Annexin V Apoptosis Detection Kit APC

RUO: For Research Use Only
human Annexin V antibody, Cytokine Kits conjugateJurkat cells were either untreated (left) or treated for 4 hours with 10 ĩM camptothecin (right) and then stained with the Annexin V Apoptosis Detection Kit APC and Propidium Iodide Staining Solution (cat. 00-6990). The Annexin V+ PI- population contains early stage apoptotic cells.
Contents: Annexin V Apoptosis Detection Kit APC
Catalog Number: 88-8007
Formulation: 50mM Tris, pH 7.4, 100mM NaCl, 1% BSA, 0.02% Sodium Azide
Storage Conditions: Store at 2-8°C. Do not freeze. Light sensitive material.
 
Product Options
Cat. No. Size Price Add Qty to Cart
88-8007-72 50 tests
To view relevant pricing, please select your country and resume browsing.

88-8007-74 200 tests
Note: Several countries will continue to be supplied via distributors. Country specific prices may apply.
 
Research Related Products
Cat. No.Format
00-6990 Propidium Iodide Staining Solution
00-6993 7-AAD Viability Staining Solution
65-0865 Fixable Viability Dye eFluorŪ 780
88-8005 Annexin V Apoptosis Detection Kit FITC
88-8006 Annexin V Apoptosis Detection Kit eFluorŪ 450
88-8008 Annexin V Apoptosis Detection Kit PerCP-eFluorŪ 710
 

Available Formats
Cat. No.FormatExcite
(nm)
Emit
(nm)
Reported ApplicationsRegulatory Status
88-8007 Annexin V Apoptosis Detection Kit APC N/A N/A FC RUO
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µL to 5 µL. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Alexa FluorŪ 647 conjugated products with eFluorŪ 660 conjugated products.
 
Description
Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner.

In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD, or Fixable Viability Dyes such as eFluorŪ 660 or eFluorŪ 780. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative).

Not included:
Propidium Iodide Staining Solution (cat. 00-6990).
7-AAD Viability Staining Solution (cat. 00-6993)

Note: Fixable Viability Dye eFluorŪ 450 is not recommended for use with Annexin V Apoptosis Detection Kits.
Components
10X Binding Buffer:
Annexin V 10x Binding Buffer is a stock solution that must be diluted prior to use with distilled water. Dilute 1 part Binding Buffer with 9 parts distilled water..
-50 Test kit comes with 30 ml (cat. 00-0055-43)
-200 Test kit comes with 100 ml (cat. 00-0055-56)
Annexin V-APC:
-50 or 200 Test kit (5µl/test)
Applications Reported
For research use only, not for diagnostic or therapeutic use. Annexin V-APC Apoptosis Detection Kit has been reported for use in flow cytometric analysis.
Applications Tested
Annexin V-APC Apoptosis Detection Kit has been pre-titrated and tested on Jurkat cells treated with 10µM Camptothecin for 4 hours. This can be used at 5µl per million cells in a 100µl total staining volume.
Special Notes
This kit is compatible with eBioscience IC Fixation Buffer (cat. 00-8222) for intracellular staining. It is recommended that eBioscience Fixable Viability Dyes (cat. 65-0863, and 65-0865) are used for viability staining for all intracellular staining protocols.
References
Andree HA, Reutelingsperger CP, Hauptmann R, Hemker HC, Hermens WT, Willems GM. Binding of vascular anticoagulant alpha (VAC alpha) to planar phospholipid bilayers. J Biol Chem. 1990; 265(9):4923-4928

Koopman G, Reutelingsperger CP, Kuijten GA, Keehnen RM, Pals ST, van Oers MH. Annexin V for flow cytometric detection of phosphatidylserine expression on B cells undergoing apoptosis. Blood. 1994; 84(5):1415-1420

Vermes I, Haanen C, Steffens-Nakken H, Reutelingsperger C. A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled Annexin V. J Immunol Methods. 1995; 184(1):39-51
Protocol
To view protocol, please download the TDS by clicking the PDF button above.
Legal
Pat. No. EP 181 465 B2, EP 0509 026, USP 5,066,787

Home  |   Index  |   Site Map  |   FAQ  |   Terms & Conditions  |   Distributors  |   Careers  |   Contact Us
Copyright © 2000-2010 eBioscience, Inc.
Unless indicated otherwise, all products are For Research Use Only. Not for use in diagnostic or therapeutic procedures. Not for further distribution without written consent. Not all products available in all regions.