Skip to main content
    Atypical cartilaginous tumours are usually treated by curettage. The purpose of this study was to show that radiofrequency ablation was an effective alternative treatment. We enrolled 20 patients (two male, 18 female, mean age 56 years... more
    Atypical cartilaginous tumours are usually treated by curettage. The purpose of this study was to show that radiofrequency ablation was an effective alternative treatment. We enrolled 20 patients (two male, 18 female, mean age 56 years (36 to 72) in a proof-of-principle study. After inclusion, biopsy and radiofrequency ablation were performed, followed three months later by curettage and adjuvant phenolisation. The primary endpoint was the proportional necrosis in the retrieved material. Secondary endpoints were correlation with the findings on gadolinium enhanced MRI, functional outcome and complications. Our results show that 95% to 100% necrosis was obtained in 14 of the 20 patients. MRI had a 91% sensitivity and 67% specificity for detecting residual tumour after curettage. The mean functional outcome (MSTS) score six weeks after radiofrequency ablation was 27.1 (23 to 30) compared with 18.1 (12 to 25) after curettage (p < 0.001). No complications occurred after ablation, whi...
    Knowing the timing of the pubertal growth spurt of the spine, represented by sitting height, is essential for the prognosis and therapy of adolescent idiopathic scoliosis. There are several indicators that reflect growth or remaining... more
    Knowing the timing of the pubertal growth spurt of the spine, represented by sitting height, is essential for the prognosis and therapy of adolescent idiopathic scoliosis. There are several indicators that reflect growth or remaining growth of the patient. For example, distal body parts have their growth spurt earlier in adolescence, and therefore the growth of the foot can be an early indicator for the growth spurt of sitting height. Shoe size is a good alternative for foot length, since patients can remember when they bought new shoes and what size these shoes were. Therefore the clinician already has access to some longitudinal data at the first visit of the patient to the outpatient clinic.The aim of this study was to describe the increase in shoe size during adolescence and to determine whether the timing of the peak increase could be an early indicator for the timing of the peak growth velocity of sitting height. Data concerning shoe sizes of girls and boys were acquired from ...
    Background Previous studies on physical activity after total knee arthroplasty (TKA) concentrated mainly on a return to sports activities. Objective The objectives of this study were to determine the habitual physical activity behavior of... more
    Background Previous studies on physical activity after total knee arthroplasty (TKA) concentrated mainly on a return to sports activities. Objective The objectives of this study were to determine the habitual physical activity behavior of people who had undergone TKA (TKA group) 1 to 5 years after surgery and to examine to what extent they adhered to international guidelines for health-enhancing physical activity. Additional aims were to compare younger (<65 years old) and older (≥65 years old) people as well as men and women in the TKA group and to compare the results for the TKA group with those for a sex- and age-matched normative population (normative group). Design This investigation was a cohort study. Methods All people who had a primary TKA at 1 of 2 participating hospitals between 2002 and 2006 were sent the Short Questionnaire to Assess Health-Enhancing Physical Activity at least 1 year after surgery. Results The TKA group spent, on average, 1,347 minutes per week on ph...
    Radiopacity in the vast majority of the commercially available acrylic bone cements that are used clinically is provided by particles of either BaSO(4) or ZrO(2). Literature reports have shown these agents to have a detrimental effect on... more
    Radiopacity in the vast majority of the commercially available acrylic bone cements that are used clinically is provided by particles of either BaSO(4) or ZrO(2). Literature reports have shown these agents to have a detrimental effect on some mechanical properties of the cements as well as on its biological response. We, therefore, have developed a new type of bone cement, for which radiopacity results from the presence of an iodine-containing methacrylic copolymer. The focus of the present work was the comparison of the biocompatibility of this new cement and a commercially available cement that contains barium sulfate. In vitro experiments show that both cements are cytocompatible materials, for which no toxic leachables are found. Implantation of the cements in a rabbit for three months resulted in the occasional presence of a thin fibrous tissue at the cement-bone interface, which is common for acrylic bone cements. Consideration of all the results led to the conclusion that the new cement is as biocompatible as the BaSO(4)-containing one.
    Between 1980 and 1985, silicone hemiprostheses were implanted because of hallux rigidus in 58 feet of 43 patients who were followed up after an average of 5 years. The majority were satisfied and had good function without pain. However,... more
    Between 1980 and 1985, silicone hemiprostheses were implanted because of hallux rigidus in 58 feet of 43 patients who were followed up after an average of 5 years. The majority were satisfied and had good function without pain. However, the toes had shortened because of implant wear, and there was considerable associated osteolysis.
    Title: Minimally invasive and computer-navigated total hip arthroplasty. A qualitative and systematic review of the literature.
    There is an association between osteoarthritis-related pain severity and function, yet clear evidence about the sole influence of neuropathic-like symptoms on joint function and health-related quality of life (HRQoL) is lacking. Previous... more
    There is an association between osteoarthritis-related pain severity and function, yet clear evidence about the sole influence of neuropathic-like symptoms on joint function and health-related quality of life (HRQoL) is lacking. Previous studies among knee OA patients show an association between neuropathic-like symptoms, lower functional status and lower quality of life, however analyses were unadjusted or had limited adjustment for influential covariates like pain intensity. The aim of this study was therefore to determine the influence of neuropathic-like symptoms-adjusted for multiple influential covariates-on joint-specific function and HRQoL in hip and knee OA patients. In this observational study 255 patients (117 with hip OA and 138 with knee OA) completed the modified painDETECT questionnaire (mPDQ) to identify subjects with neuropathic-like symptoms (mPDQ score>12, possible neuropathic pain [NP] phenotype). The WOMAC and the RAND-36 were used to asses respectively funct...
    The most commonly used definition of iron deficiency (ID; ferritin <100 ng/mL or ferritin 100-300 ng/mL and transferrin saturation [TSAT] <20%) has not been validated in patients with heart failure (HF). We aimed to define and... more
    The most commonly used definition of iron deficiency (ID; ferritin <100 ng/mL or ferritin 100-300 ng/mL and transferrin saturation [TSAT] <20%) has not been validated in patients with heart failure (HF). We aimed to define and validate the biomarker-based definition of ID in HF, using bone marrow iron staining as the gold standard. Second, we aimed to assess the prognostic value of the optimized definition. Bone marrow aspiration with iron staining was performed in 42 patients with HF and a reduced left ventricular ejection fraction (≤45%) undergoing median sternotomy for coronary artery bypass grafting. Patients were mostly male (76%) with mild-to-moderate HF and a mean age of 68±10 years. Bone marrow ID was found in 17 (40%) of the HF patients. The most commonly used definition of ID had a sensitivity of 82% and a specificity of 72%. A definition solely based on TSAT ≤19.8% or serum iron ≤13 µmol/L had a sensitivity of 94% and specificity of 84% and 88%, respectively (<0....
    Background and purpose - Alternative bearing surfaces such as ceramics and highly crosslinked polyethylene (HXLPE) were developed in order to further improve implant performance of total hip arthroplasties (THAs). Whether these... more
    Background and purpose - Alternative bearing surfaces such as ceramics and highly crosslinked polyethylene (HXLPE) were developed in order to further improve implant performance of total hip arthroplasties (THAs). Whether these alternative bearing surfaces result in increased longevity is subject to debate. Patients and methods - Using the Dutch Arthroplasty Register (LROI), we identified all patients with a primary, non-metal-on-metal THA implanted in the Netherlands in the period 2007-2016 (n = 209,912). Cumulative incidence of revision was calculated to determine differences in survivorship of THAs according to bearing type: metal-on-polyethylene (MoPE), metal-on-HXLPE (MoHXLPE), ceramic-on-polyethylene (CoPE), ceramic-on-HXLPE (CoHXLPE), ceramic-on-ceramic (CoC), and oxidized-zirconium-on-(HXL)polyethylene (Ox(HXL)PE). Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons. Results - After adjustment for confounders, CoHXLPE, CoC, and Ox(HXL)PE r...
    Persistent wound leakage after joint arthroplasty is a scantily investigated topic, despite the claimed relation with a higher risk of periprosthetic joint infection. This results in a lack of evidence-based clinical guidelines for the... more
    Persistent wound leakage after joint arthroplasty is a scantily investigated topic, despite the claimed relation with a higher risk of periprosthetic joint infection. This results in a lack of evidence-based clinical guidelines for the diagnosis and treatment of persistent wound leakage after joint arthroplasty. Without such guideline, clinical practice in orthopaedic hospitals varies widely. In preparation of a nationwide multicenter randomized controlled trial on the optimal treatment of persistent wound leakage, we evaluated current Dutch orthopaedic care for persistent wound leakage after joint arthroplasty.We conducted a questionnaire-based online survey among all 700 members of the Netherlands Orthopaedic Association, consisting of 23 questions on the definition, classification, diagnosis and treatment of persistent wound leakage after joint arthroplasty.The questionnaire was completed by 127 respondents, representing 68% of the Dutch hospitals that perform orthopaedic surgery...
    The modified painDETECT questionnaire (PDQ) is a self-reported questionnaire to discriminate between nociceptive and neuropathic-like pain in patients with knee/hip osteoarthritis (OA). This study aims to assess the structural and... more
    The modified painDETECT questionnaire (PDQ) is a self-reported questionnaire to discriminate between nociceptive and neuropathic-like pain in patients with knee/hip osteoarthritis (OA). This study aims to assess the structural and construct validity of this questionnaire. Confirmatory factor analysis and hypothesis-testing was used. For 168 patients, predefined hypotheses were formulated on the correlation between the modified painDETECT and several other questionnaires, and in a subsample of 46 with pain pressure thresholds (PPTs). Two principal components were confirmed. The pain pattern item did not load on any component. Eighty per cent of the hypotheses on the correlation between modified PDQ and the questionnaires were met, as were 50% concerning PPTs measurements. This study is the first to assess structural and construct validity of the modified PDQ knee/hip by using factor analysis and hypothesis-testing. This questionnaire seems to reflect neuropathic-like pain symptoms ex...
    Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are highly successful treatment modalities for advanced osteoarthritis. However, prolonged wound leakage after arthroplasty is linked to prosthetic joint infection (PJI),... more
    Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are highly successful treatment modalities for advanced osteoarthritis. However, prolonged wound leakage after arthroplasty is linked to prosthetic joint infection (PJI), which is a potentially devastating complication. On the one hand, wound leakage is reported as a risk factor for PJI with a leaking wound acting as afor micro-organisms. On the other hand, prolonged wound leakage can be a symptom of PJI. Literature addressing prolonged wound leakage is scarce, contradictory and of poor methodological quality. Hence, treatment of prolonged wound leakage varies considerably with both non-surgical and surgical treatment modalities. There is a definite need for evidence concerning the best way to treat prolonged wound leakage after joint arthroplasty. A prospective nationwide randomised controlled trial will be conducted in 35 hospitals in the Netherlands. The goal is to include 388 patients with persistent wound leakage 9-...
    Patient-reported outcome measures (PROMs) are used to evaluate the outcome of total hip arthroplasty (THA). We determined the effect of surgical approach on PROMs after primary THA. All primary THAs, with registered preoperative and 3... more
    Patient-reported outcome measures (PROMs) are used to evaluate the outcome of total hip arthroplasty (THA). We determined the effect of surgical approach on PROMs after primary THA. All primary THAs, with registered preoperative and 3 months postoperative PROMs were selected from the Dutch Arthroplasty Register. Based on surgical approach, 4 groups were discerned: (direct) anterior, anterolateral, direct lateral, and posterolateral approaches. The following PROMs were recorded: Hip disability and Osteoarthritis Outcome Score Physical function Short form (HOOS-PS); Oxford Hip Score; EQ-5D index score; EQ-5D thermometer; and Numeric Rating Scale measuring pain, both active and in rest. The difference between preoperative and postoperative scores was calculated (delta-PROM) and used as primary outcome measure. Multivariable linear regression analysis was performed for comparisons. Cohen's d was calculated as measure of effect size. All examined 4 approaches resulted in a significan...
    To assess the therapeutic validity and effectiveness of physiotherapeutic exercise interventions following total hip arthroplasty (THA) for osteoarthritis. The databases Embase, MEDLINE, Cochrane Library, CINAHL and AMED were searched... more
    To assess the therapeutic validity and effectiveness of physiotherapeutic exercise interventions following total hip arthroplasty (THA) for osteoarthritis. The databases Embase, MEDLINE, Cochrane Library, CINAHL and AMED were searched from inception up to February 2017. Articles reporting results of randomized controlled trials in which physiotherapeutic exercise was compared with usual care or with a different type of physiotherapeutic exercise were included, with the applied interventions starting within six months after THA. Only articles written in English, German or Dutch were included. Therapeutic validity (using the CONTENT scale) and risk of bias (using both the PEDro scale and the Cochrane Collaboration's tool) were assessed by two researchers independently. Characteristics of the physiotherapeutic exercise interventions and results about joint and muscle function, functional performance and self-reported outcomes were extracted. Of the 1124 unique records retrieved, tw...
    IntroductionOsteoarthritis is the most common joint disorder worldwide. Total hip arthroplasty (THA) is considered one of the most effective treatments for end-stage hip osteoarthritis. The number of THAs is expected to increase... more
    IntroductionOsteoarthritis is the most common joint disorder worldwide. Total hip arthroplasty (THA) is considered one of the most effective treatments for end-stage hip osteoarthritis. The number of THAs is expected to increase dramatically in the coming decades. Usual postoperative rehabilitation after primary THA differs between the German and the Dutch system. In the Netherlands, patients undergo fast-track surgery and are discharged into their home environment within a few days without receiving any aftercare. In Germany, patients stay in the hospital for about 12 days before being transferred to a rehabilitation centre for a period of 3 weeks. The superficially more cost-effective Dutch system of usual care after THA is judged critically in both countries due to suboptimal rehabilitation outcomes. The aim of this study is therefore to compare the Dutch with the German usual care rehabilitation after primary THA. It is hypothesised that the German procedure is more effective in...
    Background and Purpose Self-report and performance-based measures of physical functioning in people before and after total hip arthroplasty seem to present different information. The relationship between these different measures is not... more
    Background and Purpose Self-report and performance-based measures of physical functioning in people before and after total hip arthroplasty seem to present different information. The relationship between these different measures is not well understood, and little information is available about changes in this relationship over time. The aims of this study were: (1) to determine the relationship between self-report and performance-based measures of physical functioning before and after total hip arthroplasty, (2) to assess the influence of pain on the relationship, and (3) to determine whether the relationship changes over time. Subjects and Methods Seventy-five subjects admitted for total hip arthroplasty were included and examined before and 6 and 26 weeks after surgery. The relationships between the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical functioning subscale and walking speed and gait variability were examined by use of generalized estimati...
    The purpose of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a trabecular metal cone while the tibial component is implanted with and without a stem, and whether prosthetic... more
    The purpose of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a trabecular metal cone while the tibial component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density. Trabecular metal cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear whether this is necessary after reconstruction with a trabecular metal cone. Implanting a stem can give extra stability, but may have negative side effects. Tibial revision arthroplasties with trabecular metal cones were performed after reconstruction of a 2B bone defect according to the Anderson Orthopedic Research Institute classification. Components were implanted in seven pairs of cadaveric tibiae; one tibia of each pair was implanted with stem and the other without. All specimens were loaded to one bodyweight alternating between t...
    Length of hospital stay (LOS) greatly influences costs of total hip arthroplasty (THA). LOS is, among others, dependent on patient comorbidity. American Society of Anesthetists (ASA) scores are traditionally used as comorbidity measure,... more
    Length of hospital stay (LOS) greatly influences costs of total hip arthroplasty (THA). LOS is, among others, dependent on patient comorbidity. American Society of Anesthetists (ASA) scores are traditionally used as comorbidity measure, but simple medication-based measures may suffice. Therefore, the objective of the study is to determine if medication-based measures (count of medication and the medication-based index Chronic Disease Score [CDS]) have a surplus value compared to a diagnosis-based measure for comorbidity (ASA score) to predict LOS in THA. A retrospective cohort study. THA patients from 3 hospitals were included for 2009-2013, and demographic data, comorbidity (ASA score), and medication use (count of medication and CDS) were collected. A binomial regression model was used to compare the predictive ability of the medication-based and diagnosis-based measures. A total of 2,282 THA patients were included. Number of medications proved a statistical significant predictor ...
    Background and purpose - Combining components from different manufacturers in total hip arthroplasty (THA) is common practice worldwide. We determined the proportion of THAs used in the Netherlands that consist of components from... more
    Background and purpose - Combining components from different manufacturers in total hip arthroplasty (THA) is common practice worldwide. We determined the proportion of THAs used in the Netherlands that consist of components from different manufacturers, and compared the revision rates of these mixed THAs with those of non-mixed THAs. Patients and methods - Data on primary and revision hip arthroplasty are recorded in the LROI, the nationwide population-based arthroplasty register in the Netherlands. We selected all 163,360 primary THAs that were performed in the period 2007-2014. Based on the manufacturers of the components, 4 groups were discerned: non-mixed THAs with components from the same manufacturer (n = 142,964); mixed stem-head THAs with different manufacturers for the femoral stem and head (n = 3,663); mixed head-cup THAs with different head and cup manufacturers (n = 12,960), and mixed stem-head-cup THAs with different femoral stem, head, and cup manufacturers (n = 1,773). Mixed prostheses were defined as THAs (stem, head, and cup) composed of components made by different manufacturers. Results - 11% of THAs had mixed components (n = 18,396). The 6-year revision rates were similar for mixed and non-mixed THAs: 3.4% (95% CI: 3.1w-3.7) for mixed THAs and 3.5% (95% CI: 3.4-3.7) for non-mixed THAs. Revision of primary THAs due to loosening of the acetabulum was more common in mixed THAs (16% vs. 12%). Interpretation - Over an 8-year period in the Netherlands, 11% of THAs had mixed components-with similar medium-term revision rates to those of non-mixed THAs.
    The objective of the present study was to determine the incremental cost-effectiveness of a clinical pathway for patients undergoing joint replacement, the Joint Recovery Programme (JRP), as compared with usual care. The existing care... more
    The objective of the present study was to determine the incremental cost-effectiveness of a clinical pathway for patients undergoing joint replacement, the Joint Recovery Programme (JRP), as compared with usual care. The existing care process was revised to contain costs and shorten waiting lists by facilitating patient flows and improve healthcare efficiency. The study design was a before-after trial. In total, 160 patients undergoing total hip and total knee replacement, aged 28 to 87 years (mean age, 64.4 years), were treated either according to the Joint Recovery Programme (a standardized care process with patient education and rehabilitation in groups) or usual care. Both groups were followed for 1 year. Costs were studied from a societal perspective. Outcomes included functional level (Harris Hip score and American Knee Society score) and generic quality of life (EuroQol). The results indicate that the Joint Recovery Programme resulted in a significant cost saving when compared with usual care mainly as a result of a considerable (>50%) reduction in length of hospital stay. The average cost saving per patient amounted to $1261 in the total hip replacement group and $3336 in the total knee replacement group. At the same time, both functional level and quality of life were higher in the JRP group. Clinical pathway dominates usual care and is a highly cost-effective approach to contain costs related to joint replacement surgery without adverse consequences for patients.
    Objective of this study was to compare intraoperative computer-assisted surgery (CAS) alignment measurements during total knee arthroplasty (TKA) with pre- and postoperative coronal alignment measurements using EOS 3D reconstructions. In... more
    Objective of this study was to compare intraoperative computer-assisted surgery (CAS) alignment measurements during total knee arthroplasty (TKA) with pre- and postoperative coronal alignment measurements using EOS 3D reconstructions. In a prospective study, 56 TKAs using imageless CAS were performed and coronal alignment measurements were recorded twice: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D reconstructions. Thanks to the EOS radiostereography system, measurement errors due to malpositioning and deformity during acquisition are eliminated. CAS measurements were compared with EOS 3D reconstructions. Varus/valgus angle (VV), mechanical lateral distal femoral angle (mLDFA) and mechanical medial proximal tibial angle (mMPTA) were measured. Significantly different VV angles were measured pre- and postoperatively with CAS compared to EOS. For preoperative measurements, mLDFA d...
    The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet,... more
    The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15° varus to 15° valgus and flexion angle from 0° to 20°, and changing rotation from 20° internal to 20° external rotation. Differences between the actual VV position of the lower limb phantom and its position as measured on EOS 2D and 3D images were investigated. Rotation, flexion or VV angle alone had no major impact on VV2D or VV3D. Combination of VV angle and rotation with full extension did not show major differences in VV2D measurements either. Combination of flexion and rotation with a neutral VV angle showed variation of up to 7.4° for VV2D; maximum variation for VV3D was only 1.5°. A combination of the three variables showed an even greater distortion of VV2D, while VV3D stayed relatively constant. Maximum measurement difference between preset VV angle and VV2D was 9.8°, while the difference with VV3D was only 1.9°. The largest differences between the preset VV angle and VV2D were found when installing the leg in extreme angles, for example 15° valgus, 20° flexion and 20° internal rotation. After TKA, EOS VV3D were more valid than VV2D, indicating that 3D measurements compensate for malpositioning during acquisition. Caution is warranted when measuring VV angle on a conventional radiograph of a knee with a flexion contracture, varus or valgus angle and/or rotation of the knee joint during acquisition.
    There is a growing amount of evidence that alteration in pain processing by the peripheral and central nervous system play a role in osteoarthritis pain, leading to neuropathic-like symptoms. It is essential to identify knee and hip... more
    There is a growing amount of evidence that alteration in pain processing by the peripheral and central nervous system play a role in osteoarthritis pain, leading to neuropathic-like symptoms. It is essential to identify knee and hip osteoarthritis patients with a neuropathic pain profile in order to offer such patients education and additional treatment options besides conventional pain treatment. The painDETECT Questionnaire is a self-report questionnaire developed to discriminate between nociceptive and neuropathic pain. This questionnaire was modified to fit patients suffering from knee osteoarthritis. The aim of this study was to translate and cross-culturally adapt the modified painDETECT Questionnaire to the Dutch language and to provide a modified version to fit patients with hip osteoarthritis. Reliability for internal consistency, repeatability and floor and ceiling effects were subsequently assessed. A total of 278 patients were included in the reliability study and 123 patients in the repeatability analysis. The Dutch modified painDETECT Questionnaire shows good internal consistency and small relative measurement errors, represented by a good intraclass correlation coefficient. Absolute measurement error, represented by the Standard Error of Measurement, was acceptable. However, a measurement bias might be present when it comes to repeatability. To our knowledge, this study is the first to provide a Dutch modified painDETECT Questionnaire to fit hip and knee osteoarthritis patients and to assess internal consistency, reliability and agreement. International guidelines were followed in the translation process and this study has ample sample size with an adequate time interval for repeatability. Based on this study, the Dutch modified painDETECT Questionnaire seems to be fit as a discriminative tool to identify knee and hip osteoarthritis patients with a neuropathic pain profile. Whether it is also suitable as an evaluative tool to record changes over time or after an intervention remains open to further investigation.
    In adults the preferred hand is often considered to be around 10% stronger than the non-preferred hand. Whether the same is true for children and adolescents remains unclear. The objective of this study is therefore to determine whether... more
    In adults the preferred hand is often considered to be around 10% stronger than the non-preferred hand. Whether the same is true for children and adolescents remains unclear. The objective of this study is therefore to determine whether there is a difference in grip strength between the preferred and non-preferred hand in developing children, to establish whether this difference is similar for children of a different gender or hand preference, and whether there is a difference in grip strength of the preferred hand of left-preferent (LP) and right-preferent (RP) children. Cross-sectional study. Participants were recruited from schools in the northern provinces of the Netherlands. The study included healthy children and adolescents in the age range of 4-17 years. Each child was allowed a total of four attempts using the JAMAR hand dynamometer, two attempts with each hand. All individual attempts were scored. Hand preference was determined by asking which hand was used to write, or in the case of 4- and 5-year-olds, which hand was used to draw a shape. The study population comprised 2284 children and adolescents. RP boys and girls scored significantly higher with their preferred hand, the difference amounting to 9.5 and 10.1% respectively. LP girls scored significantly higher with their preferred hand, but this difference was only 3.0%. For LP boys no significant difference was found in favor of either hand. LP children score higher with the non-preferred hand and tie scores on both hands more often than RP children. The 10% rule of hand preference is applicable to RP children ranging in age between 4 and 17 years, but not to LP children. In contrast to LP boys, LP girls are generally significantly stronger with their preferred hand.

    And 146 more