Skip to main content

    Sylvain Giraud

    The Journal of Biological Chemistry Skip to main page content. ...
    Some recent studies have characterized the stability of blood variables commonly measured for the Athlete Biological Passport. The aim of this study was to characterize the impact of different shipments conditions and the quality of the... more
    Some recent studies have characterized the stability of blood variables commonly measured for the Athlete Biological Passport. The aim of this study was to characterize the impact of different shipments conditions and the quality of the results returned by the haematological analyzer. Twenty-two healthy male subjects provided five EDTA tubes each. Four shipment conditions (24, 36, 48, 72 h) under refrigerated conditions were tested and compared to a set of samples left in the laboratory also under refrigerated conditions (group control). All measurements were conducted using two Sysmex XT-2000i analyzers. Haemoglobin concentration, reticulocytes percentage, and OFF-score numerical data were the same for samples analyzed just after collection and after a shipment under refrigerated conditions up to 72 h. Detailed information reported especially by the differential (DIFF) channel scatterplot of the Sysmex XT-2000i indicated that there were signs of blood deterioration, but were not of...
    OBJECTIVE: The major objective of this study was to investigate the effects of several days of intense exercise on growth hormone (hGH) testing using the World Anti-Doping Agencies hGH isoform differential immunoassays. Additionally the... more
    OBJECTIVE: The major objective of this study was to investigate the effects of several days of intense exercise on growth hormone (hGH) testing using the World Anti-Doping Agencies hGH isoform differential immunoassays. Additionally the effects of circadian variation and exercise type on the isoform ratios were also investigated. STUDY DESIGN: 15 male athletes performed a simulated nine day cycling stage race. Blood samples were collected twice daily over a period of 15days (stage race+three days before and after). hGH isoforms were analysed by the official WADA immunoassays (CMZ Assay GmbH). RESULTS: All measured isoform ratios were far below the WADA decision limits for an adverse analytical finding. Changes in the isoform ratios could not be clearly connected to circadian variation, exercise duration or intensity. CONCLUSIONS: The present study demonstrates that the hGH isoform ratios are not significantly affected by exercise or circadian variation. We demonstrated that heavy, l...
    The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. All qualified players from the 32 teams... more
    The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2-8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. Logistical issues...
    The major objective of this study was to investigate the effects of several days of intense exercise on the growth hormone marker approach to detect doping with human growth hormone (hGH). In addition we investigated the effect of changes... more
    The major objective of this study was to investigate the effects of several days of intense exercise on the growth hormone marker approach to detect doping with human growth hormone (hGH). In addition we investigated the effect of changes in plasma volume on the test. Fifteen male athletes performed a simulated nine-day cycling stage race. Blood samples were collected twice daily over a period of 15 days (stage race + three days before and after). Plasma volumes were estimated by the optimized CO Rebreathing method. IGF-1 and P-III-NP were analyzed by Siemens Immulite and Cisbio Assays, respectively. All measured GH 2000 scores were far below the published decision limits for an adverse analytical finding. The period of exercise did not increase the GH-scores; however the accompanying effect of the increase in Plasma Volume yielded in essentially lower GH-scores. We could demonstrate that a period of heavy, long-term exercise with changes in plasma volume does not interfere with the...
    ABSTRACT The construction of protein-like folding motifs as structurally stable scaffolds for the introduction of function represents a major goal in protein design. The use of topol. templates allows the bypass of the well-known folding... more
    ABSTRACT The construction of protein-like folding motifs as structurally stable scaffolds for the introduction of function represents a major goal in protein design. The use of topol. templates allows the bypass of the well-known folding problem of linear polypeptides and offers a way to mimic native packing topologies by the template directed self-assembly of helical and/or b-sheeted peptide blocks. In conceptually sepg. structure from function, a chimeric 4-helix bundle TASP (Template Assembled Synthetic Protein) derived from the ROP protein and the cell adhesion glycoprotein E-selectin has been designed and synthesized, aimed at inhibiting an early stage in cell adhesion processes, in particular leukocyte adhesion. [on SciFinder (R)]
    The GH-2000 project developed a method for detecting GH misuse based on the measurement of insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objective of this study was to develop... more
    The GH-2000 project developed a method for detecting GH misuse based on the measurement of insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objective of this study was to develop decision limits for the GH-2000 score to detect GH misuse in elite athletes using two currently available commercial assays for each analyte. 404 male (mean age 23.9 yrs, range 12-37 yrs) and 94 female elite athletes (mean age 24.5 yrs, range 18-34 yrs) participated. Blood samples were collected according to World Anti-Doping Agency (WADA) guidelines at various sporting events including 238 samples collected as part of the UK Anti-Doping Testing Programme. Laboratory analysis: IGF-I was measured by Siemens Immulite IGF-I assay and Immunotech A15729 IGF-I IRMA. P-III-NP was measured by RIA-gnost P-III-P and the UniQ™ PIIINP RIA. The GH-2000 score decision limits were developed through the analysis of the elite athlete samples. For males and females separately, the distributions of GH-2000 scores were consistent with Normal distributions. Using a specificity of 99.99% new decision limits were determined which included an allowance for uncertainty associated with calculations based on a finite sample size. One outlier was identified with results incompatible with normal physiology and tested positive with the current isoform GH test. We have developed decision limits using currently available commercial assays to measure IGF-I and P-III-NP in elite athletes. This should allow the introduction of a test for GH misuse based on the measurement of these GH sensitive biomarkers.
    Since the 1990's, cheating athletes have abused substances to increase their oxygen transport capabilities; among these substances, recombinant EPO is the most well known.... more
    Since the 1990's, cheating athletes have abused substances to increase their oxygen transport capabilities; among these substances, recombinant EPO is the most well known. Currently, other investigational pharmaceutical products are able to produce an effect similar to EPO but without having chemical structures related to EPO; these are the synthetic erythropoiesis stimulating agents (ESAs). Peginesatide (also known as Hematide™) is being developed by Affymax and Takeda and, if approved by regulatory authorities, could soon be released on the international market. To detect potential athletic abuse of this product and deter athletes who consider cheating, we initiated a collaboration to implement a detection test for anti-doping purposes. Peginesatide is a synthetic, PEGylated, investigational, peptide-based erythropoiesis-stimulating agent that is designed and engineered to stimulate specifically the erythropoietin receptor dimer that governs erythropoiesis. It is undetectable using current anti-doping tests due to its lack of sequence homology to EPO. To detect and deter potential abuse of peginesatide, we initiated an industry/antidoping laboratory collaboration to develop and validate screening and confirmation assays so that they would be available before peginesatide reaches the market. We describe a screening ELISA and a confirmation assay consisting of immune-purification followed by separation with SDS-PAGE and revelation with Western double blotting. Both assays can detect 0.5 ng/mL concentrations of peginesatide in blood samples, enabling detection for several days after administration of a physiologically relevant dose. This initial report describes experimental characterization of these assays, including testing with a blinded set of samples from a clinical study conducted in healthy volunteers.