dye covers the lens. Move the lens holder up and down and at the same time gradually withdrawing it from the solution until the lens has been completely withdrawn. With practice a perfect gradient will be achieved. The starting depth determines the start of the gradient line.

COLOUR CORRECTION

BROWN LENSES

Too much Dip lens into Red Grey and blue

Grey Yellow

Green Red, then Blue Blue Pink

AFTER TINTING

GREY LENSES

Too much Dip lens into Brown Blue

Purple Yellow

Green Pink

Blue Brown

GREEN LENSES

Too much Dip lens into Yellow Blue

Grey Decolour

Brown Blue

Blue Brown or yellow

Immediately wash lenses and lens holder in clean cold water. As hot lenses scratch more easily this practice will help eliminate potential lens damage. The use of MACROCLEAN microfibre cloth is recommended. These clothes can be kept clean by regular washing.

AVOID USING PAPER TISSUES THAT ARE NOT LINT OR ACID FREE.

CHECK UV TRANSMITTANCE

The UV & Visible Spectrotester (Ref. 05053) is ideal to test the UV and visible transmittance of a lens after tinting.

65 TINTING STEPS 4.8 ALL RIGHTS RESERVED © LAB MOD SYSTEM FRAME PARTS TOOLS PLIERS EQUIPMENTS LENSES REFRACTION & ORTHOPTIC INDEX LAB CONSUMABLES
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.